Document JvrVdr25M8n2KOgKoDmQYoV3v
f /Jt" MujX
draft
DO NOT QUOTE OR CITE
DRAFT NERC/RTP POSITION PAPER
ON POLYCHLORINATED BIPHENYLS
(PCBs)
\
U. S. ENVIRONMENTAL PROTECTION AGENCY NATIONAL ENVIRONMENTAL RESEARCH CENTER RESEARCH TRIANGLE PARK, NORTH CAROLINA 27711
APRIL 1973
'
HONS 206171
NOTICE
DRAFT
DO NOT QUOTE OR CITE
NOTICES
This document is ft preliminary draft It has not been formally released by EPA and should not at this stage be construed to represent Agency policy. It Is being circulated for comment on its technical accuracy and policy implications.
MOWS 20bl?2
PREFACE
R DRAFT
DO NOT QUOTE OR CITE
This document was prepared by a Task Force convened under the
direction of
John F. Finklea, Director, National Environmental
Research Center (NERC). The objective was to review and evaluate the
current knowledge of polychlorinated biphenyls (PCBs) released into the
environment as related to possible deleterious effects upon human health
and welfare, with a view toward the preparation of a control strategy
document, should such be required, in consonance with the provisions
of the Clean Air Act as amended.
An extensive report prepared by an NIH Panel on Hazardous Trace
Substances, chaired by Norton Nelson, served as a primary reference for
the position paper. The report entitled "Polychlorinated Biphenyls -
Environmental Impact," was published in Environmental Research, Vol. 5,
No. 3, dated September 1972. Very recent data and information on PCB's
In the marine environment were generously provided by Patrick L. Parker,
Office of International Decade of Ocean Exploration (IDOE), NSF; and
George R. Harvey, Woods Hole Oceanographic Institution.
The following members served on the NERC Task Force:
James R. Smith
Eugene Sawlckl
W. Gene Tucker
Fred H. Haynie
Steve Bursian
J. H. B. Garner
. Robert G. Lewis
Donald H. Swanson
Douglas Worf
Roy L. Bennett
Anthony Zavadil
Marcia C. Dodge
-
,, James B. Upham
HONS 206173
*r.vro
ATT N or
U*>CT:
Wi
ENVIRONMENTAL PROTECTION AGENCY National Environmental Research Center Research Triangle Park. North Carolina 27711
James R. Smith, Chairman PCBs Position Paper
May 11, 1973
All Task Force Members (See Distribution)
Attached Is a copy of our Position Paper. Copies are being sent to Dr. Wiser, ORM, for review. If you have further corrections or changes, we can incorporate them during the review of ORM. Please submit changes to me by 23 May.
Thank you for your cooperation.
James' tf. Smith / Chairman
Attachment
Distribution:
James R. Smith
Eugene Sawlckl
W. Gene Tucker
Fred H. Haynie
Steve Burslan
J.H.B. Garner
Robert G. Lewis
Donald H. Swanson
Douglas Worf
Roy L. Bennett
Anthony Zavadll
Marcia C. Oodge
James B. Upham
John D Crenshaw-Observer
Or. Hueter
HONS 206174
TABLE OF CONTENTS
PREFACE SUMMARY, CONCLUSIONS AND RECOMMENDATIONS
A. Summary
B. Conclusions C. Recommendations
I. INTRODUCTION
.
II. REVIEW OF SAMPLING AND ANALYTICAL TECHNIQUES.
A. Introduction
1. Structures
2. Intercalibration and Standardization 3. Contamination
4. Precursors 5. Artifact Formation 6. Stability B. General Methods
1. Standards
2. Contamination 3. Sampling
4. Interfacing - Sampling and Separation
5. Separation
6. Analysis
C. A1 r
D. Water
E. Soil
*
. Food and Biological Tissues 1. Introduction 2. Isolation, Cleanup and Analysis
a. Pesticides Residue Analysis
b. Separation of PCbs from Pesticides
. 3.
QFouoadsntification
4. Animal Tissue
5. Plant Tissues 6. Human Tissues and Fluids
G. Source Sampling and Measurements
M. References
`
III. A, 1. 2.
a.
b.
3. 4. 8.
1.
2. 3* C.
D.
ENVIRONMENTAL APPRAISAL Environmental Sources and Physical Effects Sources Gross Loss Estimates
Annual Loss Estimates Cumulative. Loss Estimates
Future Losses Physical Effects Concentrations Air
Water 3011 Transport and Modeling References
'***
' M0NS '
206175 .
