Document KG7LRL82XnzrKe9rMaNoR84XQ
><T& 'e
1
IN 1971 MONSANTO DISCONTINUED SALE OF PCB-CONTAINING PRODUCTS TO THE FOLLOWING MAJOR APPLICATION AREAS:
-CARBONLESS PAPER -FIRE RESISTANT HYDRAULIC FLUIDS -HEAT TRANSFER -PLASTICIZER
HONS 035545
THERE WERE NUMEROUS MINOR ADDITIONAL APPLICATIONS DISCONTINUED AT THE SAME TIME.
MONS 035546
SALES IN THESE AREAS FELL FROM 32.5M LBS. IN 1970 TO 752,000 LBS. IN 1972 and 0 IN 1973.
MONS 035547
IN 1975 WE CONTINUE TO SELL TO THE ELECTRICAL INDUSTRY FOR INCLUSION IN CAPACITORS, TRANSFORMERS AND ASSOCIATED CLOSED ELECTRICAL EQUIPMENT BECAUSE -
HONS 03554ti
5
1. UTILITY - THE AROCLOR FLUIDS PERFORM AN ESSENTIAL ROLE IN ELECTRICAL DISTRIBUTION.
2. LACK OF EFFECTIVE PROVEN REPLACEMENT. 3. OUR BELIEF THAT USE IN CLOSED SYSTEMS
IS CONTROLLABLE.
HONS 035549
MONSANTO CURRENT MARKETING POLICY - PCB X. SUPPLY ONLY MANUFACTURERS OF SEALED ELECTRICAL
EQUIPMENT SUCH AS CAPACITORS/TRANSFORMERS. 2. DO NOT RECLAIM ELECTRICAL FLUIDS. 3. OFFER INCINERATION SERVICE FOR LIQUID PCB WASTES. 4. CONTINUE RESEARCH PROGRAM (STARTED 1969) TO DEVELOP
EFFECTIVE REPLACEMENTS. 5. ENSURE THAT SIGNIFICANT DIFFERENCES BETWEEN AROCLOR
DIELECTRICS AND REPLACEMENT CANDIDATES ARE FULLY REVIEWED.
MONS 035550
UTILITY IN CAPACITORS
PROPERTY
FUNCTION
FIRE RESISTANCE ------------------ > CONSUMER/PLANT SAFETY
THERMAL STABILITY
CHEMICAL STABILITY -- . HYDROLYTIC STABILITY POWER FACTOR
) RELIABILITY
DIELECTRIC CONSTANT DIELECTRIC STRENGTH
t AVAILABILITY * CONVERTABILITY
ECONOMY
HONS 035551
UTILITY IN TRANSFORMERS FIRE RESISTANCE - SAFETY THERMAL/CHEMICAL STABILITY - RELIABILITY
HUNS 035552
9
TRANSFORMER APPLICATIONS 1. RAILROAD TRANSFORMERS - RAPID TRANSIT SYSTEMS. 2. URBAN SUBSTATIONS. 3. INDUSTRIAL LOAD CENTERS. 4. ELECTROSTATIC PRECIPITATORS.
HONS 035553
FIRE RESISTANCE OF ASKAREL TRANSFORMERS 1. FIRE INITIATION. 2. ARC FORMED GASES. 3. FIRE PROPAGATIONS.
MONS 0355S4
11
potential substitutes
CAPACITORS
RESEARCH OBJECTIVES
1. MATCH OR EXCEED AROCLOR 1016 CAPABILITY.
A) DIELECTRIC CONSTANT DIELECTRIC STRENGTH
AVAILABILITY CONVERTABILITY
B) STABILITY POWER FACTOR
C) SAFETY
_ RELIABILITY _ FIRE RESISTANCE
2. IMPROVE FURTHER-ENVIRONMENTAL COMPATIBILITY.
J. A) SPAN EXISTING APPLICATIONS - COMPLETE SOLUTION. B) INTERNATIONALLY AVAILABLE - NOT SOLELY USA SITUATION.
HONS 035555
I
1. DICHLORQBIPHENYL TYPE.
2. COULD BE SUI
JTED FOR AROCLOR 1016.
SLIGHTLY LESS FIRE RESISTANT.
4. FURTHER DEVELOPMENT CONTINGENT ON INDUSTRY/GOV^RNMENT/PUBLIC/MONSANTO CONCLUSIONS/pN DIFFERENCE IN PCB
HOMOLOGUES/
12
HONS 035556
13
THE CAPACITOR INDUSTRY IS CURRENTLY EXAMINING MCS 1238 MCS 1588 MCS 1475.
1, THESE CONTAIN NO CHLORINATED BIPHENYL. 2 ALL THESE REPRESENT A SINGLE CONCEPT.
