Document KJLD0XMJepQZJDN9X0z8qjby6

, Monsanto rnOM (MAMC LOCATION) F. Macdonald - Newport 18th May, 1971 Report 1971 _ FM/SC TO J.R. Savage, St.Louis , A'-'.t- r- cc D.B. Shearn T.W. Dalton WGK D.B. Hosmer S.L P.B. Hodges W. B.Papageorge " E.V. Weekes Bxl H.L. Williams Ann. From October 1970 to April 1971 inclusive, 51 samples of Newport works effluent have been tested for PCB content. The monthly average concentrations of PCB in the works effluent are as shown below:- Average PCB content Equiv. Pounds per day October November December January February March April 151 PPb 263 PPb 12 7 PPb 263 ppb 247 ppb 252 ppb 213 ppb 1.51 2.63 1.27 2.63 2.47 2.52 2.13 Change-over of Santotherm F.R. Heat Transfer Systems The heat transfer system on the Luwas on the 4NDPA plant at present contains Santotherm FR2. It has been decided not to change this over to Santotherm 66 (HB40) because of the potential fire hazard which would be involved and precautions are being taken to minimise and contain any spille or leakages which may occur from this system. The only other Aroclor heat transfer system in use at Newport 1b on the Santolube 900 plant. Change-over of this system to Santotherm 66 is under evaluation, but no change has yet been made. MONS 099005 2. Disposal of PCB Wastes The setting up of a system for disposal of liquid and solid PCB wastes (both from Newport works and customer plants) by incineration is being negotiated with Purle Brothers Haste Disposal. Atmospheric Emission No rls*ults other than the ones reported previously have yet ben obtained on atmospheric emission of PCB. V /I . F. Mai >nald HONS 099006