Document K6xRY4pq3qm0Xnze2Meg6B3DX

V' TCrv:V>xV?.(- '.V. . A 'A *1*^ .*] -/-VvV-'' v >v '^ os>; c.* :racial Insulation. v;:-":''Material and Application. v\A'\,< . - ' V'iK- A/' '' v.' .. " .V:/V`y-. s:A*-l v'. V ' \ ' v* July 1961 * ` t ,. * '/ ... `v wV v SOUTH CHARLESTON WEST VIRGINIA .Vi'. .v' * \ . DESIGN AND CONSTRUCTION UNION CARBIDE CHEMICALS COMPANY Division of UNION CARBIDE CORPORATION SPECIFICATIONS For Thermal Insulation Material and Application January 1958 L I Ij 1 L SOUTH CHARLESTON WEST VIRGINIA UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS FOREWORD A. General These Specifications describe the essential requirements for the purchase and application of thermal insulation materials * They consist of two major parts: I - General Specifications, and II Individual Specifications. Each Specification is divided into two parts: (A) Materials, and (B) Application. Individual Specifi cations are identified by a two-digit number, followed by a letter. The applicable Individual Specification and the thickness of insu lation to be used shall be indicated in an Insulation Design Sched ule. The General Specification constitutes an integral part of all the Individual Specifications. B. Definitions Where the following terms are found within the General and the Individual Specifications, they shall have meaning and signifi cance as defined: 1. Blanket............Insulating material consisting of organic or in organic fibers, suitably felted, woven, stitched, bonded, or reinforced, into flexible form. 2. By Others...........Purchase or installation, or both, of subject material will be made by other than Insulation Contractor or insulation mechanics. 3. Curved Segment .... Block insulation of uniform thickness , formed to fitcontour of curved surfaces and with longitudinal edges radially beveled. 4. Finish........... Material applied to surface of ins ulation for pro tection and/or appearance. FOREWORD -- contd B. Definitions -- contd 5. Firmly. ... .A section of pipe insulation, when secured in the specified manner to a vertical pipe of corresponding dimen sion, shall remain at that elevation unsupported except by friction. 6. Fitting Cover............Block and pipe insulation patterned to fit on flanges, valves, and other fittings, furnished in conven ient and matching sections. 7. Lagging............Relatively narrow, flat block insulation, rec tangular in shape, of uniform thickness, and with longitudinal edges radially beveled. 8. Loose Fill...........Thermal insulating material in loose fibrous or powdery form, for application within enclosed spaces. 9. Molded-Type Pipe Insulation............A rigid or semi-rigid thermal insulating material, preformed in semi-cylindrical or segmental sections, or both, usually 3 ft. in length; for application on pipe or tubing, furnished with or without finish or attachments...........(ASTM Standard C-168.) 10. Preformed Thermal Insulating Block............A rigid or semi rigid thermal insulating material, either flat or segmental, for application as received, and excluding brick of the 9-in. series...........(ASTM Standard C-168.) 11. Sectional Pipe Insulation............Two semi-cylinders of pipe insulation combinedto form a complete circumference. 1Z. Segmental Pipe Insulation............Curved segments of pipe in sulation of less than one-half circumference which, when grouped and combined with an odd width, where necessary, form a complete circumference. 13. Shaped Head Segment............Block insulation patterned to fit on shperical, flanged and dished, or other type, vessel heads, usually with but a single radius - furnished in convenient and matching sections. 14. Staggered a. Pipe insulation shall be in a staggered position when, upon application, the end joint between two abutting half - -2 - FOREWORD B. Definitions -- contd 14. Staggered -- contd sections occurs at least one-third, but preferably one-half the length of a section, from either end of the opposing half section. b. Block (curved segments, lagging) insulation shall be in a staggered position when the abutting joint between two blocks occurs, upon application, at least one-thirdthe length of a section from joints of adjacent blocks. c. Multi-layer insulation shall be considered broken joint when applied so that no two joints coincide except where they cross at right angles. 15. Thermal Insulating Cement............A prepared composition, in dry form, comprising granular, flaky, fibrous, or powdery materials, which, when mixed with a suitable proportion of water to develop aplastic consistency, and applied and dried '-in place, forms a coherent covering that affords substantial resistance to heat transmission............(ASTM Standard C-168.) 16. ` Weather-Barrier (Weatherproofing)............Finish applied for moisture and weather protection. -3 - UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS I. GENERAL SPECIFICATIONS Scope This specification describes the essential requirements for the purchase and application of thermal insulation materials. It also constitutes an integral part of the Individual Specifications. A. MATERIAL 1. Types and Dimensions a. Material furnished under these Specifications shall be of type and thickness listed on Insulation Design Schedules, Insulation Equipment and/or Line Lists, or as otherwise prescribed by the Department of Design and Construction. b. Pipe insulation shall be furnished in convenient lengths, plus or minus not more than 3/32-inch, with ends cut square. Inside diameter shall fit firmly on specified pipe size and outside diameter shall correspond to an Iron Pipe Size. 2. Sampling and Testing Where vendor is unable to provide acceptable test, or performance data, to meet the requirements of these Specifications, representative samples of insulating and accessory materials shall be submitted to the De partment of Design and Construction in sizes and amounts required for testing. In all instances these samples , which shall be supplied without cost to purchaser, shall be shippedby vendor within seven days following receipt of written request. 3. Packaging Unless otherwise agreed, material shall be packed in substantial containers, so constructed as to insure safe -1 I. GENERAL SPECIFICATIONS A. MATERIAL - contd 3. Packaging -- contd delivery of material, in a condition satisfactory to the purchaser,by common and other approved carrier. 4. Marking and Identification Unless otherwise specified, shipping containers shall be legibly marked with name of material, size, type, and quantity contained therein; name of Insulation Contractor, if any, and purchase order number under which shipment is made. In addition, where required, container shall bear the work order number, the Item No. (if any) for which material is intended and its relative position and sequence of application. 5. Attachments a. Standard lacquered or brass bands, customarily furnished by the manufacturer of pipe insulation, will not be required. b. Canvas or other factory-applied surfacing, where required with insulating material, shall be as called for on bills of material or other purchase requisi tions. 6. Approved Alternates Alternate insulating and/or acc es sory materials may be approved by the Department of Design and Construction, but only where clearly shown that properties involved satisfy all requirements which this Specification pre scribes. 7. Rejections a. Insulation and/or accessory material will be re jected by purchaser, before or after delivery, where physical and other properties do not meet the re quirements specified and no exemption has been granted by the Department of Design and Construc tion. 2- - I. GENERAL SPECIFICATIONS A. MATERIAL - contd 7. Rejections -- contd b. All costs in connection with rejected material shall be borne by the vendor. B. APPLICATION 1. Thickness Schedule Unless otherwise specified, insulation in excess of 2-1/2 inches total thickness shall be applied in multi layer construction in accordance with the following table: Total Scheduled Thickness" Inner Layer Thickness" Middle Layer Thickness" Outer Layer Thickness 3 3-1/2 4 4-1 /2 5 5-1/2 6 6-1/2 7 7-1/2 8 8-1/2 9 1-1/2 1-1/2 2 2 2-1/2 1-1/2 2 2 2 2-1/2 2-1/2 2-1/2 3 None None None None None 2 2 2 2-1/2 2-1/2 2-1/2 3 3 1-1/2 2 2 2-1/2 2-1/2 2 2 2-1/2 2-1/2 2-1/2 3 3 3 2. Condition of Material Insulation materials, other than cements and mastics, may be applied only when dry. 3. Condition of Surfaces a. Insulating material shall be applied to clean, dry surfaces only. 3- - I. GENERAL SPECIFICATIONS B. APPLICATION -- contd 3. Condition of Surfaces -- contd b. Where insulation is appliedto piping and equipment operating in the temperature range of 0F to 180F, the metal surfaces of said piping and equipment shall be coated, in accordance with UCCC Coat ing Specifications, by others, prior to application of insulation. c. Voids behind name plates and tank legs shall be filled and caulked, in accordance with UCCC Coat ing Specifications, by others, prior to application of insulation. 4. Insulation Supports a. Insulation on vertical equipment, exceeding l'-5" in diameter and 101 -0" in height, shall be supported by metal supports installed approximately every 12'-0" andabove each vessel flange, inaccordance with UCCC Standard IS-31. Length of horizontal leg or support angle shall be 1 /2 inch less than total applied thickness of insulation. b. Insulation on horizontal equipment, 4'-0" diameter and larger, shall be supported by metal supports installed in accordance with UCCC Standard IS-36. c. Insulation applied to bottom head, or inside of skirt, on skirt supported vessels, shall be supported on metal supports installed in accordance with UCCC Standard IS-42. d. Insulation on dished heads of vertical equipment shall be supported by metal supports in accordance with UCCC Standard IS-31. e. Where necessary to prevent entrance of moisture, uppermost support shall be replaced with a metal protective plate, as described in section I. B. 12 , entitled "Protective Cover". -4- I. GENERAL SPECIFICATIONS B. APPLICATION - contd 5. Securement a. Tie-Wire Anchors Blank nuts, angle clips, and other approved attach ments shall be used for insulation tie wire anchors, where shape of vessel prevents normal methods of securement of preformed insulating materials. Blank nuts, where required, shall be attached, standingedge to vessel surface, by light fillet weld, or par tially filled interface. Installation shall be done by the Insulation Contractor, prior to application of in sulation. b. Wire (1) Wire shall be applied to insulation at proper intervals by looping about the circumference, twisting ends tightly together to provide proper securement, and depressing wire ends against insulation to prevent projections. (2) Where shape of vessel prevents complete en circlement, securement shall be made to other tie-wires, wire cables, or other anchors for this purpose. c. Insulation Strap (1) All pipe insulation on steam traced lines shall be secured v'ith stainless stee] insulation strap. (2) Scrap shall be applied to cylindrical insulation at proper intervals by looping strap about the circumference, stretching to suitable tightness I. GENERAL. SPECIFICATIONS B. APPLICATION -- contd 5. Securement -- contd c. Insulation Strap -- contd with an approved banding machine, and clamp ing in place at joint. Strap joint shall consist of one double-prong clip, or two clips fur nished without prongs. Clips shall be located on the vertical side of pipe insulation. (3) Where shape of vessel prevents complete en circlement of strap, securement shallbe made to tie wires, wire cables, or other devices approved for this purpose. (4) Insulation strap shall be divided into lengths based on one strap joint for the first 15 feet of vessel circumference and one strap joint for each additional 10 feet, or part thereof. These j oints shall be spaced at equal distances about the vessel. d. Spacing of Strap and Wire (1) Spacing of insulation strap and wire over equip ment and pipe insulation shall be based on length of block or section. Where 36-inch length insulation is applied in staggered ar rangement, four loops will be required at average nine-inch intervals, so that no loop is located more than 4-1/2 inches from any end joint. Where 18-inch lengths are applied in staggered arrangement, only two loops per length shall be required. -6 - I. GENERAL SPECIFICATIONS B. APPLICATION - contd 5. Securement - contd d. Spacing of Strap and Wire - contd (2) Spacing of strap and wire on pipe insulation shall correspond to Figures GA-1, and GA-2. -7- I. GENERAL SPECIFICATIONS B. APPLICATION -- contd 5. Securement - contd 8- - i. i l I. GENERAL SPECIFICATIONS B. APPLICATION - contd i 6. Name Plate Clips T Insulation mechanics shall cooperate with others in the placement of name plates and name plate clips. 1 7. Junction of Thermal Insulation with Fire Resistant Materials a. Insulation thickness on tank legs, and similar equip ment supports, shall be not less than adjoining fire resistant materials. Where thickness of thermal insulation exceeds that of fire resistant materials, \ surface of insulation shall be neatly and uniformly finished with a wide bevel, - feathered to provide appearance of continuous surface and eliminate a { definite surface joint. b. Junction of insulation with fire-resistant materials L shall be sealed with weather-barrier coating. 8. Nozzle Flashing All nozzles on top of insulated equipment shall be pro vided with flashing as shown in Figure GA-3. t. NOTE' COMPLETE WEATHER-8ARRIER OVER INSULATION BEFORE INSTALLATION OF FLASHING 1 I I. FLASHING ON TOP NOZZLES OF EQUIPMENT L FIG. GA S L -9 - I. general specifications B. APPLICATION - contd 9. Protection of Flammable Surfacings When applying sheeting jacket, flammable surfacings shall be stopped at least six inches from brackets, hangers, and other hot projections, to avoid possi bility of scorching or ignition. Where located indoors, such areas shall be surfaced with insulating cement to provide drainage. For other locations, a minimum l/l6 inch thick coat of heat-resistant sealer shall be applied. 10. Painting Painting of bare and insulated surfaces, where required, will be done by others. 11. Protection from Abuse a. Insulation subject to mechanical abuse, such as abrasion or crushing, or where otherwise required, as designated by the Department of Design and Con struction, shall be protected with a covering jacket of not thinner than No. 26 gage sheet metal, or other approved media, as per UCCC Standard M-100. Jacket shall be secured firmly in place with insulation strap, spaced not greater than 10 inches on centers, or sheet metal.screws where use of strap is impracticable. Sheet metal screws shall not be used on jackets over low temperature insula tion where possibility exists of piercing weather vapor barrier membrane. This protection will be provided by the Owner. b. Corners of insulated ducts, breechings, and other flat-surfaced equipment shall be reinforced by in stallation of expanded metal lath corner bead, or corner inserts when approved. Bead and insert shall be provided by the Insulation Contractor and installed by insulation mechanics, following appli cation of insulation block, securing it firmly to block tie wires. Cement shall be forced through lath flange to provide proper key. 10 I. GENERAL SPECIFICATIONS B. APPLICATION - contd 12. Protective Cover Insulation terminating at an intermediate point on the side of a vessel shallbe protectedfromphysical abuse and moisture penetration, by installation of a continuour metal plate attached to vessel by means of a con tinuous weld immediately above insulation. This pro tection will be provided by the Owner. 13. Appearance Lapped joints, selvage ends, and other irregularities of surfacing materials shallbe concealedfrom general view wherever possible. 14. Insulation for Safety a. Where it is required to insulate piping or equip ment for safety, only that portion shall be insula ted which is located not more than 6' -0" above operating levels, or where there exists possibility of human contact. Piping in trenches, unless otherwise specified, shall not be insulated for safety below grating level. Exposed ends of insu lation shall be beveled with insulating cement to provide proper seal and drainage. b. Where specified, thermal insulation shall be omit ted and protection provided by erection of a suit able safety guard. This guard will be provided by the Owner. 15. Steam Traced Installations a. Accessories - Pressed steel spacers shall be of No. 16 Gage (.0598"), constructed according to UCCC Standard P-84A, as manufactured by A. J. Gerrard. These spacers shall be furnished by the Insulation Contractor. 11 I. GENERAL SPECIFICATIONS B. APPLICATION - contd 15. Steam Traced Installations - contd b. Assembly - Type and size of tracer lines; methods of clamping, hanging and supporting them; and size of pipe insulation to be applied, shall be in accord ance with UCCC Standards P-84, P-84A and GA-4, supplemented by Insulation Design Schedules, where required. In addition to assembly directions con tained in Standards P-84 and P-84A, pressed steel spacers (and pressed steel clamps, where installed) shall be spaced on 18-inch centers for copper tracer lines. Temporary installation of assembly will be done by others. APPLICATION OF INSULATION TO STEAM TRACED LINES FTO GA-4 c. Pipe insulation shall be applied in required sizes and carefully fitted to heated companion lines in manner prescribed in these Specifications and in the Individual Specifications. Tracer assembly shall b e firmly and permanently secured 12- - GENERAL SPECIFICATIONS B. APPLICATION - contd 15. Steam Traced Installations -- contd in place by insulation mechanic during application of insulation, adding or relocating spacers where required to insure firmness of contact. d. Protective Lining - When aluminum piping is to be steam traced, or where elsewhere required, aluminum piping shall be separated from tracer assembly by insertion of not less than two wrap pings of glass fiber tape. Care shall be exercised that tracer line does not contact aluminum line at any point. Where tracer may touch, the aluminum line shall be wrapped with glass tape at that point. 16. Weather-Barrier Coatings a. Insulation shall be coated with a weather-barrier at time of installation. b. Coatings shall not be applied when atmospheric temperature is below 32F. Where circumstances prevent immediate application of coating, insula tion shallbe temporarily protected from inclement weather. c. Where sprayed weather-barrier is to be applied, adjacent areas not to be coated, such as valve stems, handles, gauge glasses, instruments and other adjacent equipment or structures, shall be masked or otherwise protected. d. A heavy fillet of caulking mastic shall be applied at all inside corners of insulation and at all junc tions of insulation and metal, prior to application of weather-barrier coating. e. Weather-barrier membrane shall be carried out six inches onto metal, beyond termination of in sulation at supports, skirts or other projections , and sealed to the metal. f. All weather-barrier coatings shall be firmly bonded to insulation surface and reinforced with glass fiber -13- I. GENERAL SPECIFICATIONS B. APPLICATION - contd 16. Weather-Barrier Coatings -- contd cloth. Joints of reinforcing cloth shall be uniform in thickness and have a smooth unbroken surface, free of pinholes. Care shall be taken that openings inweave of cloth are completely sealed and hidden with specified coating. g. (1) Where asphaltic weather-barrier coatings are used on large vessels and lines, they shall be applied by spraying, using the hot spray method. Where conditions make spraying practicable, such as small lines, application shall be by brushing, troweling, or palming. (2) The combined thickness of the weather-barrier coating and reinforcing cloth shall be not less than l/8 inch, when dry. h. (1) Where flame-resistant, modified polyvinyl acetate emulsion weather-barrier is specified, it shall be appliedby either cold spray, palm ing, troweling, or brushing. (2) The combinedthickness of the weather-barrier coating and reinforcing cloth shall be not less than 1/16 inch when dry. -14- I. GENERAL SPECIFICATIONS B. APPLICATION - contd 16. Weather-Barrier Coatings -- contd (3) All outside corners of insulation shall be roundedandthe weather-barrier coating pro vided with a double layer of reinforcing cloth as shown in Figure GA5. APPLICATION OF WEATHER-BARRIER COATING AT CORNERS FIG GA-5 - 15 of 15 - ||S Xo 52 0u ^ < < i- 1/5- 2 x * cr ~ Ul 22* ft o *" s^g ?e Sgi^i =! T x to 1 V) X > \ r--1 1 H, ", 1 i \ -k \ .* \ \ l 7----- W------------ :-------- , :: Ux* 2* y**_ / -0-#0 Cm-ZDIiI ^fio.lQ IS-311 IS-42 *16" DIA DRILL FOR *4 DIA X 'z LONG CADMIUM PLATED MACHINE SCREW AND SQUARE NUT RADIUS '2 OD OF PROCESS LINE (ADD 'le" FOR ASBESTOS PAPER ON ALUMINUM LINES) N9 16 MFR STD GAGE (.0598") RADIUS = '2 OD OF TRACER LINE PRESSED STEEL CLAMP FOR PROCESS LINES 7/Q" OD AND SMALLER PRESSED STEEL SPACER NOTE-. SHALL BE ASTM A7 CARBON STEEL. REVISED: 8-3*5533 THIS STANDARD IS MANDATORY ONLY WHEN INCORPORATED WHOLLY OR WITH EXCEPTIONS. INTO DESIGN REPORTS DESIGN DRAWINGS OR OTHER DESIGN DATA, OR INTO BILLS-OF-MATERIAL OR PURCHASE ORDERS. Carbide and carbon Chemicals Company A DIVISION or UNION CARBIDE AND CARBON CORPORATION SOUTH CHARLESTON. WEST VIRGINIA STA N DA R D N2 CLAMPS AND SPACERS FOR P-84A STEAM TRACED LINES CLASSIFICATION: DETAIL SPONSOR: H2B BY: DATE: g/7/53 APPROVED: DATE: 4-Z7-47 UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL, INSULATION SPECIFICATIONS II. SPECIFICATION 10-B Cellular Glass Scope This specification describes the essential requirements for the purchase and application of preformed cellular glass insulation, for use in building roofs, side walls and floors. Procedures outlined in the GENERAL SPECIFICATIONS are applicable to and constitute an integral part of this specification. A. MATERIAL 1. Composition Material shallbe composed of glass, complete inorganic, processed and molded at temperatures sufficient to pro duce a rigid, cellular thermal insulation. 2. Properties Cellular glass insulation shall have the following prop erties: Acid Resistance . . . . Impervious to common acids and acid fumes. Alkalinity.........................................pH = 7.5 Capillarity........................................0 Coefficient of Expansion . . 0.0000040 per F Combustibility.................................Incombustible Composition...................................... A true glass: completely inorganic. Compressive Strength . . . 100 lbs. per sq. in. H. SPECIFICATION 10-0 A. MATERIAL - contd 2. Properties - contd Density.................................. . , 9 to 11 lbs, per cvu ft. Flexural Strength . . . 100 lbs. per sq. in. Hygroscopicity. . . . . No increase in weight in 246 days in air at 90% relative humidity. Modulus of Elasticity . . . 200,000lbs. per sq. in. Shear Strength . . .64 lbs. per sq.. in. Specific Gravity . . 0.16 Specific Heat . . . Tensile Strength . . . . 