HONS 035557
THE ADDITION OF A LIMITED QUANTITY OF VERY HIGH DIELECTRIC CONSTANT FLUID TO A GOOD DIELECTRIC BASE LIQUID TO GIVE A DIELECTRIC MIXTURE "EQUIVALENT" ELECTRICALLY TO AROCLOR 1016.
MONS 035558
15
1. MCS 1238 HYDROCARBON + SULFONE. 2. MCS 1588 = HYDROCARBON + SULFONE. 3. MCS 1475 = PHTHALATE ESTER + SULFONE. THE MAIN THRUST TODAY IS TOWARDS PRODUCTS 1 & 2.
MQNS 035559
PROPERTY DK 25C
100C
CORONA IV/EV
AROCLOR 1016 5.9 4.85
INDUSTRY
HYDROLYSIS STABILITY* (NEUTRALIZATION NUMBER)
DISSIPATION FACTOR. FLUID TAN 8 60H2 100C
DISSIPATION FACTOR.MODEL CAPACITOR
0.00 0.0025 0.0034
MCS 1238 6.0 5.1 INDUSTRY
0.00 0.05 0.0039
MCS 1588 6.1 5.1 INDUSTRY
0.00 0.05 0.0035
FLASH PT.1 F FIRE PT. F. AIT, *F.
FIRE RESISTANCE
AKOCLOR 1016
MCS 1238
358'
303'
NONE TO BOILING PT. (620)
328
1185'
835'
MCS 1588 325 350'
870'
HONS 035561
CONCLUSION MONSANTO CANDIDATES ARE NOT FIRE RESISTANT.
035562 HONS
ENVIRONMENTAL CONSIDERATIONS
EXPOSURE
BIODEGRADATION
ACCUMULATION TOXICITY
WORKER SAFETY ENVIRONMENTAL IMPACT
HONS 035563
% BIODEGRADATION
SCAS.
48 HR.
AROCLOR 1254
15
AROCLOR 1016
33
MCS 1238
78
HYDROCARBON
90
SULFONE
52
160 HR. s jpm JPM
86 90 78
HONS 035564
25 RAT TISSUE RESIDUE (JPM)
HONS 035565
HONS 035566
TOXICITY STUDIES -MCS 1238 IN-PLANT HANDLING
1. RAT - ACUTE SINGLE ORAL DOSE LD50 - 3800 MGS/KG. 2. eye iIrritation - rabbit - 12.0/110.0
NORMAL AFTER 72 HOURS. 3. RABBljr - DERMAL LD50 - 5.0-8.0 GMS PER KILOGRAM. 4. RABBIT - SKIN IRRITATION (24 HR. CONTACT) - 3.6/8.0.
HONS 035567
ENVIRONMENTAL IMPACT
1 DEGRADATION
2 ACCUMULATION
3. FISH TOXICITY - 4 DAY STATIC STUDY - 96 HOUR LC50 RAINBOW TROUT - 2.0 PPM BLUE GILL - 3.2 PPM
HONS 035568
MCS 1238 - FURTHER PROGRAMS SCHEDULED 1. VAPOR INHALATION. 2. ULTIMATE DEGRADATION. 3. ARC GASES. 4. PILOT FEEDING STUDY. 5. LONG-TERM (2 YEAR) FEEDING STUDIES. 6. FISH TISSUE RESIDUES.
HONS 035569
STAGE
T
CAPACITOR REPLACEMENT 23
MONSANTO
SCREEN (ELEC) ___A.SELECT MULTIPLE FLUID 7 B.SCREEN(TOX.)
PRELIM.
BROADEN ENVIRONMENTAL SCREEN
INDUSTRY
AGENCIES
o z > w vr
\ MULTIPLE APPLICATION SCREEN
CONSIDER SAFETY ASPECTS
TRANSFORMERS WE HAVE NOT DEVELOPED ANY MATERIAL WITH EQUIVALENT FIRE RESISTANCE TO AROCLOR. A. PROTECTION UNDER TRANSFORMER FAULT
CONDITIONS. B. ARC FORM GASES C. POTENTIAL SPREAD OF EXTERNAL FIRE.
MGNS 035571
WE IX? HAVE CANDIDATES WITH INTERMEDIATE FIRE RESISTANCE
HONS 035572
PROPERTY
MCS
MCS
MCS
HONS 035573
OUR MAJOR OBSTACLE ABSENCE OF OBJECTIVE STANDARDS TO GUIDE
POTENTIAL FLUID SUPPLIER TRANSFORMER PRODUCERS TRANSFORMER USERS INSURANCE GROUPS SAFETY ORGANIZATIONS GOVERNMENT AGENCIES ON REQUIRED LEVEL OF FIRE RESISTANCE.
MONS 0355?**