Document KG3Rak8GzpBa6ZXwGvR8RLgd2

' UNja)N carbide corporation Specialty Chemicals Sistersville Plant MEMORANDUM TO: PROM: DATE: SUBJECT: COPY TO: R. E. Crum C. A. McNeill K. B. Purintan W. V. Summers G. W. Wulfert T. L. Grittie February 26, 1986. Results of Qualitative Analysis Of Lint Vogue-Swift D. A. Boggs Attached, please find the results of the qualitative analysis for asbestos performed on the samples of lint removed from the Vogue-Swift washing machines. Please note that a small amount of asbestos was indeed found. This information leads me to recommend that we continue to provide laundering services to the insulators when they are working with asbestos. This service provides the vital function of preventing a man from possibly contaminating his family by carrying asbestos home on his clothing. In addition, laundry bags containing these clothes should continue to be labelled as asbestos contaminated so as to provide adequate warning to the employees of Vogue-Swift. If you have any questions on the results or recommendations, feel free to call me at 521. Sincerely, UCC 007230 j tO % i-i a Cl f-I \to \(N \ (M Z O H c uM CMu E-i Z W OM (Z W CHO Ut C oH P nJ Vi O a n o u 0) o -i-f JuO Xi o nj (0 U f4ZJ c oH O13' e D 4J a (U rl H o UCC 007231 Copies 10 - ( KEMRON ENVIRONMENTAL SERVICES BORS-WARNER CORPORATION INTER-OFFICE CORRESPONDENCE natt, February 12, 1986 Subject Asbestos Content -- Sample 5610696_________ To _ Sarah Vandenberg _ Location Wil I iamstown From -- Ron Huttie _ Location Huntington Analyses was performed using polarized light microscopy in accordance with EPA (Environmental Protection Agency) methods. Since the sample consisted of fragments of many different bulk materials; a qualitative analyses was performed. (A quantitative percentage for each component is not given). The results list the types of fibrous and nonfibrous components present In the sample. ( I UCC 007232 Q> >0 ! INDUSTRIAL HYGIENE MONITORING DATE: PROJECT: June 30, 1987. Monitor insulator for asbestos exposure while stripping insulation using a glove bag. Second level Rectification Tower - Silanes. DATE OP SAMPLES: 4/21/87 SUMMARY: SAMPLE TYPE TIME START TIME STOP MINUTES VOLUME C0NC. PEL Z-9208 BZ 11:07 11:30 23 92 1 <0.05 fibers/ cc 0.2 f/cc A = Airline ,-^BZ = Breathing Zone RECOMMENDATIONS: Share this information with insulators. DISCUSSION: The insulator's exposure was well below the TWAg of 0.2 fibers/cc for asbestos. Continue using proper procedure. METHOD OF ANALYSIS: DATA AND REPORT BY: Microscopy " C. R. McMillan/T. L. Grittie f ANALYSIS BY: JHM Lab8 COPY TO: D, G. Beddow, D. A. Boggs, A. A. Gosper, E. L. Doerflein, J. K. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Summers, G. H. Wulfert. RESP? A TLG/le 5 605A UCC 007233 INDUSTRIAL HYGIENE RESULTS .DATE: PROJECT: DATE OF SAMPLES: SUMMARY: July 1, 1987. Monitor K-57 area and personnel in area for exposure to asbestos. Painters had used air to blow dirt off of the top of ventilation ductwork in preparation for painting to be done. IH took a bulk sample of material which had been blown off the ductwork. Upon analysis, it was determined that the sample contained a small amount of asbestos. According to Poly II operators, the area had been quite dusty while the painters were working. After IH had been called, the painters were told to stop the operation. 4/23/87 to 4/24/87 SAMPLE Z-9218 DATE 4-23 TYPE Area TIME START STOP 11:05 13:00 MINUTES RESULTS 115 CO. 01 f/cc COMMENTS Desk at SW wall near K-57. Kettlehouse No one in area. Z-9219 4-23 Area 11:08 13:00 112 0.005 f/cc Near K-57 handhole. N one in area Z-9220 4-23 BZ 13:00 18:00 300 0.10 f/cc Insulator performing cleanup of K-57 area Z-9206 4-24 Area 00:10 8:25 Z-9207 4-24 BZ 9:54 10:50 BZ = Breathing Zone 495 56 <0.005 f/cc After cleanup completed. On breaker box at wall of kettle area <0.004 f/cc Operator performing regulator duties at K-57. Protective equipment was worn. DISCUSSION: , All samples show concentrations below both the TWAg and the TWA^* Sample Z-9220 was taken during cleanup and is at the action level of a TWAg. The insulator wore protective clothing and an airline respirator. Samples Z-9206 and Z-9207 were taken after cleanup completion and priority analyzed to determine if the area was cleaned adequately to allow entry. The results of analysis were communicated over the phone and at approximately 2:00 p.m. on the 24th the area was opened for entry. UCC 007234 ECOMMENDATIONS: METHOD OP ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Before air is used on dusty areas it should routinely be checked for asbestos content to avoid similar situations in the future. If anyone suspects asbestos in a dusty area I.H. should be called immediately. Share these results with all affected personnel. Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. A. Boggs, E. L. Doerflein, J. K. Kyle, D. L. Mullins, K. B. Purinton, R. D. Smith, W. V. Summers, G. W. Wulfert. 5619A C UCC 007235 U)i/,o->>of>2 INDUSTRIAL HYGIENE MONITORING DATE: 6/30/87 PROJECT: Routine area monitoring for asbestos on first level of Rectification Tower (N.W. side) in Silanes. DATE OF SAMPLES: 4/1/87 SUMMARY: SAMPLE TYPE TIME START STOP MINUTES FLOW RATE VOLUME CONC. 2-9149 Area 13:36 16:15 159 4000 636 1 40.008 cc/min. RECOMMENDATIONS: Share this information with area personnel. PEL TWA12 0.133 f/cc DISCUSSION: The concentration of asbestos in the Rectification Tower during the sampling period was well below the TWA12 PEL of 0.133 f/cc. METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: Microscopy C. R. McMillan/T. L. Grittie JHM Labs COPY TO: D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter. TLG/le 5607A UCC 007236 INDUSTRIAL HYGIENE RESULTS ^aTE: SUBJECT: DATE OF SAMPLES: SUMMARY: SAMPLE TIME START STOP Z-8969 Z-8970 9:50 9:52 DISCUSSION: 12:52 12:52 RECOMMENDATIONS: METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: June 30, 1987. Monitor UCC Design and Construction insulators for exposure to asbestos during removal using a glove bag. In Polymers I tank farm in area outside, behind 8" mill. 2/13/87 TOTAL (Min.) FLOW RATE VOLUME TYPE RESULTS 182 180 3900 cc/min 4000 cc/min 709.8 1 720 1 BZ BZ 0.22 f/cc 0.09 f/cc During the three hour sample period one of the insulators (sample #Z-8969) exceeded the TWAg permissible exposure limit of 0.2 fibers per cubic centimeter of air. Protective clothing and Comfo II half-face respirators with HEPA filters were worn. The respirators were more than adequate to protect against these fiber concentrations. Wet methods were used. The area in which the work was being performed was a small, cramped corner with little room for free movement. This may have contributed to the above results. PEL 0.2 f/cc 0.2 f/cc Use caution when removing asbestos using the glove bag method. Wet methods of removal must be stringently enforced even when used in glove bags. Continue wearing respiratory protection when using the glove bag method. Continue IH monitoring. Inform insulators of the results of these tests. Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. A. Boggs, J. E. Boley, E. L. Doerflein, T. K. Ioannou, K. B. Purinton, L. P. Smith, S. M. Walker, G. W. Wulfert. C 5598A UCC 007237 [O^o-y^o INDUSTRIAL HYGIENE RESULTS DATE: PROJECT: DATE OF SAMPLES: July I, 1987. Monitor area near exposed asbestos on vertical line on fourth deck of east side of Rectification tower, Silanes. 4/29/87 SUMMARY: SAMPLE Z-9223 TYPE Area TIME START STOP 9:38 16:04 MINUTES 386 RESULTS < 0.003 f/cc DISCUSSION: The sample pump was placed approximately 1 1/2 ft. downwind from the exposed line. The concentration during the sample period of nearly 61/2 hours was well below the PEL TWAg and the action level. RECOMMENDATIONS: Request IH monitoring when personnel are in the area and/or the potential for disturbing the asbestos exists. METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Microscopy T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter. TLG/le y 5616A ^ T. L.Jgr><tie UCC 007238 t/jV- >> v0 DATE: INDUSTRIAL HYGIENE MONITORING June 20, 1987. PROJECT: DATE OF SAMPLES: SUMMARY: SAMPLE 2-8973 TYPE Area IH monitoring was requested as a result of concern over potential asbestos exposure in the Monomers control room. This concern was raised when it was found that loose insulation had dropped onto the roof of the building near the ventilation system intake. 2/13/87 TIME START STOP 11:02 18:52 MINUTES 470 FLOW RATE 3050 cc/min. VOLUME CONC. 1433.5 1 <0.003 fibers/ cc TWA8 0.133 f/cc RECOMMENDATIONS: Report these results to operators and staff in Monomers. DISCUSSION: METHOD OF ANALYSIS: DATA AND REPORT BY; ANALYSIS BY: COPY TO: Operators should be commended for bringing this situation to the attention of I.H. Fiber concentrations were well below the 12-hour time weighted average PEL. Continued recognition/ reporting/monitoring and correction of possible problem situations is strongly encouraged. Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter. TLG/le^/ 5609A UCC 007239 (/jU'0>~> :'7 ( INDUSTRIAL HYGIENE MONITORING DATE: PROJECT: DATE OF SAMPLES: June 30, 1987. Monitor area N.E. of tank farm number 3 in Silanes for asbestos. White fibers were seen floating in the air. These fibers were never identified. Area sampling was performed upon request. 3/24/87 SUMMARY: SAMPLE TYPE TIME START STOP MIN. FLOW RATE VOLUME CONC. TWA12 2-9109 Area 10:48 15:48 300 3050 cc/min 915 1 c0.005 f/cc 0.133 fibers/cc RECOMMENDATIONS: Communicate results to area personnel. DISCUSSION: ( Concentrations during the sampling period were well below the TWA^2 PEL for asbestos. This is based on the assumption that the material was asbestos even though it was never identified. Caution should be used when making such assumptions. METHOD OF ANALYSIS: Microscopy DATA AND REPORT BY: C. R. McMillan/T. L. Grittie ANALYSIS BY: JHM Labs COPY TO: D. G. Beddow, D. A. Boggs, A. A. Gosper, E. L. Doerflein, R. P. Leichliter. TLG/le 5608A )/ l UCC 007240 ( DATE: INDUSTRIAL HYGIENE RESULTS July I, 1987. PROJECT: Monitor Poly I control room for exposure potential to asbestos. Asbestos insulation is above the ceiling tiles and concern was expressed over the potential for a hazard to exist in the control room. DATE OF SAMPLES: 4/29/87 SUMMARY: SAMPLE TYPE LOCATION TIME START STOP MINUTES RESULTS PEL TWA12 Z-9221 Source Z-9222 Area Next to crawl space near missing ceiling tile above Bailey Operators desk 9:20 16:10 ** 410 98 <0.003 f/cc 0.01 f/cc 0.13 f/cc 0.13 f/cc *The pump shut off at some point during the sampling but ran for 98 minutes at the flow rate. ( ISCUSSION: Both samples were below the TWAj2 PEL as well as the action level. RECOMMENDATIONS: METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Conduct personnel monitoring for operator spending the most time in that area. Share the above results with personnel in that area. Notify IH if the ceiling tiles are to be removed. Microscopy T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, E. L. Doerflein, T. K. loannou, J. K. Kyle, L. P. Smith. TLG/le / l 617A * UCC 007241 toU'O-y ><? :p'7? ( DATE: PROJECT: INDUSTRIAL HYGIENE RESULTS July 1, 1987. Monitor insulators for asbestos exposure while using glove bags to strip T-lll in Tank Farm 4 in Silanes. DATE OF SAMPLES: SUMMARY: SAMPLE Z-9225 Z-9226 TYPE BZ BZ 4/30/87 TIME START STOP 12:54 13:34 12:57 13:34 MINUTES 40 37 RESULTS 0.14 f/cc <0.03 f/cc PEL TWA8 0.2 f/cc 0.2 f/cc DISCUSSION: , RECOMMENDATIONS: During the short sample time the fiber concentrations were below the PEL TWAg of 0.2 f/cc. Sample Z-9225 was slightly above the action level. Due to the short duration of sampling neither are truly indicative of an 8 hour exposure. The insulators wore breathing air. Glove bag method was' used. Share this information with insulators. Continue to request l.H. monitoring. METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, J. K. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Summers, G. W. Wulfert. TLG/le 5618A ^ UCC 007242 DATE: PROJECT: DATE OF SAMPLES: SUMMARY: SAMPLE Z-9050 Z-9051 Z-9052 TYPE BZ BZ BZ INDUSTRIAL HYGIENE RESULTS June 30, 1987. Monitor insulators for asbestos exposure while removing insulation from Emulsion Building, Polymers II. 2/15/87 and 2/17/87 DATE 2/15 2/15 2/17 TIME START 13:15 13:17 10:30 TIME STOP 14:20 14:20 11:30 MINUTES 65 63 60 RESULTS COMMENTS <0.02 f/cc 0.09 f/cc 0.68 f/cc Glove Bag Glove Bag Inside negative pressure enclosure BZ = breathing zone DISCUSSION: RECOMMENDATIONS: METHOD OF ANALYSIS: DATA AND REPOST BY: ANALYSIS BY: COPY TO: All insulators monitored wore airline respirators. As one can see from the above data, the use of glove bags where feasible, significantly reduces personnel exposure and should be the engineering control of choice if possible. Sample Z-9052 shows a fiber concentration above the PEL, TWAg of 0.2 f/cc during the sampling period. This concentration is, however, well below the limitations of the respirator. Use glove bags whereever feasible. Regardless of the method of choice, the material must be thoroughly wetted to minimize fibers in the air. Share this information with insulators. Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. A. Boggs, E. L. Doerflein, J. K. Kyle, D. L. Mullins, K. B. Purinton, W. V. Summers, G. W. Wulfert. TLG/le 5601A l/ UCC 007243 ATE: INDUSTRIAL HYGIENE MONITORING June 30, 1987. PROJECT: Monitor insulators for asbestos exposure while patching exposed insulation on T-3 methyl chloride tank in Monomers. DATE OF SAMPLES: 3/26/87 SAMPLE 2-9132 Z-9133 2-9134 TYPE B2 BZ B2 TIME START STOP MIN. 10:27 10:30 10:28 11:24 11:24 11:24 57 54 56 FLOW RATE (cc/min) 4000 4000 4000 VOLUME (liters) CONC. PEL TWA8 228 216 224 <.0.0022 f/cc 0.03 f/cc <0.02 f/cc 0.20 f/cc 0.20 f/cc 0.20 f/cc RESP. A A A RECOMMENDATIONS: Share this information with the insulators DISCUSSION: ( METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: All samples were well below the PEL during the sample period. Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, J. J. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Summers, G. W. Wulfert. TLG/le 5610A c UCC 007244 UNION CARBIDE CORPORATION Specialty Chemicals Sistersville Plant Uj'iJ'O i >o v' INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE PLANT _ . j was monitored for exposure to asbestos on 3/26/87. His exposure averaged <0.0022 fibers/cc during a sampling period of 57 minutes, 10:27 to 11:24, while patching exposed insulation on T-3 methyl chloride tank in Monomers. His exposure was less than the PEL of 0.2 f/cc, ^TWA 8 hours, for asbestos. wore disposable coveralls, gloves, and an *Rtrline respirator. r K TLG/1 e 5611A cc: Medical G. W. Wulfert Sample No. Z-9132 UCC 007245 UNION CARBIDE CORPORATION Specialty Chemicals ( Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE PLANT U)!)'C-yO . was monitored for exposure to asbestos on 4/24/87. His exposure averaged < 0.004 f/cc during a sampling period of 56 minutes, 9:54 to 10:50, while operating K-57. His exposure was less than the PEL of 0.133 f/cc, TWA 12 hours, for asbestos. wore disposable coveralls and a half facepiece HEPA filter dual cartridge respirator. TLG/le1 5620A cc: Medical IH D. L. Mullins Sample: Z-9207 UCC 007246 UNION CARBIDE CORPORATION____________________________________________ Specialty Chemicals Sistersville Plant ujJ' O 7- 'y'O # INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE PLANT ;was monitored for exposure to asbestos on 3/26/87. His exposure averaged 0.03 fibers/cc during a sampling period of 54 minutes, 10:30 to 11:24, while patching exposed insulation on T-3 methyl chloride tank in Monomers. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos. ^IfiDfline respirator. wore disposable coveralls, gloves and an TLG/lef'''" 5612A cc: Medical IH G. W. Wulfert Sample: 2-9133 UCC 007247 UNION CARBIDE CORPORATION_________________________________________ Specialty Chemicals Sistersville Plant uJ^O'yyO INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE PLANT f was monitored for exposure to asbestos on 3/26/87. His exposure averaged ^-0.02 fibers/cc during a sampling period of 56 minutes, 10:28 to 11:24, while patching exposed insulation on T-3 methyl chloride tank in Monomers. His exposure was less than the PEL of 0.20 f/cc, TWA 8 hours, for asbestos *&rl ine respirator. wore disposable coveralls, gloves, and an G. W. Wulfert Sample: Z-9I34 UCC 007248 UNION CARBIDE CORPORATION Specialty Chemicals U)U'0> >' Sistersville Plant => INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE was monitored for exposure to asbestos on 2/13/87. His exposure averagea '0.22 fibers/cc during a sampling period of 182 minutes, 9:50 to 12:52, while stripping asbestos insulation from piping associated with Polymers I tanks behind the 8" mill area. His exposure was 0.22 fibers/cc of air which is above the 8 hour time weighted average permissible exposure limit of 0.2 fibers/cc of air. The glove bag method of removal was utilized as well as wet methods within the bag wore . protective clothing and a half facepiece respirator with dual HEPA filter ^"^cartridges. TLG/le1^ 5595A ' cc: M. Patel S. Walker 380 IH Sample 2-8969 UCC 007249 UNION CARBIDE CORPORATION Specialty Chemicals iytf-Oi'&o #37 Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE - t was monitored for exposure to asbestos on 2/13/87. His exposure averaged 0.09 fibers/cc during a sampling period of 180 minutes, 9:52 to 12:52, while stripping asbestos insulation from piping associated with Poly I tanks behind the 8" mill area. His exposure was less than the PEL of 0.2 fibers/cc, TWA 8 hours, for asbestos. The glove bag method of removal was utilized as well as wet methods within the bag. wore protective clothing and a half face piece respirator with dual '5S*vHEPA filter cartridges. TLG/le^ 5597A 1 cc: M. Patel S. Walker 380 IH Sample Z-8970 UCC 007250 UNION CARBIDE CORPORATION Specialty Chemicals f Sistersviile Plant (/J \j^ 1 INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE PLANT ^ jwas monitored for exposure to asbestos on 4/23/87. His exposure averaged 0.10 fibers/cc during a sampling period of 300 minutes, 13:00 to 18:00, while cleaning up asbestos-containing debris in the Poly II kettlehouse in the K-57 area. His exposure was less than the PEL of 0.20 fibers/cc, TWA 8 hours, for asbestos wore disposable coveralls .