0.20 BTU per lb. .84 lbs. per sq. in. Thermal Conductivity . . . Shall not exceed values at the following mean tempe ratures: Mean Conductivity Temp. *F Btu/hr. , sq.ft 50 300 *F,inch thick 0.40 0.55 Thermal Diffusivity . . . .0.40 sq. ft. per day Water Absorption* . . .0.2% by volume on 2" x 12" x 18" block (all on surface only.) Temperature Limits . . . Minus 350Fto plus 600F - 2- II. SPECIFICATION 10-B A. MATERIAL - contd S, Accessory Materials a. Cellular glass insulation b. Asphalt - 180* Hot Asphalt c. Asphaltic Cement - Pittsburgh-Corning Asphaltic cement, or approved alternate. d. Felt - 15 lb. asphalt saturated. - 3- H. SPECIFICATION 10-B B. APPLICATION 1. Roof Decks (General) a. Unless otherwise specified, insulation in access of 2-1/2 inches total thickness shall be applied in multiple lay e r s as specified in GENERAL SPECIFICATIONS, Partl.B.l. b. Roof Decks shall be plane, dry, clean and free from hole8 through which bitumens might drip. All materials used shall be dry before and during application. c. Insulation shall be adhered to the prepared surface, by firmly embedding in molten hot asphalt. Mop only edges of block and area on which insulation can be immediately laid. d. Each layer of insulation shall be applied with all joints tightly butted and sealed with hot asphalt. Insulation shall be applied in parallel courses and all joints between blocks staggered. Asphalt shall be heated not more than 360*F. e. After insulation is installed as specified, entire surface shall be flood mopped 'with l/l6" inch thick (minimum) coat of hot asphalt and allowed to set. Any cracks or voids present after first mopping shall receive.- second mopping to insure complete s.eal prior to application of built-up-roof. 2. Flat Roofs Figures 10-B-l, 10-B-2, and 10-B-3 show typical in sulation details of roofs having slopes that do not ex ceed two inches per foot. -4- II. SPECIFICATION 10-B B. APPLICATION 2. Flat Roofs SLAG OH GRAVEL BUILT UR ROOR rrrjy/yrnyyy? f y r * j- J j- * * x k -ur * CONCRETE -i.frirf? * V.'V.V- 'V*. . * > **m \ -SPECIFIED THICKNESS OF CELLULAR GLASS EMSEOOED IN HOT ASPHALT CONCRETE ROOF DECK FIGURE IO-BH -SLAG OR GRAVEL SPECIFIED THICKNESS OF CELLULAR GLASS -BUILT UP ROOF EUBEOOEO IN HOT / -asphalt Z.'Arjry/T'r r7 v /7'7rrv frr " fjf'frfsfi vhL- "WOOD DECK NAILING STRIP WOOD ROOF DECK FIGURE (0-6-2 -5- II. SPECIFICATION I0-B B. APPLICATION 2. FlatRoofs -6- II SPECIFICATION 10-B B. APPLICATION 3. Pitched Roof3 Where insulation is specifiedfor roofs, having a slope in excess of two inches per foot, they shall be insulated as shown in Figure 10-B-4. -7- II. SPECIFICATION 10-B B. APPLICATION - contd 4. Walls and Ceilings a. Where cellular glass is specified for smooth surfaced interior walls or ceilings, it shall be applied in the following manner. (1) Surfaces requiring insulation shall be dry, clean, smooth, and primed with a brush coat of hot asphalt. (2) Cellular glass shall be applied using hot asphalt as an adhesive. Back of block and two adjacent edges shall be dipped in hot asphalt and applied to the primed surfaces while asphalt is still mol ten. Asphalt shall be heated not more than 360 *F. (3) Block shall be applied with all joints tightly butted, and fully sealed with asphalt. Thickness of asphalt joint shall not exceed l/l6 inch. Insulation shall be applied in parallel courses with all joints be tween blocks staggered. b. Where cellular glass is specified for interior walls and ceilings, and surfaces are irregular, it shall be applied in the following manner. (1) Surface requiring insulation shall be dry and clean. (2) Cellular glass shall be applied with asphaltic ce ment gobs. Cement shall be applied near the four corners of the back face of the block, and a trowel coat of the same cement on two adjacent edges. Apply block with sufficient manual pressure to assure tight joints and good contact with the ma sonry wall. Thickness of asphalt joints shall not excee d l/l6 inch. (3) All finish surfaces of insulation shall be true, plumb and flush. - 8- II. SPECIFICATION 10-B B. APPLICATION - contd 5. Concrete Floor Slabs a. Foundation Wall Method (1) Where specified, insulation shall be applied to foundation walls as shown in Figure 10-B-5. (2) Insulation surfaces adjacent to foundation wall and floor slab shall be separated from the con crete with a layer of roofers felt cemented to the insulation block with hot asphalt. (3) Blocks shall be installed with adjacent edges and back surfaces dipped in hot asphalt and applied while asphalt is still molten. All joints shall be tightly butted. - 9- II. SPECIFICATION 10-B B. APPLICATION - contd 5. Concrete Floor Slabs - contd b. Slab-Border Method (1) Where specified, insulation shall be applied to foundation walls as shown in Figure 10-B-6. (2) Insulation surfaces around the perimeter shall be separated from the slab edge and foundation with a layer of roofers felt cemented to the insulation block with hot asphalt. (3) A layer of sand, approximately one inch in thick ness, shall be applied over gravel before apply ing insulation. (4) Blocks shall be installed with all joints tightly butted. - 10 - n. SPECIFICATION I0-B B. -APPLICATION - contd 5. Concrete Floor Slabs - contd b. Slab-Border Method (5) After insulation is installed as specified, entire surface shall be flood mopped with a l/l6 inch thick (minimum) coat of hot asphalt prior to pour ing of floor slab. Asphalt shall be heated to a temperature not exceeding 360*F. - 11 - UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 10-H Cellular-Glass Scope This specification describes the essential requirements for the purchase and application of preformed cellular-glass insulation, for use on equipment and piping normally operating at tempera tures above 70F. and up to 600F. It is applicable to both indoor and outdoor service. Procedures outlined in the GENERAL SPECIFICATIONS are applicable to and constitute an integral part of this specification. A. MATERIAL 1. Composition Material shallbe composedof glass, completely inorganic, processed and molded at temperatures sufficient to pro duce a rigid, cellular thermal insulation. 2. Properties Cellular glass insulation shall have the following prop erties: Acid Resistance..............................Impervious to common acids and acid fumes. Alkalinity............................................. pH = 7. 5 Capillarity............................................. 0 Coefficient of Expansion 0.0000040 per F Combustibility..................................... Incombustible Composition ...... A true glass; completely inorganic. II. SPECIFICATION 10-H A. MATERIAL - contd 2. Properties - contd Compressive Strength. . . . 100 lbs. per sq. in. Density............................................ . 9 to 11 lbs. per cu. ft. Flexural Strength .... . 100 lbs. per sq. in. Hygroscopicity.............................. . No increase in weight in 246 days in air at 90% relative humidity. Modulus of Elasticity . . 200, 000 lbs. per sq. in. Shear Strength.............................. . 64 lbs. per sq. in. Specific Gravity.............................. . 0. 16 Specific Heat..................................... Tensile Strength .... . 84 lbs. per sq. in. Thermal Conductivity . . Shall not exceed values at the following mean temperatures: Mean Conductivity Temp. F Btu/hr.,sq. ft., F,inch thick 50 0.40 300 0.55 Thermal Diffusivity . 0.40 sq. ft. per day Water Absorption .... . 0. 2% by volume on 2" x 12" x 18" block (all on surface only. Temperature Limits . Minus 350F to plus 600F. 3. Accessory Materials a. Cellular glass insulation II. SPECIFICATION 10-H A. MATERIAL - contd 3. Accessory Materials - contd b. Cushioning material Equipment - l-l/2 1b. density, Aerowrap P-308, Fine Fyber Felt. Piping - Piping 350F and under, Ultrafine, Super fine, Mono-Kover. Piping above 350F, Aerowrap P-308. c. Stainless Steel Wire - .0475 inch dia., type 304, cold drawn, bright annealed, 18 gage. d. Stainless Steel Insulation Strap - l/2inchx .020 inch, type 304 or approved alternate. e. Stainless Steel Die Cut Strap - 3/4inchx.023 inch, 2-inch fingers on 9-inch centers, A. J. Gerrard or approved alternate. f. Stainless Steel Clips - Double pronged, type 304, A. J. Gerrard or approved alternate. g. Strap Anchor Clip - A. J. Gerrard's strap hanger. h. Anti-Abrasion Coating - Keen Cement or approved alternate. i. Weather-Barrier Coating - (color as specified)-Vimasco WC-1, Benjamin Foster SeaJxas "C", or approved alternate. j. Reinforcing Cloth - Glass fiber, 10 x 10 thread count, Perma Glas Mesh, or approved alternate. k. Staples - 5/8 inch x l/2inch, stainless steel, A. J. Gerrard or approved alternate. l. Adhesive Cement - Miracle Adhesive Type H or ap proved alternate. m. Fabricating Cement - Miracle Adhesive RT-1000 P or approved alternate. H. SPECIFICATION 10-H A. MATERIAL - contd 3. Accessory Materials - contd n. Heat Resistant Sealer - Benjamin Foster No. 30-43 or approved alternate. o. Glass Wool Blanket - White glass wool. Hex Nett ing one side, expanded metal lath on other side Fiber-glas Metal Mesh Blanket. p. Insulating Cement - Hydraulic setting - BaldwinHill Powerhouse, Eagle Picher one coat o r ap proved alternate. 4- - n. SPECIFICATION 10-H B. APPLICATION 1. Equipment a. Insulation Supports Equipment shall be provided with insulation supports as called for in the GENERAL SPECIFICATIONS, Part I. B.4. b. Thickness Schedule Unless otherwise specified, insulation in excess of 2-l/2inches total thickness shallbe applied in multiple layers as specified in GENERAL SPECIFICATIONS, Part I. B. 1. c. Cushioning Blanket (1) On horizontal equipment, a one-half inch thick blanket shall be applied over the entire surface, as a cushioning material, prior to the application of the cellular glass insulation. (2) On vertical equipment, two layers of one-half inch thick cushioning material shall be applied over the top head, and one layer of one-half inch thick cushioning material over the sides and bottom head. Blanket shallbe secured in place with a minimum amount of No. 18 gage stainless steel wire. Cellular glass insulation shall then be applied over blanket in manner described in this specification. Cushioning material will not be con sidered as part of the specified insulation thickness. d. Curved Surfaces Cellular glass block insulation (curved segments or shaped head segments) shall be shop fabricated and fitted to a one-inch greater diameter than that of the -5- II. SPECIFICATION 10-H B. APPLICATION - contd 1. Equipment - contd d. Curved Surfaces - contd vessel to which it is applied. Block insulation shall be applied to equipment with all joints tightly butted. Multiple layers of insulation shall be so applied that the butt joints of one layer do not coincide with those of any other layer. Typical installation is shown on Figure 10-H-l. APPLICATION OF CELLULAR GLASS INSULATION TO VESSEL HEAn a NOZZLE fl. IO-M-1 e. Flat Surfaces Flat block shall be applied to flat surfaces in the same manner as previously specified for curved surfaces when operating temperature of equipment is in excess of 150 F. When operating temperature of equipment is 150F or below, cushioning material will be omitted and block applied directly to metal surfaces. Securement shall be as specified in the Insulation Design Schedule and/or Line List. 6- - II. SPECIFICATION 10-H B. APPLICATION - contd 1. Equipment - contd f. Securement (1) Where contour of vessel permits firm and effective attachment, all layers of cellular glass insulation shall be secured in place with stainless steel in sulation strap. Insulation applied to irregular surfaces, where use of insulation strap is im practicable, shall be secured with No. 18 gage stainless steel wire. (2) Inner layer or layers of cellular glass insulation on bottom heads of vertical equipment or heads of horizontal equipment shall be held in place with specified stainless steel wire secured to support as shown in UCCC Standards IS-21, IS-36, and IS-42. Outer layer of cellular glass insulation on bottom heads of vertical equipment, or heads of horizontal equipment shall be secured with insu lation strap as shown in Figure 10-H-2. SECUREMENT FQR BOTTOM HEAP INSULATION ON WELOED PISHED HEAP VESSELS <J >0 - I -cta.i. straV anchor-cu* tTAiMittS JTttt (mars Q*AN) II. SPECIFICATION 10-H B. APPLICATION - contd 1. Equipment - contd f. Securement - contd Where specified, block shall be applied directly to metal surfaces, such as duct work, with ad hesive or other approved securement. Where block is specified to be secured with adhesive, it shall be embedded firmly into a surface coat. g. Expansion joint (1) Cellular glass applications shall be provided with expansion joints at vessel flanges constructed as shown in Figure 10-H-3. 1 ; f r II. SPECIFICATION 10-H i B. APPLICATION - contd i 1. Equipment - contd g. Expansion Joint - contd r t (2) Longitudinal expansion of vessels shall be provided by installing expansion joints at the insulation T supports as shown in Figure 10-H-4. When more than one thickness is specified for a vessel, an i insulation support shall be provided at the junction of two different thicknesses and insulated in similar manner as shown in Figure 10-H-4. f .i i jj 1 L I ! L Q II. SPECIFICATION 10-H B. APPLICATION - contd 1. Equipment - contd g. Expansion Joint - contd (3) One inch of cushioning material shall be packed around nozzles and projections where they extend through the insulation, to prevent crushing of the insulation by contraction and expansion of the vessel. Typical application is shown in Figure 10-H-5. APPLICATION OF CELLULAR GLASS INSULATION TO NOZZLE fit 10 II. SPECIFICATION 10-H B. APPLICATION - contd 1. Equipment - contd g. Expansion Joints - contd (4) Corrugated mechanical expansion joints on piping (usually listed as equipment item) where cellular glass products are specified shall be as shown in Figure 10-H-6. APPLICATION OF CELLULAR GLASS INSULATION TO A MECHANICAL EXPANSION JOINT fig io-h-6 -ii- II. SPECIFICATION 10-H B. APPLICATION - contd 1. Equipment - contd g. Expansion Joints - contd (5) Expansion joints in flat surfaces or cylindrical vessels shall be insulated with flexible blanket in sulation to permit movement of the expansion joint. Typical installation is shown in Figure 10-H-7. GLASS wool metal mesh blanket OF SPECIFIED THICKNESS FACES OUTSlOE WITH CENTERS STAGGENEO NOTE VOtOS OF EXRANOEO METAL LATH TO BE FillEO WITH HTORAULlC SETTING CEMENT TROWELED FLUSH WITH SURFACE OF LATH APPLICATION OF BLANKET INSULATION TO EXPANSION JOINTS ON FLAT SURFACE II. SPECIFICATION 10-H B. APPLICATION - contd 1. Equipment - contd i. Flat Heads (1) Insulation on top flat heads of vertical equipment shall be applied in the same manner as previously described in this specification. Water pockets shall be eliminated and proper drainage provided as shown in Figure 10-H-8. (2) All nozzles on top of insulated equipment shall be provided with flashing as shown in Figure GA-3 , of GENERAL SPECIFICATIONS. II. SPECIFICATION 10 -H B. APPLICATION - contd 1. Equipment - contd j. Vessel Legs (1) Vessel legs shall be insulated with block which shall extend over channel flanges and down channel legs to junction with any fire resistant material. Thickness shall be one-half that specified for body of vessel. Body insulation shall be brought up to and butted firmly against tank leg flange. (2) Re-entrant space between channel flanges and over channel flanges between body insulation shall be filled with block cemented in place with an approved adhesive. Surface of f ireproofing material abutting tank leg insulation shall be coated with specified weathercoating. Installation shall be as shown in Figure 10-H-9. J ( II. SPECIFICATION. 10-H B. APPLICATION - contd 1. Equipment - contd k. Vessel Skirts Skirts supporting vertical equipment shall be insulated outside. Insulation shall extend downward, from junc tion of skirt with bottom head, a distance of not less than four'times the specified thickness or to concrete pad, whichever is nearer. Where specified, entire surface of skirt shall be insulated. Thickness shall be as specified for body of vessel. An insulation support shall be provided for securementof bottom head insula tion in accordance with UCCG Standard IS-42. In stallation shall be as shown in Figure 10-H-10. ( 1 11 'L i ? APPLICATION OF CELLULAR GLASS INSULATION TO EQUIPMENT SKIRT I HO. I&-H.IO 1 15 II. SPECIFICATION-10-H B. APPLICATION - contd 1. Equipment - contd 1. Weather-Barrier (1) Weather - barrier shall be applied in accordance with GENERAL SPECIFICATION I. B. 9 and 16. (2) Weather-barrier membrane shall be carried out 3 inches onto any metal, beyond termination of in sulation. Where operatingtemperatures are above 300 F, the portion of the weather-barrier in con tact with metal shall consist of reinforcing cloth embedded in heat resistant sealer instead of the weather-coating. A second application of the heat resistant sealer shall then be appliedover the re inforcing cloth and, while still tacky, the weather membrane shall be secured with strap where prac tical. Securement shall then be coated with heat resistant sealer. Typical installation is shown in Figure 10-H-ll. 16 II. SPECIFICATION 10-H B. APPLICATION - contd 2. Piping a. Pipe Insulation (1) Insulation thicknesses in excess of 2-1/2 inches shall be applied in multiple layers as specified in GENERAL SPECIFICATIONS, I. B. 4. (2) Pipe insulation shall be applied to piping in a staggered position in accordance with Figures GA-1 and GA-2 of the GENERAL SPECIFICATION. (3) Piping, operating at temperatures 350 F and below, . shall have one-half inch thick preformed cushion ing material applied prior to application of cellular glass insulation and secured with a minimum of four (4) staples per three foot section. Piping operating at temperatures above 3 50 F, or where preformed cushioning material is not available, shall have one-half inch thick cushioning blanket secured with glass tying cord, applied prior to application of insulation. Cushioning material shall not be considered as part of insulation thick ness. (4) Insulation shall be applied with all joints tightly butted and fitted, to eliminate voids. Large voids shall not be filled with weather-barrier coating, but eliminated either byrefitting or replacing in sulation. Any rounded corners on the insulation surfaces to be butted shall be trued before appli cation. (5) Butt edges and ends of all inner layers shall be given a smooth brush or spray coat of anti-abrasion coating and allowed to dry for a minimum of onehalf hour, but preferably two hours, before appli cation. Care shall be exercised to obtain a thin even coat of sufficient thickness only to cover and fill the cut cells of the insulation. II. SPECIFICATION 10-H B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers (1) Welded fitting covers shall be fabricated to an in side diameter one-inch greater than the outside diameter of the welded fitting to allow for cushion ing material. (2) Fitting, flange and valve covers shall be shop fab ricated in accordance with the UCCC Dimensional Standards Fabrication Manual. Installation of typical fittings and valves are shown in Figures 10-H-12, 10 -H -13, 10-H-14, 10-H-15, 10-H-16. APPLICATION OF CELLULAR GLASS INSULATION TO WELDED FI L - IS II. SPECIFICATION 10-H B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd APPLICATION OF CELLULAR GLASS INSULATION TO WELDED TEE nc io-h-ij AOUMO OUTSIOC COHAIAS CAVT F.LCT or CAULKin4 MASTIC TMtCKNCSS T, AS srccinto APPLICATION OF CELLULAR GLASS INSULATION TO LINE FLANGE rid. 19 II. SPECIFICATION 10-H B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers contd APPLICATION OF CELLULAR GLASS INSULATION TO FLANGED ELL ntte-M-is I *9 5PCCm<0 APPLICATION OF CELLULAR GLASS INSULATION TO FLANGED VALVE II. SPECIFICATION 10-H B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd (3) All valves shallbe packed andfilled around valve stem and packing gland as s embly with heat re sistant sealer to avoid water pocket. (2) Cementing of shop assemblies shallbe done with specified fabricating cement. In all cases the joints shallbe as thin as possible with just suffi cient cement to obtain good adhesion and complete closure. In no case will wide cement joints, or voids and holes plugged with cement, be permitted. c. Securement (1) All layers of cellular glass pipe insulation shall be secured with insulation strap. (2) Location of strap shallbe as described in the GENERAL SPECIFICATION, I.B. 5, 6, &.7. d. Weather Barrier Coating Weather barrier shall be installed in accordance with the GENERAL SPECIFICATION, I.B. 16. -21- UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 10-J Cellular-Glass Scope This specification describes the essential requirements for the purchase and application of preformed cellular-glass insulation, for use on equipment and piping normally operating at tempera tures above 70 F and up to 500 F. It is applicable to both indoor and outdoor service. A. MATERIAL 1. Composition Material shall be composed of glass, completely inorganic, processed and molded at temperatures sufficient to pro duce a rigid, cellular thermal insulation. 2. Properties Cellular glass insulation shall have the following prop erties: Acid Resistance..............................Impervious to common acids and acid fumes. Alkalinity.............................................pH = 7. 5 Capillarity.............................................0 Combustibility......................................Incombustible Composition......................................A true glass; inorganic. completely Compressive Strength 100 lbs. per sq. in. Density............................................. 9 to 1 1 lbs. per cu. ft. H. SPECIFICATION 10-J MATERIAL - contd 2. Properties - contd Flexural Strength.... . 100 lbs. per sq. in. Hygroscopicity.............................. . No increase in weight in 246 days in air at 90% relative humidity. Modulus of Elasticity . 200, 000 lbs. per sq. in. Shear Strength.............................. . 64 lbs. per sq. in. Specific Gravity .... . 0. 16 Specific Heat.............................. Tensile Strength .... . 84 lbs. per sq. in. Thermal Conductivity . .. . Shall not exceed values at the following mean temperatures: Mean Temp.'F Conductivity Btu/hr., sq.ft. F, inch thk. 50 300 0.40 0. 55 Thermal Diffusivity . . 0.40 sq. ft. per day Water Absorption. . 0.2% by volume on 2" x 12" x 18" block (all on surface only. Temperature Limits. . Minus 350F to plus 600F. 3. Accessory Materials a. Cellular glass insulation b. Stainless Steel Wire - . 0475 inch dia. , type 304, cold drawn, bright annealed, 18 gage. n. SPECIFICATION I0-J A. MATERIAL - contd 3. Accessory Materials - contd c. Stainless Steel Insulation Strap - l/2 inch x .020 inch type 304 or approved alternate. d. Stainless Steel Die Cut Strap - 3/4inch x . 023 inch, 2-inchfingers on 9-inch centers, A. J. Gerrard or approved alternate. e. Stainless Steel Clips - Double pronged, type 304, A. J. Gerrard or approved alternate. f. Strap Anchor Clip - A. J. Gerrard's straphanger. g. Anti-Abrasion Coating - Carlon No. 500-H or ap proved alternate. h. Weather-Barrier Coating - (color as specified) Vimasco WC-1, Benjamin Foster Sealfas "C", or approved alternate. i. Reinforcing Cloth - Glass fiber, 10 x 10 thread count, Perma Glas Mesh, or approved alternate. j. Adhesive Cement - Miracle Adhesive Type H or ap proved alternate. k. Fabricating Cement - Miracle Adhesive RT-1000P or approved alternate. l. Heat Resistant Sealer - Benjamin Foster No. 30-43 or approved alternate. m. Glass Wool Blanket - White glass wool. Hex Nett ing one side, expanded metal lath on other side Fiber-glas Metal Mesh Blanket. n. Insulating Cement - Hydraulic setting - Baldwin Hill Powerhouse, Eagle Picher one coat or approved alternate. 