Document K6KnZOGkkv4yvaGJJ0XvyKzEN
Inter Ollice
Jl?l 9 22W'01
SAFETY4 SECURITY
Personnel and Organization 6taff
January 7, 1981
II. R. domett, Manager Arizona Proving Ground
CO T.'LtPc '/ D. J. Sherman, M.D
Subject: Industrial Hygiene Survey - Asbestos Fibers Arizona Proving Ground
At your request an industrial hygiene survey was performed at the subject lcc&tion. The purpose was to evaluate employe exposures to airborne asbestos fibers at the brake replacement operation and thermocouple drilling operation.
The results of representative breathing zone samples at both operations indi cate that no detectable exposures to asbestos vere found. Additionally! the results of the analysis of a bulk sample of brake lining dust revealed no detectable asbestos content.
Based on the above results* it is concluded that no apparent health hazard existed. Since the detectable limit of the samples was less than the Ford Motor Company guideline for medical monitoring of 0.1 fibers per cubic centi meter, no such monitoring is required. Notwithstanding the above, all as bestos containing waste (i.e. drilling dust) should be collected and dis posed of in sealed impermeable bags or other impermeable containers in accordance with the OSHA Asbestos Standard (29CFR 1910.1000(h)(2)).
If there are any questions, contact the writer at 33-76955
Attachment at
M. O'Brien Senior Industrial Hygienist Industrial Hygiene and Toxicology Dept Employe Health Services
SCF-FORD-3020 8004 1173
\*
INDUSTRIAL HYGIENE SERVICES SECTION INDUSTRIAL HYGIENE AND TOXICOLOGY DEPARTMENT
EMPLOYE HEALTH SERVICES
ARIZONA PROVING GROUNDS
September 30 and October 1, 1980
Asbestos Use Arena
PERMISSIBLE OCCUPATIONAL EXPOSURE LIMIT TO AIRBORNE CONTAMINANTS
(f/ce = fibers per cubic centimeter of breathing zone air)
Contaminant
6-Hour Time Weighted
Average Exposure Limit
Asbestos
2 f/cc
RESULTS
Employe Name/Date
SS. Number
Sample Time (Min.)
Airborne Asbestos Concentration (f/cc/
I. Brake Shoe Replacement
V. W. Misell 9/30
421-16-9561
53 52
1 52
52
Time Weighted Average Exposure
N.D.1 1
N.D/
N.D.1
N.D.1 N.D.1
II. Thermocouple Drilling
V. A. Beezley
10/1
526-26-1920
23 23
Time Weighted Average Exposure
N.D.2 N.D.2 N.D.2
N.D.i = None detected at 0.03 f/co N.D. - None detected at 0.06 f/cc
DATA RETRIEVAL NUMBERS! MJO 2110-2115
EQUIPMENT: Bendix BDX-44 personal sampling pumps and open-fac6d 0.8 u AA filters
ANALYSIS:
Personal samples analysed using phase contrast microscopy by Cleyton Environmental Consultants, Inc.
Bulk sample analyzed by polarized light microscopy by Clayton Environmental Consultants, Inc.
6004 1174