Document KJq9MbzpoXNb0NNo4O7XRbz0o
NATIONAL CONFERENCE ON
POLYCHLORINATED BIPHENYLS
JAMES P. MIEURE CHARACTERIZATION OF POLYCHLORINATED BIPHENYLS
November 19 - 21, 1975 Pick - Congress Hotel Chicago, Illinois
Monsanto
0480953
TOWOLDMONOQ58697
CHARACTERIZATION OF POLYCHLORINATED BIPHENYLS
J. P. Mieure, 0. Hicks, R. G. Kaley and V. W. Saeger Monsanto Company 800 N. Lindbergh Blvd. St. Louis, Missouri 63.166
CHEMICAL STRUCTURE Polychlorinated biphenyls (PCBs) are made by direct chlorination of biphenyl. The biphenyl molecule has ten possible sites at which chlorine atoms can be substituted. The numbering system for the biphenyl structure is shown in Figure 1. By convention, the two rings are numbered identically except the ring with the fewest chlorine substituents or substituted in the highest numerical positions is designated as primed. Examples of nomenclature for a tri- and a tetrachlorobiphenyl are included in Figure 1. An excellent discussion of PCB nomenclature can be found in a recent text by Hutzinger, Safe and Zitko (1).
There are 209 possible chlorobiphenyl isomers distributed as Indicated in Table I. However, many of these isomers are not likely to occur at significant levels in commercial PCB mixtures. For example, isomers with four or five chlorine atoms on one ring but none on the other ring are not detectable in PCB products.
0<B095<|
-2-
TABLE I
209 POSSIBLE PCB ISOMERS
Degree of Substitution
Number of Isomers
Mono Di Tri Tetra Penta Hexa Hepta Octa Nona Deca
3 12 24 42 46 42 24 12 '3
1
209
AROCLOR PRODUCTS The major producer of PCBs In the United States is Monsanto Company, which markets mixtures for closed electrical system applications under the Aroclor trademark. Aroclor products are identified by a
four digit numbering code in which the first two digits, 12, indicate the parent molecule Is biphenyl and the last two digits specify the weight percent of chlorine. The exception is Monsanto's newest product, Aroclor 1016 (41% chlorine), which retained the 1016 designation by which It was known during development. Aroclor products manufactured in the United States are listed in Table II. Production of the materials listed as discontinued was terminated in or prior to 1971.
TOWOLDMONOQ58699
-3-
TABLE II
AROCLOR PRODUCTS MANUFACTURED IN THE U.S.
Current
Discontinued
Percent Chlorine
1221
1016 1242
1254
1232
1248
1260 1262 1268
.
21 32 41 42 48 54 60 62 68
AROCLOR COMPOSITION The composition of the four Aroclor products currently marketed In the United States is given in Table III. Aroclor 1221 is primarily monochlorobiphenyl while Aroclor 1016 and Aroclor 1242 are primarily trichlorobiphenyls. The major difference between these two products is the lower penta- and hexachlorobiphenyl content of Aroclor 1016. Aroclor 1254 is primarily pentachlorobiphenyl. The values in Table III were calculated from measurements by gas chromatography with flame ionization detection after component identification by gas chromatography/ mass spectrometry. All gas chromatographic separations were made with a high resolution capillary column. Average response factors determined for each degree of chlorine substitution were applied to all components.
0460956
TOWOLDMON0058700
-4-
TABLE III
TYPICAL PERCENT COMPOSITION OF AROCLOR PRODUCTS
HOMOLOG # ciMphenYl
0 1 2 3 4 5 6 7 8
AROCLOR 1221
11 51 32
4 2 <0.5 ND ND ND
AROCLOR 1016
<0.1 1
20 57 21
1 <0.1 ND ND
AROCLOR 1242
<0.1 1
16 49 25
8 1 <0.1 ND
AROCLOR 1254
<0.1 <0.1 <0.5
1 21 . 48 23
6 ND
ND = NONE DETECTED, <0.01%
Detailed chromatograms of these four products are illustrated in Figures 2-5. Specific isomer identifications determined by Webb and McCall (2) and Sissons and Welti (3) are listed for the major Aroclor 1242 components in Figure 4. The complexity of these mixtures was emphasized by amplifying the first and last portions of the Aroclor 1254 chromatogram in Figure 5. Eighty-five components were detected in Aroclor 1254. A .32 mm idX 50 m glass capillary column coated with 0V-101 was used for these separations. The flow rate was 2 ml/min helium and the column temperature was programmed from 150 to 230C at 2C/min.
046095?
TOWOLDMONOQ58701
-5-
Hlgh resolution chromatographic conditions are very useful for characterizing PCB products. However, for routine monitoring of environmental materials, it is more appropriate to use gas chromatog raphy with packed columns and electron capture detection. Typical
chromatograms of this type for Aroclor 1016 and Aroclor 1242 are compared in Figure 6. The chromatograms are essentially identical for retention times less than 70 relative to p,p'-DDE. However, the higher chlorinated components with relative retention times 70 and greater represent a significantly smaller contribution in the Aroclor 1016 chromatogram. These chromatograms illustrate the feasibility of distinguishing these unaltered products. However, in environmental materials the characteristic features of Aroclor 1242 are frequently obscured by interfering compounds or by component alteration so the distinction is less clear or sometimes entirely lacking. These separations were carried out on a 6 ft. X 4 mm id glass column packed with 3% SE-30 on 80/100 mesh Chromosorb W - HP at 190C.