3- - H. SPECIFICATION 10-J B. APPLICATION 1. Equipment a. Insulation Supports Equipment shall be provided with insulation supports as called for in the GENERAL SPECIFICATIONS, Part I. B. 4. b. Thickness Schedule Unless otherwise specified, insulation in excess of 2-1/2 inches total thickness shallbe applied inmultiple layers as specified in GENERAL SPECIFICATIONS, Part I. B. 1. c. Curved Surfaces (l) Cellular glass block insulation (curved segments or shaped head segments) shallbe shop fabricated to fit the d i a m e t e r of the vessel to which it is applied. Block insulation shall be applied to equipmentwithall joints tightly butted. Multiple layers of insulation shall be so applied that the butt joints of one layer do not coincide with those of any other layer. Typical installation is shown in Figure 10-J-l. 1 APPLICATION OF CELLULAR GLASS INSULATION TO VESSEL HEAD a NOZZLE nr io- j-1 4- - II. SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd c. Curved Surfaces - contd (2) Inner surface of vessel insulation shall be coated with anti-abrasion coating, of just sufficient thick ness to fill half cells, and allowed to dry before installation. d. Flat Surfaces Flat block shall be applied to flat surfaces in the same manner as previously specified for curved surfaces. e. Securement (1) Where contour of vessel permits firm and effective attachment, all layers of cellular glass insulation shall be secured in place with stainless steel in sulation strap. Insulation applied to irregular surfaces, where use of insulation strap is im practicable, shall be secured with No. 18 gage stainless steel wire. II. SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd e. Securement - contd (2) Inner layer or layers of cellular glass insulation on bottom heads of vertical equipment or heads of horizontal equipment shall be held in place with specified stainless steel wire secured to support as shown in UCCC Standards IS-31, IS-36, and IS-42. Outer layer of cellular glass insulation on bottom heads of vertical equipment, or heads of horizontal equipment shall be secured with insu lation strap as shown in Figure 10-J-2. o II SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd f. Expansion Joint (1) Cellular glass applications shall be provided with expansion joints at vessel flanges constructed as shown in Figure 10-J-3. H. SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd f. Expansion Joint (2) Longitudinal expansion of vessels shall be provided by installing expansion joints at the insulation supports as shown in Figure 10-J-4. When more than one thickness is specified for a vessel, an insulation support shall be provided at the junction of two different thicknesses and insulated in a similar manner as shown in Figure 10-J-4. -8 - II. SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd f. Expansion Joint - contd (3) Where nozzles and projections extend through the insulation, they shall be insulated as shown in Figure 10-J-5. APPLICATION OF CELLULAR GLASS INSULATION TO NOZZLE Fit. IO-y-6 II. SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd f. Expansion Joint - contd (4) Corrugated mechanical expansion joints on piping (usually listed as equipment item) where cellular glass products are specified shall be as shown in Figure 10-J-6. APPLICATION OF CELLULAR GLASS INSULATION TO A MECHANICAL EXPANSION JOINT fIf. 10 H. SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd f. Expansion Joints - contd (5) Expansion joints in flat surfaces or cylindrical vessels shall be insulated with flexible blanket in sulation to permit movement of the expansion joint. Typical installation is shown in Figure 10-J-7. SLASS WOOL METAL MESH BLANKET ON 5NEC1XIE0 THICKNESS XACEO OUTSIDE WITH EXMNOED METAL LATH ANO ON THE INStOE WITH ("HEX WINE NETTlNS----- 1 .THICKNESS T 1/2" BLANK NUTS ON OTHtN -- AMNOVED SECUNEUENT ON It' CENTENS STAOOENEO 'THICKNESS T, AS SSECIFIEO NOTE' VdOS OP EXMNOEO METAL LATH TO BE TILLEO WITH KTOHAULlC SETTlNS CEMENT TNOWELEO FLUSH WITH BUftFACE OP LATH APPLICATION OF BLANKET INSULATION TO EXPANSION JOINTS ON FLAT SURFACE Fl. IO-A-7 II. SPECIFICATION 10 -J B. APPLICATION - contd 1. Equipment - contd g. Flat Heads (1) Insulation on top lat heads of vertical equipment shall be applied in the same manner as previouslydescribed in this Specification. Water pockets shall be eliminated and proper drainage provided as shown in Figure 10-J-8. (2) All nozzles on top of insulated equipment shall be provided with flashing as shown in Figure GA-3, of GENERAL SPECIFICATIONS, I. B. 8. 12 II. SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd h. Vessel Legs (1) Vessel legs shall be insulated with block which shall extend over channel flanges and down channel legs to junction with any fire resistant material. Thickness shall be one-half that specified for body of vessel. Body insulation shall be brought up to and butted firmly against tank leg flange. (2) Re-entrant space between channel flanges and over channel flanges between body insulation shall be filled with block c emented in plac e with an approved adhesive. Surface of fir eproofing material abutting tank leg insulation shall be coated with specified weathercoating. Installation shall be as shown in Figure 10-J-9. 13 II. SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd i. Vessel Skirts Skirts supporting vertical equipment shallbe insulated outside. Insulation shall extend downward, from junc tion of skirt with bottom head, a distance of not less than four times the specified thickness or to concrete pad, whichever is nearer. Where specified, entire surfac e of skirt shall be insulated. Thickness shall be as specifiedfor body of vessel. An insulation support shallbe providedfor securementof bottom head insula tion in accordance with UCCC Standard IS-42. In stallation shall be as shown in Figure 10-J-10. APPLICATION OF CELLULAR GLASS INSULATION TO EQUIPMENT SKIRT rt. io-j-io 14 H. SPECIFICATION 10-J B. APPLICATION - contd 1. Equipment - contd j. Weather-Barrier (1) Insulation shall he coated with a weather-barrier before equipment is put in service. (2) Weather-barrier shall be applied in accordance with GENERAL SPECIFICATION, I.B. 9 and 16. (3) Weather-barrier membrane -shallbe carried out 3 inches onto any metal, beyond termination of in sulation. Where ope rating temperatures are above 300 F, the portion of the weather-barrier in con tact with metal shall consist of reinforcing cloth embedded in heat resistant sealer instead of the weather-coating. A second application of the heat resistant sealer shall thenbe applied over the re inforcing cloth and, while still tacky, the weather membrane shall be securedwith strapwhere prac tical. Securement shallthen be coated with heat resistant sealer. Typical installation is shown in Figure 10-J-ll. application of cellular glass insulation around UNINSULATED FLANGES ni o-j-u -15- II. SPECIFICATION 10-J B. APPLICATION - contd 2. Piping a. Pipe Insulation (1) Insulation thicknesses in excess of 2-1/2 inches shall be applied in multiple layers as specified in GENERAL SPECIFICATIONS, I. B. 4. (2) Pipe in s u la t i o n shall be applied to piping in a staggered position in accordance with Figures GA -1 and GA - 2 of the GENE RA L S PE CIFICAT ION. (3) Insulation shall be applied with all joints tightly butted and fitted, to eliminate voids. Large voids shall not be filled with weather-barrier coating, but eliminated either by refitting or replacing in sulation. Any rounded corners on the insulation surfaces to be butted shall be trued before appli cation. (4) Butt edges and ends of all inner layers shall be given a smooth brush or spray coat of anti-abrasion coating and allowed to dry for a minimum of onehalf hour, but preferably two hours, before appli cation. Care shall be exercised to obtain a thin even coat of sufficient thickness only to cover and fill the cut cells of the insulation. b. Fitting, Flange and Valve Covers (1) Fitting, flange and valve covers shall be shop fab ricated in accordance with the UCCC Dimensional Standards Fabrication Manual. Installation of typical fittings and valves are shown in Figures 10-J-12, 10-J-13 , 10-J-14, 10-J-15, and 10-J -16. !6 - SPECIFICATION 10-J B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd APPLICATION OF CELLULAR GLASS INSULATION TO WELDED ELL ria. lo-j-t* APPLICATION OF CELLULAR GLASS INSULATION TO WELDED TEE fl IO-J-IS II. SPECIFICATION 10-J B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd APPLICATION OF CELLULAR GLASS INSULATION TO LINE FLANGE nc I0-J-I4 I APPLICATION OF CELLULAR GLASS INSULATION TO FLANGED ELL 10n. -J-ts 18 - J { I r II. SPECIFICATION 10-J r; B. APPLICATION - contd 2. Piping - contd T b. Fitting, Flange and Valve Covers - contd I I i i i i * *i i APPLICATION OF CELLULAR GLASS INSULATION TO FLANGED VALVE i L Ft*. IO-J-1* (3) All valves shall be packed and filled around valve stem and packing gland assembly with heatresisant sealer to avoid water pocket. (4) Cementing of shop assemblies shall be done with specified fabricating c e m e n t. In all cases the joints shall be as thin as possible with just sufficientcement to obtain good adhesion and complete closure. In no case will wide cement joints, or voids andholes plugged withcement, be permitted. c. Securement (1) All layers of cellular glass pipe insulation shall L be secured with insulation strap. (2) Location of strap shall be as described in the GENERAL SPECIFICATION, I.B. 5. II. SPECIFICATION 10-J B. APPLICATION - contd 2. Piping - contd d. Steam Traced Installations Steam-trace lines, where specified, shall be installed and insulated in accordance with the GENERAL SPECI FICATION, I.B. 15. e. Weather-Barrier Coating (1) Insulation shall be coated with weather-barrier before piping is put in service. (2) Weather-barrier shall be installed in accordance with the GENERAL SPECIFICATION, I.B. 16. - 20 - UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 10-L Cellular Glass Scope This specification describes the essential requirements for the purchase and application of preformed cellular glass thermal insulation, for use on equipment and piping normally operating at temperatures below 70 F, and including cycle operation and thawout service up to 400 F. It is applicable to both indoor and outdoor service. Procedures outlined in the GENERAL SPECIFICATIONS are appli cable to and constitute an integral part of this Specification. A. MATERIAL 1. Composition Material shall be composed of glass, completely inorganic, processed and molded at temperatures sufficient to pro duce a rigid, cellular, thermal insulation. 2. Properties Cellular glass insulation shall have the following proper ties: Acid Resistance............................ Alkalinity . . . . . . . Capillarity.......................................... Coefficient of Expansion Combustibility................................... Composition................................... Compressive Strength . . . Density................................................ Flexural Strength............................ Impervious to common acids and acid fumes. pH = 7. 5 0 0.0000040 per F Incombustible A true glass; completely inorganic. 100 lb. per sq. in. 9 lbs. per cu. ft. 100 lb. per sq. in. -1- II. SPECIFICATION 10-L A. MATERIAL - contd 2. Properties - contd Hygroscopicity. . . . Modulus of Elasticity . . Shear Strength. . . Specific Gravity . . . Specific Heat Tensile Strength . . . Thermal Conductivity Thermal Diffusivity . Water Absorption. Temperature Limits. No increase in weight in 246 days in air at 90% relative humidity. 200,000 lb. per sq. in. 64 lb. per sq. in. 0.16 0 20 Btu per lb. 84 lb. per sq. in. Shall not exceed values at the following m e a n temperatures: Mean Conductivity Temp.F Btu/hr.,Sq.Ft. , F, inch Thick 50 0.40 300 0.55 0.40 sq. ft. per day 0. 2% by volume on 2" x 12" x 18" block (all on surface only) Minus 350F to plus 600F 3. Accessory Materials a. Cellular Glass Insulation b. . Cushioning Blanket - 1-1/2 lb. density, Aerowrap P-308, Fine Fyber Felt, Ultralite, Superfine, or approved alternate. c. Stainless Steel Wire - .0475 inch dia. , 18 gauge, Type 304, cold-drawn bright-annealed, stainless steel wire, or approved alternate. d. Stainless Steel Insulation Strap - 1 /2 inch x .020 inch, Type 304, or approved alternate. e. Stainless Steel Clips - Double pronged. Type 304; A. J. Gerrard, or approved alternate. f. Strap Anchor Clip - A. J. Gerrard's straphanger. - 2- H. SPECIFICATION 10-L A. MATERIAL - contd 3. Accessory Materials - contd i. Weather-Barrier Coating ( Color as specified ) PVA- Vimasco No. WC-1, Benjamin Foster Sealfas MC" , or approved alternate. j. Reinforcing Cloth - Glass fiber, 10 x 10 PermaGlas, or approved alternate. k. Adhesive Cement - Miracle Adhesive Type H, or approved alternate. l. Caulking Mastic - Vimasco Caulking Compound, or approved alternate. m. Fabricating Cement - Hot ('80F) Asphalt or ap proved alternate. n. Vegetable Cork - 16 to 20 lb. cu. ft. - National Cork, Mundet or approved alternate. o. Non-setting Sealer - Benjamin Foster 30-73, or ap proved alternate. - 3- II SPECIFICATION 10-L B. APPLICATION - contd I. Equipment - contd 1. Equipment Supports. (1) Where equipment is supported on cradles, vessel insulation shall extend over cradles as shown in Figure 10-L-10. -14 - II. SPECIFICATION 21-H A. MATERIAL - contd 2. Properties - contd Thermal Diffusivity . . Shall be approx, 0. 197 sq. ft. / day Thermal Shock Resistance . . Material shall not spall, chip, or crack, or other wise fail when heated to 750 F and then quenched with water. 3. Accessory Materials a. Asbestos Fiber Insulation - Unibestos or approved alternate. b. Wire - Stainless steel, .0475 inch dia. , type 304, cold drawn bright annealed (18 gage). c. Insulation Strap - Stainless steel, 1 /Z inch double pronged, type 304 or approved alternate. d. Clips - Stainless steel, l/2 inch double pronged, type 304, A. J. Gerrard or approved alternate. e. Insulating Cement - Hydraulic setting, Baldwin -Hill Powerhouse, Eagle-Picher One Coat or approved alternate. f. Finishing Cement - Hard surface. Eagle Picher No. 106 Johns Manville 678 or approved alternate. g. Heat Resistant Sealer - Benjamin Foster No. 30-43 or approved alternate. h. Weather Barrier Coating (Color as specified) - Vimasco WC - 1, Benjamin Foster Sealfas "C", or approved alternate. i. Reinforcing Cloth - Glass fiber, 10 x 10 thread count, Perma Glas Mesh, Glasfab or approved alternate. j. Fabricating Cement - A. P. Green "Insulation Adhe sive", or approved alternate. -3 - II. SPECIFICATION 21-H B. APPLICATION 1. Piping a. Pipe Insulation (1) Unless otherwise specified, insulation in excess of two and one-half inches total thickness shall be applied in multiple layers as specified in GENERAL SPECIFICATION, I.B. 1. (2) Insulation shall be applied to piping in staggered position in accordance with the GENERAL SPECI FICATION, I.B. 4, 5, 6, and 7, with all joints tightly butted and factory attached sheeting jacket, where furnished, removed. (3) Small cracks and depressions, where present; shall be pointed up with insulating cement troweled smooth with insulation surface. b. Fittings, Flanges and Valves (1) Fittings, flanges and valves shallbe insulated with prefabricated insulation covers fabricated in accordance with the Dimensional Standard Fabri cation Manual. (2) Where impractical to shop fabricate fitting insula tion, and with the approval of the representative of the Department of Design and Construction, fit ting covers may be fieldfabricated, provided work is in accordance with Dimensional Standard Fabri cation Data. Segments shall be carefully fitted to insure tight joints. (3) Shop fabricated assemblies shall be cementedwith specified fabricating cement. In all cases the joints shall be as thin as possible, with justsufficientcement to obtain goodadhesion and complete closure. In no case will wide fabricating cement joints, or voids and holes filled with fabricating cement, be permitted. Typical installations are shown in Figures 21-H-l, 21-H-2, 21-H-3, and 21-H-4. -4 - II. SPECIFICATION 21-H B. APPLICATION - contd 1. Piping - contd b. Fittings, Flanges and Valves - contd APPLICATION OF ASBESTOS FIBER INSULATION TO WELDING ELL no. ti-m- i orr cove* $mu e r*0.c*reo IN romACCO*OACC tfiTM FABRICATION OATA FirTma covin* APPLICATION of asbestos fiber insulation to line flange r\o n- m- t 5 II. SPECIFICATION 21-H B. APPLICATION - contd 1. Piping - contd b. Fittings, Flanges and Valves - contd PIO. 21-M- 5 I l APPLICATION or ASBESTOS fiber insulation to flanged valve rto. li6 II. SPECIFICATION 21-H B. APPLICATION - contd 1. Piping - contd b. Fittings, Flanges and Valves - contd (4) Insulating cement maybe applied as the insulating m a t e r ia 1 where fittings are 2-l/Z inch IPS or smaller and the specified insulation thickness does not exceed 1-1/2 inches. Cement shall be of same thickness as specified for adjacent pipe insulation. c. Securement (1) Application and securement of pipe insulation shall be as described (and shown in Figures GA-1 and GA-2) in the GENERAL SPECIFICATION. (2) All inner layers of sectional pipe insulation shall be secured with stainless steel wire. (3) All sectional pipe insulation having outside dia meters of 6.625 inches or less shall be secured with stainless steel wire. (4) All pipe insulation having outside diameters greater than 6.625 inches shall be secured with stainless steel insulation strap. (5) Fitting, flange and valve covers shalt be secured with specified insulation strap as required. 7 H. SPECIFICATION 10-L B. APPLICATION 1. Equipment a. Insulation Supports Equipment shall be provided with insulation supports as specified in GENERAL SPECIFICATIONS I.B.4. b. Thickness Schedule Unless otherwise specified, insulation in excess of 2-1/2 inches total thickness shall be applied in multi ple layers as specified in GENERAL SPECIFICATIONS I.B. 1. c. Cushioning Blanket On all equipment, a one-half inch thick blanket shall be applied over the entire surface, as a cushioning material prior to the application of the cellular glass insulation. Blanket shallbeheld in place with a mini mum amount of No. 18 gage, stainless-steel wire. Cellular glass insulation shall then be applied over blanket in manner described in this Specification. Cushioning material shall not be considered as part of the specified insulation thickness. d. Curved Surfaces (1) Block insulation (curved segments orshapedhead segments) shall be shop fabricated andfitted to a one-inch greater diameter than that of the vessel to which it is applied. Block insulation shall be applied over cushioning material on all equipment, with all joints tightly butted. Multiple layejrs of insulation shall be applied so that the butt joints of one layer do not coincide with those of any other layer. (2) Allbutt edges and ends of insulation fabricated for inner layer or layers shall be given a smooth brush or spray coat of anti-abrasion coating and allowed to dry for a minimum of one-half hour, but preferable two hours, before application of insulation to equipment. -4- II. SPECIFICATION 10-L B, APPLICATION - contd 1. Equipment - contd d. Curved Surfaces - contd (3) All butt edges and ends of outermost layer (or single layer) of formed insulation shall be sealed with a buttered coat of Vinyl Asphalt Joint Sealer. This coating shall be of sufficient thickness to provide proper adhesion, seal and cushion, between the individual pieces of insulation. Typical installa tion is shown in Figure 10-L-l. PnJ.CH BLOCS OP CELLULAS CLASS LEVEL VMTH TOP OP STUOS APPLICATION op CELLULAR GLASS INSULATION TO VESSEL HEAD AND NOZ2LE PIC. IO-L-I e. Flat Surfaces Block shall be applied to flat surfaces, in the same manner as specified for curved surfaces, except where it is specified to be applied directly to metal surfaces with adhesive or other approved securement. -5- II. SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd f. Securement (1) Where contour of vessel permits firm and effective attachment, all layers of cellular glass insulation shall be secured in place with stainless steel in sulation strap. Insulation shall be secured to ir regular surfaces, with No. 18 gage stainless steel wire. (2) Inner layer or layers of cellular glass insulation on bottom heads of vertical equipment, or heads of horizontal equipment, shall be held in place with specified stainless-steel wire securedto insulation supports, as shown in UCCC Standards IS-31, IS-36, and IS-42. Any slots cut in the cellular glass insulation resulting from tightening of the tie wires, shall be filledwith specified joint sealer. Outer layer of cellular glass insulation on bottom heads of vertical equipment, or heads of horizon tal equipment, shall be secured with insulation strap, as shown in Figure 10-L-2. -6 - I r- II. SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd f. Securement - contd (3) Where specified, block shall be applied directly to metal surfaces, such as duct work, with ad hesive or other approved securement. Where block is specified to be secured with adhesive, it shall be embedded firmly into a surface coat. g. Expansion Joint (1) Cellular glass applications shall be provided with expansion - contraction joints at vessel flanges, t constructedas shown in Figure 10-L-3. Where ! movement is likely to occur, non-setting sealer I. shall be applied to surfaces of insulation, as shown, to provide proper slip joint. ] i I ! I ! L -7- II. SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd g. Expansion Joints - contd (2) Longitudinal contraction of vessels shall be pro vided for by installing expansion-contraction joints at the insulation supports, as shown on Figure 10-L-4. Where more than one thickness of insula tion is specifiedfor a vessel, an insulation support shall be provided at the junction of two different thicknesses, and insulated in a manner similar to that shown in Figure 10-L-4. Non-setting sealer shall be applied to surfaces of insulation, to pro vide proper slip jointwhere movement is likely to occur. -8 - II. SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd g. Expansion Joints - contd (3) One-inch of cushioning blanket shall be packed around nozzles and projections where they extend through the insulation, as shown in Figure 10-L-5. Where movement is likely to occur, non-setting sealer shall be applied to surfaces of insulation to provide proper slip joint. -9 - II. SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd h. Mechanical Expansion Joints Corrugated mechanical expansion joints in piping (usually listed as equipment items) shall be insulated as shown inFigure 10-L-6. Where movement is likely tooccur, non-setting sealer shall be appliedto surfaces of insulation to provide proper slip joint. 