Document K1ZE6k5DBOqdyKVRVGq3G00w
Union Carbide Agricultural Products Company, Inc*
Institute Plant
INDUSTRIAL HYGIENE SAMPLING RESULTS
TO:
Mr. G. F- Morris COPIES TO:
Mr. D. P. Egnor
Building: 23_________________________
Mr. D. K. Garrett
Institute Plant______________________
Mr. K. G. Harless Mr. R- L. MOSS______________
Mr. L. W, Youngblood
Purpose:
X____ Routine __________ Special Request
_________ Regulatory Agency Inspection
Sample Date(s):
November 13, 14, 19, & 20, 1986
Sample Location:
Millwright & Motor Valve Shops Department No.:
327
Process/Activity: Gasket Cutting_________________________________________
Contaminant: Asbestos Fibers
Exposure Limit:
OSHA 0.2 fibers/cc
(TWAq);-(TWA^)
ACGIH UCC
0.2 fibers/cc
(TWA,,); o
-
________________________(TWAg);"^TWA12^
_____(TWA,^) LZ.
Sample Type: ________ Personal
X Area
________ Source
Surface Wipe
________ Other (See comments)
Analytical Method:
Per 29 CFR 1910.1001, Appendix A
Results:See Comments
X See Attached Table
COMMENTS: Airborne asbestos fiber concentrations were measured at the Millwright Shop and Motor Valve Shop gasket cutting stations on the above dates. A sample pump and filter were positioned about two feet above the cutting surface (i.e., in the breathing zone) at each station on each sample date. The number of gaskets cut per day at the Millwright Shop ranged from four to about ten. However, no gaskets were cut on any of the days at the Motor Valve Shop. Consequently, only one of the filters for that location was actually submitted for analysis.
fcU393?
UCC 008970
Union Carbide Agricultural Products Company, Inc.
Institute Plant INDUSTRIAL HYGIENE SAMPLING RESULTS
The gasket cutting process at the Motor Valve Shop is the same as at the Millwright Shop. Asbestos-containing gasket material (eg, Garlock 900) is placed on the cutting board, the actual surface of which consists of the same gasket material. An extension gasket cutter (essentially an adjustable razor blade on a pivot arm) is then used to manually cut a circular gasket. Occasionally a punch is used to produce the center holes in the gaskets though most are produced with the extension cutter. Shop employees cut their own gaskets as they need them. There is no one person designated to do this work.
The cutting stations are located on bench tops in the two shops. There are no engineering controls or special work practices in place at these stations to minimize fiber generation and/or dispersion. However, fiber generation is minimized by the fact that the fibers are bonded in the gasket material.
All of the monitoring results were extremely low and indicate that the gasket cutting activities do not pose a hazard to personnel in the shops. The minor variations among the results are negligible and may be due to the sampling and analytical procedures. The monitoring results for the Millwright Shop (which encompassed actual gasket cutting) are considered to be applicable to the Motor Valve Shop since the materials, equipment, procedures, etc., are virtually identical at the two locations.
UCC 008971
OQ
Union Carbide Agricultural Products Company, Inc.
Institute Plant INDUSTRIAL HYGIENE SAMPLING RESULTS
Currently, no action is required except that the monitoring results must be reviewed with all affected employees (i.e.f all personnel who may at times cut gaskets or work in the vicinity of the cutting station). In lieu of reviewing these, copies of the results may be posted in the shops where they can be seen by all affected employees.
Report Date: NOTE :
January 19, 1987 Bldg. 2
Room: 172 Phone
PERSONAL SAMPLE RESULTS MUST BE DISCUSSED
WITH ALL AERECTED EMPLOYEES
6105
2187k
UCC 008972
Union Carbide Agricultural Products Company, Inc.
Institute Plant
INDUSTRIAL HYGIENE SAMPLING RESULTS
WORKPLACE LOCATION: Millwright & Motor Valve Shops
NAME(s) OF SAMPLER(s):J. L. Miller & H. C. Ries
CONTAMINANT: Asbestos
REPORT DATE: January 19, 1987
OSHA PEL: TWAg Q.2 f/cc ACGIH TLV: TWAq 0.2 f/cc UCC Guideline: TWAg
-
TWAi 9 ~
TWAi o ~
TWA12___ Z________
Sample Number
.-
W4767AA1Q435
Sample Da Le
11-13-86
W4766AA10434
W-4769AA10447
W4772AA10444
W4773AA10450
11-13-86 11-14-86 11-19-86 11-20-86
Sample Description
Motor Valve Shop
Two feet above gasket cutting table.
Millwriqht Shop
Two feet above gasket cutting table
Two feet above gasket cutting table.
Two feet above gasket cutting table.
Two feet above gasket cutting table.
Sample Time (min.)
Sample Results (f/cc)
420
0.006
426 402 377 383
<0-001 0.002 0.004 0.005
2187k
UCC 008973
AU399C