Document K6ZmDbDbkYayKxrNxQ0eGYqqX

i i Ii: I ! i i! V L. * ' . +10*1 Xml ***-"' The Finding of Chlorinated Dibenzofurans in a Japanese Polychlorinated Diphenyl Sample by John A. G. Roach and Irwin H. I'omehantz Dirision of C.hrmiotd Torhnolopy Food nnd. Drop: .iilrnini'itration Washington, D.C. 20204 The presence of tetra- andpentachlorinated dibenzofurans and hexa- and heptachlorinated naphthalenes in two samples of polychlorinated biphenyl mixtures (PCB) of European origin has been reported by VOS et al. (1970a). Their interest in a content analysis of the two PCB samples for impurities vas stimulated by previous work in which toxic effects observed in chicks were attributed to these two samples (VOS et al., 1970b). Kanechlor 400 (KC-400), a commercial PCB preparation of Japanese origin, has been identified as the causative agent of Yusho, a human poisoning incident resulting from the ingestion of rice oil contaminated with KC-400 (KURATSUNE et al., 197Z). We have analyzed a sample of KC-400 made available to us from the Kanegafuchi Chemical Industrial Co., Ltd. through Dr. H. Blumenthal of the Food and Drug Administration to determine whether potentially hazardous chemicals, particularly chlorinated dibenzofurans (Cl-DBF), were present as contaminants. It was the objective of this analysis to obtain, where possible, structural information on these contaminants and 'an estimate of their con centration in the KC-400. Experimental A hexane solution of the KC-400 was gas chromatographed, using an electron capture detector, on a column of 80-100 mesh Chromosorb WHP coated with 107. DC-200 and on a column of 157. QF-1 and 107. DC-200 each coated separately on 80-100 mesh Chromosorb WHP and mixed in a 1:1 weight ratio. Hie KC-400 (chlorine content 48%) showed only minor differences in peak locations and relative peak heights from Aroclor 1248 (chlorine content 487.), a PCB of American manufacture. Therefore, Aroclor 1248 to which a reference mixture of di-, tri- and tetrachlorinated dibenzofurans (prepared by chlorination of dibenzofuran in tetrachloroethylene with iron powder as catalyst) had been added, was used by Porter to devise a procedure to separate Cl-DBF from PCB (PORTER, 1971b). This procedure, as used in the present study, is outlined in Figure 1. he. de is he: coi Te: eli mit etl the int the exa of fro 10 meti cen 338 Rullrlin ol KnvimnmcnlM Contamination & T<>iicolocy. Vol. 12, No. 3 J974 by Springrr-VcrUg New York Inc. DSVV 338664 /. STLCOPCB4082403 KC-400 in hexane solution Florisil Column /\ PCB in eluate A (discard) Cl-DBF in eluate B / Alumina Micro Column (PORTER, 1971a) \ PCB in eluate 1 (discard) Cl-DBF in eluate 2 Figure 1. Procedure for Separation of Chlorinated Dibenzofurans from Chlorinated Biphenyls in KC-400 . The Florisil (8 g of 60-100 mesh PR grade) was activated by heating at 130C > 12 hr and cooled to room temperature in a desiccator. Before the sample was added to the column, the Flor isil column was prewashed with about 25 ml hexane. The KC-400/ hexane solution (K 2 ml) was placed on the Florisil, which was contained in a 10 mm i.d. x 300 mm glass column fitted with a Teflon stopcock and medium porosity fritted disk. The column was eluted with two eluants in succession at the rate of about 5 ml/ min. Eluant A was 150 ml hexane. Eluant B was 100 ml 57. ethyl ether in hexane. Eluate B was concentrated to about 1 ml before the sample was placed on the alumina micro column. The micro column was a disposable pipet of roughly 5 mm bore into which a small wad of glass wool had been inserted to retain the aluminum oxide. Merck alumina, which had been heat-activated exactly like the Florisil, was poured into the column to a depth of 2.5 cm. Sample or eluting solvent was then added to the column from a disposable pipet or a large glass syringe. Eluant 1 was 10 ml 1% methylene chloride in hexane; eluant 2 was 6 ml 20% methylene chloride in hexane. Additional PCB was removed by con centrating eluate 2 to about 1 ml and subjecting it to a second 339 DSW 338665 I i i ? i i V . 