Document Jy7Y5Q8zRQeV0LqYN0LB5jZv
:r"
murt
INTERNAL CORRESRONDEI-4CE &
J/tA S'. A ** d- / **' i
/>n/ r
m ourmm,.wt Ftmsset, c*iKmu
miAAf -sfca
Mr, W,C, Thurber Mining Metals 38th Floor New York
PT *
tv* February 10, 1975 ft**- Regional Vice President
Mhr W S*bf*ci
Dear Bill:
, ..
Last week I went to Sacrament and talked with' Bob
Monugan, president of California Manufacturers Association,
-concerning the matter of amendments to current asbestos legis-
lation, Monagan, incidentally, was the former speaker of the
Assembly in the California legislature and, more recently,
was Assistant Secretary of Transportation in the federal gov-
erament. He is well known and well respected as a legislator
and administrator.
'
I explained the circumstances' to Mr, Monsgan, and when it came to a question of sponsorship of the bill propose ing amendments, he said he saw no* reason why the CMA shouldn't sponsor it rather than Union Carbide of the Asbestos Informa tion Association, I indicated to him that we would .be happy to provide an expert or experts to testify-on this matter if it appeared'! be appropriate dr advisable, and that all we would need would be sufficient advance notice, I also assured him that we were not seeking any special advantage through this proposed legislation, and that we Would have the backing of other members of the asbestos industry so that we should not expect any opposition from that area,
- I will let you know as soon as I have heard from him about the action being taken.
Best regards,
NJ Hbarn/dp
*
.' .
.
*
-
REC^ivEP
i FB * p r--
UCC C Al- lt>JY i A
NIAGARA Taj i s. ffrY
F 1 % ^
UCC 010015
January 14, 1975
Mr. Norman J. Hearn Union Carbide Corporation One California Street San Francisco, California 94111
Dear Norm:
Furthar to our conversations on the California Act relating to the spraying of asbestos, I have enclosed for your discussions with CMA a draft letter docu menting the technical position of the asbestos industry in this matter and pro posed amendments to the recently enacted law requesting additional exemptions based upon demonstrably low levels of airborne asbestos dust.
The information contained in this letter basically represents the position of member companies in the Asbestos Information Associattorv/North America and, therefore, when this matter is formally submitted to the California Legislature it might possibly be under the aegis of AIA. However, I would request that you advise me an the best way to handle this matter.
You may wish to keep Mr. P. J. Gartly of Johns-Manvllle's Son Francisco office apprised on this matter. He is quite familiar with the background on initial legislation.
If you need anything further, please let me know.
Very truly yours.
WCT/es Enclosure
W. C. Thurber
bcc: Mr. R. H. Mereness Dr. H. B. Rhodes
P. S. You may also wish to get in touch with Wilson ** Flintcote, Los Angeles (213-583-3011). He was ( exemption on cold cut back asphalt added *
UCC 010016
Gentlemen:
Draft - January 8, 1975 .
Reference is made to California Senate Bill No. 2419 which was passed into law on
September 26, 1974. This act, which Is added to Chapter 10.3 commencing with Section 25910
of the Health and Safety Code, prohibits the spraying of any substance containing any amount
of asbestos after July 1, 1976, in or upon any building or other structure during its construction,
alteration or repair, with the exception of cold process cutback asphalt roof coatings. In ad
dition to the present statutory exemption of cold cutback asphalt roof coating, we believe that
there are other applications which should also be exempted from the statute. These proposed
additional exemptions will in no way jeopardize the health of the citizens of California and will,
at the same time, protect the employment of workers in the California asbestos and realted in
dustries.
'
The spraying of asbestos has received substantial publicity as a health hazard, primarily
as the result of extensive use of sprayed-on asbestos as a fire proofing and insulation material.
Industry has recognized that this practice which involved materials containing 10 to 80% asbestos
and little or no permanent binder was hazardous and accordingly it has been discontinued.
