Document KJkjB8Gv63BOpepbJpkgxVx6N
FILE NAME: Square D(SQD) DATE: 2014
DOC#: SQD017
DOCUMENT DESCRIPTION: Legal - Deposition of Redfield for Square D A p p # ll
I
* '
ROWTE Tof
~
5Q U RRE T1 COMPANY IN TER -O FFIC E
DM
w/tou MS~ 11
ATTXHTIOK C. W. Denny III
.v Bill Vosdingh
February 26, 1979
&W8JKCT
Asbestos-Free Molding Material
C.E. W.H. E.J. C, R. R.D. L.C.
Ashley - PS Woito - ME Fritz - EF Junttila - ME-1 Boley - M0 Plant Kovar - MQ Plant
Dear Charley,
Following is a brief resume of the molding material the Missouri Plant will be molding and the asbestos-free replacement status:
1. Plenco 509-120 flow #1593-000220 used on Q1 base covers, Q2 bases and covers and miscellaneous parts. Plenco 548-110 flow #1593-200810 is the approved replacement material.
2. Plenco 509-140 flow #1593-000222 This is the injection version. Missouri should be able to use either the asbestos-free version of Plenco 509 or the injection version of Plenco 548, because the parts they will be molding all used to be made from weaker general-purpose materials before they were converted to inline.
I would recommend using Plenco 548 because of its lower specific gravity. General Electric material P4304E-CH #1593-200661 is an approved inline material which we are starting to use here on the FA 3-pole covers, It Is probably a better material than Missouri requires.
3. Rogers 468 #1593-000170 used on Q1 bases and covers. We have Plenco 552 approved for these parts. Durez 30871, which Lincoln is using, failed on Q1 tests. We have not converted to Plenco 552 here because we have been unable to get a version that would not clog the Vac-u-max filters. However, if Missouri goes to some sort of gravity feed in to the press hopper, they should have no problem in using it. I am also going to sample Rogers 862 material as a possible replacement for Rogers 468.
1 hope this answers the questions concerning these materials.
Bill Vosdingh sf
SQDKVR 000701
I SgUFtRBTI gOMPflNY
f
IN T ER -O FFIC E
&
, ^U 1"C'5e'dar Rapids mot Missouri J '
AirrcNriOM
V^' -6
C.W. Denny III
R.D. Boley
Asbestos -- Free Molding Material
0^ &'
,,,TB October 5, 1979
e.c.. W.E. Ballin - MM G.L. Emanuel - IE L.C. Kovar - PS R.X. Molde - QM B.F. Wesseldine - TE J.L. Wiseman - EM
Dear Charley:
The following is a summary of where we are with regard to bur conversion to asbestos - free molding material.
I. Inline Machines:
We presently are using asbestos-filled Plenco 509-140 flow. We have molded samples of the Q2 Blade Insulator of Plenco 548, asbestos-free material. Our intent is to standardize on Plenco 548 for all inline molded parts presently molded of Plenco 509-140.
Production,Engineering' is now assembling test samples. The testing
will be performed in Missouri and a decision will be made no. later
than October 15.
.
II. Compression Machines:
ll Q1 Base and Cover - molded of Rogers 468 asbestos-filled material/ Cedar Rapids has approved Durez 31099, asbestos-free material, as a replacement for Rogers 468. We have sampled Durez 31099 to test for moldability and strength. These tests were successful. Missouri has ordered 1000 lbs. of Durez 31099 for. a pilot run. We intend to run both bases and covers from this material and will test for process problems as well as the affect of the material on the performance of the circuit breaker..
Procurement of the material, molding of parts and testing will be completed by November 16.
2. Ql Base/Covers - originally molded of asbestos-filled Plenco 509120 flow. Cedar Rapids approved the change to Plenco 548 asbestos- free material on change Report D-508, dated June 7, 1979. Missouri
.. changed to Plenco 548 August 8, 1979. These parts first arrived on the production line September 5, 1979. It was determined at that
. time that Plenco 548 parts are dimensionally unacceptable due to excessive shrink. If the parts are mated with other parts molded of 548, the dimensional difference is not a factor, for both parts will have the same shrink characteristics. But Missouri sandwiches this part with parts of dissimilar material. This.results in alignment problems during assembly and N T I 's on approximately 50 percent of our production.
SQ U A RE p ggMPHNY
fiCE 2
Missouri immediately withdrew the Plenco 548 from production ' . and reinstated Plenco 509-120. We immediately .contacted the
Plenco representative and With his assistance are running tests on parts molded of Plenco 509AF, asbestos-free and Plenco 548. These tests are being performed to determine whether .the amount of .shrinkage incurred can be controlled consistently by changing any or all of the machine or process parameters. To date, none . of-.the changes attempted have proven successful in minimizing the shrink problem.
These experiements will be completed by October 15. If not -successful, -we must qualify another material for this particular application, or standardize on a material other than Plenco
548 in Missouri.
We are presently running both ,the Q2 Base and Cover successfully from Plenco 548. . Shrinkage is high but consistent in both parts, therefore, we are not encountering the problem we do with the Ql Base/cover parts.
' In the meantime we are working with representatives from Plenco, Durez and Reichhold. Plenco is working o n reformulation and other material recommendations. Durez and Reichhold have been requested to make recommendations -
.. General Electric's 4304 is an injection molding material and cannot be used for the Q1 Base/Cover. It also is a more expensive .material than required.
GE1293E is a compression molding.material' presently approved for Q 2 parts. It has never been sampled or tested on Q1 parts. By copy of this letter X am requesting Bruce Wesseldine and Bill Ballin to request information on this material and procure enough material for Missouri evaluation.
With the lead times involved in obtaining information from suppliers, procuring material for samples, and performing tests and evaluating test results, we have made significant progress in these past four weeks. We were fortunate to recognize the problem at an early stage of production.
Our plan is to continue to work with our molding powder suppliers to resolve this one (1) problem part.' Other than for this one part, our conversion to asbestos-free material is progressing smoothly.
eg SQDKVRJJ00706