10 - II. SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd i. Flat Heads (1) Insulation on top flat-heads of vertical equipment shall be applied in the same manner as previously described in this specification. Water pockets shall be eliminated and proper drainage provided as shown in Figure 10-L-7. (2) All top nozzles on insulated equipment shall be provided with flashing as shown in Figure GA-3, of GENERAL SPECIFICATIONS. WEATHER* BARRIER AS SPCCIFICO MUtVoVCR STUO TREAT INNER UKTER UTT JOINTS WITH ANTIAMASJON COATING ft ALLOW TO OUT BEFORE INSTALLATION FLASHING AS PER GA-4 VESSEL NOZZLE TWO LAYERS OF CUSHiONINft SLANXCT OUTER LAYER BUTT JOINTS SMALL SC COATCO WITH JOINT SEALER HEAVY FILLET OF CAULK IMG MASTIC LOW TEMPERATURE VESSEL CELLULAR GLASS BLOCK ON CMC TO SUPPORT FLANGE INSULATION SURFACES OF CELLULAR GLASS SMALL SE COATCO ANTl--ABRASION COATING AT TIME OF INSTALLATION. BLOCK SHALL BE INSTALLCO WHILE COAT IS STIU. TACKY CUSHIONING BLANKET THICKNESS T, AS SPCCIFICO APPLICATION OF CELLULAR GLASS INSULATION TO P,AT EQUIPMENT HEAP- - li II. SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd j. Vessel Legs (1) Vessel legs shall be insulated with block which shall extend over channel flanges and down channel legs to the junction with any fire resistant material, or a distance of four times insulation thickness, but notless than 24 inches. Thickness shall be as specified for body of vessel but never less than two inches. Body insulation shall be butted firmly against tank leg flange. (2) Re-entrant space between channel flanges shall be filled with block cemented in place with an approved adhesive. Surface of fire-resistant material abutting tank leg insulation shall be coated with weather - barrier coating. Installation shall b" as shown on Figure 10-L-8. - 12 - SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd k. Vessel Skirts Skirts supporting vertical equipment shall be insulated inside and outside. Insulation shall extend downward, from junction of inside of skirt with insulated bottom head, a distance of not less than four times the thick ness of insulation, but never less than one foot. Thick ness of insulation over skirts shall be as specified for body of vessel, but never less than two inches. Insulat ing material shall be secured to inside of skirt with adhesive cement. Support for inside skirt insulation, and bottom head insulation shall be in accordance with UCCC Standard IS-42. Installation shall be as shown in Figure 10-L-9. cxpaasioh a*act suwoiiT kins PETAll A APPLICATION OF CELLULAR GLASS INSULATION TO EQUIPMENT SKIRT hg.io-l- * II. SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd 1. Equipment Supports - contd (2) Where equipment is supported by structural steel members, insulation shall extend not less than four times the specified insulation thickness in each direction, measured from junction of vessel with insulated support lug. Thickness of insulation over steel supports shall be not less than one-half that specifiedfor body of vessel. Thickness of insula tion over support lugs shall be the same as body insulation. Installation shall be as shown in Figure 10-L-ll. II. SPECIFICATION 10-L B. APPLICATION - contd 1. Equipment - contd m. Weather-Barrier Weather-barrier shall be applied in accordance with GENERAL SPECIFICATION, I.B. 9 and 16. 2. Piping a. Pipe Insulation (1) Insulation thickness in excess of 2-1/2 inches shall be applied in multiple layers as specified in GENERAL SPECIFICATIONS, I. B. 4. (2) Pipe insulation shall be applied in staggered posi tion, in accordance with figures GA-1 and GA-2 of the GENERAL SPECIFICATIONS, I.B. 5. (3) All butt edges and ends of single layer insulation, and outer layer of multiple layer applications, shall be buttered with joint sealer before applica tion. The joints shall be drawn together, when insulation is applied, so that only a very thin, vapor-tight, vapor-seal coat separates the sections of insulation. (4) Insulation shall be applied with all joints tightly butted and fitted, to eliminate voids. Large voids shall not be filled with vapor seal coating, but eliminated either by refitting or replacing insula tion. Any rounded corners, on the insulation sur faces to be butted, shall be trued before application. (5) Butt edges and ends, of all inner layers, shall be given a smooth brush or spray coat of anti-abrasion coating and allowed to dry for a minimum of onehalf hour, but preferably two hours, before appli cation. Care shall be exercised to obtain a thin even coat of sufficient thickness only to cover and fill the cut cells of the insulation. II. SPECIFICATION 10-L B. APPLICATION - contd 2. Piping - contd a. Pipe Insulation - contd (6) When scheduled for installations where severe vi bration is expected, entire surface area shall be coated with anti-abrasion coating. (7) When scheduled for installations where thermal shock is expected, a cushioning material, as speci fied, shall be applied to bare pipe prior to appli cation of cellular glass insulation. b. Fitting, Flange and Valve Covers (1) Fittings, flanges, and valve covers shall be shop fabricated, in accordance with the TJCCC Dimen sional Standards Fabrication Manual, using hot (180F) Asphalt as a Fabricating Cement. (2) Welded fitting covers shall be fabricated to fit snugly on the pipe. The two halves of the cover shall be cemented together, with joint sealer ap plied to the outermost 2-1/2 inches (approx.) of the faces of the joint. The adjacent pipe insulation shall be fitted tightly to the butt ends of the fitting cover and sealed as specified for piping. Typical fitting covers are shown in Figures 10-L-12 and 10-L-13. 17 - SPECIFICATION 10-L B. APPLICATION - contd 2. Piping - contd b. Fittings, Flange and Valve Covers - contd APPLICATION OF CELLULAR GLASS INSULATION TO WELOEO TEE flO.lO-l.-l3 18 II. SPECIFICATION 10-L B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd (3) Flanges, flanged fittings and flanged valve covers shall be fabricated and fitted to extend over ad jacent pipe insulation so as to provide a close fit ting slip joint at each end. The two halves of the cover shall be cemented together with joint sealer, appliedto the outermost 2-1/2 inches (approx.) of the faces of the joint. (4) All valves shall be packed and filled around valve stem, and packing gland assembly, with valve sealer, to avoid water pockets. (5) Installation of typical fittings and valve are shown in Figures 10-L-14, 10-L-15, and 10-L-16. THE TWO HALVES OF THE COVE* SHALL 8E CEMCMTEO TOGETHER WITH JOINT SEALER APPUEO TO THE OUTERMOST 2 1/2" (APPROX.) OF THE JOINT FACES ROUNO OVTSIOC CORNERS HEAVY FILLET OF CAULKING MASTIC SURFACES COATEO WITH NON-SETTING SEALER AMO AU.OWCO TO ORT MFORE INSTALLATION , THICKNESS T. AS 3FECIFIE0 weather-barrier AS SPECIFIED application of cellular glass insulation to line flange - 19 - II. SPECIFICATION 10-L B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd APPLICATION OF CELLULAR GLASS INSULATION TO FLANGED VALVE 10- L - H 20 H. SPECIFICATION B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd (6) Allfittings shall be fitted and assembled with very thin, tight joints. Cementing of shop assemblies shall be done with hot (180) asphalt of approved quality. In all cases the joints shallbe thin, with just sufficient asphalt to obtain good adhesion and complete closure. Wide asphalt joints, voids, or holes plugges with asphalt, will not be permitted. c. Securement (1) All layers of cellular glass pipe insulation shall be secured with insulation strap. (2) Use and location of strap shall be as described in the GENERAL SPECIFICATIONS, I.B. 5,6, and 7. d. Supports and Hangers (1) Where horizontal, low temperature piping is sup ported on the outside of insulation surfaces, as per UCCC Std. IS-19, insulation shallbe complete with weather-barrier applied before piping is placed in cradles. UCCC Std. IS-19 is a guide to the maximum horizontal span of pipe which may be supported on the outside of insulation. (2) On all vertical piping, where the operating tem perature does not exceed 250F, and any addit ional piping specified on the insulation drawings or by a Field Representative of the Design and Construction Department, supported on the out side of insulated surfaces, as per UCCC Std. IS19, the insulation between cradle and pipe shall be prefabricated heavy density vegetable cork. For piping in excess of 250F, the insulation between cradle and pipe shall be cellular glass. -21- II SPECIFICATION 10 -L B. APPLICATION - contd 2. Piping - contd d. Supports and Hangers - contd (3) Hangers attached directly to piping shall be in sulated as shown in Figure 10-L-17. 22 II. SPECIFICATION 10 -L B. APPLICATION - contd 2. Piping - contd e. Expansion-Contraction Joints (1) Expansion and contraction joints shall be installed, as per Figure 10-L-18, in both horizontal and vertical straight run piping, at intervals as follows: Single layer - one for each 45 feet. Double layer - one for each 33 feet. Triple layer - one for each 21 feet. (2) Where flanged joints occur within these limits, expansion and contraction shall be provided for in the flange cover and expansion-contraction joints in insulation will not be required. (3) Joints shall be packed tightly with strips of cush ioning blanket. CELLULAR GLASS INSULATION, inner ano outer RONE OF SLIP JOINTS COATED MH NON-SETTING SEALER JOINT SEALER '*" INTO SPACE-. LOW TEMPERATURE PIPE WEATHEfR BARRIER--' AS SPECIFIC!) W V->- >, ONE LAYER INSULATION CONTRACTION JOINT REQUIRED EVERT 43*. OF STRAIGHT RUN WEATHER-8ARRICR AS SPCCIFlCO CELLULAR GLASS INSULATTON . a'* INNER ANO OUTER SORE Of ' SLIP JOINTS COAT CO WITH NOW--SETTING sealer THREE LAYER INSULATION CONTRACTION POINT REQUIRED EVERY 21* 05 STRAIGHT RUN ' ^ V ^ ?. \ Vv .:vu-yysr LOW TEMPERAniRE PIPE 3z 3.j3y2JyZ 3CUSHIONING BLANKET WCAT>R-aARRlCR AS SPCClFICO JOINT SEA PWESSEO '| TWO LAYER INSULATION CONTRACTION joint required EVERY 33` OF STRAIGHT RUN NOTE'ALL INNER LATER BUTT JOINTS COATED WITH ANTI-ABRASION COATING ANO ALLOWED TO ORT BEFORE IIOTALLATKM ALL OUTER LATER SUIT JOINTS C0ATC0 WITH JOINT SCALER APPLICATION OF CELLULAR GLASS INSULATION TO EXPANSION S CONTRACTION JOINT IN HORIZONTAL PIPING FIO.IO-L-lS - 23 II. SPECIFICATION 10-L B. APPLICATION - contd 2. Piping - contd e. Expansion-Contraction Joints - contd (5) Where it is necessary to install expansion -con traction joints in insulation on vertical piping, an insulation support shall be provided. Installation shall be as shown in Figure 10-L-19. f. Steam-Traced Installations Steam-trace lines, where specified, shall be installed and insulated in accordance with the GENERAL SPECI FICATION, I.B.15. g. Weather-Barrier Coating Weather-barrier shall be installed in accordance with the GENERAL SPECIFICATION, l.B. 16. 24 of 24 UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 16-H Preformed Glass Fiber Scope This specification described the essential requirements for the purchase and application of preformed glass fiber thermal insulationfor use on piping and equipment normally operating between 71 F up to and including 350F. It is applicable to both indoor and outdoor service. Procedures outlined in the GENERAL SPECIFICATIONS a r e applicable to and constitute an integral part of this specification. A. MATERIAL 1. Composition Material shall be composed offiberous glass, with phenolformaldehyde binder formed into mouldedblock and pipe insulation with a factory applied canvas jacket. 2. Properties Glass fiber insulation shall have the following properties: Acid Resistance . . . .Good resistance except to Hydrofluoric and Phosphoric. Alkalinity............................... . pH = 6 to 7 Capillarity................................ . Negligible after 24 hours Combustibility.... . Will not support com bustion. Compressive Strength . Shall be not less than Percent Deflection Load.psi 5 0. 24 10 0.49 Density...................................... . 3 lbs. /cu. ft. (minimum) -1- II. SPECIFICATION 16-H.... A. MATERIAL - contd 2. Properties - contd Hygroscopicity. Specific Gravity . Temperature Limits . Thermal Conductivity Thermal Diffusivity . Water Absorption . 3. Accessory Materials 1.13% by wt. after 72 hours. Shall be not less than Apparent 0.047 True 2.572 350F (min.) Shall not exceed values at the following mean temperatures: Mean Conductivity Temp.F Btu/hr. , sq.ft. F, inch thick 70 0.30 0.32 sq. ft. per day 90 - 93% by volume a. Glass Fiber Insulation (with 6 ounce (minimum) canvas jacket) - Fiberglas Standard Pipe Insulation. GustonBacon snap-on, or approved alternate. b. Stainless Steel Wire- 0.0475 inch diameter, type 304, cold drawn, bright annealed, 18 gage. c. Stainless Steel Insulation Strap - 1/2 inch x 0.020 inch, type 304, or approved alternate. d. Stainless Steel Clips - Double pronged, type 304 A J Gerrard, or approved alternate. e. Weather-Barrier Coating (color as specified) PVA- Vimasco No. WC-1, Benjamin Foster Sealfas "C" or approved alternate. f. Paste-Benjamin Foster 81-42 W Lagfas, or approved alternate. -2- n. SPECIFICATION 16-H B. APPLICATION 1. Equipment a. Insulation Support Equipment shall be provided with insulation supports as specified in GENERAL SPECIFICATION I. B. 4. b. Thickness Schedule Unless otherwise specified, insulation shall be applied in a single layer. c. Curved Surfaces (1) Insulation for equipment, having diameter less thanfour feet, shall be factory formed to specified radius. Insulation for larger equipment shall be bent, and kerfed where necessary, to fit vessel contour. (2) Insulation shall be installed with all joints tightly butted and circumferencial butt joints staggered. d. Flat Surfaces Block insulation shall be applied to flat surfaces in the same manner as specified for curved surfaces. e. Securement (1) Insulation shall be secured with insulation strap where contour of vessel permits firm and effective attachment. Insulation applied to irregular sur faces, where strap is impracticable, shall be se cured with wire, drawn taut, ends twisted and embedded in insulation. (2) Insulation on bottom heads of vertical equipment shall be secured in place with insulation strap attached to insulation support as shown in UCCC Standard IS-31. -3- n. SPECIFICATION 16-H B. APPLICATION - contd 1. Equipment - contd f. Surface Finish (1) Cracks and depressions in insulation shall be pointed and leveled smooth with insulation surface prior to application of weather-barrier coating finish. (2) Weather-barrier coating shallbe applied over in sulation in accordance with GENERAL SPECIFI CATION I. B. 16, where curved block is not fur nished with canvas jacket. When canvas is attachedtoblock, from factory, glass fiber reinforcing cloth in weather-barrier coating shallbe omitted. 2. Piping a. Pipe Insulation (1) Thickness Schedule Unless otherwise specified, insulation shall be applied in a single layer with attached canvas jacket lapped and sealed with specified paste . (2) Securement (a) Insulation shallbe applied to piping in accord ance with GENERAL SPECIFICATIONS I.B. 4,5,6, and 7. (b) All sectional pipe insulation having outside diameters of 6.625 inches or less shallbe secured with stainless steel wire. (c) All pipe insulation having outside diameters greater than 6.625 inches shallbe secured with stainless steel insulation strap. b. Fitting, Flange and Valve Covers (I) Fittings , flanges and valve covers shallbe either factory moulded or prefabricated in accordance with UCCC Dimensional Standards Fabrication Manual. -4- II. SPECIFICATION 16-H B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd (2) Fittings, flanges and valve covers maybe field fabricated, providing work is approved by the field representative of the Department of Design and Construction. Segments shall be carefully fitted to insure tight joints. (3) Prefabricated covers shallbe secured with wire or strap as required. c. Steam Traced Installations Ste am trace-line s, where specified, shallbe installed in accordance with GENERAL SPECIFICATIONS I. B. 15. d. Surface Finish (1) Piping exposed to view or weather (a) Where present, cracks and depressions in canvas jacket shall be filled with weatherbarrier coating and trowelled smooth with adjacent surface prior to application of weather-barrier coating finish. (b) Weather-barrier coating shall be applied over canvas jacket in accordance with GENERAL SPECIFICATION I. B. 16, except glass fiber reinforcing cloth will be omitted. (2) Piping concealed Finish other than factory applied canvas will not be required. -5- UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 16-L Preformed Glass Fiber Scope This specification describes the essential requirements for the purchase and application of preformed glass fiber thermal insu lation for use on piping and equipment normally operating at temperatures between 35F and 70F. It is applicable to both indoor and outdoor service. Procedures outlined in the GENERAL SPECIFICATIONS are applicable to and constitute an integral part of this specification. A. MATERIAL 1. Composition Material shall be composed of fiberous glass, with phenolformaldehyde binder, formed into moulded block and pipe insulation with a factory applied vapor barrier . 2. Properties Glass fiber insulation shall have the following properties: Acid................................. . . Good resistance except to Hydrofluoric and Phosphoric. Alkalinity................................ pH = 6 to 7 Capillarity................................ Negligible after 24hours. Combustibility.......................... Will not support com bustion. Compressive Strength . . Shall be not Percent Deflection 5 10 less than Load.psi 7Z4 .49 Density 3 lbs. /cu. ft. (minimum) -1- II. SPECIFICATION 16-L A. MATERIAL - contd 2. Properties - contd Hygroscopicity. . . 1.13% by wt. after 72 hours. Specific Gravity . . . Shall be not less than Apparent 0.047 True 2.572 Thermal Conductivity . . Shall not exceed values at the following mean temperatures: Mean Conductivity Temp.F Btu/hr., sq.ft. F,inch thick 70 0.30 Thermal Diffusivity . . . 0.32 sq. ft. per day Water Absorption. . . 90 - 93% by volume. 3. Accessory Materials a. Glass Fiber Insulation - Fiberglas white dual temp. Pipe Insulation, Gustin-Bacon Snap-on with Kraft foil laminate vapor barrier, or approved alternate. b. Stainless Steel Wire-0.0475 inch diameter, type 304, cold drawn, bright annealed, 18 gage. c. Stainless Steel Insulation Strap - l/2 inch x 0.020 inch, type 304, or approved alternate. d. Stainless Steel Clips - Double pronged, type 304, A. J. Gerrard, or approved alternate. e. Vapor-Barrier - Foil (0.001 min.) - Scrim-craft,or approved alternate. (May be factory attached.) f. Reinforcing Cloth - Glass Fiber, approximately 10 x 10 mesh, with starch binder, Perma-Glas- Mesh, Benja min Foster, Open Weave, or approved alternate. II. SPECIFICATION 16-L A. MATERIAL, - contd 3. Accessory Materials - contd g. Weather-Barrier Coating - (color as specified) - PVA Vimasco No. WC-1, Benjamin Foster Sealfas "C", or approved alternate. h. Joint Sealer Strips - Foil (.001" min.) with Kraft paper backing in three inch wide rolls. i. Lap and Strip Adhesive - Benjamin Foster 81-71, Minnesota Mining #1128, St. Clair Rubber Adhesive No. 4815, or approved alternate. -3- II. SPECIFICATION 16-L B. APPLICATION 1. Equipment a. Insulation Support Equipment shall be provided with insulation supports as specified in GENERAL SPECIFICATION I. B. 4. b. Thickness Schedule Unless otherwise specified, insulation shall be applied in a single layer. c. Curved Surfaces (1) Insulation for equipment, having diameters less than four feet, shall be factory formed to specified radius. Insulation for larger equipment shall be bent, and kerfed where necessary to fit vessel contour. (2) Insulation shall be installed with all joints tightly butted and circumferencial butt joints staggered. d. Flat Surfaces Block insulation shall be applied to flat surfaces in the same manner as specified for curved surfaces. e. Vapor Barrier All joints, cracks, and breaks in vapor barrier shall be sealed with three inch wide vapor barrier strips cemented to adjacent vapor barrier to form a con tinuous vapor tight envelope. f. Securement (1) Insulation shall be secured with insulation strap where contour of vessel permits firm and effective attachment. Insulation applied to irregular sur faces where strap is impracticable, shall be se cured with wire, drawn taut, ends twisted and em bedded in insulation. -4- II. SPECIFICATION 16-L B. APPLICATION - contd 1. Equipment - contd f. Securement - contd (2) Insulation on bottom he ads of vertical equipment shall be secured in place with insulation strap attached to insulation support as shown in UCCC Standard IS-31. g. Surface Finish (1) Where present, cracks, holes and depressions in vapor barrier jacket shall be filled with weather coating and trowelled smooth with adjacent sur face prior to application of weather-barrier coat ing finish. (2) Weather coating shall be applied over vapor barrier jacket in accordance with GENERAL SPECIFICATION I. B. 16. 2. Piping a. Pipe Insulation (1) Thickness Schedule Unless otherwise specified, insulation shall be appliedin a single layer with attached vapor bar rier tightly sealedto form a vapor tight envelope. (2) Securement (a) Insulation shall be appliedto piping in accord ance with GENERAL SPECIFIC ATIONS I. B. 4,5,6 and 7. (b) All sectional pipe insulation having outside diameters of 6.625 inches or less shall be secured with stainless steel wire. (c) ALL pipe insulation having outside diameters greater than 6.625 inches shall be secured with stainless steel insulation strap. -5- n. SPECIFICATION 16-L B. APPLICATION - contd 2. Piping - contd b. Fittings, Flanges and Valve Covers (1) Fittings, flanges and valve covers shall be either factory moulded or prefabricated in accordance with UCCC Dimensional Standards Fabrication Manual. (2) Fittings, flanges and valve covers maybe field fabricated, provided work is approved by the Field Representative of the Department of Design and Construction. Segments shall be carefully fitted to insure tight joints. (3) Prefabricated covers shallbe secured with wire or strap as required. c. Steam Traced Installations Steam trace-lines, where specified, shallbe installed in accordance with the GENERAL SPECIFICATIONS I.B.15. d. Surface Finish. (1) Piping exposed to view or weather (a) Where present, cracks and depressions in vapor barrier jacket shall be filled with weather-barrier coating and trowelled smooth with adjacent surface prior to appli cation of weather-barrier coating finish. (b) Weather-barrier coating shall be applied over vapor barrier jacket in accordance with GENERAL SPECIFICATIONS I. B. 16. (2) Piping concealed Finish other than factory applied vapor barrier jackets will not be required. -6- CARBIDE AND CARBON CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 17-H Preformed Glass Fiber Scope w~ i; This specification describes the essential requirements for the purchase and the application of glass fiber insulation for use on ff Heating, Ventilating and Air Conditioning Ducts. sr Procedures outlined in the GENERAii SPECIFICATION are ! applicable to and constitute an integral part of this specification. A. MATERIAL i 1. Composition i Material shall be composed of fibrous glass with an in r organic resin binder formed into a rigid board and faced with a factory applied vapor barrier. 2. Properties i L Glass fiber insulation board and duct liner shall have the following properties: Alkalinity...........................................pH * 6 to 7 Capillarity...........................................Negligible after 24 hours. Combustibility....................................Will not support com bustion. Compressive Strength . . . Shall be not less than 0.07 @ 10% deflection ] Density..................................................6 to 7 lbs. per sq. ft. i Hygroscopicity....................................1.13% by wt. after 7 2 hours. I Resistance to Acids .... Good resistance except to Hydrofluoric and t Phosphoric. 1 II. SPECIFICATION I7-H A. MATERIAL - contd 2. Properties - contd Specific Gravity . Apparent0.012 to 0.016 true 2.6 Temperature Limits . 250F Thermal Conductivity Thermal Diffusivity . 3. Accessory Materials Shall not exceed values at the following mean temperatures: Mean Conductivity Temp.T. Btu/hr., sq. ft F, inch thick 0 0.21 100 0. 25 150 0. 