However, it is our firm belief that various materials containing small quantities of
asbestos can be applied safely by spraying with no significant hazard either to the occupational
worker or the general public and further that such spraying can be done in total compliance with
Section 5208 of the General Industry Safety Orders for the State of California dealing with as
bestos and the EPA National Emission Standards for Hazardous Air Pollutants. Those applications
which we propose for exemption generally involve the spraying of paints and coatings where
asbestos is a minor but important constituent added to give critical properties to the material.
These coatings are applied wet as a slurry or liquid thus precluding the generation of airborne
UCC 010017
(2)
asbestos fibers in excess of established California and Federal regulations. Specifically, we would propose that the following additional exemptions be added to the existing statute:
1. Water-based interior texture sprays containing as sprayed a maximum of 3% by weight of chrysotile asbestos and a minimum of 2% by weight of water-soluble starch, soya protein, polyvinyl alcohol, or equivalent binder.
2. Latex-based interior and exterior coatings containing as sprayed a maxi mum of 5% by weight of chrysotile asbestos and a minimum of 8% by weight of vinyl, acrylic, vinyl-acrylic, or equivalent polymer binder.
3. Resin-based laminating and/or coating materials containing as sprayed a maximum of 12% by weight of chrysotile asbestos and a minimum of 6%
by weight of polyester resin, alkyd resin, epoxy resin alone or in com bination with coal-tar, or an equivalent resin binder. 4. Asphaltic-based coatings containing as sprayed a maximum of 15% by weight of chrysotile asbestos and a minimum of 40% by weight of cutback asphalt or emulsified asphalt binder. , Supporting data from a variety of representative industrial operations in each class are provided in Tables I - IV. These data indicate that in no instance does the airborne con centration of asbestos fiber exceed either the time-weighted average or peak concentrations specified in Section 5208 of the General Safety Orders even for the lower level standard to be invoked on July 1, 1976. Exhibit 1 attached provides additional information relevant to this proposal. This information was excerpted from the Federal Register (v. 38 No. 66, April 6, 1973, p. 8821 8822) and is part of the EPA background information included with the promulgated National
UCC 010018
Emission Standards for Hazardous Air Pollutants. This material clearly indicates the undesir ability of and enforcement problems associated with an absolute ban on asbestos spraying.
Adding of these exemptions to the present statute will assure the continuing economic viability of those segments of the mining, milling, and formulating industries in volved with asbestos while protecting the health of the workers and the general public. We should further note that this proposed amendment is fully supported by the Asbestos Information Association/North America. This organization consists of twenty-two member companies and associations which represent three-quarters of the asbestos mining, milling, manufacturing and importing industries of the United States. The AIA/NA has worked closely with State and Federal agencies to develop sound safety and health regulations for the asbestos and related industries.
We would be pleased to further discuss this proposed amendment to Chapter 10.3 of the Health and Safety Code with you at any time.
UCC 010019
TABLE 1
HATER-BASED SYSTEMS WITH WATER-SOLUBLE BINDERS
Sample Designation
Coimereial AmIication
I - INTERIOR TEXTURE SPRAYS
12 Celling spray.
Oate 6/14/73
82 *
3
Vail spray.
35
38
Celling spray.
-
28 -
56 *
131
Hall spray.
-
102 . *
-
IU3 K-2
K-2
1-25
Celling Spray,
Wall spray.
10/3/74
Z-49 Z-54
Celling spray.
12/4/73
Binder
Approx-^
Imate Wt. 1 Asbestos
Spray Gun Tvpe
Operation
Sanple Time (Hin.l
Asbestos Airborne Concentration
(fibers/cc
Soya protein.
Starch.
*
m
M m
2 Air supported
2
2
t 2
i
i i 2
2
m 9 m
1 41
1
2.5
u
2.5
m
1 19
Operator applying celling spray to condominium apts.
Operator wiping Mils after ceiling spray.
Operator applying wall spray to condominium apts.
Operator carrying hose during wall spraying.
Operator spraying celling of condominium.
9
.B
Operator spraying walls of condominium.
_
71 68
51
34
14 15 15 21 12
Operator applying celling spray to home.
Operator "wiping" walls after ceiling spray.