1 t \ alumina micro column cleanup, simply repeating the alumina column procedure. This procedure was first applied to duplicate 2 mg portions of KC-400. Electron capture gas chromatography of eluate 2 showed a gas chromatographic peak in each sample that had a relative retention time matching that of a tetrachlorodibenzofuran on both a 104 0V-101 and a 1:1 104 DC-200 + 157. QF-1 column under the following conditions: glass column, 6 ft. x 4 mm id., column temperature 200C, injection temperature 225C; carrier gas, nitrogen at 120 ml/min.; detector, tritium source (concentric type), operated in electron capture mode at 210C. Detector voltage was adjusted so that 1 ng heptachlor epoxide causes 1/2 full scale recorder deflection at 1 x 10'^ AFS. The reference material for this retention time comparison was the tetrachlorodibenzofuran component in the mixture of chlorin ated dibenzofurans. To obtain sufficient material from the KC-400 for combined gas chromatography/mass spectrometry (GC/MS) analysis, the pro cedure was scaled up to permit cleanup of 8 mg portions of KC-400. Cleaned up eluates (eluate 2) were then combined to give two composite samples, each equivalent to approximately 100 mg KC-400. These two composites were analyzed by GC/MS (Finnigan 1015 quadrupole mass spectrometer) and the resulting data were examined for evidence of the presence of compounds that were not chlorobiphenyls. A reagent blank of equivalent size was also analyzed by GC/MS. The reagent blank contained none.of the compounds found in the samples. The qualitative results of the KC-400 analyses are summarized in Table 1. The identification of the compounds listed in Table 1 was based on a comparison of the mass spectra of the sample compounds with the mass spectra of the di-, tri-, and tetrachlorinated dibenzofuran components in the reference mixture and on comparison with mass spectral data on chlorinated dibenzofurans in the published literature (VOS et al., 1970a; FIRESTONE et al., 1972; PLIMMER et al., 1973). The amount of tetrachlorodibenzofuran contained in the reference mixture was approximated by comparing its microcoulometric GC response with the response given by a known quantity of a tetrachlorodibenzodioxin of known structure. The tetrachlorodibenzodioxin was considered an appropriate microcoulometric reference compound because of its structural similarity to tetrachlorodibenzofuran. The electron capture GC responses of the tetrachloro component in the synthetic mixture and in the KC-400 extracts were then compared to quantitate the tetrachlorodibenzo furan in the KC-400. The KC-400 was estimated to contain approximately 1 ppm tetrachlorodibenzofuran. 340 DSW 338666 STLCOPCB4082405 due MOTnHrtgwrmtigixttBi ::ji TABLE 1 Compounds Present in Kanechlor 400 After Cleanups red Mass (No. of Cl) and Molecular Weight Fragmentation Data Compound Present of Compound -fc 25<3 (3C1) ;M-2C1 trichlorobiphenyl 256 270(3C1);M-(CO+C1) trichlorodibenzofuran 270 ( 290(4C1);M-2C1 tetrachlorobiphenyl 290 298(5C1);M-2C1 pentachloronaphthalene 298 304(4C1);M-(C0+C1), M-(C0+3C1) tetrachlorodibenzofuran 304 I 312(5C1);M-Cl unidentified; perhaps me thy1pentachloro naphthalene or pentachlorophenyl cyclopentadiene 312 338(4 or 5C1); M-(C0+3C1) indi- cated . possible pentachlorodibenzofuran 338 j --Listed in order of elution from 3% OV-101, 6 ft. x 2 mm i.d. glass column at 220C, carrier flow 20 ml He/min.; the same MS evidence was found in both samples examined for all entries but the last (possible pentachlorodibenzofuran) for which a second determination was not attempted. Summary Chlorinated dibenzofurans, including 1 ppm of tetrachlorinated dibenzofuran(s), and pentachloronaphthalene have been identified by combined gas chromatography/mass spectrometry in a polychlori nated biphenyl of Japanese manufacture (KC-400). The question of whether chlorinated dibenzofurans in KC-400 may have contributed to the reported Yusho incident is thus raised. Acknowledgement The authors wish to thank Sandra Mercier for assistance in the preparation of the samples for GC/MS analysis. The reference mixture of di-, tri-, and tetrachlorinated dibenzofurans was kindly provided by Dr. Albert Pohland, Food and Drug Administration. References FIRESTONE, D. , J. RESS, N. L. BROWN, R. P. BARRON, and J. N. DAMICO; J. Ass. Offic. Anal. Cliem. 55_, 85 (1972). 341 dSnN 338667 STLCOPCB4082406 I f* fv i < s i t KURATSUNE, M., T. YOSHIMURA, J. MATSUZAKA, and A. YAMAGUCIII: Environ. Health Perspect. Issue No. 1, 119 (1972). PLIMMER, J. R., J. M. RUTH, and E. A. WOOLSON: J. Agr. Food Chern. 21, 90 (1973). PORTER, H. and J. A. BURKE: J. Ass. Offic. Anal. Chem. 54, 1426 (1971a). PORTER, M.: Private Communication (Feb., 1971b). VOS, J. G., J. H. KOEMAN, H. L. VAN DER MAAS, M. C. TEN NOEVER DE BRAUW, and R. H. DE VOS: Fd. Cosmet. Toxicol. 8, 625 (1970a). VOS, J. G. and J. H. KOEMAN: Toxicol. Appl. Pharmacol. 17, 656 (1970b). -s. v; 342 DSW 338668 STLCOPCB4082407