Document K6BxYpe7Xapv47gGx5qM145gr

TENNE 0 0NTER-OF Flea MEMO CHEMICALS j INC. TO F ROM Subject G. I. Rozand At Piscataway J, T,, Sweeney At Flemington Bendix VCM Monitoring Data Analysis Flemington Plant October 25, 1975 to November 7, 1975 Date November 17, 1975 Copy to W,, De Bord D. M, Hershkowitz P,, A0 Lobo W. Miringoff F. X. Ritter M,, K0 Rosen Po R,, Scarito F. Toea W. F. Gabel Attached is the subject analysis. 010040 ! Bendix Monitoring Data Analysis Flemington Plant October 25, 1975 - November 7, 1975 Readings (PPM VCM) 'oint No. RE-1 RE-2 RE-3 Point Location Center Aisle, First Floor Remarks; Problem is believed to be the result of reactor washouts - washing frequency has been reduced by 50%. Total 972 >5 >25 43 RE-4 RE -5 RE-6 No, 1 and 2 Slurry Pumps, First Floor Remarks: Problem is believed to be the result of chip basket washouts more data is being generated. 972 45 RE-/ RE-8 Recovery Compressor Room Remark; Intermittent leaks in vacuum pump and compressor systems. 648 33 "1 Center Aisle, Second Floor, ) RE-13] RE-12 Remarks; General ventilation problem related to reactor ventilation, reactor washout and vent condenser discharge. Engineering estimate is now being pre pared covering relocation of reactor ventilation. Vent condenser discharge has been reloated, data being generated. 976 40 RE-12 RE -1RE-It Stripper Platform, Panel board area Second Floor Remarks; General ventilation problem as for RE-10, RE-11, RE-12 56 RE-If Knock-out Tanks, Second Floor Remarks: No defined source as yet. 326 25 >100 01 0041 Bendix'Monitoring Data Analysis Flemington Plant October 25, 1975 - Novembe.r 7, 1975 Readings (PPM VCM) 'oint No. PP-2 PP-3 PP-4 PP-5 PP-7 PP-8 PP-9 PP-1C P^6 Bendix Monitoring Data Analysis Flemington Plant October 25, 1975 - November 7, 1975 Readings (PPM VCM) Point Location PILOT PLANT ARKA Effluent Lift Pump Area Remarks: Not a work area - does not represent personnel exposure. Total 314 >5 >25 25 6 Pilot Plant Remarks: Engineering actively engagec in preparing an overall scope package for a CAR 2198 205 20 Parshall Flume Well Remarks: Not a work area - does not represent personnel exposure. i / * 314 28 8 >100 0 1 0 W.DC Bord * 01 )043