Document KGrR2KBkKmaknZ9Y70OqoqQj0
COPIES:
P.B.Proctor-GHO D.H.lyons-GHQ-(3) J.Q.Trice-Research f.T.Petersen-DHQ 0 H. Schlenmer-Waukegan L. L.Trauth -Marrero J. M.Woodvard-Stockton C.Stelchek-Denison / H.F.Rahlen-Long Beach Tile
QUALITY CONTROL DEPARTMENT TRANSITS PIPE DIVISION
JOHNS-MANVXLU5 MANVILLE FACTORY
6ubject: Requested by: Identification:
Asbestos Blue fiber P. T. Petersen Asbestos fiber Specification and Control procedures f. T. Petersen's Letter of 10/9/59
SOMARY:
As requested'In subject letter, McVett testing of Asbestos Blue fiber, 3ubaitted by all locations, were conducted by the Manville pipe Division Control Laboratory.
Two of the five composite samples submitted were tested and the averages of
these tests are being reported.
-'
Where shipments vere divided, only the first samples submitted vere tested.
.. ^. DATA:
- JM Test Method 411:2 (McHett yet Classification);
Ship Name
SS Kvangsl SS Ainee Iykea . S3 Almeria Iykea S3 Golden Bear* J3S-Gorgon
Location Sampled
Stockton Waukegan Waukegan Stockton Long Beach
fiber Type
Date Recd^
Tested at
Manville
*
+14 Mesh fiber Rock
'+28 Mesh
4100 Mesh
-100 Fines
Water Temp.
A Blue iA/a 1/17/a 70.1 0-3 2.3 2.2 25.1 48 A Blue 1/5/a 1/10/61 69.5 0.2 2.9 2.8 24.6 50* A Blue 1/5/a 1/17/a 69.U 0.2 2.6 3-2 24.6 48* A Blue 2/l4/6l 2/16/60 68.3 0.0 2-5 2.0 27.2 A Blue 2/15/a 2/15/60 70.1 0.1 2.9 2.a 24.4 46*
CO
Passes Tentative Specifications See V. L. VanDerbeek's Letter Dated 2/20/61 (Transhipped from SS Kvang Tung)
purchase Specifications Minimum Maxlaua
69.0
3.O
25.O
r.
APPROVED BY:
7. Hardenstein