Document KJ65MwRLrMdvovDK4aGwa7QpK

Spectroscopy Method 70-23 Job No. 8903209 DETERMINATION OF CHLORINATED DIBENZOFURANS IN AROCLOR _____________ PRODUCTS INTRODUCTION Low levels of po1ychi or Insted dlbenzofurens have been Indicated in competitive polychlorinated biphenyls (PCB'a), but not In Aroclor. Because of the reported high toxicity of polychlorinated dlbenzofurans, a study was undertaken to determine If these, or related, compounds exist as impurities In our product. PRINCIPLE A direct gas chromatographic determination of theae Impurities Is not possible because of interfering PCB components. However, If the Aroclor Is eluted with hexane through a column containing Florlsil adsorbent, the PCB can be removed, leaving any polar oxygenated compounds adsorbed on the Florlsil. Theae oxygenated materials can then be aluted by a more polar solvent, such aa diethyl ether. A procedure based on these principles la described below. Certain polychlorinated naphthalenes and phananthrenea or anthracenes are also detected by this procedure. REAGENTS AND APPARATUS Hexane - Mallinckrodt Nanograde. Diethyl Ether - Anhydrous Mallinckrodt reagent grade. Two solutions one 5X and the other 25Z by volume, of ether In hexane,were prepared. Florlsil - Fisher, 60-100 mesh, heated at 130*C for 4 hours and stored in a desiccator. Sodium Sulfate - Anhydrous Fisher certified A.C.S. grade, heated at 400*C for 1 hour and stored in a desiccator. Liquid Chromatography Columns - 3.6 cm i.d. X 50 cm long Pyrex with Teflon stopcocks. Gas Chromatograph - A Hewlett-Packard 5750 with a nickel63 electron capture detector. The column is 1/4" X 8' glass, packed with 4Z XE-60 on 80-100 mesh H.P. Chromosorb W, The helium flow rata Is 60 ml/min the 90Z argon, 10Z methane purge flow is 120 ml/ min, and the oven temperature Is 210*C. Mass Spectrometer - A Varlan MAT CH 4B Interfaced with a fritted glass separator to a Hewlett-Packard 5750 gas chromatograph equipped with a flame ionization detector. HONS 213600 Method 70-23 PaB 2 Sample Concentrator - 500 ml Kunderna-Danish evaporative concentrator with a 3-ball Snyder column and a 5 ml receiver (Ace Glassware). EXPERIMENTAL A. Column Preparation A small amount of glass wool la placed In tha bottom of the colunn, which la then half filled with hexane. Next, lSOg of dry Florlsll la poured Into the column and allowed to settle. Three grama of sodium sulfate la added to the top and one liter of hexane la allowed to elute through the column at a flow rate of about 10 ml/min. The liquid level must not be allowed to drop below the top of the packing. The column can be stored until ready for uae aa long as the hexane level la maintained above the packing. B. Column Separation An accurately weighed sample of Aroclor, about 0.5g, la dissolved In 20 ml of hexane and poured onto the head of the column. The bulk of the PCS la eluted with 2500 ml of hexane, using a 10 ml/mln flow rate. This solution la discarded. Noct,800 ml of 5X diethyl ether la eluted through the column and the eluate discarded. Finally, 800 ml of 25X diethyl ether Is eluted. Two successive 400 ml portions are collected, starting as soon as the 25X ether Is added. These 400 ml portions are saved for further characterization. C. Concentration of the Samples Each 400 ml sampla la added to a Kunderns-Danish evaporator. The apparatua la placed In a 90*C water bath and heated until the volume has decreased to about 5 ml. The receiver Is dis connected and the solution Is further concentrated to 1.0 ml by passing purified nitrogen over the surface. Alternatively, the entire concentration can be carried out by evaporation with nitrogen paased over the liquid surface; this Is time consuming and some sample la lost on the container walls. D. Standardization of the Electron Capture GC A 1 ul aliquot of a 1.15 ng/lil solution of 2, 3, 7, 8-tetrachlorodlbenzo-p-dioxln (TCDD) In hexane la Injected Into the GC. The chromatogram la recorded and the height and retention time of the peak la measured. TCDD was used aa a standard because of the lack of a suitable polychlorinated dlbenzofuran standard. HONS 213601 Method 70-23 PaR 3 E. Quantitation An appropriate aliquot (0.5-5 ul) of each concentrated sample solution Is Injected into the electron capture GC. The chromatogram Is recorded and the height snd retention time of each peak is noted. The concentration of each species In the Aroclor, expressed as ppm TCDD, Is Cone(ppm) 1.15 ,, Peak Helght(Unk) ,, Volume In.1 ec t ed (TCDD ) sample Peak Height(TCDD) Volume Injected(Unk) wt (g) Retention Time (Unk) Retention Time(TCDD) F. Id entlfIcatIon Excess solvent is evaporated from the sample so that only about 10 U& remalna. This entire amount la analyzed as one aliquot by GC/MS using standard techniques. The maea spectra of each Aroclor and likely Impuritiea exhibit prominent molecular Ion peaks. The number of chlorine stoma per molecule can be calcu lated from the isotope ratio of the molecular Ion. Components Identified In this manner can be related back to the chromato gram used for quantitation. Polychlorinated naphthalenes and phenanthrenes or anthracenes have also bean observed. We have not verified the quantitation of this procedure for these polynuclear aromatics. db Monsanto Company Organic Chemicals Division Applied Sciences Section 5t. Louis, Missouri 12/70 - J. P. Mieure, M. W. Dietrich HONS 213602