Document KGVawKgrOjNebQdxzGBZjgkyo
W. R. Grace a Co.
INDUSTRIAL CHEMICALS OROUR St WHITTCMORE AVt,CAMB(*ID0l,MA*.0l*0
,October 9 1969
Nr. James Cintaal, District Manager Zonolite
Construction Products Division W. R. Grace & Co. P.0. Box 2124 Trenton, New Jersey 08619
Dear Jim:
In reply to your Inquiry as to possible health hazards associated with mixing and application of Mono-Kote, please be advised as follows:
On September 12, 1966, studies were made of the operations involving application of Mono-Kote at the building construction site of the Beverly Hills High School, Beverly Hills, California. The studies were conducted by the California Department of Public Health, Bureau of Occupational Health and Environmental Epidemiology at the request of the California Department of Industrial Relations, Division of Industrial Safety.
Work atmospheric exposures to the Mono-Kote mixture were evaluated by collecting air samples simultaneously by two different methods: with allglass midget lsplngers and with high volume filter paper samplers. The
lmplnger samples were analyzed for dust concentration by count, using the standard light field technique, recommended by the American Conference of
Hygienists: High volume sasples were analyzed by weight, by echnlques. All sanples were taken at the operator's breathing zone during two different normal work procedures; Indoor spray application and outdoor hatch mixing. Material seuqples of dry Mono-Kote mixture and wet slurry were collected directly from a hag and from the discharge of the pneumatic spray gum, respectively. These were analyzed for asbestos con tent by the X-ray diffraction technique In the Sir and Industrial Hygiene Laboratozy of the State Department of Public Health. Results of the studies were as follows:
Composition of Material Saaples
Sample No.
Location and Type of Sample
Asbestos Content-4
1 Dry mix, directly from bag of Mono-Kote
11
2
Wet slurry, directly from
less than
pneunatibspray gun':,
1
MCH0-M& ^r Atmospheric Concentration of BodOrt** W Dust
34552
Location
1. a. Inside bldg, on scaffold, 1 man
b. Inside bldg, on scaffold, 1 man
Av. exposure
Peak exposure
Operation
Applying Monocote by spray gun
Applying Monocote by spray gun
Atmos. Cone. nppcf^ S/M3'2)
1.0 2.8& 6.2
0.75 & 0.70
3.1 & 5.8
0.8 4.5 1.0 6.2
Remarks
OBZ normal operation, nozzle at medium speed
OBZ, normal operation, nozzle at medium speed
2.Outside bldg, by mixer hopper, 1 man
Av. exposure
Peak exposure
Loading hopper with 4 batches of Monocote
Hygienic Standards for Asbestos Dust (count basis) threshold Limit Value (av.)^
Threshold Limit Value (peak)
0.7 & 1.4
1.4 8s 9-9
1.2 5?7 1.4 9-9
OBZ, normal operation low wind condition
2.0 5-0
Suggested TLV (weight basis) (greater than 5# asbestos)
0.3
(1) mppcf - million particles per cubic foot of air (2) mg/M^ - milligram per cubic meter
(3) OBZ - Operator1 s breathing zone
Page (V)
October 9, 1969
34553
For several years past, the Threshold Limit Value (TLV) for asbestos fibers, as set by the American Conference of Governmental industrial Hygienists (ACGOH), has been five million particles per cubic foot of alr/jfjppcf). The ACGIH now recommends a lower time-weighted TLV on a count basis of 2 mppcf, with a"ceiling" TLV of 5 mppcf*
The 0.3 mg M^ TLV for dusts greater than 5$ asbestos, as arbitrarily sugges ted In the report, is the weight-basis TLV for pure silica dust. No wieghtbasis for asbestos fibers has been established.
The studies conducted by the State of California showed that total asbestos fibers in air at the operations Involving mixing and application of Mono-Kate was well below the TLV established by the American Conference of Governmental Industrial Hygienists.
If I may be of any further help, please advise.
Sincerely yours,
Peter Kostlc Safety Administrator