Document KJOeepyGGo68k1rvG1oL4NEN
PLAINTIFF'S EXHIBIT
Minimum Requirements For Respiratory Protection From Airborne Asbestos
Airborne concentration of asbestos, tremolite, anthophyllite, actinolite, or a combination of these materials
Not in excess of 2 f/cc (10 x PEL)
Not in excess of 10 f/cc (50 x PEL)
Not in excess of 20 f/cc (100 x PEL)
Not in excess of 200 f/cc (1000 x PEL)
Greater than 200 f/cc (> 1000 x PEL) or unknown concentration
Required Respirator
Half-mask air purifying respirator equipped with high-efficiency filters.
Full facepiece air-purifying respirator equipped with high-efficiency filters.
Any powered air-purifying respiratory equipped with high-efficiency filters.
Any supplied-air respirator operated in continuous flow mode.
Full facepiece supplied-air respirator operated in pressure demand mode.
Full facepiece supplied-air respirator operated in pressure demand mode equipped with an auxiliary positive pressure self-contained breathing apparatus.
Note:
Respirators assigned for higher environmental concentrations may be used at lower concentrations.
A high-efficiency filter means a filter that is at least 99.97 percent efficient against monod.ispersed particles of 0.3 micrometers or larger.