^and an airline respirator. TLG/le^ 5621A cc: Medical IH G. W. Wulfert Sample: Z-9220 UCC 007251 UNION CARBIDE CORPORATION Specialty Chemicals Sistersville Plant #Sf INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE PLANT . i was monitored for exposure to asbestos on 4/30/87. His exposure averaged 0.14 fibers/cc during a sampling period of 40 minutes, 12:34 to 13:34, while stripping insulation from T-lll in Silanes Tank Farm 4. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for ^asbestos. wore disposable protective clothing and an airline respirator. A glove bag was being used. TLG/leU^ 5614A cc: Medical IH G. W. Wulfert Sample: 2-9225 UCC 007252 UNION CARBIDE CORPORATION____________________________________________ Specialty Chemicals Siatersville Plant U/V'- O'l'O INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE PLANT ms monitored for exposure to asbestos on 4/30/87* His exposure averaged <0.03 fibers/cc during a sampling period of 37 minutes, 12:37 to 13:34, while stripping insulation from T-1I1 in Silanes Tank Farm 4. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos wore disposable protective clothing and an airline ^respirator. a glove bag was being used. TLG/le^ 5615A cc: Medical IH G. W. Wulfert Sample: 2-9226 UCC 007253 UNION CARBIDE CORPORATION Specialty Chemicals 1/jJ-O'f >'0 &'?'/ Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE j was monitored for exposure to asbestos on 2/15/87. His exposure averaged ^0.02 fibers/cc during a sampling period of 65 minutes, 13:15 to 14:20, while removing insulation using a glove bag in the Emulsion Building. His exposure was less than the PEL of 0.2 fibers/cc, TWA 8 hours, for asbestos wore disposable protective clothing and an -.^irline respirator. TLG/le^ . 5604A cc: Medical IH G. W. Wulfert Sample Z-9050 UCC 007254 UNIOM CARBIDE CORPORATION Specialty Chemicals Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE was monitored for exposure to asbestos on 2/15/87. His exposure averaged 0.09 fibers/cc during a sampling period of 63 minutes, 13:17 to 14:20, while removing insulation in the Emulsion Building using a glove bag. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos *' wore disposable protective clothing and an airline '^es p ira tor. TLG/le 5603AL^ cc: Medical IH G. W. Wulfert Sample: Z-9051 UCC 007255 UNION CARBIDE CORPORATION Specialty Chemicals Sistersville Plant IjUiJ'O^ > o&j INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE was monitored for exposure to asbestos on 2/17/87. His exposure averaged 0.68 fibers/cc during a sampling period of 60 minutes, 10:30 to 11:30, while removing insulation within a negative pressure enclosure erected in the emulsion building. His exposure was greater than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos wore disposable protective clothing and an airline respirator. The fiber concentration during the ing period is well within the limitations of an airline respirator. TLG/1( 5602A cc: Medical IH G. W. Wulfert Sample: 2-9052 UCC 007256 UNION CARBIDE CORPORATION____________________________________________ Specialty Chemicals Sistersville Plant UJl/sOT'-yo# INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE PLANT was monitored for exposure to asbestos on 4/21/87. His exposure averaged <0.05 fibers/cc during a sampling period of 23 minutes, 11:07 to 11:30, while stripping asbestos using a glove bag on the 2nd level of the Rectification Tower in Silanes. Tffrs exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos, wore disposable coveralls and an airline respirator. TLG/le"'" 5606A cc: Medical IH G. W. Wulfert Sample: Z-9208 UCC 007257 l UNION CARBIDE CORPORATION Specialty Chemicals Sistersville Plant MEMORANDUM TO: FROM DATE SUBJECT COPY TO C. A. Gorrell K. B. Purinton G. W. Uulfert Mechanic Foremen Pipefitter Foremen T. L. Grittie May 5, 1987. Monitoring Asbestos Exposure During Gasket Removal D. A. Boggs E. L. Doerflein C. R. McMillan To comply with the new asbestos standard, it is necessary to monitor all employees who could potentially be exposed to asbestos. An exposure potential exists for those craftsmen who remove asbestos gaskets. From the small amount of historical I.H. data that we have, exposure should be