5 \ SUN PETROLEUM PRODUCTS COMPANY A Division o* Sun Oil Company ot Pennsylvania *$UH0C3> October 10 , 1980 Mr. Bill Gill Compliance Division Texas Air Control Board 6330 Highway 290 East Austin, Texas 78723 LC^ ^ 1 PLAINTIFF'S | EXHIBIT I KRC-64 Dear Mr. Gill: Please accept this letter as our instrument of notification of intent to remove friable asbestos as mandated by 40 CFR 61.22 paragraph d. I have spoken with Tom Palmer about this job and he informed me that a letter of intent should be sent to your office. 1 also requested permission to start this job as soon as possi ble. Mr. Palmer gave an o.k. to this request. OWNER OPERATOR JOB DESCRIPTION Sun Petroleum Products Company a Division of Sun Oil Company of Pennsylvanr.i a -Corpus Chrjsti Refinery MAILING ADDRESS . P.O. Box 2608 Corpus Christi, Texas 78403 PHYSICAL LOCATION Off Interstate 37 at Suntide Road, 7 miles Northwest of Corpus Christi JOB A jOB DESCRIPTION Demolition and removal of asbestos insulated .deaerating vessels - BG652 and BG653 at the Boiler House unit. The material to be re moved is blocked asbestos insulation. The towers are identical in size and shape being 22.5 feet from tangent to tangent and 12.5 feet in diameter. The caps are approximately cone i a! in shape with diameters of 12.5 feet and heights of 3.75 and 7 feet. This repre sents approximately 1213.5 square feet of in sulation per vessel for a total of 2427 square feet total insulation removal. This insulating material is 20 to 25 years old. These vessels were used as water deaerators until about 1978. At that time the vessels were removed from ser vice and have been idle since that time. Some associated asbestos covered piping will be strip ped and removed at the same time. P.C. BOX 230c. CORPUS CHRIST:. TEXAS 75402 (512) 241-4511 KOI8478 J OB' DE SCR 1PTION CON'T 'l JOB LOCATION START-FINISH DATE REMOVAL METHOD 1 1QB S Di $nu.ntl e and remove asbestos blocked in sulation from discarded catalytic'cracking vessel DC 101. This vessel is approximately 65 feet from tangent to tangent with a 15 foot diameter. This represents surface area of approximately 2900 square feet (minus 160 square feet for manways and other openings.) In addition one section is asbestos covered on the inside. This section is approximately 20 feet by 15 foot diameter. This represents about 866 square feet of additional insulation. One cap is shaped like a truncated cone with the large diameter at 15 feet and the small diameter at 2.5 feet. The cone sides are angled at 30. The area of this section is calculated to be about 260 square feet. Be cause the top section is very difficult to measure we estimate the area to be about 140 square feet. All together the total amount of insulation to be removed on this vessel is approximately 4166 square feet. JOB_A Inside refinery limits of Sun Petroleum Products Company's Corpus Christ! Refinery at Boiler House unit. JOB_B Inside refinery limits of Sun Petroleum Products , Company's Corpus Christ! Refinery at scrap staging area. Start as soon as manpower becomes available we anticipate beginning about mid-October. Be cause this is not a priority job we would like to have our men work on the job when they are available. Therefore it is impossible to pre dict exact completion,. but we anticipate com pletion before the end of the year. Every effort will be ma de to restrict emis sion of fibers. Whenever we have to cut the in sulation we will wet down the surface. All asbestos scraps and insulation will be bagged KOI8479 JOB DESCRIPTION CON 'T DISPOSAL SITE Inimpermiable plastic sacks. Some removal will take place in the Boiler House unit and the remainder will take place in a re mote location near the flare stacks of the refinery. Sun Company employees will p r o vide the manpower to do t his job. All workers will be directed to exercise great care during all phases of this operation. Arrangements have been made with Texas Ecologists, Inc. (a licensed disposal facility) of Robstown, Texas to handle disposal of the sacks of asbestos containmented material. REPLACEMENT MATERIAL- No replacement is needed for these vessels The old vessels have not been in service for several years and are being removed but not replaced. If I can be of any further assistance please feel free to contact me at the address on the letterhead or by phone at (512) 241-4811, Ext. 271. Sincerely, WCM/ciw Cody Milburn Loss Control Supervisor cc: R. E. Fleming, J. R. Kampfhenkel, J. D. Johnson, J. H. Alston Tom Palmer Texas Air Control Board 5 60 2 Old Brownsville R d. Corpus Christi, Texas 78415 I KOI8480