Document K6oaXz1nn9gnEzjbVgO3LGGeo
from w. J. Schreibeis MH 77623 IE-231 X6551
The following items are considered to be of priority concern in Department 77623, Industrial Hygiene and Safety. Some attempt has been made to arrange the items in descending order.
* AT&T Bell Laboratories facilities for high tech safety of toxic, pyrophoric materials. Maintaining state-of-the-art knowledge on new developments.
* Sampling programs to monitor OSHA regulated chem icals such as asbestos, arsenic, lead, beryllium, selenium.
* Odor investigation at Murray Hill. * Training programs to provide all employees with
needed training and orientation on matters of health and safety. Programs targeted at management as well as bargaining group.* * Investigation of accidents and incidents such as
Freon 12 explosion at AK; technical staff removing asbestos IE-308; Ga As incident. - Provide consulting services to AT&T Communications. * Right-to-Know training packages. * Maintain on-site contact with branch laboratories periodically. * Auditing of laboratories. * Murray Hill Upgrade program. - Review proposed legislation.
LLA 001499
G. M. Wilkening - 2
* Analysis of samples.
- Other consulting work.
Safety
In the area of Safety a well-balanced safety program is
maintained at various locations.
Included are the
following.
Active Safety Committees
Safety Centers featuring literature
*Eye protection program
Newsletter to inform technical ;r*-aff
CPR program
Demonstration of new equipment
OSHA accident statistics
Training programs
Accident investigation
MH-77623-WJS-jve
w. dJ Schreibeis
These items are required by existing legislation.
LLA 001500
AA
subject Request for Work Priorities
ATCT
Bell Laboratories
" June 18, 198S
l,Qm W. J. Schreibeis MH 77623 IE-231 X6551
%
G. M. Wilkening:
The following items are considered to be of priority concern in Department 77623, Industrial Hygiene and Safety. Some attempt has been made to arrange the items in descending order.
Industrial Hygiene
- AT&T Bell Laboratories facilities for high tech safety of toxic, pyrophoric materials. Maintaining state-of-the-art knowledge on new developments.
- Sampling programs to monitor OSHA regulated chem icals such as asbestos, arsenic, lead, beryllium, selenium.
- Odor investigation at Murray Hill.
- Training programs to provide all employees with needed training and orientation on matters of health and safety. Programs targeted at management as wf .11 as bargaining group.
- investigation of accidents and incidents such as 0_, Freon 12 explosion at AK; technical staff removing asbestos IE-308; Ga As incident.
- Provide consulting services to AT&T Communications.
- Right-to-Rnow training packages.
- Maintain on-site contact with branch laboratories periodically.
- Auditing of laboratories.
- Murray Hill Upgrade program.
- Review proposed legislation.
LLA 001501
G. M. Wilkening - 2
- Analysis of samples.
- Other consulting work.
Safety
In the area of Safety a well-balanced safety program is
maintained at various locations.
Included are the
following.
Active Safety Committees
Safety Centers featuring literature
Eye protection program
Newsletter to inform technical staff
CPP program
Demonstration of new equipment
OSHA accident statistics
Training programs
Accident investigation
LLA 001502
PARTS LIST Industrial Hygiene Survey Kit for Telecommunications
Supplier ~ MSA
Cost - $513
Part No. Purpose
459054 MSA Tube Holder 456226 Sampling Line Assembly 466117 Portable Pump Assembly Model G 456059 Battery Charger Assembly Sampling Lead, Asbestos, Metals, Sulfuric Acid Mist, Solvents, PCBs
Part Mo. 31966 Sling Psychrometer Purpose" Temperature and Relative Humidity
Supplier - Dupont
Cost - $936
Part No. Purpose
2639 10 Charcoal Tubes 2640 10 Florisil Tubes Sampling for Solvents, PCBs
Part No. 5300 Mark 1 Audio Dosimeter Purpose A-weighted Noise, OSHA Noise Dose
Supplier - Gilmont Cost - $65
Part No- F2260 No. 12 Compact Shielded Rotameter Purpose- Calibrate Sampling Pump
Supplier - Rational Prager Cost - $150
Part No. Purpose
6726065 Model 31 Gas Detector Pump Sampling for variety of gases or vapors must be ordered for eacb substance before sampling due to limited shelf life.
Supplier - Millipore Cost - $10
Part No- MAKP037 Six 0.8 um MCEF Filters Purpose" Sampling Lead, Asbestos, Metals, Sulfuric Acid Mist
Supplier - Clayton Cost - $50
Purpose
3 Pre-weighed PVC Filters Sampling for Total Dust
Supplier - Kodak or Polaroid Cost - Approx. $50
Purpose
Instant Photo Camera Document conditions of sampling.
will by handing out photos
Employee good
LLA 001503
Supplier - Bacharach Cost - $1,200
Part No. Purpose
23-7350 TLV Sniffer
23-7230 Battery Charger 23-7243 Hose Assembly Sampling screening device for wide variety of compounds for manholes, indoor air pollution, battery hydrogen.
Supplier -
Cost - $10
Purpose
6 Gauze Pads 10 oz. Vial Hexane Wipe Sampling for PCB contamination
Purpose
4 Quarter Collection Tube Bulk sampling for asbestos
Supplier -
Cost - $100
Purpose
Foam-lined case 350 in2 x 6 in deep Case to contain above equipment with foam cut-outs to hold items in space and to store manuals.
LLA 0015C4