Document K1ZE6k5DBOqdyKVRVGq3G00w

Union Carbide Agricultural Products Company, Inc* Institute Plant INDUSTRIAL HYGIENE SAMPLING RESULTS TO: Mr. G. F- Morris COPIES TO: Mr. D. P. Egnor Building: 23_________________________ Mr. D. K. Garrett Institute Plant______________________ Mr. K. G. Harless Mr. R- L. MOSS______________ Mr. L. W, Youngblood Purpose: X____ Routine __________ Special Request _________ Regulatory Agency Inspection Sample Date(s): November 13, 14, 19, & 20, 1986 Sample Location: Millwright & Motor Valve Shops Department No.: 327 Process/Activity: Gasket Cutting_________________________________________ Contaminant: Asbestos Fibers Exposure Limit: OSHA 0.2 fibers/cc (TWAq);-(TWA^) ACGIH UCC 0.2 fibers/cc (TWA,,); o - ________________________(TWAg);"^TWA12^ _____(TWA,^) LZ. Sample Type: ________ Personal X Area ________ Source Surface Wipe ________ Other (See comments) Analytical Method: Per 29 CFR 1910.1001, Appendix A Results:See Comments X See Attached Table COMMENTS: Airborne asbestos fiber concentrations were measured at the Millwright Shop and Motor Valve Shop gasket cutting stations on the above dates. A sample pump and filter were positioned about two feet above the cutting surface (i.e., in the breathing zone) at each station on each sample date. The number of gaskets cut per day at the Millwright Shop ranged from four to about ten. However, no gaskets were cut on any of the days at the Motor Valve Shop. Consequently, only one of the filters for that location was actually submitted for analysis. fcU393? UCC 008970 Union Carbide Agricultural Products Company, Inc. Institute Plant INDUSTRIAL HYGIENE SAMPLING RESULTS The gasket cutting process at the Motor Valve Shop is the same as at the Millwright Shop. Asbestos-containing gasket material (eg, Garlock 900) is placed on the cutting board, the actual surface of which consists of the same gasket material. An extension gasket cutter (essentially an adjustable razor blade on a pivot arm) is then used to manually cut a circular gasket. Occasionally a punch is used to produce the center holes in the gaskets though most are produced with the extension cutter. Shop employees cut their own gaskets as they need them. There is no one person designated to do this work. The cutting stations are located on bench tops in the two shops. There are no engineering controls or special work practices in place at these stations to minimize fiber generation and/or dispersion. However, fiber generation is minimized by the fact that the fibers are bonded in the gasket material. All of the monitoring results were extremely low and indicate that the gasket cutting activities do not pose a hazard to personnel in the shops. The minor variations among the results are negligible and may be due to the sampling and analytical procedures. The monitoring results for the Millwright Shop (which encompassed actual gasket cutting) are considered to be applicable to the Motor Valve Shop since the materials, equipment, procedures, etc., are virtually identical at the two locations. UCC 008971 OQ Union Carbide Agricultural Products Company, Inc. Institute Plant INDUSTRIAL HYGIENE SAMPLING RESULTS Currently, no action is required except that the monitoring results must be reviewed with all affected employees (i.e.f all personnel who may at times cut gaskets or work in the vicinity of the cutting station). In lieu of reviewing these, copies of the results may be posted in the shops where they can be seen by all affected employees. Report Date: NOTE : January 19, 1987 Bldg. 2 Room: 172 Phone PERSONAL SAMPLE RESULTS MUST BE DISCUSSED WITH ALL AERECTED EMPLOYEES 6105 2187k UCC 008972 Union Carbide Agricultural Products Company, Inc. Institute Plant INDUSTRIAL HYGIENE SAMPLING RESULTS WORKPLACE LOCATION: Millwright & Motor Valve Shops NAME(s) OF SAMPLER(s):J. L. Miller & H. C. Ries CONTAMINANT: Asbestos REPORT DATE: January 19, 1987 OSHA PEL: TWAg Q.2 f/cc ACGIH TLV: TWAq 0.2 f/cc UCC Guideline: TWAg - TWAi 9 ~ TWAi o ~ TWA12___ Z________ Sample Number .- W4767AA1Q435 Sample Da Le 11-13-86 W4766AA10434 W-4769AA10447 W4772AA10444 W4773AA10450 11-13-86 11-14-86 11-19-86 11-20-86 Sample Description Motor Valve Shop Two feet above gasket cutting table. Millwriqht Shop Two feet above gasket cutting table Two feet above gasket cutting table. Two feet above gasket cutting table. Two feet above gasket cutting table. Sample Time (min.) Sample Results (f/cc) 420 0.006 426 402 377 383 <0-001 0.002 0.004 0.005 2187k UCC 008973 AU399C