Readings (PPM VCM)
'oint No.
RE-1 RE-2 RE-3
Point Location Center Aisle, First Floor
Remarks; Problem is believed to be the result of reactor washouts - washing frequency has been reduced by 50%.
Total 972
>5 >25 43
RE-4 RE -5 RE-6
No, 1 and 2 Slurry Pumps, First Floor
Remarks: Problem is believed to be the result of chip basket washouts more data is being generated.
972
45
RE-/ RE-8
Recovery Compressor Room
Remark; Intermittent leaks in vacuum pump and compressor systems.
648
33
"1 Center Aisle, Second Floor, )
RE-13] RE-12 Remarks; General ventilation problem
related to reactor ventilation, reactor washout and vent condenser discharge. Engineering estimate is now being pre
pared covering relocation of reactor ventilation. Vent condenser discharge
has been reloated, data being generated.
976
40
RE-12 RE -1RE-It
Stripper Platform, Panel board area Second Floor
Remarks; General ventilation problem as for RE-10, RE-11, RE-12
56
RE-If Knock-out Tanks, Second Floor Remarks: No defined source as yet.
326
25
>100
01 0041
Bendix'Monitoring Data Analysis
Flemington Plant
October 25, 1975 - Novembe.r 7, 1975
Readings (PPM VCM)
'oint No.
PP-2
PP-3 PP-4 PP-5 PP-7 PP-8 PP-9 PP-1C
P^6
Bendix Monitoring Data Analysis
Flemington Plant
October 25, 1975 - November 7, 1975 Readings (PPM VCM)
Point Location
PILOT PLANT ARKA Effluent Lift Pump Area Remarks: Not a work area - does not represent personnel exposure.
Total 314
>5 >25 25 6
Pilot Plant
Remarks: Engineering actively engagec in preparing an overall scope package for a CAR
2198
205 20
Parshall Flume Well
Remarks: Not a work area - does not represent personnel exposure.
i /
*
314
28 8
>100 0 1
0
W.DC Bord *
01 )043