Operator applying wall spray to home. Full coverage.
Operator spraying glitter. Immediately after ceiling sprayed.
19
22 24
26
Operator applying ceiling spray to condominium apts.
Operator "wiping* walls ifter ceiling spray.
20 24
0.1 0.1 0.3. 0.8 0.1 0.5 0.8 0.6 1.6 1.1 0.5 0.2 0.07 0.0
0.5 0.1
^ Based on total formulation as sprayed.
UCC 010020
r
I. Water-Based Systems with Water-Soluble Binders
Binders:
.
Type:
Starch, polyvinyl alcohol, soya protein, or equivalent.
Content: Typically 6-8% by weight of the dry formulation before mixing with water, 2-4% as sprayed.
Main Uses: Interior wall and ceiling texture sprays.
(Where texture is applied to walls it must be covered with at least one coat of a latex or oil-based paint.)
Asbestos Content: Up to 3% by weight of the total formulation as sprayed.
Supporting Data: Table I.
UCC 010021
ibie H
VATEP-BASEO systems WITH LATEX BINDERS
Sarrfte OeSlqnition
Comerctal Application
1 - EXTERIOR COATINGS
H-8 Wall and toof Spray.
J-3 M C-2 U
lt-13
Poof ipray.
Oate
10/A/7V ft II
9/30/71
Bidder
Vinyl latex. M
Acrylic latex Acrylic latex.
K-19
H 81 It
Approx-0)
Imate Wt. * Asbestos
Sorav Gun Type
3.7 Air supported. 2.8
0 to
0.7 AE rlesi.
0.7 i *
Operation
Sanple Time (Hln.)
Airborne Asbestos Concent rat ion (fibe rs /cc>v*l
Operator spraying vertical walT panel
i
15
12
8
Operator spraying downward onto a targe roof.
M
28 It
0.0 0.2 0.2 0.0
0.0
(1) Baiad on total formulation as ip rayed.
UCC 010022
II. Water-Based Systems with Latex Binders
Binders:
Type:
Vinyl latex, acrylic latex, vinyl-acrylic latex, or equivalent.
Content: Polymer content of 10-20% by weight as sprayed.
Main Uses: Exterior coatings for buildings and mobil homes, including roofs.
Asbestos Range: Up to 4% by weight of the total formulation as sprayed.
Supporting Data: Table II.
UCC 010023
Tflfllt II!
RESIN-PARED SYSTEMS
Sample Designation
Conmerctal Application
Pate
I - POLYESTER RESIfiS A. General Purpose laminating Resins
C9 Boat manufacture, 12/7/72
Binder
General purpose laminating resin.
1-13
* 10/31/74
*
A-28 N-30
A-34 A-40 . 1-12 '
10/8/74
.
.
Approx-O)
Inate Vt. X Asbestos
Spray Gun Tvpe
Operation
Sample Time
W",,-.!
Asbestos Airborne Concentration
itibers 'cc
0.5 Air-supported Operator spraying
chopper.
molds with resin
6 chopped gla'ss.
24 .
0.6
0.5
0.5 0.5
0.5 0.5 m 0.5 m
Operator spraying resin S cropped fiber glass. (Includes roll-out time.)
Operator spraying resin t cropped fiber glass.
Operator spraying resin t cnopped fiber glass.
Operator spraying mold with resin. (No glass-.)
16 5 4
55 53 35
0.1 0.4 0.4
0 0.03 0.1
B. Chemical Resistant Resins
J-21
fiber-glass pipe 8/13/74 manufacture.
H-26
Chemical resistant resin.
W
1.4 Airless.
t
1.4 m
Operator adjacent to automatic spray machine coating 28' mandrels.
Operator wiping mandrels. In area near spraying.
23 0.1 14 0.4
J-S
Ship coating.
10/3/74
Chemical
0.7 Air-supported Roll-out man. In
65 0.4
resistant
wand.
spraying area about
resin * chopped
1/4 of time.
fiber glass.
J-7
0.7
Operator spraying
41 0.4
ship hull In dry
dock.
