Document KG7LRL82XnzrKe9rMaNoR84XQ

><T& 'e 1 IN 1971 MONSANTO DISCONTINUED SALE OF PCB-CONTAINING PRODUCTS TO THE FOLLOWING MAJOR APPLICATION AREAS: -CARBONLESS PAPER -FIRE RESISTANT HYDRAULIC FLUIDS -HEAT TRANSFER -PLASTICIZER HONS 035545 THERE WERE NUMEROUS MINOR ADDITIONAL APPLICATIONS DISCONTINUED AT THE SAME TIME. MONS 035546 SALES IN THESE AREAS FELL FROM 32.5M LBS. IN 1970 TO 752,000 LBS. IN 1972 and 0 IN 1973. MONS 035547 IN 1975 WE CONTINUE TO SELL TO THE ELECTRICAL INDUSTRY FOR INCLUSION IN CAPACITORS, TRANSFORMERS AND ASSOCIATED CLOSED ELECTRICAL EQUIPMENT BECAUSE - HONS 03554ti 5 1. UTILITY - THE AROCLOR FLUIDS PERFORM AN ESSENTIAL ROLE IN ELECTRICAL DISTRIBUTION. 2. LACK OF EFFECTIVE PROVEN REPLACEMENT. 3. OUR BELIEF THAT USE IN CLOSED SYSTEMS IS CONTROLLABLE. HONS 035549 MONSANTO CURRENT MARKETING POLICY - PCB X. SUPPLY ONLY MANUFACTURERS OF SEALED ELECTRICAL EQUIPMENT SUCH AS CAPACITORS/TRANSFORMERS. 2. DO NOT RECLAIM ELECTRICAL FLUIDS. 3. OFFER INCINERATION SERVICE FOR LIQUID PCB WASTES. 4. CONTINUE RESEARCH PROGRAM (STARTED 1969) TO DEVELOP EFFECTIVE REPLACEMENTS. 5. ENSURE THAT SIGNIFICANT DIFFERENCES BETWEEN AROCLOR DIELECTRICS AND REPLACEMENT CANDIDATES ARE FULLY REVIEWED. MONS 035550 UTILITY IN CAPACITORS PROPERTY FUNCTION FIRE RESISTANCE ------------------ > CONSUMER/PLANT SAFETY THERMAL STABILITY CHEMICAL STABILITY -- . HYDROLYTIC STABILITY POWER FACTOR ) RELIABILITY DIELECTRIC CONSTANT DIELECTRIC STRENGTH t AVAILABILITY * CONVERTABILITY ECONOMY HONS 035551 UTILITY IN TRANSFORMERS FIRE RESISTANCE - SAFETY THERMAL/CHEMICAL STABILITY - RELIABILITY HUNS 035552 9 TRANSFORMER APPLICATIONS 1. RAILROAD TRANSFORMERS - RAPID TRANSIT SYSTEMS. 2. URBAN SUBSTATIONS. 3. INDUSTRIAL LOAD CENTERS. 4. ELECTROSTATIC PRECIPITATORS. HONS 035553 FIRE RESISTANCE OF ASKAREL TRANSFORMERS 1. FIRE INITIATION. 2. ARC FORMED GASES. 3. FIRE PROPAGATIONS. MONS 0355S4 11 potential substitutes CAPACITORS RESEARCH OBJECTIVES 1. MATCH OR EXCEED AROCLOR 1016 CAPABILITY. A) DIELECTRIC CONSTANT DIELECTRIC STRENGTH AVAILABILITY CONVERTABILITY B) STABILITY POWER FACTOR C) SAFETY _ RELIABILITY _ FIRE RESISTANCE 2. IMPROVE FURTHER-ENVIRONMENTAL COMPATIBILITY. J. A) SPAN EXISTING APPLICATIONS - COMPLETE SOLUTION. B) INTERNATIONALLY AVAILABLE - NOT SOLELY USA SITUATION. HONS 035555 I 1. DICHLORQBIPHENYL TYPE. 2. COULD BE SUI JTED FOR AROCLOR 1016. SLIGHTLY LESS FIRE RESISTANT. 4. FURTHER DEVELOPMENT CONTINGENT ON INDUSTRY/GOV^RNMENT/PUBLIC/MONSANTO CONCLUSIONS/pN DIFFERENCE IN PCB HOMOLOGUES/ 12 HONS 035556 13 THE CAPACITOR INDUSTRY IS CURRENTLY EXAMINING MCS 1238 MCS 1588 MCS 1475. 1, THESE CONTAIN NO CHLORINATED BIPHENYL. 