Document KGw2z9EkXwG4nZopnzQ5Qkxoo

144 Air Conditioning uaa Butn. Dwuk litCTROMOVE Complete line of ELECTRIC HEATING SYSTEMS for HOME-INDUSTRY-FARM Ptrisha 0f ROCHESTER 3, NEW YORK <OMMCRCtAl CONTROLS CORPORATION When you need advice in any field, you consult a specialist. Deciding on a heating system is an important matter-one that you do not undertake very often. Therefore, it is only natural and in the course of wisdom, that you will look to a specialist in this field. For more than 25 years Electromode has devoted its research engineering and manufacturing facilities predomi nantly to the Hwagn and production of electric space beating equipment, and is one of the oldest in the business. The Safety Grid Heating Element is an Electromode feature. All electric wires are insulated, embedded and completely sealed inside a finned aluminum casting. No exposed hot wires, no glowing coils and no danger of fire, shock, or burn. This finned alumi num mting spreads, the heat rapidly, resulting in higher effi ciency and greater economy. The built-in safety switch auto matically prevents overheating. The Safety Grid Heating Element is guaranteed for 5 years against any defect in material or workmanship. For HOME and OFFICE RS 1 WALL-TYPE HEATERS Electromode Wall-type Heaters are made in models *r>d capacities suitable for all tit* rooms, ranging from 1320 to 4000 watts, with built-in thermostat or man ual control. Heat is fan-circulated at floor level. All have automatic thermal safety switch. The big room heaters hare silver grey finish and can be painted to match decor. The am*il room or bathroom heat ers are available in gleaming chrome or white enamel and are used as complete or auxiliary source of heat. See figs. 1 and 2. Fig. 3 BASEBOARD HEATERS Designed so that a completely harmoni ous installation can be made which con forms to design and dimensions of any room. Matching blank sections, end pieces and comers for carrying out un broken baseboard effect. The comfort of radiant warmth along outer walls, under windows and across the floor, thermo statically controlled at the comfort level you select for each room. There's no in terference from Electromode Baseboard Heaters. They're so out of the way along the walls just like regular baseboard. 00, 900, 1200 watts; 120 or 240 volts. See fig. 3. ---------For INDUSTRY-------- Fig. 4 Fig. 5 RADIANT HEATING PANEL Combines radiant and convection heat ing. Modem design with silver grey fin ish. With or without built-in thermostat. Capacity 1100 watts. See fig. 4. RADIANT CABLE HEAT Coils of cable hidden in ceiling radiate clean heat downward. Each room tem perature controlled by separate thermo stat. Cables are a measured length of special insulated electric wires; water. proof; non-corrosive. Used in plaster, drywall ceilings, or concrete floors. Magic Seal coating prevents streaks on ceiling. See fig. 5. Fig. 6 Fig. 7 UNIT HEATERS Unit Heaters available in Suspension-type and Combination Portable and Suspen sion models. Capacities from 1500 to 45,000 watts. Fine for auxiliary warmth in hard-to-heat areas and for complete heating in outlying buildings. Adjustable louvers for directing fan-circulated heat into working rone. Thermostat control available on all models. See fig. 6 for Suspension and fig. 7 for Portable and Suspension. The Electromode Commer cial and Industrial heater is specifically designed for quick, comfortable, warmth in factory departments, offices, super markets and other areas where its quiet operation is an asset. It is easily portable, or it may be mounted on swivel-type brackets. 5KW--240 volts--single or 3 phase--17,075 Btu. See fig. 8. Fig. 8 Fig. 9 EXPLOSION-PROOF HEATERS Explosion-Proof heaters are specially en gineered for installation in hazardous areas where heat is required and danger of explosion exists. They conform to rigid safety specifications and are fully tested and approved by Underwriter!1 Laboratories for use in areas covered in Class 1. Group D hazardous locations. Used in places where atmospheres contain gasoline, petroleum, naphtha, solvent va pors, natural gas and where flammable gases etc. are made or stored. Convec tion type. Three models range from 2000 to 6000 watts. See fig. 9. BLAST COILS Consists of a bank of Electromode castaluminum heating elements mounted in a 18 gauge formed steel frame having a Fig. 10 Fig. 11 114 in. wide flange with %s in holes on approximately *6 in. centers for mounting to air ducts. Complete wiring diagrams for special applications furnished on re quest. See fig. 10. Electromode Insert Dact Heater (fig. 11) Safety and endurance is inherent in its construction. It was designed as a pack age unit ready for easy installation. The Safety-Grid heating element is your as surance of complete protection against fire, shock or bum. Safety switch auto matically breaks the service to the heater in the event of stoppage of air flow through the heater from any cause. It is an automatic reset type. Engineering help gladly given. For more information, see your supplier or write Dept. HVG-19, Electromode Divi sion of Commercial Controls Corporation. Air Conditioning 145 INDUSTRIAL ENGINEERING AND EQUIPMENT COMPANY 22 Haoley Industrial Court, St. Louis (Rrentwood) 17, Mo. Electric Blast Coil Heaters for Installation in Ducts and in Package Air Conditioners Total and Supplementary Heat Package Units aired to specifications SAVE) Design & layout work YOU / Field time Commercial, industrial, institutional, residential and governmental installations are heated by these pat ented unite. They offer the following advantages: 1. COMPLETE UNIT, ready for installa tion, eliminating design and layout work 2. SIZED TO FIT 3. THERMAL CUT-OUTS, furnished with each unit ... 4. WIDE SIZE RANGE INDEECO UNITS FOR PACKAGE AIR CONDI TIONERS. Write for Bulletin E97P showing 704'sires to fit 20 manufacturers' package units. INDEECO UNITS FOR DUCT-INSTALLATION. Write for Bulletin E97XJ showing 422 sizes. SPECIAL UNITS in both categories furnished at no extra cost. INDEECO Blast Coil Heaters are made to suit your specifications.,.You are not compelled to change your plana to meet our specifications. A FEW EXAMPLES OF USES 1. Primary source of heat 2. Booster, supplementary or. standby auxiliary heating 3. ZONE temperature control 4. Industrial applications (Example: for major oil refinery, seven pumping stations without attendants are heated by INDEECO blast coil heater installations) Literature describes wide range of applications in de-. tail. More than 10,000 specifications on file. WRITE FOR CATALOGS CONSULTATION ON ANY PROJECT WITHOUT CHARGE 22,621 INSTALLATIONS to date 150 to 17,500,000 Watts Typical examples include: StJN-TIMES BUILDING, CHICAGO CADILLAC MOTOR CODETROIT GENERAL FOODS CORPWHITE PLAINS ROCKEFELLER CENTER, N. Y. CITY LOYOLA UN1V., NEW OR- LEANS U. S. EMBASSY OFFICE, HONGKONG I. MAGNIN DEPT. STORE, PALO ALTO, CALIF. ST. LAWRENCE SEAWAY (13. S. AND CANADIAN SIDES) AND OTHERS INDEECO Electric Blast Coil Heater for Package Air conditioners as shipped and ready for installation INDEECO Electric Blast Coil Heater for duct installa tion. Listed by Underwriters Laboratories. Above is part of installation totaling 1,680,000 watte.