K-28
*
0.7
23 0
0) Based on total formulation as sprayed.
UCC 010024
TABLE IM (continued) REStH BASEO SYSTEMS
Sample Designation
Commercial Aoolicaticn
II - EPOtY RESINS
A. Filled Epoxy
IC-S Ship coating.
K-10 H-10
1-27 J-l
Date
10/2/74
Binder
Approx-O)
(mate
A. 1
Asbestos
Spray Cun Type
Epoxy primei:
High build epoxy.
1.5 Airless.
1.5 .
0 Air supported*
0. 0
m
Operation
Operator spraying outside A under a Ship.
Operator spraying side of ship from scaffold.
Sample Time (Hln.l
Asbestos Airborne Concentrator (Fibers/cc
33 0.2 8 0.2
31 0.1 14 0.3 60 0.03
3. Epoxy - Coal Tar
H-45
Coating dry dock. 10/1/74
H-l
K-3
Coating pipe
M
Interiors.
III - AUYD RESIN PAINT
H-7 ' Painting
10/6/74
building exterior.
N-35
Epoxy Coal-tar, solvent.
1 1
1
Alkyd resin.
W
12 12
Airless.
Air-supported wand. .
Operator spraying side of dry dock from suspended platform.
Operator spraying
side of dry dock from fixed scaffold.
Operator spraying interior of 3", 6" and 12" diameter pipe.
Airless gun.
Operator spraying building exterior wail.
n
38 37
9
5
0.2 0
0.1
a
0.06
(1) Based on total formulation as sprayed.
UCC 010025
III. Resin-Based Systems
Binders:
Type:
Polyester resins, alkyd resins, epoxy resin alone or in combination with coal tar or equivalent resin.
Content: Range from~6% in zinc-rich primer to>49% for heavily filled alkyd to 99+ for polyester laminating resins.
Main Uses: Fiber glass reinforced boats, pipes, shower stalls, and similar articles.
Maintenance coatings for steel and concrete.
Intumescent and zinc-rich paint.
Exterior alkyd paints.
Asbestos Range: Up to 12% by weight of the total formulation as sprayed.
Supporting Data: Table III.
UCC 010026
TABLE IV
ASPHALTIC AMO COAL-TAR BASSO SYSTEHS
Sample Identl flcation
M-*2
(i-JI 2
2 3 3 -
m
Comnerclel Applicat I on
Date
Auto undercoating ,10/71* (Soind deadener)
M i
Fibrated Roof Coating,
9/26/7*
Binder Cut back asphalt
ii i
M
io/n/7*
14
II
9/26/7*
II
II
10/11/7*
14
Emulsified
12/18/74
asphalt fibrated
roof coating.
Steam refined, emulsified asphalt.
Approxirate Wt. i Asbestos
IS
15 8
8 8 8 3
3
Spray Cun Type Airless,
ii
At r supported .
it A!rless
it Air supported
Airless
Operation
Operator spraying on auto body.
ii
Operator spraying against vertical steel surface.
ii
m ii
II H
Operator spraying against vertical steel surface.
a
Sarrple Tine (Min.) 7
6 -
43
23
A! rbocne Asbestos Concentration (Fibers/cc>
0.2
1.5 0.02
O.ll 0.03 0*07 0.16
0.17
^ Based on total formulation as sprayed.
UCC 010027
IV. Asphaltic and Coal-Tar Based Systems
Binders:
Type:
Cutback and emulsified asphalt and coal-tar materials or equivalent.
Content: Typically^45X.
Main Uses: Automotive undercoating and sound deadener, roof coatings, foundation coatings.
Asbestos Content: Up to-15%.
Supporting Data: Table IV.
