Document KGwK009v69e2vdQ06XBB96N6r

1. IDENTIFY THE S(^fc Feed 1a n likely source Inge being the most probable source ofcontnmmaclnn. It In almost certain If the silage was ` stored In a silo constructed with concrete, staves between I960 and 1972 and was coated with an epoxy coating called CUMAR oc any othor epoxy coating which used "Aroclor 1254" as the plasticizer. Analysis of the silage or scrapings of the silo w all noeds to be made. % 2. STOP FEED1N0 THE CONTAtfTMATED FEED. This is essential. Do not try to salvage contaminated feed by feeding to heifers, dry cows or steers as thn PCB*s will accumulate in the body fat. 3. IF NO FEED OR WATER SOURCE CAN BE FOUND. PCB'S IN HIE MILK ARE FROty BODY STORES COMING FROM FEEDS WHICH WERE FED PREVIOUSLY. 4. DECONTAMINATE rows RY "till,kino-out" TITE PCB'S. HERE is no other method. Using suitablo feeds tuffs, formulate the best milk-producing ration possible without causing a reduction in the percent milk fat. Upon vlthdrawl of the contaminated feed In controlled Intake studies, there was a rapid drop in residue concentration by about 1/2 In 14 to 16 days. This phase was followed by a much slower elimination rate which was described as one percent drop per day of what remained each day. Since there will be unknowns relative to the time and amount of PCR ingestion, cows may already be in the slow elimination phase when rCB's ore detected in the milk, and the rapid drop during the 14-16 days after detection will not occur. Decontamination time will vary according to the level of PCB*# in milk and in body fat and the amount of milk produced dally. A minimum of 60 to 90 days is likely to ho needed for the cow. However in soma herds, decontamination may extend to 9 months or a year. Monitor decontamination rate with milk samples which are two weeks apart. When PCB levels in the bulk tank milk fat are between 3.0 end 4.0 ppm, analysing the milk of each cow offers the possibility in selecting cows which are producing milk below the tolerance level. 5. BEWARE OF FRESH COWS AND FIRST CALF HEIFERS. THEY COULD BE LOADED. Do not market the first milk If herd level is near the toleranco level. 6. REPLACE OR DO NOT USE THE CONTAMINATED SILO UNTIL INNER SURFACE HAS BEEN CLEANED AND RBCOATED. The only certain method^ for Eliminating rcg's in silage is to build a new silo or to replace the staves in tho contaminated nllo. Barrier coating is another alternative but cannot be considered a permanent solution be cause the barrier-coating may coma loose with time. Thus, PCB contamination could occur again. If barrier-coating Is feasible, then extreme care i3 required. All dirt and loose particles of old coatings and/or deteriorating vail surfaces must be removed as the barrier-coating will be no batter than the surface to which it is applied. Sandblasting is an excellent method of cleaning a silo wall ntrrface. When this method Is used, care should bo taken to control dust, debrln, and sand which can spread PCB contamination to other areas of the farm. Washing tho surface with high pressure water (500 psl) has bocn shown to bo an effective method. When this method is used, the run-off must be controlled to prevent TCD contamination of waterways, and time must he allowed for silo walls to dry prior to barrier-coating application. Wire brushing the surface in also effective, but requires a groat deal of time and labor. 0631036 EX P-3189 Page 1 of 4 PCB-ARCH0755253 3 * A special problem i^Rn-ountcrcd when the previous ^Pe*.