I. SCOPE AND APPLICATION
This colorimetric test is applicable to the detection of magnesium (XI) and iron (II) from asbestos in bulk samples. These samples include sprayed on asbestos as well as ceiling tiles. The test is simple and can be readily used In the field to screen for the presence or absence of asbestos. The amount of the sample needed for the test is only about the size of a large pea.
II. PRINCIPLE
The te^ is based upon the formation of ^lor complexes with Hg+/ and Fe released from asbestos. The Mg ^fron chrysotile is complexed with p-nitrophenylazo-a-naphthol. The Fe from crocidolite and amosite is complexed with 1, lO-phenanthroline.^A positive+Jest is indicated by the formation of colored complex for Mg and/or Fe , and it indicates possible presence of asbestos.
111. INTERFERENCES The test is a colorimetric spot test for Mg+2 and Fe+2 , and Is not specific for asbestos.
A bulk sample may contain Mg and Fe compounds other than asbestos. Without treating the sample as in the Procedure, a few drops of color forming reagents are added directly to the sample. If either color forms, an interferring substance is present and the sample must be cleaned before the test is conducted to eliminate the interference. In this cleaning process, plaster, mineral wool, fiberglass, and soluble Mg and Fe confounds are removed before the screening test, preventing their Interference.
IV. SENSITIVITY, PRECISION, AND ACCURACY
A sample containing more than 1Z asbestos gives a positive color reaction.
A total of 198 various field samples were tested before the Acid Wash steps were added to the Iron Test procedure. Results are listed be low:
Results of the screening test without the Acid Wash.
No. of Samples
I of Total
True Positive
79
40
False Positive
50
25
True Negative
69
35
False Negative
0
0
LLA 001661
U J*g
3 !**^ IvS
UseiK
f 1 ! i
1 f tM y a
Results of the screening test vith the Acid Wash.
f v ftm 1 1
No. of Samples
Z of Total
True Positive
5
38
False Positive
0
0
True Negative
8
62
False Negative
0
0
V. APPARATUS
1. Teflon dish or white plastic plate 2- Plastic or glass rod 3. Dropping plastic pipet 4. 15 oL disposable plastic beaker 5. 25 aa sire 0>8 pa nixed cellulose ester filter 6. 25 mt size polyvinyl chloride filter ?. 25 9 Svinoex filter holder end gasket B. 10 nL disposable plastic syringe
VI. REAGENTS (Reagent Grade)
1. Phosphoric acid, concentrated.
2. 10 N sodiua hydroxide - Dissolve 40 g of NaOB in 100 nL of water.
3. Mg Reagent - Dissolve 1 ag of p-nltrophenylazo-a-naphthol in 100 iL of 2 H NaOH. Age at leaat a day. This reagent is stable over a aonth.
4. Hydrofluoric add - Dilute 20 nL of HF with 20 nL of water. Add 0.6 ttL of concentrated HC1.
5. Fe Reagent - Dissolve 2 g of 1,10-phenanthroline in 50 nL of ethanol. This Teagent is stable ovci a month.
6. Glycerin, reagent grade.
7. Acetic acid, concentrated glacial.
8. Sulfuric acid, conce. trated.
9. Double de-ionlzed water.
LLA 001662
VH. PROCEDURE
A. Magnesium Test
1. Add a few drops of Mg Reagent directly to the sample. If blue color appears, wash the sample with glycerin before the test. Any sample containing plaster is also washed with glycerin.
Glycerin Wash
a. Place a small portion of sample, about the size of a large pea, in a plastic beaker.
b. Add 5 drops of glycerin and mix well with a plastic rod or spatula.
c. Rinse the plastic rod with a small amount of water into the beaker.
d. Filter the sample through the filtration assembly consist ing of a syringe attached to the Svlnnex filter holder loaded with a mixed cellulose eater filter and a gasket.
e. Filter with a minimum of 5 washings or about 50 mL of water.
f. Transfer the filter to a Teflon dish for the Magnesium test.
2.. Add a drop of H^PO^ and mix well by grinding the sample with a plastic rod.
3. Add 2 drops of 10 N KaOH and mix well.
4. Add 5 drops o Mg Reagent and stir briefly. Note any color change.
5. Add 5 more drops of Mg Reagent and observe the final color.
6. A blue color indicates that chrysotlle may be present.
7. Samples giving a positive teat may be sent to a laboratory for confirmation. If the magnesium test is negative, the sample must be tested for iron.
B. Iron Test
1. Add few drops of Fe Reagent directly to the sample. If a red color appears, wash the sample with the acetic--sulfuric acid mixture before the test. Samples containing fiberglass or mineral wool sre also washed with the acid mixture.
LLA 001663
Acid Wash
1. Place a small portion of the sample, about the size of a large pea, in a plastic beaker.
2. Add 5 drops of concentrated acetic acid. 3. Add 5 drops of concentrated sulfuric acid. 4. Mis well and ultrasooicate if available for 5 minutes.
5. Filter the sample through a polyvinyl chloride filter with a minimum of 5 vashlngs or about 50 mL of water.
6. Transfer the filter to a Teflon dish and proceed with the Iron Test.
2. Add a drop of HF solution and mix veil. 3. Add 5 drops of Fe Reagent and observe the development of red
color. 4. The red color indicates that amoslte or crocldollte may be
present.
C Notes If both parts of the test give negative responses, there is a low probability that any asbestos is present. Once the presence of mag nesium and/or iron is indicated, further analysis, if needed, is done in the laboratory to confirm, identify the type, and quantitate the percentage of asbestos.
VIII. REFERENCE 1. Caution: Asbestos Dust. A scriptographic booklet by Channlng L. Bete Co., Inc., Greenfield, Hass. Prepared in cooperation with U.S. DHEW, PHS, CSC, National Institute for Occupational Safety and Health, Cincinnati, Ohio (1973).
2. Fritz Felgl: Spot Tests - In Inorganic Analysis. Translated by Ralph E. Oesper. 5th Edition. Elsevier Publishing Company, Amsterdam. (1958) p. 225-227.
3. Walter S. Rim, James W, Carter, II, and Richard E. Kupel: Quick Screening Test for Asbestos. D.S. SHEW, PHS, CDC, N10SR, Cincinnati, Ohio. To be published in AIHAJ.