28 250 0.35 0.32 sq. ft. per day a. Glass Fiber Insulation Board - Fiberglas FF VaporSeal Duct Insulation, Gustin-Bacon G--B Insulation Board with Foil-Scrim-Kraft Vapor Barrier, or ap proved alternate. b. Glass Fiber Duct Liner - Fiberglas Coated Duct In sulation, or approved alternate. c. Stainless Steel Wire - 0.0475 inch diameter, type 304 cold drawn, bright annealed, 18 gage. d. Fasteners - 1 - 1 /Z inches long, Stic-Klip Manufacturing Co., type N, Miracle Adhesives Anchor Nail, or ap proved alternate. e. Washers - Stic-Klip Manufacturing Co. Speed Washers, Miracle Adhesives Lock Washers, or approved alter nate. f. Lap and Strip Adhesive - Benjamin Foster 81-71, Minnesota Mining #1128, St. Clair Rubber Adhesive No. 4815, or approved alternate. - 2- II. SPECIFICATION 17-H A. MATERIAL - contd 3. Accessory Materials - contd g. Fastener Adhesive - Stic-Klip, type S, Miracle's Anchor adhesive type. AA, or approved alternate. h. Joint Sealer Strips - Foil with Kraft paper backing in three inch wide rolls. i. Reinforcing Cloth - Glass Fiber, approximately 10 x 10 thread count, with starch binder - Perma Glas Mesh, Benjamin Foster Open Weave, or approved alternate. j. Weather Barrier Coating, color as specified - Vimasco WC-1, Benjamin Foster Sealfas "C", or approved alternate. -3- II. SPECIFICATION 17-H B. APPLICATION 1. External Surfaces of Ductwork a. Thickness Schedule Insulation thickness shall be one inch. b. Duct Surfaces Insulation board shall be applied to external duct sur faces with all joints tightly butted. . c. Securement (1) Fasteners, as specified, shall be cemented to out side surfaces of duct on twelve inch staggered cen ters. On small ducts a minimum of two fasteners shall be cemented to each surface per linear foot. (2) Insulation shall be impaled on fasteners and se cured with washers that are installed so the insu lation is held firmly in place. (3) Fasteners shall be cut off l/l6 inch from outside of washer. d. Vapor Barrier All joints, cracks, and breaks, shall be sealed with three inch wide vapor barrier strips, cemented to existing vapor barrier to forma continuous vapor tight envelope. Where fastening devices project through insulation, holes shall be sealed with lap or strip ad hesive. e. Surface Finish (1) Ductwork exposed to view or weather. (a) Cracks and depressions shall be spotted with Weather Coating and trowelled smooth to form an even surface with insulation prior to ap plication of Weather Coating. -4- II. SPECIFICATION 17-H B. APPLICATION - contd 1. External Surfaces of Ductwork - contd e. Surface Finish - contd (1) Ductwork exposed to view or weather - contd (b) Weather Coating shall be applied over vapor barrier in accordance with GENERAL SPECI FICATION I.B. 16. (2) Ductwork concealed Finish other than factory attached vapor barrier will not be required. 2. Internal Surfaces of Ductwork Where specified, duct liner insulation shall be installed inside ducts in the following manner: a. Thickness Schedule Insulation thickness shall be one inch. b. Duct Surfaces Duct liner shall be applied to internal duct surfaces with all joints tightly butted. c. Securement (1) Fasteners shall be cemented to inside top surface of horizontal runs on twelve inch staggered cen ters. On small ducts a minimum of two fasteners per linear foot is required. (2) Duct liner shall be secured to top surface of hori zontal runs with mechanical fasteners. On all other surfaces duct liner shall be secured with adhesive. d. Surface Finish (1) All joints shall be pointed up with joint sealer. (2) Finish other than factory applied coating will not be required. -5- UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS H. SPECIFICATION 20-H Calcium Silicate Scope This specification describes the essential requirements for the purchase and the application of preformed calcium silicate in sulation for use on equipment and piping normally operating at temperatures from 70 F up to and including 750 F. Procedures outlined in the GENERAL SPECIFICATION, are applicable to and constitute an integral part of this Specification. A. MATERIAL 1. Composition Material shall be composed of hydrous calcium silicate blended with asbestos fibers in suitable proportion, with or without inorganic filler added. 2. Properties Calcium Silicate Insulation shall have the following prop erties: Absorptivity............................ Not more than 93% of volume after 24 hours submersion in water. Alkalinity................................... pH shall be not more than 11.0. Capillarity When placed on wet surface absorption after one-half hour shall be less than 100% and after 7 days less than 300% of its original weight. II. SPECIFICATION 20-H A. MATERIAL. -'contd 2. Properties - contd Combustibility....................................Shall be incombustible. Compressive Strength . . . Percent of deformation shall be less than listed below: Load Deformation lbs./feq. in. per cent 20 2 60 6 100 10 Density.................................... Flexural Strength . . . Shall be not less than 40 psi. Elasticity, Modulus of . . . Shall be not less than 35, 000 psi. Hygroscopicity. to 230 F, sample shall not gain overl0% by weight when exposed to air at 70 F, 90 RH for 14 days. Resistance to Abrasion . . . When placed in Rotap on twenty mesh a 3 x 3 x 1-1/2 sample shall not have lost more than 25% after 10 minute run, nor more than 40% after 20 minute run. Resistance to Acids or . . . It shall be resistant to Caustics most common caustics. (Not considered as an acid resistant material.) Specific Gravity . . 0. 15 to 1.28 Specific Heat .... - 1A - II. SPECIFICATION 20 -H A. MATERIAL - contd 2. Properties - contd Coefficient of Expansion . After being heated to 1200 F ' then cooled, expansion upon reheating shall not exceed 0.000004 per F. Coefficient of Shrinkage. . When heated from 70 F to 1200 F (not reheated) linear shrinkage shall be less than 2%. Temperature Limits . . . Shall be suitable for use from 0 F to 1200 F without mechanical, thermal, o r chemical failure. Tensile Strength . . Shall be above 6 lbs./sq. in. Thermal Conductivity- . Shall not exceed values at the following mean temper atures: Mean Temp. F Conductivity Btu/hr., sq. ft. F, inch Thick 100 200 300 400 500 600 700 800 0.43 0.46 0.49 0. 52 0. 58 0.64 0.69 0. 75 Thermal Diffusivity . . Shall not exceed 0. 3 5 sq. ft. per day. Thermal Shock Resistanc . Material shall not spall, chip or crack, or otherwise fail when heated to 1200 F and then quenched with water. -2 - H. SPECIFICATION 20-H A. MATERIAL - contd 3. Accessory Materials a. Calcium Silicate Insulation b. Wire - Stainless steel, .0475 inch diameter, type 304, cold drawn bright annealed, 18 gage. c. Insulation Strap - Stainless steel, l/2 inchx . 020 inches type 304 or approved alternate. d. Clips - Stainless steel, l/2 inch double pronged, type 304, A. J. Gerrard or approved alternate. e. Insulating Cement - Hydraulic setting, Baldwin-Hill Powerhouse, Eagle-Picher One Coat or approved alternate. f. Finishing Cement - Hard surface, Eagle-Picher No. 106, Johns-Manville 678 or approved alternate. g. Mineral Wool Blanket - Black, Spun Rock Wool, Hex agonal Wire Netting on both faces. h. Mineral Wool Blanket - Black, Spun Rock Wool, Hex Netting one side, Expanded Metal Lath on the other side. i. Heat Resistant Sealer - Benjamin Foster No. 30-43 or approved alternate. j. Weather-Barrier Coating (Color as Specified) - Vimasco WC-1, Benjamin Foster Sealfas "C". k. Reinforcing Cloth - Glass Fiber, 10 x 10 thread count, Perma Glass Mesh, Glasfab or approved alternate. l. Fabricating Cement-A. P. Green "Insulation Adhesive" or approved alternate. m. Wire Netting - One inch. Hexagonal Mesh, No. 20 gage, stainless steel, type 304, or approved alternate. -3 - i * t- i r II. SPECIFICATION 20-H B. APPLICATION 1. Equipment a. Insulation Supports Equipment shall be provided with insulation supports as called for in the GENERAL SPECIFICATIONS, I.B.4. b. Thickness Schedule Unless otherwise specified, insulation in excess of two and one-half inches total thickness shall be applied in multi-layer construction as specified in GENERAL SPECIFICATION, I.B.l. c. Curved Surfaces On all equipment, insulation block shall be properly miter cut to fit vessel surface and applied to vessel sides and heads in staggered position, with all joints tightly butted. Block shall be applied to vessel sides with linear dimension paralleling axis of vessel. Typical installation is shown in Figure 20-H-l. L 3 m1 i application of calcium silicate insulation to vessel FIOJM 10-N-I I -4- II. SPECIFICATION 20-H B. APPLICATION - contd 1. Equipment - contd d. Flat Surfaces (1) Block insulation shall be applied to flat surfaces in staggered position with all joints tightly butted. It shall be securedwith wire attachedto blank nuts or other approved securement. On rectangular equipment, the blank nuts, or other approved securements, shall be placed on 12-inch centers, staggered, for bottom surfaces and on 24-inch centers, staggered for side and top surfaces . Where specified in the Insulation Design Schedule, block may be applied to flat surfaces with an ap proved adhesive. (2) When specified thickness of insulation has been applied, reinforcing netting shall be stretched tightly over block and secured with tie wires or other approved securement. Entire surface shall be given a l/2 inch thick, smooth and uniformly applied trowel coat of hydraulic setting insulating cement. Typical installation is shown in Figure20-H-2. -5- I f II. SPECIFICATION 20-H B. APPLICATION - contd . l L Equipment - contd f e. Securement (1) All layers of insulation shall be secured with in 1 sulation strap where contour of vessel permits 1 firm and effective attachment. Insulation applied to irregular surfaces, where strap is imprac f ticable, shall be secured with wire, drawn taut, ;l ends twisted and embedded in insulation. T (2) All layers of insulation on bottom heads of vertical equipment and heads of horizontal equipment shall ! be secured in place with wire attached to blank nuts, or with insulation strap attached to insula 1 tion support, as specified in UCCC Standard 1 IS-31 and Figure 20-H-3. > \ i J I 1. ! -6 - II. SPECIFICATION 20-H B. APPLICATION contd 1. Equipment - contd f. Expansion Joints Expansion joints in flat surfaces or cylindrical vessels shall be insulated with flexible blanket insulation. Typical installation is shown in Figure 20-H-4. MINIMAL WOOL ilANKET OP SPECIFIED THICKNESS FACEO OUTSIDE WITH EXPANOCO MeTAL LATH ANO ON THE INSlOC WITH HEX WINE NETTING. THICKNESS T, AS SPECIFIED FINISH AS SPEClFICO THICKNESS T, AS SPECIFIED '* SLANK NUTS ON 0TWEIT APPNOVE0 SECUNCMENT ON K CINTCNS 1TAENE0 NOTE: VOI0S ON EXPANOCO METAL LATH TO SE PILLCO WITH HTONAULiC SETTINS CEMENT TNOWELEO PLUSH WITH 3UHPACE OP LATH APPLICATION OF BLANKET INSULATION TO EXPANSION JOINTS ON FLAT SURFACE PIS. fO-N-4 II. SPECIFICATION 20-H B. APPLICATION - contd 1. Equipment - contd g. Corrugated mechanical expansion joints on piping (usually listed as equipment item) shall be insulated as shown in Figure 20-H-5. NO. 28 GA. SHEET METAL JACKET FITTED APPLICATION OF CALCIUM SILICATE INSULATION TO EXPANSION JOINTS FIG. 20--M-S -8 - II. SPECIFICATION 20-H B. APPLICATION - contd 1. Equipment - contd h. Insulated Vessel Flanges Vessel flanges shall be insulated with block in the same manner as specified for body of vessel. An insulation support shall be provided immediately above vessel flange. The top of projecting flange insulation shall be sloped to shed water. Typical installation is shown in Figure 20-H-6. -9 - II. SPECIFICATION ZO-H B. APPLICATION - contd 1. Equipment - contd i. Uninsulated Vessel Flanges Where vessel flanges are located outdoors and speci fied to be left uninsulated, the reinforcing cloth of the weather-barrier, on the adjacent vessel insulation, shall be extended to metal of vessel body, embedded in heat resistant sealer, and banded while sealer is still tacky. A second application of heat resistant sealer shall then be applied over the reinforcing cloth and securement. Typical installation is shown in Fig ure 20-H-7. 10 II. SPECIFICATION 20-H B. APPLICATION - contd 1, Equipment - contd j. Vessel Nozzles Vessel nozzles shall be insulated as shown in Figure 20-H-8. INSULATION BITE* CUT ANO PITTED 0IMENSION3 SMALL BE IN UNg N022Lg BUND NOZZLE APPLICATION OF CALCIUM SILICATE TO VESSEL NOZZLES flOURt 20-M-B II. SPECIFICATION 20-H B. APPLICATION - contd 1. Equipment - contd k. Vessel Legs (1) Vessel legs shall be insulated with block which shall extend over channel flanges and down channel legs to fireproofing. Thickness shall be a mini mum of one-half that specified for body of vessel. (2) Vessel insulation shall be butted firmly against tank leg flange. Re-entrant space between channel flanges and over channel flanges between body in sulation shall be filled with block. Installation shall be as shown in Figure 20-H-9. 12 II. SPECIFICATION 20-H B. APPLICATION - contd 1. Equipment - contd 1. Vessel Skirts Skirts supporting vertical equipment shall have their outer surfaces insulated. Unless otherwise specified, insulation shall extend downward, from junction of skirt with bottom head, a minimum of four times the speci fied thickness, but not less than twelve inches, or to bottom of skirt if that distance is less than twelve inches. Thickness shall be as specified for body of vessel. The bottom head insulation shall be supported in accordance with UCCC Standard IS-42. Installation shall be as shown in Figure 20-H-10. APPLICATION OF CALCIUM SILICATE INSULATION TO VESSEL SKIRT fICURe 2O-H-I0 13 II. SPECIFICATION 20-H B. APPLICATION - contd 1. Equipment - contd m. Surface Finish When specified thickness of insulation has been ap plied, any small cracks or depressions shallbe point ed up with insulation cement trowelled flush with sur face of insulation. n. Weather-Barrier Weather-barrier shallbe installedin accordance with the GENERAL SPECIFICATIONS, I.B. 16. 2. Piping a. Pipe Insulation (1) Thickness Schedule Unless otherwise specified, insulation in excess oftwo and one-half inches total thickness shallbe applied in multi-layer construction as specified in GENERAL SPECIFICATION, I. B. 1. (2) Securement (a) Insulation shallbe appliedto piping in accord ance with GENERAL SPECIFICATIONS, I.B. 4,5,6, and 7. (b) All inner layers of sectional pipe insulation shall be secured with stainless steel wire. (c) All sectional pipe insulation having outside diameters of 6.625 inches or less shallbe secured with stainless steel wire. (d) All pipe insulation having outside diameters greater than 6.625 inches shallbe secured with stainless steel insulation strap. II. SPECIFICATION 20 -H B. APPLICATION - contd 2. Piping - contd b. Fittings, Flanges and Valves - contd (3) Insulating cement may be applied as the insulating material where fittings are 2-1 [Z inch IPS or smaller and the specified insulation thickness does not exceed 1-1/2 inches. Cement shall be of same thickness as specified for adjacent pipe in sulation. (4) Fitting insulation shall be secured with specified wire or strap as required. (5) Insulation for all fittings shall be fitted and assem bled with tight joints. Cementing of shop fabri cated assemblies shall be done with specified fabricating cement. In all cases the joints shall be as thin as possible, with just sufficient cement to obtain good adhesion and complete closure. In no case will wide cement joints, or voids, and holes filled with fabricating cement, be permitted. Typical installations are shown in Figures 20-H-l 1, 20-H-12, and 20-H-13. 63 i APPLICATION OF CALCIUM SILICATE INSULATION TO WELDING ELL Fl. 20-H-H 15 - II. SPECIFICATION 20-H B. APPLICATION - contd 2. Piping - contd b. Fittings, Flanges and Valves - contd APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO LINE FLANGE FIG. 20- M - 12 APPLICATION OF CALCIUM SILICATE INSULATION TO FLANGED VALVE rifl. 20-M- 13 - 16 II. SPECIFICATION 20-H B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers (1) Fittings, flanges and valves shall be insulated with prefabricatedfitting covers (preferredmeth od) in accordance with UCCC Dimensional Stand ards Fabrication Manual. (2) Fitting, flange and valve covers may be field fabricated provided work is in accordance with and/or approved by the Field Representative of the Department of Design and Construction. Segments shall be carefully fitted to insure tight joints. c. Steam Traced Installations Steam-trace lines, where specified, shall be installed and insulated in accordance with the GENERAL SPEC IFICATION, I. B. 15. d. Surface Finish Where present, small cracks and depressions shall be filled and smoothed with insulating cement prior to application of weather-barrier. e. Weather-Barrier Weather-barrier shall be installed in accordance with GENERAL SPECIFICATIONS, I.B. 16. -17- UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 21-H Asbestos Fiber Scope This specification covers the application of preformed asbestos fiber insulation for use on piping normally operating at tempera tures from 70 F up to and including 750 F. Procedures outlined in the GENERAL SPECIFICATION, are applicable to and constitute an integral part of this specification. A. MATERIAL 1. Composition Material shall be composed of asbestos fibers blended with suitable inorganic binder, processed and molded at sufficient temperatures to produce a rigid, homogeneous thermal insulation. 2. Properties Asbestos Fiber Insulation shall have the following properties: Absorptivity......................................... Not over 85% of volume after 24 hours submer sion. Alkalinity pH shall be not more than 10. 7 Coefficient of Expansion, (or Volume and Linear Shrinkage) . Shrinkage shall be less than 0. 7% when heated to 750 F Combustibility . . . Shall be incombustible II. SPECIFICATION 21-H A. MATERIAL - contd 2. Properties - contd Compressive Strength . Compression of the 1 in. block shall be not more than the following: Lbs./sq.in. Compression 5 .07" 10 . 15" 20 .30" 40 .55" Density Shall be not less than 12 but not more than 16 lbs. per cu. ft. Flexural Strength............................. Shall be not less than 100 lbs. per sq. in. Hygroscopicity...................................... Weight gain of oven dried sample subjected to 70 F and 90 RH for the expo sure times listed, shall be not more than the corresponding percentages. Days 1 7 14 30 Percentages 4 15 19 23 Specific Gravity............................ Shall be approximately 0. 228 Specific Heat................................... Shall be approximately 0.248 Btu/lb. Thermal Conductivity MeanTemp F Btu/S.F. in. thk. 200 400 600 0.40 0.51 0.62 II. SPECIFICATION Zl-H B. APPLICATION - contd 1. Piping - contd d. Expansion Joints (l) Expansion slip joints shall be provided in the in sulation for multiple layer a p p 1 i c a t i o n s. An expansion joint shall be installed in each 21'-0" of straight piping not interrupted by flanges, valves or fittings. Typical installation is shown in Fig ure 21-H-5. note: expansion joint shall it installed oIN EACH Zl'-O* or STKAIGKT PtPfNS.NOT INTEN- nupte rr glances, valves oh rrrriNOs. pom VERTICAL PIPINO. EXPANSION JOINT SMALL SC INSTALLED AT INSULATION SUPPONT*. EXPANSION JOINT FOR MULTIPLE LAYER APPLICATION OF ASBESTOS FIBER INSULATION PIS. zt s (2) The expansion slip joints shall be installed at the insulation support in vertical piping. Care shall be exercised that slip joint is placed so movement occurs at the bottom in order to shed water. -8 - II. SPECIFICATION 21-H B. APPLICATION - contd L Piping - contd d. Expansion Joints - contd (3) Expansion slip joints shall be provided at junction of fitting covers and pipe insulation located at the top of risers, where riser exceeds 30'-0" inheight for single layer applications and where riser ex ceeds 15'-0" in height for multiple layer applica tions. Typical installation is shown in Figure 21-H-6. *OTC: Sit* JOINT SHAH sc '"OVIOCD FO* SIM61C live* APPLICATIONS mc*c use* exceeos >o`-o* in H10NT A NO VO* MULTIPLE live* is' -o*application* mnc*c *ne* etcecot APPLICATION OF MULTIPLE LAYER ASBESTOS FI8ER INSULATION TO WEL01NG ELL 4*i. 2 I-- H- II. SPECIFICATION 21-H B. APPLICATION - contd 1. Piping - contd d. Expansion Joints - contd (4) Corrugated mechanical expansion joints in piping (usually listed as equipment item) shall be in sulated as shown in Figure 21-H-7. APPLICATION OF ASBESTOS FIBER INSULATION TO EXPANSION JOINTS n. 21-H-r e. Steam Traced Installations Steam-trace lines, where specified shall be installed and insulated in accordance with the GENERAL SPECI FICATION, I. B. 15. f. Weather-Barrier Weather-barrier shall be installed in accordance with GENERAL SPECIFICATION, LB. 16. 10 CARBIDE AND CARBON CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 25-H Hydrous Calcium Silicate Scope This specification describes the essential requirements for the purchase and the application of preformed calcium silicate in sulation for use on equipment and piping normally operating at temperatures from 750 F up to and including 1200 F. Procedures outlined in the GENERAL SPECIFICATION, are applicable to and constitute an integral part of this Specification. A. MATERIAL 1. Composition Material shall be composed of hydrous calcium silicate blended with asbestos fibers in suitable proportion, with or without inorganic filler added. 2. Properties Calcium Silicate Insulation shall have the following prop erties: Absorptivity............................Not more than 93% of volume after 24 hours submersion in water. Alkalinity...................................pH shall be not more than 10. 0 Capillarity...................................When placed on wet surface absorption after one-half hour shall be less than 100% and after 7 days less than 300% of its original weight. II. SPECIFICATION 25-H . A. MATERIAL - contd 2. Properties - contd Combustibility............................ . Shall be incombustible. Compressive Strength . . Percent of deformation shall be less than listed below: Load Deformation lbs.^q. in. per cent 20 2 60 6 100 10 Density........................................... . 10 to 14 lbs./cu. ft. Flexural Strength . . Shall be not less than40 psi. Elasticity, Modulus of . . . Shall be not less than 35, 000 psi. Hygrscopicity............................ . After oven dried at 200F to 230F, sample shall not gain over 10% by weight when exposed to air at 70 F, 90 RH for 14 days. Resistance to Abrasion . . When placed in Rotap on twenty mesh a 3 x 3 x 1-1/2 sample shall not have lost more than 25 % after 10 minute run, nor more than 40% after .20 minute run. Resistance to Acids or . Caustics Specific Gravity . . It shall be resistant to most common caustics. (Not considered as an acid resistant material.) . 0. 15 to 0. 28 Specific Heat............................ . 0. 20 to 0.30 Btu/lb. F. 1A - II. SPECIFICATION 25-H A. MATERIAL - contd 2. Properties - contd Coefficient of Expansion After being heated to 1800 F then cooled, expansion upon reheating shall not exceed 0.000004 per F. Coefficient of Shrinkage. When heated from 70 F to 1800 F (not reheated) linear shrinkage shall be less than 2%. Temperature Limits . Shall be suitable for use from 0 F to 1800 F without mechanical, thermal, or chemical failure. Modulus of Rupture . Shall be above 50 psi Thermal Conductivity Thermal Diffusivity . Shall not exceed values at the following mean temper atures: Mean Temp.F Conductivity Btu/hr ..sq.ft.,. F, inch thk. 100 400 800 1200 0.43 0.58 0.78 1.09 Shall not exc eed 0. 