<g Is still Intact or the silo is constructed of wax-treated blocks. For good bonding, the barrler'coat requires a firm rough surface. Sandblasting tiny ba the best way to remove Intact coatings, go not use organic solvents because It will spread tho PCD contamination and may Icavo the surface unfit for rccoatlng. The barrier-coating must withstand the harsh environment inside the silo. In addition, tho coating should not contain chlorinated hydrocarbons or toxic chemicals which will contaminate the silage (FDA approval for the product is recommended); OSIIA standards for safety of workers applying material from toxic or flammable vapors should satisfied; and coating should not contain a solvent In which PCB's are readily soluble. "Thoroseal" and "Acryl 60" - Standard Dry Wall. Inc.. Miami. Florida which is a barrier-coat using a hydraulic cement containing an acrylic bonder and "Kan-Glas" - Feller Enterprises Inc,, Waukon. Ia. have been shown to be effective barrier-coatings. When using "Kan-Glas" the walls must bo absolutely dry. Materials with similar properties could be used. The use of trades Is to Identify products which were used In research and not meant to endorse them. POTENTIAL Milk Is under constant survellance for chemical residues Including PCB'e which are only one of a number of chemicals screened for In milk supplies. Feed is the most likely carrier. This means that more care needs to be given to knowing the history of all feeds used by dairymen. - Any dairyman who la using a concrete stave silo which was coated with "cumar" Is In jeopardy. If type of coating Is unknown, then silo wall scrapings should be analysed for PCB's. Bo cautious about use of sewage sludge for fertiliser as It may be contaminated with PCB's from industrial sources. It would be good Insurance to document all feed purchases and store sauries of these feeds for at least one year. , Because feeds are & probable source of many contaminants that may cause a dairyman problems. It ie strongly reconmendcd that a two pound sample of every batch of feed ba saved and adequately labeled. This may seem to be another additional management burden but this procedure will bo extremely valuable in determining sources of costly contamination. These samples, if properly stored, can be either discarded or fed. 0691097 EX P-3189 Page 2 of 4 PCB-ARCH0755254 (t)cfwia{ive &cktuvon Met vice I 11112200fyfyfffafa RReeaadd / CCilovlummbbuut,i,OOhhlta k_y________________ 43211 AGRICULTURE/HOME ECONOMICS/NATURAL RESOURCES August 26, 1976 TO: Agricultural Industry Area Supervisors i RE: Reccnmendations for Dairymen with PCB Residues Dear Co-workers: Hie enclosed article was prepared by Dr. Lynn B. Willett, Department of Dairy Science, to be used as a reference while answering PCB questions raised by dairymen. I feel certain the article will be very useful and does answer severed questions dairymen will be asking. . Dr. John Staubus, Dairy Science Department, is the initial contact for extension personnel and dairymen at the state level. Dr. Staubus is coordina ting the Dairy Department PBC educational program. If you have dairymen excluded fran the market, please send the name and address of the dairy farmer to my office. Sincerely, TU/dz Enclosure Ted L. Jones 1/ Assistant Director Agricultural Industry EX P-3189 Page** Of 4 PCB-ARCH0755255 200 FyN* Read Colummebuu>i,, Ohie 43218 AGRICULTURE/HOME ECONOMICS/NATURAL RESOURCES August 4, 1976 To: Agricultural Industry Area Supervisors Subject: Analysis of Silage and Silo Wall Scrapings for PCB's Dear Co-workers: Recently we have received questions from county agents, agriculture and dairy fanners related to PCB's. Many farmers do not know whether or not they have a PCB problem. 1 The enclosed article briefly describes the background of the PCB problem and gives procedures for having silage or. silo wall scrapings analyzed.( Dr. Lynn Willett is the PCB authority in Ohio and he provided the' basic Information in the attached document. Dr. Acie Waldron, Entomology Department is the contact person regarding sampling procedures and sample analysis. ' We expect to have a followup article within approximately two weeks which will provide recommendations for dairy farmers who have determined they have a PCB problem. Sincerely, Glen H. Schmidt Chairman Dairy Science Department TLJ/GHS/dz Enclosure Agricultural Industry 0631292 EX P-3189 Page 4 of 4 Ctllttt *f Aamahan aaJ Hunt htnnmin / tit Oil* Slat* Vnittniij aaJ lit UailtA Slain 0*iartaatai af Atikahan C**i**aiiat PCB-ARCH0755256