inconsequential. Our data base is, however, not large enough to statistically support this premise. Therefore I must ask that you or your craftsman notify I.H. when asbestos gaskets are being removed. Please provide as much lead time as possible so that we will have monitoring equipment available and won't cause any delay in the work. Please call either myself (ext. 521) or Chuck McMillan (ext. 475). Thank you for your cooperation. TLG/le 5523A UCC 007258 UNION CARBIDE CORPORATION Specialty Chemicals LW'0>-jo Sis tersville T*lant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE > was moaitored for exposure to asbestos on 2/11/87. His exposure averaged C0.005 f/cc during a sampling period of 332 minutes, 9:15 to 15:37, while removing roofing (part transite) from the Polymers I Kettle House. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos. wore full body covering and a Corafo II respirator with HEPA filters. TLG/le 5474A ' cc: j. Boley IH Medical UCC 007259 UNION CARBIDE CORPORATION Specialty Chemicals uj, o Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE was monitored for exposure to asbestos on 2/11/87. His exposure averaged 0.05 fibers/cc during a sampling period of 333 minutes, 9:13 to 15:36, while removing roofing (part transite) from the Polymers I Kettlehouse. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos. wore full body covering and a Comfo II respirator with HEPA filters. TLG/le 54 73A cc: V- J. Boley IH Medical UCC 007260 ((JI/'-Oj 1 O ( DATE: PROJECT: DATE OF SAMPLES: INDUSTRIAL HYGIENE RESULTS April 7, 1987. Monitor contractors for exposure to asbestos while working on roof, part of which was transite. Polymers I,Kettlehouse roof. 2/11/87 SAMPLE TYPE TIME START TIME STOP RESPIRATOR? LOCATION RESULTS Z-8965 A 8:41 10:38 N/A Top of T-234 < O.OOl f/cc Z-8966 BZ 9:13 15:36 Comfo II HEPA filter Poly I Kettlehouse roof 0.05 f/cc Z-8967 BZ 9:15 15:37 Comfo II HEPA filter Poly Kettlehouse roof <0.005 f/cc ( Z-8968 A 8:32 15:39 N/A A Area BZ = Breathing Zone Kettlehouse roof ^0.003 f/cc l j- - DISCUSSION: All samples were below the OSHA PEL TWAg of 0.2 fibers/cc as well as below the action level of 0.1 fibers/cc. RECOMMENDATIONS: Share this information with both contractor and area personnel. Request I.H. monitoring when working with transite. METHOD OF ANALYSIS: Microscopy DATA AND REPORT BY: C. R. McMillan/T. L. Grittie ANALYSIS BY: JHM Labs COPY TO: D. G. Beddow, D. A. Boggs, J. E. Boley, E. L Doerflein, T. K. Ioannou, F. M. Plechaty, L. P. Smith, W. V. Summers, G. W. Wulfert TLG/le 5472A UCC 007261 i i UNION CARBIDE CORPORATION Specialty Chemicals Ujrf'O >> o $9^ Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE was monitored for exposure to asbestos on 2/4/87. Her exposure averaged 40.008 f/cc during a sampling period of 159 minutes, 13:33 to 16:12, while operating in the emulsion building. Her exposure was less than the PEL of 0.133 f/cc, TWA 12 hours, for asbestos. TLG/le 5466A cc: ' ' R. Leichliter IH Medical UCC 007262 UNION CARBIDE CORPORATION Specialty Chemicals Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE jwas monitored for exposure to asbestos on 1/29/87. His exposure averaged 0.021 /cc during a sampling period of 54 minutes, 14:36 to 15:30, while de-insulating R-6 in the Reactor Tower in Silanes. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos wore full body, disposable coveralls and an airline respirator. A negative pressure enclosure was built around the reactor during the de-insulation. TLG/le 5462A * cc: G. W. Wulfert IH Medical UCC 007263 UNION CARBIDE CORPORATION Specialty Chemicals UJi/-oy>o Sistersville ~&Iant ~ INDUSTRIAL HYGIENE PERSONNEL MONITORING REPORT UCC, SISTERSVILLE j was monitored for exposure to asbestos on 2/10/87. His exposure averaged 0.52 f/cc during a sampling period of 53 minutes, 10:32 to 11:21, while deinsulating R-2 in the Reactor Tower of Silanes. This concentration is above the OSHA PEL TWAg of 0.2 f/cc. Full body covering and airline respiratory protection were worn by ' TLG/le 5469A cc: G. V. Wulfert IH Medical rittie UCC 007264 UNION CARBIDE CORPORATION Specialty Chemicals Sistersville Plant INDUSTRIAL HYGIENE PERSONNEL MONITORING REPORT UCC, SISTERSVILLE o> ; ___, Was monitored for exposure to asbestos on 2/10/87. His exposure averaged 0.31 f/cc during a sampling period of 57 minutes, 10:30 to 11:23, while deinsulating R-2 in the Reactor Tower of Silanes. His exposure was higher than the OSHA PEL of 0.2 f/cc during the 57 minute monitoring period. It is not, however expected that this concentration would be maintained over the full 8-hour day. ~ ' wore full body covering and an airline respirator. TLG/le 5470A cc: " G. W. Wulfert Medical IH . Grittie UCC 007265 r i UNION CARBIDE CORPORATION Specialty Chemicals IHI'O y^o frs Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE > was monitored for exposure to asbestos on 1/20/87. His exposure averaged 0.074 fibers/cc during a sampling period of 65 minutes, 14:38 to 15:43, while removing transite from the roof of Polymers I Kettlehouse. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos. wore disposable coveralls and a Comfo II respirator with HEPA filters. TLG/le cc: J. Boley IH Medical 545 6A UCC 007266 UNION CARBIDE CORPORATION Specialty Chemicals (jjlJ-O><> Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE ; was monitored for exposure to asbestos on 1/16/87. His exposure averaged 0.035 fiber/cc during a sampling period of 64 minutes, 14:25 to 15:29, while removing asbestos gaskets. His exposure was less than the PEL of 0.20 f/cc, TWA 8 hours, for asbestos. TLG/le 5455A cc: 1 G. W. Wulfert IH Medical UCC 007267 UNION CARBIDE CORPORATION Specialty Chemicals UJlj'O > > oJf-JS Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE j was monitored for exposure to asbestos on 1/20/87. His exposure averaged 0.160 f/cc during a sampling period of 62 minutes, 14:40 to 15:42, while removing transite from the roof of the Polymers I kettlehouse. His exposure was less than the PEL of 0.20 PPM, TWA 8 hours, for asbestos. wore disposable coveralls and a Coofo II respirator with HEPA filters. TLG/le 545 7A cc: J. E. Boley IH Medical UCC 007268 UNION CARBIDE CORPORATION Specialty Chemicals "jjj. r -/ - O ^ JZ, Sis tersvilie Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE , was monitored for exposure to asbestos on 1/22/87. His exposure averaged <0.003 f/cc during a sampling period of 375 minutes, 8:45 to 15:00, while operating K-40. His exposure was less than the PEL of 0.133 f/cc, TWA 12 hours, for asbestos. TLG/le 5460A cc: J. E. Boley IH Medical UCC 007269 UNION carbide corporation Specialty Chemicals UJiJso > >o rr / Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE was monitored for exposure to asbestos on 1/29/87. His exposure averaged 0.109 f/cc during a sampling period of 67 minutes, 14:35 to 15:42, while deinsulating R-6 in the Reactor Tower in Silanes. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestof wore full body, disposable clothing and an airline respirator. A negative pressure enclosure was built around the reactor during the deinsulation. TLG/le 5463A cc: G. W. Wulfert IH Medical UCC 007270 UNION CARBIDE CORPORATION Specialty Chemicals Sistersville Plant ,*S8 INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE < was monitored for exposure to asbestos on 1/30/87. His exposure averaged 0.129 f/cc during a sampling period of 47 minutes, 12:53 to 13:40, while deinsulating R-6 in the Reactor Tower of Silanes. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos. jWore full body, disposable coveralls and an airline respirator. A negative pressure enclosure was built around the reactor during the deinsulation. TLG/le 5464A cc: _ . G. W. Wulfert IH Medical UCC 007271 UNION CARBIDE CORPORATION Specialty Chemicals Jjj' O^o ^ Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE : was monitored for exposure to asbestos on 1/30/87. His exposure averaged 0.026 f/cc during a sampling period of 43 minutes, 12:57 to 13:40, while deinsulating R-6 of the Reactor Tower of Silanes. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos. wore full body, disposable coveralls and an airline respirator. A negative pressure enclosure was built around the reactor during the deinsulation. TLG/le 5465A cc: G. W. Wulfert IH Medical UCC 007272 UNION CARBIDE CORPORATION Specialty Chemicals Sistersville Plant INDUSTRIAL HYGIENE PERSONNEL MONITORING REPORT UCC, SISTERSVILLE ; was monitored for exposure to asbestos on 1/20/87. His exposure averaged <0.032 f/cc during a sampling period of 34 minutes, 10:33 to 11:01, while removing asbestos from a heater in the fluids lab. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos. TLG/le 5453A ' cc: G. W. Wulfert IH Medical UCC 007273 UNION CARBIDE CORPORATION Specialty Chemicals (//(/'O'yio < 6 f Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE ; was monitored for exposure to asbestos on I/I6/87. His exposure averaged 0.158 f/cc during a sampling period of 56 minutes, 10:34 to 11:30, while removing asbestos from K-36 system using a glove bag. His exposure was less than the PEL of 0.2 f/cc, TWA 8 hours, for asbestos. If this exposure level were maintained over the entire 8-hour day the results would be above the action level. Airline respirators were worn by all of the insulators. TLG/le 5445A cc: Medical IH G. W. Wulfert UCC 007274 UNION CARBIDE CORPORATION Specialty Chemicals Sistersville Plant INDUSTRIAL HYGIENE PERSONAL MONITORING REPORT UCC, SISTERSVILLE yy & y was monitored for exposure to asbestos on 1/16/87. His exposure averaged 0.272 f/cc during a sampling period of 58 minutes, 14:31 to 15:29, while removing asbestos from K-36 system using a glove bag. If this exposure level were maintained over the entire 8-hour day the results would be above the OSHA PEL, TWA 8 hours. An airline respirator was worn during the entire 58 minute monitoring period. TLG/le 5448A cc: Medical IH G. W. Wulfert ii UCC 007275 ] J DATE: PROJECT: DATE OF SAMPLES: SAMPLE Z-8889 TYPE BZ jJJ'O INDUSTRIAL HYGIENE RESULTS April 6, 1987. Monitor K-40 operator for asbestos exposure due to ambient air movement. The operator performed the regular duties of the K-40 operator. 1/22/87 TIME START TIME STOP RESPIRATOR? RESULTS 8:45 15:00 No <0.003 f/cc BZ = Breathing Zone DISCUSSION: The results (<0.003 fibers/cc) are well below the OSHA permissible exposure limit of 0.133 fibers/cc TWA]^ and also well below the action level of 0.667 fibers/cc (for 12 hours). This indicates that during a normal day the K--40 operator was not overexposed to asbestos. RECOMMENDATIONS: Request I.H. monitoring of other operators who may be concerned about asbestos exposure. This will assist in pinpointing any "trouble spots". Share this information with operators. METHOD OF ANALYSIS: Microscopy DATA AND REPORT BY: C. R. McMillan/T. L. Grittie ANALYSIS BY: Kemron Environmental COPY TO: D. A. Boggs, E. L. Doerfiein, D. L. Mullins, F. M. Plechaty, R. D. Smith, W. V. Summers TLG/le 5459A UCC 007276 J --}- O Ff INDUSTRIAL HYGIENE RESULTS DATE: April 6, 1987. PROJECT: Monitor Emulsion Building area as well as an operator to determine the exposure potential due to exposed asbestos in the area. DATE OF SAMPLES: 2/4/87 SAMPLE TYPE TIME START TIME STOP RESPIRATOR RESULTS Z-8956 Z-8957 Area BZ 13:30 13:33 16:15 16:12 N/A No <0.007 fibers/cc <0.008 fibers/cc BZ = breathing zone DISCUSSION: RECOMMENDATIONS: The area sample was placed approximately 3 inches from exposed asbestos on a vibrating pipe. Both the personnel and the area samples show levels well below both the action level (0.0667 fibers/cc - 12 hour average) and the OSHA Permissible Exposure Limit (TWA^2 of 0.133 f/cc). Where it is suspected that an exposure potential may exist, I.H. monitoring should be requested. Share these results with area operators. METHOD OF ANALYSIS: Microscopy DATA AND REPORT BY: T. L. Grittie ANALYSIS BY: JHM Labs COPY TO: D. A. Boggs, E. L. Doerflein, D. L. Mullins, F. M. Plechaty, R. D. Smith, W. V. Summers. TLG/le 5467A UCC 007277 INDUSTRIAL HYGIENE RESULTS DATE: April 7, 1987. PROJECT: Monitor insulators for asbestos during deinsulation of R-2 in the Reactor Area of Silanes. A negative pressure enclosure was built around the reactor for the purpose of deinsulation. DATE OF SAMPLES: 2/10/87 SAMPLE TYPE TIME START TIME STOP RESPIRATOR RESULTS Z-8962 Z-8963 BZ BZ 10:30 10:32 11:23 11:21 Airline Airline 0.31 fibers/cc 0.52 fibers/cc BZ = Breathing Zone DISCUSSION: RECOMMENDATIONS: METHOD OF ANLYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Both samples showed air concentrations above the OSHA PEL during the monitoring period. Respiratory protection was worn during the entire monitoring period. Even if one considers 4 - one hour exposure periods with no other exposures and averages this over 8 hours, sample Z-8963 would be above the PEL TWAg of 0.2 fibers/cc. Obviously, these concentrations are unacceptable. Wet methods must be used more effectively. The use of the enclosure keeps all ambient fibers in close proximity to the worker and therefore the methods used to prevent fiber release must be even more stringent. It goes without saying that respirators must continue to be used when working in the temporary enclosure. This will not be counted as an overexposure since respiratory protection prevented the employee from actually being exposed to the material. Microscopy T. L. Grittie J.H.M. Labs D. A. Boggs, E. L. Doerflein, J. K. Kyle, F. M. Plechaty, K. B. Purinton, W. V. Summers, G. W. Wulfert. TLG/le 5468A UCC 007278