3 5 sq. ft. Thermal Shock Resistance . Material shall not spall, chip or crack, or otherwise fail when heated to 1800 F and then quenched with water. -2- II. SPECIFICATION 25-H A. MATERIAL - contd 3. Accessory Materials a. Hydrous Calcium Silicate Insulation - KayloNo. 20 or approved alternate. b. Wire - Stainless steel, .0475 inch diameter, type 304, cold drawn bright annealed, 18 gage. c. Insulation Strap - Stainless steel, l/2 inchx . 020 inches type 304 or approved alternate. d. Clips - Stainless Steel, 1/2 inch double pronged, type 304, A. J. Gerrard or approved alternate. e. Insulating Cement - Hydraulic setting, Baldwin-Hill Powerhouse, Eagle-Picher One Coat or approved alternate. f. Mineral Wool Blanket - Black, Spun Rock Wool, Hex Netting one side, Expanded Metal Lath on the other side. g. Mineral Wool Blanket - Black, Spun Rock Wool, Hex agonal Wire Netting on both faces. h. Heat Resistant Sealer - Benjamin Foster No. 30-43 or approved alternate. i. Weather-Barrier Coating (Color as Specified) - Vimasco WC-1, Benjamin Foster Sealfas "C". j. Reinforcing Cloth - Glass Fiber, 10 x 10 thread count, Perma Glass Mesh, Glasfab or approved alternate. k. Fabricating Cement - A. P. Green "Insulation Adhesive" 1. Wire Netting - One inch, Hexagonal Mesh, No. 20 gage. Stainless Steel, Type 304, or approvedalternate. -3 - II. SPECIFICATION 25-H B. APPLICATION 1. Equipment a. Insulation Supports Equipment shall be provided with insulation supports as called for in the GENERAL SPECIFICATIONS, I.B.4. b. Thickness Schedule Unless otherwise specified, insulation in excess of two and one-half inches total thickness shall be applied in multi-layer construction as specified in GENERAL SPECIFICATION, I.B.l. c. Curved Surfaces On all equipment, insulation block shall be properly miter cut to fit vessel surface and applied to vessel sides and heads in staggered position, with all joints tightly butted. Block shall be applied to vessel sides with linear dimension paralleling axis of vessel. Typical installation is shown in Figure 25-H-l. APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO VESSEL f 10. ZS - H. I -4 - II. SPECIFICATION 25-H B. APPLICATION - contd 1. Equipment - contd d. Flat Surfaces (1) Block insulation shall be applied to flat surfaces in staggered position with all joints tightly butted. It shall be securedwith wire attached toblanknuts or other approved securement. On rectangular equipment, the blank nuts, or other approved securements, shall be placed on 12-inch centers, staggered, for bottom surfaces and on 24-inch centers, staggered for side and top surfaces. (2) When specified thickness of insulation has been applied, reinforcing netting shall be stretched tightly over block and secured with tie wires or other approved securement. Entire surface shall be given a l/2 inch thick, smooth and uniformly appliedtrowel coat of hydraulic setting insulating cement. Typical installation is shown in Figure 25-H-2 lV 8LANK NUTS OR OTHER APPROVED SECUREMENTS LOCATED OH 12* CENTERS STAGGEREO,FOR DOTTO* SURFACES AND 24 CENTERS STAGGERED FOR 30C AND TOP SURFACES APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO FLAT SURFACE FIO. tS - H- Z -5- II. SPECIFICATION 25-H B. APPLICATION - contd 1. Equipment - contd e. Securement (1) All layers of insulation shall be secured with in sulation strap where contour of vessel permits firm and effective attachment. Insulation applied to irregular surfaces, where strap is imprac ticable, shall be secured with wire, drawn taut, ends twisted and embedded in insulation. (2) All layers of insulation on bottom heads of vertical equipment and heads of horizontal equipment shall be secured in place with wire attached to blank nuts, or with insulation strap attached to insula tion support, as specified in C &C C C Standard IS-31 and Figure 25-H-3. SECUREMENT OF HYDROUS CALCIUM SILICATE INSULATION ON VESSEL HEAD FIG. 23 - M 3 II. SPECIFICATION 25-H B. APPLICATION - contd I. Equipment - contd f. Expansion Joints (1) Expansion joints in flat surfaces or cylindrical vessels shall be insulated with flexible blanket in sulation. Typical installation is shown in Figure 25-H-4. MINERAL WOOL BLANKET OF SPECIFIED THICKNESS FACED OUTSIDE WITH EXPANOED METAL LATH ANO ON THE INSIDE WITH T HEX WIRE NETTING------------- EXPANOED METAL LATH EXPANOED OVER BLOCK A MINIMUM OF 6* ANO SECUREO WITH TIE WIRES INSULATION 'V BLANK NUTS OR OTHER APPROVEO SECUREMENT ON 12* CENTERS STAGGERED THICKNESS T, AS SPECIFIED THICKNESS T, AS SPECIFIED NOTE: VOtOS OF EXPANOED METAL LATH TO BE FILLEO WITH HYORAULIC SETTING !^?aU>^riNG CEMENT TROWELEO FLUSH WITH SURFACE OF LATH. APPLICATION OF BLANKET INSULATION TO EXPANSION JOINTS ON FLAT SURFACE FIG. ZS - M - 4 -7- II. SPECIFICATION 25-H B. APPLICATION - contd 1. Equipment - contd f. Expansion Joints - contd (2) Corrugated mechanical expansion joints on piping (usually listed as equipment item) shall be insula ted as shown in Figure 25-H-5. NO 26 84. SHEET METAL JACKET PITTED OVER EXPANSION JOINTS AND EXTENDED APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO EXPANSION JOINTS PIG. 23 - H - 5 -8 - II. SPECIFICATION 25-H B. APPLICATION - contd 1. Equipment - contd g. Insulated Vessel Flanges Vessel flanges shall be insulated with block in the same manner as specified for body of vessel. An insulation support shall be provided immediately above vessel flange. The top of projecting flange insulation shall be sloped to shed water. Typical installation is shown in Figure 25-H-6. -9 - II. SPECIFICATION 25-H B APPLICATION - contd I. Equipment - contd lx. Vessel Nozzles Vessel nozzles shall be insulated as shown in Figure 25-H-7. INSULATION MITER CUT ANO FITTED DIMENSIONS SHALL BE IN ACCORDANCE WITH FABRICATION OATA FOR FITTING LINE NOZZLE 9LIN0 NOZZLE APPLICATION OF HYDROUS CALCIUM SILICATE TO VESSEL NOZZLES FIG 25 - H . 7 10 - II. SPECIFICATION 25-H B. APPLICATION - contd 1. Equipment - contd i. Vessel Legs (1) Vessel legs shall be insulated with block which shall extend over channel flanges and down channel legs to fireproofing. Thickness shall be a mini mum of one-half that specified for body of vessel. (2) Vessel insulation shall be butted firmly against tank leg flange. Re-entrant space between channel flanges and over channel flanges between body in sulation shall be filled with block. Installation shall be as shown in Figure 25-H-8. - 11 II. SPECIFICATION 25-H B. APPLICATION - contd 1. Equipment - contd j.. Vessel Skirts Skirts supporting vertical equipment shall have their outer surfaces insulated. Unless otherwise specified, insulation shall extend downward, from junction of skirt with bottom head, a minimum of four times the speci fied thickness, but not less than twelve inches, or to bottom of skirt, if that distance is less thantwel\e inches. Thickness shall be as specified for body of vessel. The bottom head insulation shall be supported in accordance with C&CCC Standard IS-42. Installation shall be as shown in Figure 25-H-9. BOTTOM HE AO INSULATION secureo with tie wires ATTACHE0 TO SPLIT RING SUPPORT AS PER C SC C C STO. 1 S - 42 INSIOE OP SKIRT NOT INSU LATED UNLESS SPECIFICALLY NOTED. APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO VESSEL SKIRT FIG. 23 - H - 9 II. SPECIFICATION 25-H B. APPLICATION - contd 1. Equipment - contd k Surface Finish When specified thickness of insulation has been applied, any small cracks or depressions shall be pointed up with insulating cement, troweled flush with surface of insulation. 1. Weather-Barrier Weather-barrier shall be installed in accordance with the GENERAL SPECIFICATIONS, I.B. 19. 2. Piping a. Pipe Insulation (1) Insulation shall be applied to piping in accordance with GENERAL SPECIFICATIONS, I.B. 4, 5, 6, and 7. (2) Unless otherwise specified, insulation in excess of two and one-half inches total thickness shall be applied in multi-layer construction as specified in GENERAL SPECIFICATION, I. B.l. b. Fittings, Flanges and Valves (1) Fittings, flanges and valves shall be insulated with prefabricated fitting covers (preferred method) in accordance with C&CCC Dimensional Standards Fabrication Manual. (2) Fitting, flange and valve cover s may be field fabri cated providedwork is in accordance with and/or approved by the Field Representative of the Depart ment of Design and Construction. Segments shall be carefully fitted to insure tight joints. 13 j T II. SPECIFICATION 25-H T B. APPLICATION - contd if 2. Piping - contd r b. Fittings, Flanges and Valves - contd (3) Insulation for all fittings shall be fitted and assem r bled with tight joints. Cementing of shop fabri cated assemblies shall be done with specified fabricating cement. In all cases the joints shall be as thin as possible, with just sufficient cement to obtain good adhesion and complete closure. In < no case will wide cement joints, or voids, and i holes filled with fabricating cement, be permitted.. Typical installations are shown in Figures 25-H-10, 25-H-ll, 25-H-12, and 25-H-13. i I i ;/ 1 i `J. 1 L r APPLICATION OF HYQRQUS CALCIUM SILICATE INSULATION TO WELDING ELL I f IG. 23 M JO I. L L 14 - II. SPECIFICATION 25-H B. APPLICATION - contd 2. Piping - contd b. Fittings, Flanges and Valves - contd NOTE: FLANGE COVER FABRICATED IN ACCORDANCE WITH DIMENSIONAL STANDARD FABRICATION DATA. APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO LINE FLANGE FIG. 25- M. || APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO FLANGED ELL FIG 25 - M - l 2 15 II. SPECIFICATION 25-H B. APPLICATION - contd 2. Piping - contd b. Fittings, Flanges and Valves - contd (4) Fitting insulation shall be secured with specified wire or strap as required. c. Steam Traced Installations Steam-trace lines, where specified, shall be installed and insulated in accordance with the GENERAL SPECI FICATION, I.B. 15. d. Surface Finish Where present, small cracks and depressions shall be filled and smoothed with insulating cement prior to application of weather-barrier. 16 - I II. SPECIFICATION 25-H B. APPLICATION - contd 2. Piping - contd e. Weather-Barrier Weather-barrier shall be installed in accordance with GENERAL SPECIFICATION, I.B.19. 17 - UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS SPECIFICATION 3 1-H Prefabricated Aluminum Scope This specification covers the application of prefabricated alumi num insulation for use on equipment and piping normally operating at temperatures from 32 F up to and including 1000 F. It is applicable to both indoor and outdoor service. Procedures outlined in the GENERAL SPECIFICATION, are appli cable to and constitute an integral part of this Specification. A. MATERIAL 1. Composition Insulation shall consist of prefabricated units comprised, in general, of a rigid outer aluminum shell, enclosing aluminum sheets properly spaced and reinforced with supports (separators). Supports shall be designed and fabricated of a material, having low heat transmission and a moisture absorptivity not to exceed 1% after 24 hours, to form isolated air chambers. Units shall be equipped with means for securement. 2. Properties a. Properties shall be as listed in the following table: Emmisivity...................................Shall be approx. 0.03 Reflectivity...................................Shall be approx. 95% Temperature Limits . . . Shall be suitable for use from plus 33 F up to and including plus 1000 F without deterioration or cracking of parts. II. SPECIFICATION 31-H A. MATERIAL - contd 2. Properties - contd b. Form Prefabricated aluminum insulation shall be furnished in units, which can be easily handled, in the following forms: (1) Sectional Pipe Insulation (a) Sectional pipe insulation, composed primarily of aluminum inner sheets of No. 34 B & S Gage (Minimum thickness) and aluminum outer shell of No. 20 B & S Gage (Minimum thick ness). (b) Pipe insulation shall be made in two unit sec tions. One circumferential edge of each unit and the longitudinal edges of one half section shall be extended to provide overlap and water shed. Joints of units shall be fabricated to form effective thermal insulation. (c) Longitudinal edges of inner sheets shall be bent inward sufficiently to provide reinforce ment and a tight joint with opposing sheets upon closure. (d) Sectional pipe insulation shall be furnished with metal bands (preferred) or other fasten ing devices where authorized. (2) Fitting, flange and valve covers shall be prefabri cated, and of the same general composition and construction as sectional pipe insulation. (3) Panel sections, both flat and curved, shall be pre fabricated of same general composition and con struction as sectional pipe insulation. Minimum thickness for inner sheets shall be No. 34 B & S Gage and No. 18 B & S Gage for outer shell. -2 - II. SPECIFICATION 31-H A. MATERIAL - contd 2. Properties - contd b. Form - contd (4) Quick removable units for piping and/or equipment shall be prefabricated and of the same general composition and construction as sectional pipe in sulation except that the minimum thickness for outer shell shallbe No. 16 B & S gage. These units shall be of heavy-duty construction and designed so as to be easily removed and reinstalled. Where requiredto facilitate quick removal, special latches shall be provided for securement. (5) Units shall be provided withcut-outs for supports, nozzles and other projections where required. (6) The number of reflective surfaces and the spacing of the reflective sheets shall be as designated by the Department of Design and Construction. 3. Accessory Materials a. Prefabricated Aluminum - Mirror Insulation or ap proved alternate. .. . :n b.. Stainless Steel Insulation Strap - 3/8 inch x . 015, Type .aa304 or approved alternate. c c. Aluminum Clips - Double pronged, A. J. Gerrard or approved alternate. d. Aluminum Sheet Metal Screws (Minimum Size No. 12) e. Caulking Mastic - Suitable for temperature to which it will be subjected. ............. .... f. Aluminum Pressure Sensitive Sealing Tape - Suitable for temperature to which it will be subjected. II. SPECIFICATION 31-H B. APPLICATION 1. Equipment a. Supports Equipment shall be provided with insulation supports as specified in the GENERAL SPECIFICATIONS. b. Thickness Schedule Unless otherwise specified, insulation shall be applied in one layer. c. Curved Surfaces Panels fabricated for curved surfaces shall be applied with edges closely abutting and with outer casing laps, or trim strips, arranged to shed water. Panels shallbe secured to each other with sheet metal screws through the casing laps, or trim strips, over joints to form a continuous envelope over the surface to be in sulated, except at expansion joints, flanges, etc. Where required, panels shall be secured with insulation strap or special fasteners. d. Flat Surfaces Panels fabricated for flat surfaces shall be applied in the same manner as specified for curved surfaces. Where the span of surface to be insulated exceeds 30", panels shall be secured to the surface by a method approved by owner. 2. Piping a. Pipe Insulation (1) Insulation supports, where required, shallbe pro vided by the Contractor. (2) Unless otherwise specified, insulation shall be applied in one layer. -4 - II. SPECIFICATION 31-H B. APPLICATION - contd 2. Piping - contd a. Pipe Insulation - contd (3) Insulation shall be applied to piping with the flush separator end of each section inserted into over lapping end of abutting sections. The extended longitudinal edges of each section shall be lapped over flush edges of opposing half-section so that all joints are tightly abutted. (4) Lapped edges of outer shell shall be placed so as to shed water. b. Fitting, Flange, Valve and Pipe Bend Covers Fittings, flanges, valves and bent piping shall be in sulated in a manner similar to that for straight piping. The fitting covers shall be applied with telescoping joint connections to the adjacent pipe insulation. In cases where the covers adjoin other types of insulation, the covers shall be designed to overlap the dissimilar insulation. c. Securement Insulation shall be secured in place with insulation strap, or screws, furnished by the manufacturer, as specified in the Accessory Materials Section of this Specification. d. General (1) Care shall be taken in the application to prevent crushing or other abuse of the insulation, and to preserve the factory finish of the outer shell. (2) Where any field cutting or fitting around supports or nozzles is required, care shall be exercised to insure good workmanship, and to seal the individual air chambers in the insulation. -5- H. SPECIFICATION 31-H B. APPLICATION - contd 2. Piping - contd d. General - contd (3) Where equipment or piping is located outdoors, or where otherwise required, joints or openings in outer shell of the insulation shall be caulked or flashed to form a watershed. Where caulking mastic is impractical to use for sealing joints or openings, as in the case of removable units, alumi num tape, as specified, shall be used. (4) Provision shall be made in the assembly of the in sulation units, to allow for expansion and contrac tion of the surfaces insulated, without damage to the insulation. (5) Steam-trace lines, where specified, shall be in stalled and insulated in accordance with the GENERAL SPECIFICATION, I. B. 15. -6 - UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 32-H Hydrous Calcium Silicate Scope This specification describes the essential requirements for the purchase and application of.preformed hydrous calcium silicate insulation for use on equipment and piping, operating above 70 F, specified to be protected from fire exposure. Procedures outlined in the GENERAL SPECIFICATION are appli cable to and constitute an integral part of this Specification, with exceptions as noted herein. A. MATERIAL 1. Composition Material shall be composed of hydrous calcium silicate blended with asbestos fibers in suitable proportion, with or without inorganic filler added. 2. Properties Hydrous calcium silicate insulation shallhave the follow ing properties: Absorptivity....................................Not more than 93% of vol ume after 24 hours sub mersion in wafer. Alkalinity............................................. pH shall be not more than 10. 0 Capillarity............................................. When placed on wet sur face absorption after one half hour shall be less than 100%andafter seven days less than 30% of its original weight. 1 II. SPECIFICATION 32-H A; MATERIAL - contd 2. Properties - contd Combustibility..... . Shall be incombustible. Compressive Strength . . Percent of deformation shall be less than listed below: Load Deformation lbs./sq.in. per cent 20 2 60 6 100 10 Density.......................................... . 10 to 14 lbs./cu. ft. Flexural Strength .... . Shall be not less than-40 psi. Elasticity, Modulus of . . Shall be not less than 35, 000 psi. Hygroscopicity............................ . After oven dried at 200F to 230F, sample shall not gain over 10% by weight when exposed to air at 70 F, 90 RH for 14 days. Resistance to Abrasion . . When placed in Rotap on twenty mesh a 3 x 3 x 1-1/2 sample shall not have lost more than 25% after 10 minute run, nor more than 40% after 20 minute run. Resistance to Acids or . Caustics . It shall be resistant to most common caustics. (Not considered as an acid resistant material.) Specific Gravity .... . 0. 15 to 0.28 Specific Heat........................... - 1A - II. SPECIFICATION 32-H A. MATERIAL - contd 2. Properties - contd Coefficient of Expansion After beingheatedto 1800F, then cooled, expansion upon reheating shall not exceed .000004 per F. Coefficient of Shrinkage . When heated from 70 "F to 1800F(not reheated) linear shrinkage shall be less than 2%. Temperature Limits . Shall be suitable for use fromO'F tol800F without mechanical, thermal or chemical failure. Modulus of Rupture . Shall be above 50 psi Thermal Conductivity Shall not exceed values at the following mean temper atures: Mean Conductivity Temp. F Btu/hr. , Sq. Ft. , F, inch Thick 100 0.43 400 0.48 800 0. 78 1200 1.09 Thermal Diffusivity . Shall not exceed 0. 325 sq. ft. per day. Thermal Shock Resistance . Material shall not spall, chip or crack, or otherwise fail when heatedto 1800F and then quenched with water. 3. Accessory Materials a. Hydrous Calcium Silicate Insulation - Kaylo No. 20 or approved alternate. -2 - II. SPECIFICATION 32-H A. Material - contd 3. Accessory Materials - contd b. Wire - Stainless steel, 0.0475 inch diameter, type 304 cold drawn bright annealed 18 gage. c. Insulation Strap - Stainless steel, l/2 inch x 0.020 inch, type 304 or approved alternate. d. Clips - Stainless steel, l/2 inch double pronged, type 304, A. J. Gerrard or approved alternate. e. Heat Resistant Sealer - Benjamin Foster No. 30-43 or approved alternate. . Weather-Barrier Coating (Color as Specified)-Vimasco WC-1, Benjamin Foster Sealfas "C" or approved alter nate. g. Reinforcing Cloth - Glass Fiber, 10 x 10 thread count, Perma Glass Mesh, Glasfab or approved alternate. h. Fabricating Cement - Franset Refractory Cement, or approved alternate. i. Wire Netting - One inch, hexagonal mesh. No. 20 gage, stainless steel or monel. j. Insulating Cement - Hydraulic setting, Baldwin-Hill Powerhouse, Eagle Picher one coat or approved alter nate. k. Mineral Wool Blanket - Black, spun rock wo 1, hex netting one side, expanded metal lath on the other side. -3 - II. SPECIFICATION 32-H B. APPLICATION - contd 1. Equipment - contd a. Equipment shall be provided with insulation supports as called for in the GENERAL SPECIFICATIONS. b. Thickness Schedule Unless otherwise specified, insulation in excess of 1-1/2 inches total thickness shall be applied in two layers in accordance with thickness schedule shown . in II. B. 2. a. (L), of this Specification. c. Curved Surfaces On all equipment, insulation block shall be cut into curved segments to fit vessel surface and applied to vessel sides and heads in staggered position with all joints tightly butted. Block shall be applied to vessel sides with linear dimension paralleling axis of vessel. Typical installation is shown in Figure 32-H-l. APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO VESSEL FIG 32-H-l -4 - II. SPECIFICATION 32-H B. APPLICATION - contd 1. Equipment - contd d. Flat Surfaces Block insulation shall be applied to flat surfaces in staggered position with all joints tightly butted. It shall be secured with wire attached to blank nuts or other approved securement. On rectangular equipment, the blank nuts or other approved securements, shall be placed on 12-inch centers, staggered, for bottom sur faces and on 24-inch centers, staggered, for side and top surfaces. Typical installation is shown in Figure 32-H-2. -5- II. SPECIFICATION 3Z-H B. APPLICATION - contd 1. Equipment - contd e. Securement (I) All layers of insulation shall be secured with in sulation strap where contour of vessel permits firm and effective attachment. Insulation applied to irregular surfaces, where strap is impractica ble, shall be secured with wire, drawn taut, ends twisted and embedded in insulation. . (2) All layers of insulation on bottom heads of vertical equipment and heads of horizontal equipment shall be secured in place with insulation strap attached to insulation support as specified in UCCC Stand ard IS-31 and Figure 32-H-3. -6 - II. SPECIFICATION 32-H B. APPLICATION - contd 1. Equipment - contd f. Expansion Joints Expansion joints in flat surfaces or cylindrical vessels shall be insulated with, flexible blanket insulation. Typ ical installation is shown in Figure 32-H-4. MINERAL WOOL BLANKET OF SPECIFIED THICKNESS FACED OUTSIOE WITH EXPANOEO METAL LATH ANO ON THE INSIOE WITH il" uHErvX mWIiRdEc uNErmTTIuN/G! THICKNESS T, AS SPECIFIEO 'V BLANK NUTS Oft OTHERAPPROVEO SECUREMENT ON 12 CENTERS STAGGCREO APPLICATION OF BLANKET INSULATION TD EXPANSION JOINTS ON FLAT SURFACE FIG 32 - H . 