2 ALL THESE REPRESENT A SINGLE CONCEPT. HONS 035557 THE ADDITION OF A LIMITED QUANTITY OF VERY HIGH DIELECTRIC CONSTANT FLUID TO A GOOD DIELECTRIC BASE LIQUID TO GIVE A DIELECTRIC MIXTURE "EQUIVALENT" ELECTRICALLY TO AROCLOR 1016. MONS 035558 15 1. MCS 1238 HYDROCARBON + SULFONE. 2. MCS 1588 = HYDROCARBON + SULFONE. 3. MCS 1475 = PHTHALATE ESTER + SULFONE. THE MAIN THRUST TODAY IS TOWARDS PRODUCTS 1 & 2. MQNS 035559 PROPERTY DK 25C 100C CORONA IV/EV AROCLOR 1016 5.9 4.85 INDUSTRY HYDROLYSIS STABILITY* (NEUTRALIZATION NUMBER) DISSIPATION FACTOR. FLUID TAN 8 60H2 100C DISSIPATION FACTOR.MODEL CAPACITOR 0.00 0.0025 0.0034 MCS 1238 6.0 5.1 INDUSTRY 0.00 0.05 0.0039 MCS 1588 6.1 5.1 INDUSTRY 0.00 0.05 0.0035 FLASH PT.1 F FIRE PT. F. AIT, *F. FIRE RESISTANCE AKOCLOR 1016 MCS 1238 358' 303' NONE TO BOILING PT. (620) 328 1185' 835' MCS 1588 325 350' 870' HONS 035561 CONCLUSION MONSANTO CANDIDATES ARE NOT FIRE RESISTANT. 035562 HONS ENVIRONMENTAL CONSIDERATIONS EXPOSURE BIODEGRADATION ACCUMULATION TOXICITY WORKER SAFETY ENVIRONMENTAL IMPACT HONS 035563 % BIODEGRADATION SCAS. 48 HR. AROCLOR 1254 15 AROCLOR 1016 33 MCS 1238 78 HYDROCARBON 90 SULFONE 52 160 HR. s jpm JPM 86 90 78 HONS 035564 25 RAT TISSUE RESIDUE (JPM) HONS 035565 HONS 035566 TOXICITY STUDIES -MCS 1238 IN-PLANT HANDLING 1. RAT - ACUTE SINGLE ORAL DOSE LD50 - 3800 MGS/KG. 2. eye iIrritation - rabbit - 12.0/110.0 NORMAL AFTER 72 HOURS. 3. RABBljr - DERMAL LD50 - 5.0-8.0 GMS PER KILOGRAM. 4. RABBIT - SKIN IRRITATION (24 HR. CONTACT) - 3.6/8.0. HONS 035567 ENVIRONMENTAL IMPACT 1 DEGRADATION 2 ACCUMULATION 3. FISH TOXICITY - 4 DAY STATIC STUDY - 96 HOUR LC50 RAINBOW TROUT - 2.0 PPM BLUE GILL - 3.2 PPM HONS 035568 MCS 1238 - FURTHER PROGRAMS SCHEDULED 1. VAPOR INHALATION. 2. ULTIMATE DEGRADATION. 3. ARC GASES. 4. PILOT FEEDING STUDY. 5. LONG-TERM (2 YEAR) FEEDING STUDIES. 6. FISH TISSUE RESIDUES. HONS 035569 STAGE T CAPACITOR REPLACEMENT 23 MONSANTO SCREEN (ELEC) ___A.SELECT MULTIPLE FLUID 7 B.SCREEN(TOX.) PRELIM. BROADEN ENVIRONMENTAL SCREEN INDUSTRY AGENCIES o z > w vr \ MULTIPLE APPLICATION SCREEN CONSIDER SAFETY ASPECTS TRANSFORMERS WE HAVE NOT DEVELOPED ANY MATERIAL WITH EQUIVALENT FIRE RESISTANCE TO AROCLOR. A. PROTECTION UNDER TRANSFORMER FAULT CONDITIONS. B. ARC FORM GASES C. POTENTIAL SPREAD OF EXTERNAL FIRE. MGNS 035571 WE IX? HAVE CANDIDATES WITH INTERMEDIATE FIRE RESISTANCE HONS 035572 PROPERTY MCS MCS MCS HONS 035573 OUR MAJOR OBSTACLE ABSENCE OF OBJECTIVE STANDARDS TO GUIDE POTENTIAL FLUID SUPPLIER TRANSFORMER PRODUCERS TRANSFORMER USERS INSURANCE GROUPS SAFETY ORGANIZATIONS GOVERNMENT AGENCIES ON REQUIRED LEVEL OF FIRE RESISTANCE. MONS 0355?**