UCC 010028
txhlDlf i
Federal Register (v. 38 No. 66, April 6, 1973, p. 8821-8822)
The proposed standard would have prohibited the spraying of any material containing asbestos on any portion of .a building or structure, prohibited the spraying of any material containing as bestos in an area directly open to the atmosphere, and limited emissions from all other spraying of any material con taining asbestos to the amount which would be emitted if specified air-cleaning . equipment were used. Comments re ceived pointed out that this standard would: (1) Prohibit the use of materials . containing only the trace amounts of asbestos which occur in numerous nat ural substances. (2) prohibit the use of materials to which very small quantities of asbestos are added in order to enhance their effectiveness, and (3) prohibit the use of materials in which the asbestos is strongly bound and which would not gen erate particulate asbestos emissions. The promulgated standard applies to those uses- of spray-on asbestos materials which could generate major emissions of particulate asbestos material. For those spray-on materials used to insulate or fireproof buildings, structures, pipes, and conduits, the standard limits the asbestos content to no more than 1 percent. Ma terials currently used contain from 10to 80-percent asbestos. The intent of the 1-percent limit is to ban the use of ma terials which contain significant quantlties of asbestos, but to allow the use of materials which would: (1) Contain trace amounts of asbestos which occur in numerous natural substances, and (2) Include very small quantities of asbestos (less than 1 percent) added to enhance the material's effectiveness. Although a standardized reference method has not been developed to quantitatively deter mine the content of asbestos in a ma terial, there are acceptable methods available, based on electron microscopy, which independent laboratories have de veloped. Determining the asbestos con tent of a material with these methods costs approximately 3300, and the results are accurate within plus or .minus 50
l percent; these limits on accuracy were
taken into account in establishing the 1-percent limitation.
UCC 010029
UNION CARBIDE CORPORATION
270 PARK AVENUE, NEW YORK, N.Y. 10017
LAW DEPARTMENT
January 14, 1975
W.C. Thurber Mining & Metals 38th floor
Re: Mining & Metals California Act relating to the spraying of asbestos
Enclosed is the proposed change to the California Health & Safety Code, which I promised to send to you today.
If you have any questions, please do not hesitate to call.
VJZ/smm Enel.
Very truly yours,
"T Victor j/Zuypffv
UCC 010030
f (HIMHIASBESTOS
THE DISCOVERY COMPANY
UNION CARBIDE CORPORATION MINING & METALS DIVISION P.0. BOX 579 NIAGARA FALLS, N. Y. 14302 TEL: 716-278-3376
December 5, 1974
Mr. R. H. Mereness Executive Director
Asbestos Information Association/ 1660 L Street, N.W.
Suite 610 Washington, D.C. 20036
Dear Bob:
As agreed at our recent meeting, the spraying data to serve as the basis for proposed amendments to the Marks Bill have been compiled into four
broad categories and are attached. Bill Mortonson is planning to supplement his information with some data on emulsified asphalt-based materials and a spot has been left in Table IV to add this when you receive it. The JohnsManville account. Riverside Cement, has not provided their data and, at Ed Fenner's suggestion, we have not included their end use. It would not be difficult to add a category, "Water-Based Systems with Cement Binder" if they should come through with the information.
The data have been incorporated into a proposed draft of a letter to Senator Marks put together by Bill Thurber. Four exemptions are requested that
correspond to the four types of binder systems typified by the data. I did considerable thinking on the selection of the "right" words to define each system as broadly as possible and still have it acceptable and came to the conclusion that this depended largely on what the Senator wants. The definitions shown represent my opinion of definitions which are reasonable and can be defended effectively if this becomes necessary.
In essence, in each case the binder has been described broadly but a minimum binder level is also specified. This is coupled with a maximum
asbestos level. Individual end-use categorization has been avoided. Obviously, if discussions with Senator Marks indicate binder and asbestos level specifica tions are unnecessary, they can be dropped.
Copies of this have been sent to Ed Fenner arid Bill Mortonson for their comments and suggestions. It would be appreciated if they would also look at the data carefully to pick up any oversights. When you get the EPA problem temporarily out of the way, let's discuss this further.
Very truly yours.
HBR:cjb Attachments
CC: Messrs. E. M. Fenner W. H. Mortonson J. L. Myers W. C. Thurberv/
H. B. Rhodes Area Manager Marketing & Technology
RECEIVED OEC 9 1974
UCC 010031