4 -7- II. SPECIFICATION 32-H B. APPLICATION - contd I. Equipment - contd g. Mechanical Expansion Joints Corrugated mechanical expansion joints in piping (usu ally listed as equipment items) shall be insulated as shown in Figure 32-H-5. Where movement is likely to occur in the insulation, non-setting sealer shall be appliedto surfaces of insulation to provide proper slip joint. NO 28 6A. SHEET METAL JACKET KITTED APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO EXPANSION JOINTS EIG. 32 - M - S -8 - II. SPECIFICATION 3 2-H B. APPLICATION - contd 1. Equipment - contd h. Insulated Vessel Flanges Vesselflanges shall be insulated with block in the same manner as specified for body of vessel. An insulation support shall be provided immediately above vessel flange. The top of projecting flange insulation shall be sloped to shed water. Typical installation is shown in Figure 32-H-6. -9 - II. SPECIFICATION 32-H r B. APPLICATION - contd r 1. Equipment - contd T i. Vessel Nozzles Vessel nozzles shall be insulated as shown in Figure 32-H-7. i I I 4 i H INSULATION MITER CUT ANO FITTEO DIMENSIONS SHALL 0E IN ACCORDANCE WITH FABRICATION OATA FOR FITTING FINISH AS SPECIFIED THICKNESS T, AS SPECIFIED LINE NOZZLE -VESSEL WALL 8LINQ NOZZLE APPLICATION OF HYDROUS CALCIUM SILICATE TO VESSEL NOZZLES FIG. 32 - H - 7 II. SPECIFICATION 3 2-H B. APPLICATION - contd 1. Equipment - contd j. Vessel Legs (1) Vessel legs shall be insulated with block which shall extend over channel flanges and down legs to the standard fireproofing on legs. Insulation thick ness on legs shall be equal to that of vessel. (2) Vessel insulation shall be butted firmly against tank leg flange. Re-entrant space between channel flanges and over channel flanges between body in sulation shall be filled with block. Installation shall be as shown in Figure 32-H-8. - 11 - II. SPECIFICATION 3 2-H B. APPLICATION - contd 1. Equipment - contd k. Vessel Skirts Skirts supporting vertical equipment shall have their outer surfaces insulated. Unless otherwise specified, insulation shall extend from junction of skirt with bottom head to standard fireproofing or to foundation as shown in Figure 32-H-9. Thickness shall be as specified for body of vessel. 12 II. SPECIFICATION 32-H B. APPLICATION - contd 1. Equipment - contd l. Surface Finish When specified thickness of insulation has been applied, any small cracks or depressions shall be pointed up with insulating cement troweled flush with surface of insulation. m. Weather-Barrier Weather-barrier shall be installed in accordance with the GENERAL SPECIFICATION, I. B. 16l 2. Piping a. Pipe Insulation (1) Thickness Schedule Unless otherwise specified, pipe insulation in ex cess of 1-1/2 inch total thickness shall be applied in accordance with the following table: Total Scheduled Thickness, inches Inner Layer, inches Outer Layer, inches 2 2-1/2 3 3-1/2 4 1 1 1-1/2 1-1/2 2 1 1-1/2 1-1/2 2 2 (2) Securement All layers of insulation shall be securedwith stain less steel insulation strap spaced in accordance with GENERAL SPECIFICATION, I.B.5.C. and d. - 13 II. SPECIFICATION 32-H B. APPLICATION - contd 2. Piping - contd b. Fittings, Flanges and Valves (1) All sizes of fittings, flanges and valves shall be insulated with prefabricated fitting covers in ac cordance with DIMENSIONAL STANDARD FABRI CATION DATA. Where impractical to shop fabri cate, and with the approval of the representative of the Department of Design and Construction, fitting covers may be field fabricated provided work is in accordance with DIMENSIONAL STAND ARD FABRICATION DATA. Segments shall be carefully fitted to insure tight joints. (2) Cementing of shop fabricated assemblies shall be done with specified fabricating cement. In all cases the joints shall be as thin as possible, with just sufficient cement to obtain good adhesion and complete closure. In no case will wide cement joints, or voids and holes filled with fabrication cement, be permitted. Typical installations are shown in Figures 32-H-IO, 32-H-10, 32-H-12 and 32-H-13. 14 - II. SPECIFICATION 32-H B. APPLICATION - contd 2. Piping - contd b. Fittings, Flanges and Valves - contd APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO WELDING ELL FIG. 32 - M - 10 NOT E F(_ANGE COVER FABRIC AT EO IN accordance WITH oimensional STANOARO FABRICATION DATA. APPLICATION OF HYOROUS CALCIUM SILICATE INSULATION TO LINE FLANGE FIG 32 - H - ll 15 1 r II SPECIFICATION 32-H r B. APPLICATION - contd 2. Piping - contd r b. Fittings, Flanges and Valves - contd [ I f i f ,( l T [ i L APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO FLANGED ELL FIG 32- H - l 2 L APPLICATION OF HYDROUS CALCIUM SILICATE INSULATION TO FLANGED VALVE FIS 12 - H - I 3 I .. 16 II. SPECIFICATION 32-H B. APPLICATION - contd 2. Piping - contd b. Fittings, Flanges and Valves - contd (3) Surface Finish (a) Small cracks and depressions, where present, shall be filled and smoothed with insulating cement. (b) Where specifically noted, fittings, flanges and valves shall be given a skin coat only of speci fied hard surface finishing cement prior to application of coating. c. Polyethylene Conduit, Junction Boxes and Copper Tubing (1) Where specified on Insulation Design Schedule and/or Line List, polyethylene tubing (placed in metal conduit) and copper tubing, (for a minimum distance of 6'-0") from the junction boxes shall be insulated for fire protection. (2) Unless otherwise specified, insulation shall be a minimum of one inch thickness. (3) Insulation shall be applied to conduit and junction boxes in staggered position, where possible, and with all joints tightly butted. (4) Insulation on conduit and copper tubing shall be se cured with stainless steel insulation strap. (5) Insulation on junction boxes shall be securedwith stainless steel wire and blank nuts. If welding on junction boxes and covers is prohibited, stick clip fasteners shall be used. The body of the junction boxes shall be insulated separately from the removable covers. The in sulation on the covers shall be cut back from the bolt holes to provide easy removal of covers. - 17 - II. SPECIFICATION 32-H B. APPLICATION - contd 2. Piping - contd d. Weather-Barrier Weather-barrier shall be installed in accordance with GENERAL SPECIFICATION, I.B. 19. 18 - UNION GARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 32-L Hydrous Calcium Silicate and Cellular Glass Scope This specification describes the essential requirements for the purchase and the application of hydrous calcium silicate and cellular glass insulation to Low Temperature Equipment and Piping, normally operating below 70 "F, to be protected from fire exposure. Procedures outlined in the GENERAL SPECIFICATION, are appli cable to and constitute an integral part of this Specification. A. MATERIAL 1. Hydrous Calcium Silicate a. Composition Material shall be composed of hydrous calcium silicate blended with asbestos fibers in suitable proportion, with or without inorganic filler added. b. Properties Hydrous calcium silicate insulation shall have the following properties: Absorptivity..................................... Not more than 93% of vol ume after 24 hours sub mersion in water. Alkalinity pH shallbe notmore than 10. 0. Capillarity When placed on wet sur face absorption after one -half hour shall be 1 II. SPECIFICATION 3Z-L A. MATERIAL - contd 1. Hydrous Calcium Silicate - contd b. Properties - contd less than 100%, andafter seven days less than 300% of its original weight. Coefficient of Expansion . .After being heated to 1800F,then cooled, ex pansion upon reheating shall not exceed .000004 per F. Coefficient of Shrinkage . . When heated from 70F to 1800F(not reheated) linear shrinkage shall be less than 2%. Temperature Limits . . Shall be suitable for use from 0F to 1800F with out mechanical, thermal or chemical failure. Modulus of Rupture Thermal Conductivity . . Shall be above 50 psi . Shall not exceed values a t the following mean temperatures: Mean Conductivity T emp. F Btu/hr.,sq.ft. , F, in. thickness 100 400 800 1200' 0. 43 0. 58 0. 78 1.09 Thermal Diffusivity Shall not exceed 0.325 sq. ft. per day. -2- II. SPECIFICATION 32-L A. MATERIAL - contd 2. Properties - contd Combustibility . Compressive Strength Density Flexural Strength . Elasticity, Modulus of . Hygroscopicity. Resistance to Abrasion . Resistance to Acids or . Caustic s Specific Gravity . Specific Heat . Shall be incombustible. Percent of deformation shall be less than listed below: Load Deformation lbs./sq.in. per cent 20 2 60 6 100 10 10 to 14 lbs./cu. ft. Shall be not less than 40 psi. Shall be not less than 35, 000 psi. After oven dried at 200F to 230 F, sample shall not gain over 10% by weight when exposed to air at 70 F, 90 RH for 14 days. When placed in Rotap on twenty mesh a 3 x 3 x 1-1/2 sample shall not have lost more than 25% after 10 minute run, nor more than 40% after 2 0 minute run. It shall be resistant to most common caustics. ( Not considered as an acid resistant material.) 0. 15 to 0. 28 0. 20 to 0. 30 Btu/lb. 'F. II. SPECIFICATION 32-L A. MATERIAL - contd I. Calcium Silicate - contd b. Properties - contd Thermal Shock Resistance . Material shall not spall, chip or crack, or other wise fail when heated to 1800F and then quenched with water. 2. Cellular glass insulation shall have the following proper Acid Resistance................................... Impervious to common acids and acid fumes. Alkalinity................................................. pH = 7. 5 Capillarity......................................... 0 Coefficient of Expansion . 0.0000040 per F Combustibility................................... Incombustible Composition.......................................... A true glass; com pletely inorganic Compressive Strength 100 lbs. per sq. in. .Density................................................. 9 lbs. per cu. ft. Flexural Strength............................ 100 lbs. per sq. in. Hygroscopicity................................... No increase in weight in 246 days in air at 90% relative humidity. Modulus of Elasticity 200,000 lbs. per sq. in. Shear Strength . 64 lbs. per sq. in. Specific Gravity. 0. 16 Specific Heat. 0.20 Btu per lb. Tensile Strength 84 lbs. per sq. in. Thermal Conductivity Shall not exceed values a t the following mean temperatures: Mean Conductivity Temp.F Btu/hr., sq .ft. , F, in. thickness 50 0.40 300 0.55 Thermal Diffusivity . . . .0.40 sq. ft. per day. Water Absorption............................0.2% by volume on 2" x 1 2" x 18" block (all on surface only). . Temperature Limits .... Minus 350 F to plus 600 F. - :> II. SPECIFICATION 32-L A. MATERIAL. - contd 3. Accessory Materials a. Hydrous calcium silicate insulation - Kaylo No. 20 or approved alternate. b. Cellular glass insulation - Foamglas. c. Stainless Steel - Insulation Strap Type 304, l/2" x 0.020" or approved alternate. d. Stainless Steel Die Cut Strap- 3/4 inch x 0.023 inch, 2-inch fingers on 9-inch centers, A. J. Gerrard or approved alternate. e. Clips - Stainless Steel, l/2 inch double pronged, Type 304 or approved alternate. f. Stainless Steel Wire, 0.0475 inch diameter, 18 gage, Type 304 cold drawn, bright-annealed, stainless steel wire or approved alternate. g. Fabricating cement (for use with calcium silicate) Franset refractory cement, or approved alternate. h. Fabricating cement (for use with cellular glass) Miracle RT-100, or approved alternate. i. Cushioning blanket - 31b. density, l/2-inch thick glas s fiber insulation, or approved alternate. j. Weather-barrier coating (color as specified - Vimasco WC-1 or Benjamin Foster Sealfas "C" or approved alternate. k. Reinforcing cloth - Glass fiber, 10 x 10 thread count with starch binder, Glass Mesh, Inc. or approved alternate. l. Vinyl anti-abrasion coating - Vimasco 500, or ap proved alternate. m. Vinyl asphalt joint sealer - Vimasco 49, or approved alternate. n. Non-setting sealer - Benjamin-Foster 30-73, or ap proved alternate. `-4- n. SPECIFICATION 32-L B. APPLICATION 1. Equipment a. Equipment shallbe provided with insulation supports as called for in the GENERAL SPECIFICATIONS I. B. 4. b. Thickness Schedule Unless otherwise specified, insulation shallbe applied in multi-layer construction. Inner layer shall be one inch thick glass fiber blanket, compressedto one-half inch. Second layer, or inner layers, as specified in GENERAL APPLICATION I. B. 1. , shall be required thickness of cellular glass, but not less than 1-1/2 inch thick. Outer layer shall be 1-1/2 inch thick hydrous calcium silicate insulation. c. Cushioning Blanket On all equipment, a one-half inch thick blanket shall be applied over the entire surface, as a cushioning material, prior to the application of the cellular glass insulation. Blanket shall be held in place with a mini mum amount of No. 18 gage, stainless-steel wire. Cellular glass insulation shall then be applied over blanket in the following manner. Cushioning material shall not be considered as part of the specified insu lation thickness. d. Curved Surfaces (1) Cellular glass block insulation (curved segments or shaped head segments) shallbe shop fabricated and fitted to a one-inch greater diameter than that of the vessel to which it is applied. Block insu lation shall be applied over cushioning material on all equipment, with all joints tightly butted. Multiple layers of insulation shall be applied so that the butt joints of one layer do not coincide with those of any other layer. -5- II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd d. Curved Surfaces - contd (2) All butt edges and ends of insulation fabricated for inner layer, or layers, shall be given a smooth brush or spray coat of anti-abrasion coating and allowed to dry for a minimum of one-half hour, but preferably two hours, before application of in sulation to equipment. (3) All butt edges and ends of outermost layer of cell ular glass (or single layer) formed insulation shall be sealed with a buttered coat of vinyl asphalt joint sealer. This coating shall be only of suffi cient thickness, to provide proper adhesion, seal, and cushion between the individual pieces of insula tion. Typical installation is shown in Figure 32-L-l. -6 - II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd d. Curved Surfaces - contd (4) Calcium silicate block shall be properly cut into curved segments to fit the outside surface of the cellular glass insulation, and applied to insulated sides and heads of vessel in staggered position, with all joints tightly butted. Block shall be applied to vessel sides with linear dimension paralleling axis of vessel. e. Securement (1) All layers of cellular glass and calcium silicate insulation shall be secured in place with stainless steel insulation strap where contour of vessel per mits firm and effective attachment. Insulation shall be secured to irregular surfaces, with No. 18 gage stainless steel wire. -7- II. SPECIFICATION 3Z-L B. APPLICATION - contd 1. Equipment - contd e. Securement - contd (2) Inner layer or layers of cellular glass insulation on bottom heads of vertical equipment, or heads of horizontal equipment, shall be held in place-with specified stainless-steel insulation strap secured to insulation supports as shown in UCCC Stan dards IS-31, IS-36, and IS-42. Any slots cut in the cellular glass insulation, resulting from tight ening of the tie wires, shall be filled with specified joint sealer. Outer layer of cellular glass insula tion on bottom heads of vertical equipment, or heads of vertical equipment, shall be secured with insulation strap, as shown in Figure 32-L-2. 32- L- t -8 - II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd e. Securement - contd (3) Outer layer of calcium silicate on bottom heads of vertical equipment or heads of horizontal equip- . ment shallbe secured with stainless steel insulation strap as shown in Figure 32-L-3. 1/2" X .02* STRAP, AS SPECIFIED V-ON 9* centers, run unoer / FINGERS OF VERTICAL STRAP 3/4" X .023" DIE CUT STRAPPING WITH 2" FINGER ON 9" CENTERS AS SPECIFIED. STRAP TO BE ON 12*CENTERS WITH FINGERS POINTED OOWN. NOTE: EXTENO DIE CUT STRAPP. ING THE ENTIRE LENGTH OF VESSEL CYLINOER, OR A MIN. OF 6*- 0! AS 1/4 DIA. STAINLESS STEEL RING AROUNO BOTTOM NOZZLE; NO RING IS REQUIRED IF VESSEL DOES NOT HAVE A NOZZLE ON BOTTOM. AS STRAPS WILL CONTINUE THROUGH TO OPPOSITE SIOE. SPACE RING TEMPORARILY WITH WIRE SUPPORTS. SECUREMENT FOR OUTER LAYER OF HYDROUS CALCIUM SILICATE INSULATION OVER CELLULAR GLASS INSULATION ON WELDED DISHED HEADS FIG. 32-L-3 -9- II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd f. Expansion Joint (1) Cellular glass - calcium silicate applications shall be provided with expansion-contraction joints at vessel flanges, constructed as shown in Figure 32-L-4. Where movement is likely to occur, non setting sealer shall be applied to surfaces of insulation, as shown, to provide proper slip joint. CUSHIONING BLANKET- WEATHER-BARRIER AS SPECIFIED -APPROVED CEMENT USEO TO JOIN CELLULAR GLASS ^BLOCKS FOR SHOP FABRICATION OF SEGMENTS SURFACES COATED WITH NON-SETTING SEALER t--OUTERMOST 2HT (APPROX.) OF JOINT \ FACES COATED WITH JOINT SEALER CUSHIONING BLANKET- l'>i THICK HTOROUS CALCIUM SILICATE INSULATION FILL WITH CUSHIONING BLANKET VESSEL FLANGE -OUTER LAYER BUTT JOINTS OF CELLULAR GLASS SHALL BE COATED WITH JOINT SEALER f THICK HYDROUS CALCIUM SILICATE CELLULAR GLASS BLOCK ON EOGES SURFACES OF CELLULAR GLASS INSULATION SHALL BE COATEO WITH -ANTI-ABRASION COATING AT TIME OF INSTALLATION. BLOCK SHALL BE INSTALLEO WHILE COAT iS STILL TACKY - -BLOCK ON EOGE SUPPORTED BY VESSEL SEGMENTS AT THIS POINT HEAVY FILLET OF CAULKING MASTIC TREAT INNER LATER BUTT JOINTS RITH ANTl-A0RAS ON COATING ANO ALLOW TO DRY BEFORE INSTALLATION HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION ON LOW TEMPERATURE VESSEL FLANGE FIG 3 2-L - A 10 II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd f. Expansion Joint - contd (2) Longitudinal contraction of vessels shall be pro vided for by installing expansion-contraction joints at the insulation supports, as shown in Figure 32-L-5. Where more than one total thickness is specifiedfor a vessel, an insulation support shall be provided at the junction of two different thick nesses, and insulated in a manner similar to that shown in Figure 32-L-5. Where movement is likely to occur, non-getting sealer shall be applied to surfaces of insulation, to provide proper slip joint. II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd f. Expansion Joints - contd (3) One inch of cushioning blanket shall be packed around nozzles and projections where they extend through the insulation, as shown in Figure 32-L.-6. Where movement is likely to occur, non-setting sealer shall be applied to surfaces of insulation to provide proper slip joint. CUSHIONING BLANKET .CELLULAR CLASS INSULATION HEAVY FILLET OF CAULKING MASTIC LOW TEMPERATURE VESSEL TILL WITH CUSHIONING BLANKET WEATHER-BARRIER AS SPECIFIED OUTER LAYER BUTT JOINT OF CELLULAR GLASS SHALL BE COATEO WITH JOINT SEALER TREAT INNER LAYER BUTT JOINTS WITH ANTI-ABRASION COATING ANO ALLOW TO DRY BEFORE INSTALLATION 1-1/2' HYOROUS CALCIUM SILICATE INSULATION 'SURFACES COATEO WITH NON- SETTING SEALER HYDROUS CALCIUM SILICATE - CELLULAR GLASS INSULATION OF NOZZLE ON LOW TEMPERATURE VESSEL II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd g. Mechanical Expansion Joints Corrugated mechanical expansion joints in piping (usu ally listed as equipment items) shall be insulated as shown in Figure 32-L-7. Where movement is likely to occur, non-setting sealer shall be applied to surfaces of insulation to provide proper slip joint. SHEET METAL JACKET SECUREO AT CENTER ONLY WITH 020" STAINLESS STEEL STRAP THIS OISTANCE TO BE TWICE THICKNESS <T)OF INSULATION EXTENO FITTrNG FINISH MIN 6" OVER PIPE INSULATION FINISH W THICK HYOROU! CALCIUM silicat INSULATION INNER LAYER 8UTT JOINTS COATED WITH ANTI-ABRASION COATING AND ALLOWED TO ORY BEFORE INSTALLATION INNER BORE OF JOINT COVER TO 8E COATEO WITH ANTI- A8RA$I0N COATING ANO ALLOWED TO ORY BEFORE installation. NO 26 GAGE STAINLESS STEEL METAL JACKET TO PROJECT OVER PIPE NSULATION A MINIMUM OF 6 OUTER LAYER BUTT JOINTS OF CELLULAR GLASS COATED WITH JOINT SEALER- HEAVY FILLET OF CAULKING MASTIC Jr* if'1/ 9** y A ^ ^ '/r y'*' -jf -JJ< y V NOTE IF PIPE INSULATION IS NOT WEATHER-BARRIER AS SPECIFIED NO INSULATION eETWEENN SHEET METAL ANO EXPANSION JOINTS IN THIS AREA--------- SUFFICIENTLY THICK THAT METAL JACKET WILL CLEAR FLANGES, INSTALL INSULATION COLLARS A MINIMUN OF 9* V THICK COAT OF NON-SETTING SEALE WIDE ANO OF SUFFICIENT THICKNESS TO PROVIOE NECESSARY CLEARANCE. HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION ON LOW TEMPERATURE EXPANSION JOINT FiG. 32 - L - 7 - 13 - II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd h. Flat Heads (1) Insulation on top flat-heads of vertical equipment shall be applied in the same manner as previously described in this Specification. Water pockets shall be eliminated and proper drainage provided as shown in Figure 32-L-8. (2) All top nozzles on insulated equipment shall be pro vided with flashing as shown in Figure GA-3, of GENERAL SPECIFICATIONS. FILLER BLOCK WEATHER-BARRIER AS SPECIFIED MIN. V` OVER STUD-- TREAT INNER LAYER BUTT JOINTS WITH ANT I - ABRASION COATING 6 ALLOW TO DRY BEFORE INSTALL ATION OUTER LAYER BUTT JOINTS OF CELLULAR GLASS SHALL BE COATED WITH JOINT SEALER------------- I V THICK WYOROUS CALCIUM SILICATE INSULATION -- HEAVY FILLET OF CAULKING MASTIC THICKNESS T, nAS SPECIFIED FLASHING AS PER GA-3 /`if* ^ \^ ^ >iJ'/V VESSEL NOZZLE TWO LAYERS OF CUSHIONING BLANKET VESSEL HEAO LOW TEMPERATURE VESSEL CELLULAR GLASS BLOCK ON EDGE TO SUPPORT FLANGE INSULATION SURFACES OF CELLULAR GLASS SHALL BE COATEO WITH ANTI-ABRASION COATING AT TIME OF INSTALLATION BLOCK SHALL BE INSTALLED WHILE COAT IS STILL TACKY CUSHIONING BLANKET --SURFACES COATED WITH NON-SETTING SEALER THICKNESS T. AS SPECIFIED HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION ON LOW TEMPERATURE FLAT VESSEL HEAP FIG 32 -L - 6 \ 14 - II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd i. Vessel Legs (1) Vessel legs shall be insulated with block which shall extend over channel flanges and down channel legs to the junction with any fire resistant material. Thickness shallbe as specifiedfor body of vessel. Body insulation shall be brought up to and butted firmly against tank leg flange. (2) Re-entrant space between channel flanges shall be filled with block and cemented in place with an approved adhesive. Surface of fire-resistant ma terial abutting tank leg insulation shall be coated with weather-barrier coating. Installation shall be as shown on Figure 32-L-9. SECURE LEG INSULATION WITH WIRE OR STRAP ANO APPROVED ADHESIVE I V HYOROUS CALCIUM SILICATE INSULATION HEAVY FILLET OF CAULKING MASTIC DIE CUT STRAP USEO AS AN ANCHOR FOR LEG ANO HEAD INSULATION SECUREMENT STRAP AROUf CIRCUMFERE OUTER LAYER 0UTT JOINTS OF CELLULAR GLASS SHALL BE COATEO WITH JOINT SEALER 010 SHALL 8E FILLED WITH CAULKING MASTIC THICKNESS T, AS SPECIFICO TREAT INNER LAYER BUTT JOINTS WITH ANTI .ABRASION COATING ANO ALLOW TO ORY BEFORE INSTALLATION USHtONING BLANKET SECTION AA EQUIPMENT LEG HEAVY FILLET OF CAULKING MASTlC THICKNESS T, AS SPEC1FIE0 COAT TOP OF CONCRETE WITH VAPOR SEAL MASTIC BEFORE APP. LlCATlON OF INSULATION HYDROUS CALCIUM SILICATE - CELLULAR GLASS INSULATION FOR LOW TEMPERATURE VESSEL LEG FIG 32-L - 9 15 IL SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd j. Vessel Skirts (1) Both interior and exterior surfaces of skirts supporting vertical equipment shall be insulated. Insulation shall extend downward, from junction of skirt with bottom head, to junction with fire resistant material or to concrete pad. Thickness of insulation over skirt shall be as specified for body of vessel. Insulating material shallbe secured to inside of skirt with adhesive cement. (2) Support for insulation inside skirts and support for securement of bottom head insulation shall be in accordance with UCCC Standard IS-42. Installa- . tion shall be as shown in Figure 32-L-10. - 16 - II SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd k. Equipment Supports (1) Where equipment is supported on cradles, vessel insulation shall extend over cradles as shown in Figure 32-L-1L -- CELLULAR GLASS INSULATION CUSHIONINC BLANKET +* "X* STEEL CRAOLE SHORTEST-- --(C)0ISTANCE A T y OR TO PAO '.TVI \ HEAVY FILLET OF CAULKING MASTIC k';*W SECTION AA SECTION BB OUTER LAYER BUTT JOINTS OF CELLULAR GLASS COATED WITH JOINT SEALER WEATHER-8ARRIER AS SPECIFIEO CUSHIONING BLANKET I '/ THICK HYOROUS CALCIUM SILICATE TREAT INNER LAYER BUTT JOINTS WITH ANTI-ABRAS* ION COATING ANO ALLOW TO ORY BEFORE INSTALLA TION COAT TOP OF CONCRETE WITH VAPOR SEAL COAT ING BEFORE APPLICATION OF INSULATION OAT ALL JOINTS AROUND STEEL CRADLE WITH ANTI-ABRASION COATING ANO ALLOW TO ORY BEFORE INSTALLATION I1'** THICK HYOROUS CALCIUM SILICATE HYDROUS CALCIUM SILICATE-CELLULAR r,i ass insiii ATinw Qf CRADLES a SUPPORTS ON LOW TEMPERATURE VESSEL------ FIG 32 -L -l I 17 II. SPECIFICATION 32-L B. APPLICATION - contd I. Equipment - contd k. Equipment Supports - contd (2) Where equipment is supported by structural steel members, insulation shall be extended not less than four times the specified insulation thickness in each direction, measured from junction of vessel with insulated support lug. Thickness of insula tion over steel supports shall be not less than onehalf that specified for body of vessel. Thickness of insulation over support lugs to be the same as body insulation. Installation shall be as shown in Figure 32-L-12. CUSHIONING BLANKET I V THICK CALCI SILICATE INSU LATION SUPPORT LUG WEATHER BARRIER AS SPECIFIED-- CELLULAR GLASS INSULATION COAT ALL JOINTS AROUND STEEL SUPPORT WITH ANTIABRASION COATING ANO ALLOW TO ORY BEFORE IN STALLATION HEAVY FILLET OF CAULKING MASTIC UTER LAYER BUTT JOINTS OF CELLULAR GLASS SHALL BE COATEO WITH JOINT SEALER SECTION A A1 INNER LAYER BUTT JOlNTSCGATED WITH ANTI-ABRASION COATING ANO ALLOWED TO ORY BEFORE INSTALLATION FOUR T MEASURED FROM JUNCTION OF VESSEL WITH INSULATEO SUPPORT LUG SECTION 88 HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION ON LOW TEMPERATURE VESSEL LUGS & SUPPORTING STEEL FIG -32-L-I2 / - 18 - II. SPECIFICATION 32-L B. APPLICATION - contd 1. Equipment - contd 1. Weather-Barrier Weather-barrier shall be applied in accordance with GENERAL SPECIFICATIONS, I.B.9. 