Document KGX1yjmN3ODL9NyxjoaB1jk40
/ BCCi
BaaoNus
V.
July 6, 1970
Kr. D. K. Cavanaugh Espey Manufacturing Ooag>any T. 0. Box *22 Saratoga Spring*, He* Tork 12666
Dear Kr. Cavenaught
L*>C aonth when Randy Orahaa And I visited jour plant to discuss the ?CS protolew, we did not Intand to cause undue alarm or orAt any panic concerning the via* and handling of polychlorinated biphenyls. Ve war* prlsarlly interested In aharing our currant knowledge of th altuatlon with you and offared to help lherever wa oould.
All atudlaa that we at* avar* of Indicate that PCB'a, itfxich are present In Monsanto's Aroolore, are not acuta poison* to humans and other --sis, but do effaot soae speelea of birds and marine life. However, slnoe they are chlorinated hydrocarbons, personnel working with these materials should be protested from prolonged breathing of the fumes and froa skin oontaet with the liquid. Tentllatlon should be provided to ksep the concentration in the working ares below 0.5 - 1.0 milligram per eublo aeter of air.
To prevent the escape of PCB'a to the environment eel Is for a level of eontrol and housekeeping aany ef ue have never been asked to sohleve In the past,
every effort must be asde to prevent leakage and
spillage. Maintenance must be kapt at a vary high standard. For those areas tdiere leakage snd spills will occasionally occur, catch pans wuat be provided. Those pan* eust drain to a oolleoting basin or be emptied by responsible employees on a scheduled basis.
05W 018254
HARTOLDMON0034740
-2-
jtlxing of Aroalors with niti water streams should be avoided since separation or FCB's rroa watar can be costly. If airing cannot b avoided, a catch
baa in and settling pood should be provided to separate tha heavy Arodor Froa tha watsr.
Unusable contaminated Arcelor should ba dlsposad by
incineration which assures oonplete dasti-uction to
COo, K^O* and IC1. Any incineration balow 300C will result in vaporisation which will oontaainata
the ataoaphara or in partial oxidation whlah aay yield aatarlals itileh are highly toxic.
To halp our customers with thalr liquid disposal
probleoa, wa hare orfarad to aocapt for rutura Inclnaratlon sorap liquid Aroolors shipped to Monsanto
Coegisny, V. 6. J^uoariah riant, Seuget, nil nola, Attantlon Sig>ervisor, Department 2*c. The ahargo
ror this disposal is 24 P* pound or aatarlal. This chars# 1> tentative pandins a oooplate evaluation or Incineration coats and does not include Freight
or container costs.
Contamination or tha ataosphare wust also be elimi nated. All handling aysterna must be closed ldjerevtr possible. Fumes axhauatad From a tank, vessel, or
workir* arta nuat be trapped and collected using oondensers and entrainment separators.
Solids contaminated with FCB's pose a greater challenge. Until a proper lnclnarmtor la designed we are av^geeting that disposal be made in an authorised, properly operated land rill away fro*
uxj water aytarns. These solids Include treatment clays, absorbing aatarlal a used to contain spills, rags, windings and 000taldots.
In suasary, control or FCS's can be achieved with
equipment engineered to prevent losses and aain-
talaed properly coupled with good ssnurseturing
prseticec idilcn recult in s high standard or house
keeping.
*
froa the interest and concern ehlob you have expressed I u certain that you will do all you can to reduce the eaeape of FCS's from your operation. When all or
us succeed in this objective, I sa certain that no regulatory agency will be compelled to take precipitous
action regarding the use of FCB's in vital applications.
cc: Q.M.Qraham
Sincerely,
Orjmil SifnttJ by W. B. P>piM,l*
V. B. TXFAOSenas, Manager Environmental Control
OSH 018255
HARTOLDMON0034741