Document K6OxXOQzxJyw60b8x83gDEvEr
Heating Systems stMm
Barnes clones
129 Brookside Avenue
Boston, Mass.
New York Office: 101 Park Avenue
Barnes & Jones Vapor and Vacuum Systems of Steam Heating; Modulation
Valves; Adjustable-Orifice Radiator Valves; Packless Quick-Opening Radiator
Valves; Thermostatic Radiator Traps; Thermostatic Trap Replacement Units;
Condensators (Boiler Return Traps); Float and Thermostatic Traps; Strainers;
Damper Regulators; Gages; Systems of Zone Control for Steam Heating.
Complete Catalog on Request
Modulation Valves, Type K--Packless Quick Opening Valves, Type F
Types K and F Valves have nontarnishable indicat ing dial, non-rising stem, renewable disc seat. Tailpiece extra heavy. Extra long to facilitate installation. Three models: lever handle, wheel handle, lock shield. Type F Valve furnished with wheel handle only.
Thermostatic Radiator Traps
Sturdily made to precision standards. Sensitive in opera tion. Provide in stant discharge of air and water, pre vents passage of steam. Contains unique Cage Type Thermostatic Unit, which carries its own thermostatic element, valve piece and valve seat, factory cali brated and locked in correct adjustment.
Type K Valve
vsSize........................
vs
Cap.Sq Ft Rad.*... 30
60
r
100
>VS 180
Trap No.................... 120 12 123 124 134 13 14
vsInlet Tapping...........
Outlet Tapping......... t
vvss
yvss
vvss
vvss
1* 1*
Cap. Sq Ft Rad.*___
200 400 400 400 700 1200
Type F Valve
VS vs vs w 2*Size.....................................
\" 1
Cap. Sq Ft Rad.*............ 30 60 100 180 270 400
*Based on 2 oz pressure differential.
Adjustable Orifice Valves, Type H
toi -; -
May be adjusted for different capacities after installation. At all times provides in dication of the adjust ment. Operation is
quiet. Unauthorized tampering with ad justment is virtually impossible.
tions, air binding, the return side.
Condensators
For returning water of condensation tq boiler from open re turn line systems independently of boiler pressure, without change in operating condiadmitting steam to
No............................... 31 32 33 34 ! 35 36 Cap. Sq Ft Rad.*.... 700 1600 3300 6000| 10.000 16.000
Based on 1^ lb pressure differential.
Thermostatic Radiator Cage Replacement Units
Offer complete and reliable trap re newal in practically every make of ther mostatic trap. You simply (1) remove the old cover and unit, (2) insert the new Barnes & Jones Cage Unit, (3) re place the cover, and the old trap will oper ate with its original efficiency.
Float and Thermostatic Traps
Handle large and sudden condensation loads. Large air and watercapacity. Large fibat assures instant opening of the dis charge valve. Cage Type Thermostatic Unit assures quick elimination of air.
Trap No......... 41 42 43 43A i 44B 45B
vsInlet Tapping. vs.Outlet Tapping
\" \"
1 1
vvss
llvVsS
;
i vs
<VS
22m"
Cap. Lb. Water
per Hour*... 200 700 1200 1200 2400 3000
Based on 2 lb pressure differential.
968
Heating Systems Hot water
Bell and Gossett Company
3000 Wallace Street
Chicago, 111.
HOT WATER SYSTEMS AND SPECIALTIES
B & G MONOFLO HEATING SYSTEMS
A genuine advance in con trolled and economical heat ing is offered by the B & G Monoflo System. In conjunction with forced circulation, the B & G Monoflo Fitting makes possible a thoroughly practical, well balanced single main hot water instal lation. In over 40,000 installations, the B & G Monoflo System has demonstrated its desirability in homes, apartments, factories and institutional build ings. The equipment lends itself ideally to zoning, yet is exceedingly simple in application.
equipment required
B & G Booster
An electricallydriven centrifugal pump, which me chanically circulates hot water through the system --distin guished by genuine oil
lubrication, patented water-tight seal and precision
manufacture throughout.
B & G Indirect Water Heater
Any one of five B & G Heater types can be in stalled to furnish year around do mestic hot water at smallest pos sible cost.
B & G Angle Flo-Control
Valve
This valve, in
stalled in the
main, controls circulation of hot water to radia tors, permitting summer opera tion of the In direct Water
Heater. It also helps maintain a uniform room temperature during
the heating season.
B & G Monoflo Fitting
A correctly engineered fit ting, installed in the main at radiator connections, which di verts water into the radiators. Its design assures a balanced distribution of water, without introducing excessive resist
ance.
Simplex Relief Valve
For boiler protection.
See the B & G Handbook for Complete Engineering Data
969
VI