2. Piping a. Pipe Insulation (1) Unless otherwise specified, insulation shall be applied in multiple layer s. Inner layer, or layers, shall be the required thickness of cellular glass insulation. The outer layer shall be a minimum 1-1/2 inch thick hydrous calcium silicate insulation. (2) Cellular glass insulation thicknesses in excess of 2-1/2 inches shall be applied in multiple layers as specified in GENERAL SPECIFICATIONS, I.B .4. (3) Pipe insulation shall be applied in staggered posi tion, in accordance with Figures GA-1 and GA-2 of the GENERAL SPECIFICATIONS. (4) All butt edges and ends of single layer cellular glass insulation, and outer layer of multiple layer cellular glass applications shall be buttered with joint sealer before application. Joints shall be drawn together, when insulation is applied, so that only a very thin, vapor - tight, vapor-seal coat separates the sections of insulation. (5) Insulation shall be applied with all joints tightly butted and fitted, to eliminate voids. Large voids shall not be filled with vapor seal coating, but eliminated either by refitting or replacing insula tion. Any rounded corners, on the insulation surfaces to be butted, shall be trued before appli cation. (6) Butt edges and ends, of all inner layers of cellular glass, shall be given asmoothbrushor spray coatof - 19 - II. SPECIFICATION-32-L B. APPLICATION - contd 2. Piping - contd a. Pipe Insulation - contd coating and allowed to dry for a minimum of onehalf hour, but preferably two hours, before appli cation. Care shall be exercised to obtain a thin even coat of only sufficient thickness to cover and fill the cut cells of the insulation. (7) Outer layer of calcium silicate shall not be ce mented to the inner layer of cellular glass. (8) When scheduled for installations where thermal shock is expected, a cushioning material, as speci fied, shall be applied to bare pipe prior to appli cation of cellular glass insulation. b. Fitting, Flange and Valve Covers (1) Fittings, flanges, and valve covers shall be shop fabricated, in accordance with the UCCC DIMEN SIONAL STANDARDS FABRICATION MANUAL. (2) Fittings, flanges and valve covers shall be fabri cated in two layers. Inside layer shall be the specified thickness of cellular glass insulation. Outside layer shall be 1-1/2 inch thick hydrous calcium silicate insulation. (3) Welded fitting covers shall be fabricated to fit snugly on the pipe. The two halves of the cover shall be cemented together, with joint sealer ap plied to the outermost 2-1/2 inches (approx. ) of the inner layers of cellular glass. The adjacent pipe insulation shall be fitted tightly to the butt ends of the fitting cover and sealed as specified for piping. Typical fitting covers are shown in Figures 32-L-13 and 32-L-14. - 20 - II. SPECIFICATION 32-L B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd TWO HALVES OF THE CELLULAR GLASS INSULATION CEMENTED TOGETHER WITH JOINT SEALER APPLIED TO THE OUTERMOST 2<2* (APPROX.) OF THE CELLULAR GLASS OF THE JOINT FACES INNER LAYER BUTTJOINTS COATEO WITH ANTI-ABRASION COATING ALLOWED TO ORY BEFORE INSTALLATION rr Xx J 5 <? * CELLULAR GLASS INSULATION TT 'tV * Ml A THICK HYOROUS CALCIUM SILICATE WEATHER BARRIER AS SPECIFIED \-* * S / V - BUTT JOINTS OF FITTING COVER ANO AOJACENT PIPE INSULATION TO BE COATEO WITH JOINT SEALER APPLIED TO THE OUTERMOST 2 *z` (APPROX.) OF THE JOINT FACES WEATHER-BARRIER AS SPEClFlED- CELLULAR GLASS MITERED PIPE INSULATION OUTER LAYER OF CELLULAR GLASS BUTT JOINTS COATED WITH JOINT SEALER I *" THICK HYDROUS CALCIUM SILICATE INSULATION CELLULAR GLASS PIPE INSULATION THICKNESS, T AS SPECIFIED HYDROUS CALCIUM SILICATE CELLULAR GLASS INSULATION ON LOW TEMPERATURE WELDED ELL "" ' FIG. 32-L-13 ' WEATHER.SARRtER AS SPEClFlEQ HEAVY FILL ET OF CAULKING MASHC TMICKNESS T, AS SPECIFIED CELLULAR GLASS INSULATION_______ . T wO HALVES OF THE CELLULAR GLASS INSULATION Shall 6E CEMENTED TOGETHER VflTH JOINT SEALER TO THE OUTERMOST 2 Y <APP ROX.) OF CELLULAR GLASS INSULATION OF THE JOINT FACES l<V THICK HYOROUS CALCIUM SILICATE INSULATION BUTT JOINTS OF FITTING COVER ANO ADJACENT PIPE INSULATION TO BE COATED WITH JOINT SEALER APPLIED TO THE OUTERMOST 2*V (APPRO* ! OF Th joint FACES OUTER LAYER BUTT JOINTS OF CELLULAR GLASS COATEO WITH JOINT SEALER COAT INNER LAYER BUTT JOIN TS WITH ANT l - ABRASION COATING A ALLOW TO ORY BEFORE INSTALL ATION HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION ON LOW TEMPERATURE WELDED TEE flO. 32 - L - l 1 II. SPECIFICATION 32-L B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd (4) All valves shall be packed and filled around valve stem, and packing gland' assembly, with valve sealer, to avoid water pockets. (5) Installation of typical fittings and valve are shown in Figures 32-L-15, 32-L-16, and 32-L-17. i HE TWO HALVES OF THE CELLULAR GLASS >INSULATION SHALL BE CEMENTEO TOGETHER WITH JOINT SEALER APPLIEO TO THE OUTER MOST *2 I/2*1APPR0X.) OF CELLULAR GLASS INSULATION OF THE JOINT FACES OUTER LAYER dUTT JOINTS OF CELLULAR GLASS COATED WITH JOINT SEALER :rT^C r-inner LAYER BUTT JOINTS COATEO WITH!. . . ANTI ABRASION CCATN j, ING ANO ALLOWED TO L . lt-1 ORT BEFORE INSTALLA. ` *'** TION it N -a. -- " * t* -iL i 2" MIN. 4 '/2* THICK HYOROUS CALCIUM SILICATE INSULATION ROUNO OUTSIOE CORNERS 4EAVY FILLET OF CAULKING MASTIC SURFACES COATEO WITH NON-SET TING SEALER ANO ALLOWED TO ORY BEFORE INSTALLATION FILL WITH CUSHIONING BLANKET THICKNESS T, AS SPECIFIED WEATHER-8ARRIER AS SPECIFIED HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION ON LOW 'TEMPERATURE LINE FLANGE FIG. 32-L-lS 22 II. SPECIFICATION 32-L B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd CELLULAR GLASS INSULATION CUSHIONING BLANKET OUTER LATER BUTT JOINTS' OF CELLULAR GLASS.COATED WITH JOINT SEALER HE TWO HALVES OF THE CELLULAR GLASS SHALL 8E CEMENTED TOGETHER WITH JOINT SEALER APPLIEO TO THE OUTERMOST 2 '/&" (APPROX.) OF CELL ULAR GLASS INSULATION OF THE JOINT FACES I1/," THICK HTDROUS CALCIUM SILICATE INSULATION THICKNESS T, AS SPECIFIED THICKNESS T, AS SPECIFIEO ROUNO OUTSIOE CORNERS INNER LATER BUTT JOINTS COATEO WITH ANTI-ABRASION COATING ANO ALLOWED TO ORT BEFORE APPLICATION SURFACES COATEO WITH NONSETTING sealer -- WEATHER -BARRIER AS SPECIFIEO HEAVY FILLET OF CAULKING MASTIC HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION ON LOW TEMPERATURE FLANGED ELL FIG. 32 * L - 16 TWO halves of THE COVER SHALL BE CEMENTED TOGETHER WITH JOINT .SEALER APPLIEO TO THE OUTERMOST 2V2`IAPPROX| OF THE CELLULAR GLASS OF THE JOINT FACES ROUNO OUTSfOE CORNERS SURFACES COATEO WITH NON SETTING sealer PACK ANO FILL BETWEEN INSULATION ANO VALwE STEM WITH VALVE SCALER EXTENO VAPOR SEAL COATING OVER METAL HEAVY FILLET OF CAULKING MASTIC CELLULAR GLASS INSULATION OUTER LATER BUTT JOINTS OF CELLULAR GLASS COATEO WITH JOINT SEALER ViJ j I" ' --INNER LlAaYy!er BUTT JOINTS COATEO Yj WITH ANTI -ABRASION COATING AND -ALLOWEO TO ORY BEFORE INSTALL* AflON `L3J) SI \ v \ ~\ \ N \ \ls*] -ITHICK HYDROUS CALCIUM SILICATE Fill WITH CUSHIONINGblanket L- WEATHER. BARRIER AS SPECIFIED HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION ON LOW TEMPERATURE FLANGED VALVE FIG J2 - L - IT II. SPECIFICATION 32-L B. APPLICATION - contd 2. Piping - contd b. Fitting, Flange and Valve Covers - contd (6) All fittings shall befitted andassembled with verythin, tight joints. Cellular glass fittings shall be cemented with specified fabricating cement. In allcasesthe joints shall be thin, with just sufficient cement to obtain good adhesion and complete closure. Wide cement joints, voids, or holes plugged with fabricating cement will not be per mitted. c. Securement All layers of cellular glass and calcium silicate pipe insulation shall be secured in place with stainless steel Insulation Strap in accordance with spacing specified in GENERAL SPECIFICATIONS, I. B.5, c, d. d. Supports and Hangers (1) Where horizontal, low temperature piping is sup ported on the outside of insulation surfaces, as per UCCC Standard IS-19, insulation (cellular glass) shall be complete with weather - barrier applied before piping is placed incradles. UCCC Standard IS-19 is a guide to the maximum hori zontal span of pipe which maybe supported on the outside of insulation. U) Hangers attached directly to piping shall be insu lated as shown in Figure 32-L-18. - 24 II. SPECIFICATION 32-L B. APPLICATION - contd 2. Piping - contd d. Supports and Hangers - contd TWO HALVES OF THE CELLULAR GLASS SHALL BE CEMENTED TOGETHER WITH JOINT SEALEK APPLIED TO THE OUTERMOST 2 1/2 UPPROX ) OF THE JOINT FACES | 4* HYDROUS CALCIUMSILICATE INSULATION HANGER ROO -- I HYDROUS CALCIUM SILICATE INSULAT ION TO POINT OF ROO ATTACHMENT COAT INNER BORE OF INSULATION WITH ANTI-ABRASION COATING ANO ALLOW TO ORY BEFORE INSTALLATION HEAVY FILLET OF CAULKING MASTIC AT ALL INSIOE CORNERS THICKNESS T,* AS SPECIFIED BUTT JOINTS OF FITTING COVER ANO AOJACENT CELLULAR GLASS INSULATION TO BE COATED WITH JOINT SEALER APPLIED TO THE OUTER MOST 2 1/1' (APPROX)OF THE JOINT FACES AS SPECIFIED INNER LAYER BUTT JOINTS COATEO WITH ANTI.ABRASION COATING ANO ALLOWEO TO ORY BEFORE INSTALLATION SECTION HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION ON HANGER CONNECTED DIRECTLY TO LOW TEMPERATURE PIPE FIG. 32-L-I8 25 II. SPECIFICATION 32-L B. APPLICATION - contd 2. Piping - contd e. Expansion-Contraction Joints (1) Expansion and contraction joints shall be installed, as per Figure 32-L-19, in both horizontal and vertical straight run piping, at intervals as follows: Single layer Double layer Triple layer - one for each 45 feet - one for each 33 feet - one for each 21 feet (2) Where flanged joints occur within these limits, ex pansion and contraction shall be provided for in the flange cover and expansion-contraction joints in insulation will not be required. (3) Joints shall be packed tightly with strips of cush ioning blanket. INNER ANO OUTER BORE OF SLIP JOINTS COATEOWITH NON-SETTING SEALER JOINT SEALER INT0 SP4CE CELLULAR CELLULAR GLASS INSULATION- h,viT~ 1 HYOROUS CALCIUM I----8 r*1SILICATE INSULATION-; 1/,'J -- -- 1--V,- s .s-A. ^ -V a'/z' <> . . glass ------- np'/Z^INSULATTON / / vi \ K <w LOW TEMPERATURE PIPE WEATHER-BARRIER', AS SPECIFIED 3^ s " SPACE FILLEO WITH CUSHIONING BLANKET 4--^ TEMPERATURE PIPE ^_ ONE LAYER INSULATION CONTRACTION JOINT REQUIRED EVERY 45* OP STRAIGHT RUN INNER ANO OUTER BORE OF SLIP JOINTS 'WEATHER-BARRIER COATED WITH NON-SETTING SEALER AS SPEClFlEO three layer insulation - CONTRACTION JOINT REQUIRED EVERY 2 1* CELLULAR GLASS NSULATION --- -INNER ANO OUTER BORE OF SLIP JOINTS COATEO ".*H NON-SETTLING SEALER OP STRAIGHT RUN \y <- < \ r-V -<Si / f --y' -r-r ^ *i '1 \ '-y \ ^ ----- ,v** Thick HYOROUS CALCIUM SILICATE INSULATIION . LOW temperature pipe rf% -r t" 4* L- > v1 v ^ >3 > - SPACE PILLED WITH i / \ Cushioning Blanket~ / WEATHER-barrier AS SPECIFIED TWO layer insulation *is - .1 -QINT SEALER v INTO SPACE NOTE: (FOR CELLULAR GLASS INSULATION) ALL INNER LATER BUTT JOINTS COATED WITH ANTI-ABRASION COATING ANO ALLOWED TO ORY BEFORE INSTALLATION. ALL OUTER LATER BUTT JOINTS COATEO WITH JOINT SEALER CONTRACTION JOINT REQUIRED EVERY 33* OF STRAIGHT RUN HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION EXPANSION & CONTRACTION JOINT FOR HORIZONTAL PIPING FIG 3 2 * L - 19 - 26 II. SPECIFICATION 32-L B. APPLICATION - contd 2. Piping - contd e, Expansion-Contraction Joints - contd (4) Where it is necessary to install expansion-contrac tion joints in insulation on vertical piping, an insulation support shall be provided. Installation shall be as shown in Figure 32-L-20. 1THICK HYDROUS CALCIUM SILICATE INSULATION CELLULAR GLASS BLOCK KEYED TO SUPPORT- WEATHER-BARRIER AS SPEClFlE SURFACE OF SLIP JOINT COATED WITH NON-SETTING SEALER CELLULAR GLASS INSULATION CELLULAR GLASS INSULATION SHALL BE COATED WITH ANTI-ABRASION COATING AT TIME OF INSTALLATION. SLOCK SHALL BE INSTALLED WHILE COAT IS STILL TACKY ---INSULATION SUPPORT FILL WITH CUSHIONING BLANKET HEAVY FILLET OFCAULKING MASTIC OUTER LAYER BUTT JOINTS OF CELLULAR GLASS SHALL BE COATED WITH JOINT SEALER INNER LAYER BUTT JOINTS COATEO WITH ANTI-ABRASION COATING ANO ALLOWED TO DRY BEFORE INSTALLATION HYDROUS CALCIUM SILICATE-CELLULAR GLASS INSULATION VERTICAL EXPANSION AND CONTRACTION JOINT ON LOW TEMPERATURE PIPING FIG. 32 - L - 20 f. Weather-Barrier Coating Weather-bar rier shall be installed in accordance with the GENERAL SPECIFICATION, LB.16. g. Steam Traced Installations Steam-trace lines, where specified, shall be installed and insulated in accordance with the GENERAL SPECI FICATION, LB. 15. UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION THERMAL INSULATION SPECIFICATIONS II. SPECIFICATION 37-H Insulated Conduit Scope This specification describes the essential insulation require ments for the installation of insulated conduit used on under ground systems normally operating at temperatures up to and including 750F. A. MATERIAL 1. Composition a. The insulated conduit is an insulated prefabricated pipe system, encased in a corrosion protected metal jacket. b. Insulation material for use in conduit will be speci fied in Insulation Line and Equipment List. 2. Accessory Materials a. Insulated Conduit - Ric-wil Hel-cor, Durant PreSealed, Kaiser Ebko, or approved alternate. b. The insulated conduit piping system shall be pur chased as a package unit, in accordance with the piping drawings and piping specifications, with all necessary accessories and installation instruc tions furnished by the conduit manufacturer. II. SPECIFICATION 37-H B. APPLICATION I. Trench Preparation a. Lines shall be installed in accordance with piping drawings. b. The bottom of the trench shall be smooth and uniform prior to the installation of conduit. 2. Process Pipe a. After process line has been welded and tested, in sulation shall be applied to uninsulated joints. b. All loose paint, dirt, grease, rust, scale, wax, and other extraneous materials shall be removed from the exposed ends of the pipe before the conduit con nections are made. c. Insulation of the type specified for conduit, shall be applied to the area of the pipe left bare for field welding, and joints and cracks filled with insulating cement. - 2- II. SPECIFICATION 37-H B. APPLICATION - contd 3. Field Connections (1) Field Welded Conduit Connections (Fig. 37-H-l) a. An asbestos felt jacket shall be applied over the insulation and secured with wire. b. The cylindrical conduit closure supplied by the manufacturer shall be installed at the joint, and the circumferential and longitudinal joints weld ed. c. The system shall be required to withstand air test at 15 PSI without leaks. d. The welds shall be smoothed and cleaned, and an industrial tape applied around each circum ferential weld. Entire connection shall then be wrapped continuously with tape. WELOCO AT JOINTS PREFABRICATED INSULATED PIPE CONDUIT TYPICAL WELDED FIELD CONNECTION FIGURE 37-N-l - 3- II. SPECIFICATION 37-H B. APPLICATION - contd 3. Field Connections - contd (2) Mechanical Conduit Connections (Fig. 37-H-2) a. Entire area of exposed insulation shall be thor oughly covered with jacketing and cold water paste. b. The outer metal jacket, furnished by manu facturer, shall be installed over-lapping the conduit jacket at both ends, and sealed with in sulating cement before securing with stainless steel insulation strap. c. A 2" x 3" pour hole shall be cut in the top center of the connection jacket if the pipe is level. The pour hole shall be located at the highest point. -4- II. SPECIFICATION 37-H B. APPLICATION - contd 3. Field Connections - contd (2) Mechanical Conduit Connections(Fig. 37-H-2)-contd d. The asphalt shall be poured in joint, at a temp erature between 400F aLnd450*F, inthefollowing stages. 1. Fill to top of insulation and let cool for one hour. 2. Fill to within l/2" of the topandlet cool for one hour. 3. Fill until asphalt is level with top of metal jacket. 4. Conduit Terminals a. When the insulation conduit terminates at a building, manhole or pit, it shall extend through the concrete to the inner face. A weather seal shall be applied between the conduit and the concrete. b. A water seal shall be applied to the conduit end, and the remainder of the line insulated as specified in the Insulation Line and Equipment List. 5. Backfill a. Boulders and concrete debris shall notbeusedas a portion of the backfilling materials. b. The soil shall be carefully deposited in uniform lay ers not over 6" thick, carefully and solidly tamped so as not to injure or disturb the conduit. c. Backfilling shall be done to both sides of the conduit simultaneously. - 5. - I i UNION CARBIDE CHEMICALS COMPANY DEPARTMENT OF DESIGN AND CONSTRUCTION f-' u I THERMAL INSULATION SPECIFICATIONS s ii< . II. SPECIFICATION 39-H Underground Bituminous Fill r<:f! ' Scope X ' This specification describes the purchase and application of a i bituminous insulationfor use on underground flanged piping nor i mally operating at temperatures from 220 F up to and including 520F. A. MATERIAL 1. Composition Material shall be composed of granulated bitumen, or volcanic rock mixed with a bitumen, when applied as loose fill and heat applied within pipe, produces a water proof Thermal Insulation. ii 1 2. Properties Bituminous fill insulation shall have the following properties. i Acid Resistance...............................Not effected by m o s t ` L common acids. Alkalinity.............................................Not effected by, m o s t common alkalies. Capillarity.......................................... Water resistant. Composition . . .... Pure bitumen, bitumen with volcanic rock, or approved equal. i Density.................................................. 25 to 41 lbs/cu. ft. i Specific Heat.................................... 300F 0.52 500F 0.61 I. i Ll SPECIFICATION 39-H - contd A. MATERIALS - contd 2. Properties - contd _ Thermal Conductivity . . . Shall not exceed values at the following mean temperatures: Temperature Limits . . 3. Accessory Materials M T', I I 22 i ' a. American Gilsonite Co. , Gilsula-c jmracxe Adhesive Insulfil, or approved alternate. - 2- H. SPECIFICATION 39-H - contd B. APPLICATION I. Piping a. Unless otherwise specified, insulation thickness shall be not less than specified on Fig. 39-H-l. Where the piping passes und< heavy loads, thickness of insu pipe shall be increased 3 inche i i APPLICATION OF BITIMINOUS FILL INSULATION TO UNDERGROUND PIPING FIG. 39-H-l b. The trench shall be dewatered and remain as such, until the installation is completed. -3- II. SPECIFICATION 39-H B. APPLICATION - contd 1. Piping - c ontd c. Process lines shallbe supported, welded and tested, and loose paint, dirt, rust, scale, wax, and other extraneous materials removec" material is applied.' d. The bituminous insulation fill the trench and then tamped aroi 10" stroke of a 8" x 8" x l/4" 8" area. e. Insulating mate rial shall be kep foreign matter before and dui cedure. f. Where the width of the trench is greater than .re quired, a leapfrog form shall be used for the side walls. The insulation mate rial shall be applied, and sides backfilled before forms are moved to the next position. g. The curing of the bituminous insulation shall be not less than the time and temperature specifiedby the manufacturer for the material supplied. h. Trench shall be backfilled only after curing is com pleted ,_unless the installation is being made in dry soil. i. A minimum of 12" backfill shall be placed over the top of the bituminous insulation as specified on Fig. 39-H-1. -4- H. SPECIFICATION 39-H B. APPLICATION - contd 2. Expansion Loops a. The insulation material shall be applied to ex pansion loops as shown in Fig. 39-H-2. -5- II. SPECIFICATION 39-H B. APPLICATION - contd 3. Transition and Termination a. Where the bituminous insulation system emerges above the surface, a transition shall be provided to the type of insulation speci" surface. Details of the tr Fig. 39-H-3. i b. Where lines insulated with} manhole or building wall, ai packing shall be applied be' sleeves. PREFORMED INSULATION AS SPECIFIED WEATHER-COATING SHALL OVER-LAP METAL JACKET SITIMINOUS FILL INSULATION <_.X..' . ;v 20 GAGE GALVANIZED STEEL JACKET RECOMMENDED ENVELOPS NOMINAL SIZE, INCHES 1 TO 4 s ano a (0 ANO It l Dimension 'a* MIN. INCHES 4 t 1 TRANSITION AND TERMINATION OF SITIMINOUS FILL INSULATION fib. is-H-3 I i I) ) -6 -