PHYSICO-CHEMICAL DIFFERENCES
The physical and chemical properties of PCB isomers and commercial
mixtures vary greatly depending on the degree and position of chlorine
substitution. The effect of chlorine content on several physico-chemical
properties is summarized in Table IV. Three of these properties,
volatility, water solubility, and biodegradability, are very relevant
to the environmental occurrence of PCBs. Volatility and water solubility
represent potential mechanisms for introduction into and transport
within the ecosystem. Biodegradation represents a mechanism for
removing PCBs from the environment. Illustrations of the relative
significance of these properties for different PCB isomers are evident
from the following three examples.
.
0 < ,6 0 S 5 8
-6-
TABLE IV PHYSICO-CHEMICAL PROPERTIES FOR PCB PRODUCTS
Property Density (g/ml)
Percent Chlorine 21 42 54
1.19
1.39
1.50
Distillation Range (C)
275-320
325-366
365-390
Fire Point (C)
176 None None
Vaporization Rate (mg/cm2/hr @100C)
1.74
.338
.053
Water Solubility (ppm)
>.2 .2-
.04
Biodegradability*
81 26
15
Percent degradation/48 hr cycle with semi -continuous activated sludge
Relative volatilities for the PCB components in Aroclor 1016 are indicated in Figure 7 by comparinq chromatoarams of liquid and vapor composition. The higher numbered components make successively less contribution to the total vapor composition.
Water solubility of Aroclor 1016 components is illustrated in similar
fashion in Figure 8. Water saturated with Aroclor 1016 was extracted
with hexane and the extract compared chromatographically to an Aroclor
1016 standard. The numbers above significant peaks express the
percentage contribution of that peak area to the total area. Earlier
eluting, lower chlorinated components are more soluble and contribute
more to the water saturated composition. A related study has shown that
PCBs leaching from Aroclor 1016 impregnated soils after the equivalent
of forty years annual rainfall consist of lower chlorinated biphenyls (4)
(Figure 9).
o<t0959
TOWOLDMON0058703
-7Microblal degradation also affects PCB Isomers to different degrees. For example, Figure 10 shows chromatograms depicting Aroclor 1016 composition after exposure to a naturally occuring mixed microbial population for 1/2 hour (above) and 14 days (below). The number above each GC peak indicates the percent biodegradation for that component. These percentages range from 17 to >98 and in general are higher for lower chlorobiphenyls. The exposure was carried out with activated sludge from a domestic sewage treatment facility. The sludge was previously acclimated to a mixture of industrial organic compounds, before addition of 3 ppm Aroclor 1016. PCB composition was determined by extracting a representative aliquot of mixed liquor with hexane followed by analysis by gas chromatography using a glass capillary column and electron capture detection. It is apparent from these examples that introduction of PCBs into the ecosystem by volatility or water solubility would enhance the ratio of lower to higher chlorinated biphenyls in the environment. PCB removal from the environment by either of these mechanisms or by microbial degradation would reduce this ratio. These and related factors combine to make assessment of PCB environmental impact a very complex problem.
In view of the recognized complexity in studying commercial PCB mixtures, it would seem expedient to substitute for the mixture a single isomer product having the desired electrical and physical properties. The environmental properties of this isomer would be much simpler to
0<,a09b0
TOWOLDMONOQ58704
-8-
characterlze and control. However, no such PCB Isomer exists. Most PCB isomers are solid crystalline materials when isolated at 25C. Commercial products are liquids only because of the mutual melting point depression exerted by the PCB components of the mixture.
CONCLUSIONS
Commercial PCB products are mixtures of many different Isomers with
varying chlorine content. The properties of these isomers, and hence
the products, are vastly different and are complex to study. The
environmental impact for each product must be accurately assessed and
compared to the functional benefit.
'
0*180961
TOWOLDMONOQ58705
REFERENCES 1. 0. Hutzinger, S. Safe and V. Zitko, "The Chemistry of PCBs"
CRC Press, Cleveland, 1974. 2. R. G. Webb and A. C. McCall, J. Assoc. Offic. Anal. Chem.,
55, 746(1972). 3. 0. Sissons and D. Welti, J. Chromatog., 60, 15(1971). 4. E. S. Tucker, W. J. Litschgl and W. M. Mees, Bull. Environ.
Contain. Toxicol., J3i, 86(1975).
0980962
TOWOLDMONOQ58706
32
2' 3'
56
6'
BIPHENYL
Cl Cl
Cl
5'
Cl Cl
Cl
2,2' ,3,4' -TETRACHLOROBIPH ENYL Figure 1
0460963
TOWOLDMONOQ58707
AROCLOR 1221
150
Figure 2
<f9408V0
TOWOLDMONOQ58708
<;9f>o0>o
AROCLOR 1016
150 Figure 3
TOWOLDMON0058709
Ol N
"> in
"> w ** cm'
M jJjjLk jl
LJL
150 174 198
Figure 4
AROCLOR 1242
^
222 230
99608V3
TOWOLDMONOQ58710
49609*70
ARQCLOR 1254
Figure 5
TOWOLDMONOQ58711
TOWOLDMONOQ58712
Response
h9 6 op *7o I
Time (Min)
Figure 7
TOWOLDMONOQ58713
h o e 170
AROCLOfi 1015
Figure 8
TOWOLDMONOQ58714
0460971
TOWOLDMONOQ58715
TOWOLDMONOQ58716