DRAFT
DO NOT QUOTE OR CITE
IV. - BIOLOGICAL EFFECTS
A, Human Health
1. -Introduction and Summary
2. Exposure to PC8s
a. Food
b. Air
3. Absorption
'
4. Latent Effects - Acute Exposure
B. Animal Toxicity
'
1. Acute Lethal Toxicity
2. Subacute Lethal Toxicity
3. Signs of Toxicity
4. Pathological Findings
5. Reproductive Effects
6. Toxic Interactions
7. Toxicity as a Function of the Degree of Chlorination
C, Ecological Effects
D. References
V. CONTROL TECHNOLOGY
-
A. Background
1. Production and Uses of PCBs
1. Sources of PCB Losses to the Environment
B. Emissions Control Alteratives
1. Manufacture of PCBs
2. Shipment and Transfer of PCBs
3. Manufacture and Use of PCB-contailing Products
4. Incineration of Waste PCBs 5. Sewage and Sewage Treatment 6. Solid Waste Disposal In Open Dumps 7. Solid Waste Disposal by landfill
8. Solid Waste Disposal by Incineration C. Summary D. References
VI. CURRENT RESEARCH ACTIVITIES
HONS 206176
DO NOT QUOTE OR CITE
SUMMARY, CONCLUSIONS, AND RECOMMENDATIONS A. Background Summary " ` Polychlorinated biphenyls (PCBs) have been shown to be toxic; however, the degree of toxicity appears to vary significantly among compounds. Some are highly toxic and others appear to be non-toxic. Some of the chemicals have been found to be contaminated with chlorinated dibenzofurans and chlorinated.dlbenzodioxlns -- both of which are known to be highly toxic. Severe cases of chloracne and acute liver disease have been associated with occupational or accidental exposure to nigh concentrations of PCBs -- either via Inhalation, contact, or ingestion with food. Biological experiments have produced similar results. The most serious Incident occurred in Japan in 1968 as a result of large-scale contamination of cooking oil. There is an increasing body of evidence that PCBs, which are now widely distributed in the environment, have had a deleterious effect upon certain biological species. Particular attention has been devoted to birds and fish. '
Polychlorinated biphenyls are a class of synthetic pollutants which have no known counterpart in the natural environment. The PCBs are manufactured by the chlorination of biphenyl with anhydrous chlorine using iron filings or ferric chloride as a catalyst. Two hundred and ten different chlorine-substituted biphenyls are possible, but the number observed in cocmercial formulations is much less. In their industrial applications, PCBs are relatively inert, stable chemicals with special dielectric properties. The higher-chlorinated species are nonflammable and have extremely low volatilities. Unfortunately, some of the characteristics which make PCBs so versatile in industrial
HONS 206177
DRAFT
DO NOT QUOTE OB DTE
applications also make them highly persistant in the environment.
PCBs were first produced commercially in 1929. They have since HKV*
been used in many industrial products. The principal applications
iwtole: 1) non-flammable hydraulic and lubricating fluids, 2) heat-
exchanger and dielectric-fluids, 3) plasticizers for plastics and
coatings, 4) extenders for pesticides, and 5) ingredients for
caulking compounds, adhesives, paint, printing inks, and
carbonless duplicating paper. --= 'trt ^ \ o ^
TheCsoljyproducer of PCBs in the U. S., and probably the worlds
.
largest producer. Is the Monsanto Company. PCBs also are produced in
Great Britlan, France, Germany, the U. S. S. R., Spain, Italy,
Czechoslovakia, and Japan. Cumulative sales In the U. since the Introduction
of PCBs, are estimated at approximately 5 x 10 tons. Estimates for foreign
production are not available. Loss to the environment figures are
practically non-existent. Rough estimates based upon applications suggest
that approximately 20% of the cumulative PCB production is still in service.
It is assumed that the remainder has been discharged into the environment
by the various routes.
.
Monsanto Company has restricted the sale of Aroclor based upon
consideration of possible contamination of food products, or their ability
to control or monitor possible losses Into the environment. Sales were
to be restricted to confined systems entirely by 1972. No sales are made
to food processors. Similar controls, to our knowledge have not been
established by foreign manufacturers. Recommended procedure for thermal
decomposition of PCBs is by burning In oil suspension with flame
temperatures in excess of 1100C - the products are CO21 HgO, and Hcl. Monsanto
also has established special disDOSal facilities for its customers.
-X-
MONS 206178
DRAFT
DO MOT OUOTE OR CITE
Available evidence indicates that PCBs with a chlorine content of 42J
or less are degraded in the environment within a reasonably short period
of time -- possibly by microbial action. Higher Isomers degrade more
.
slowly. Recent data indicate that the half-life of PCBs with chlorine I
concentrations greater than SOX, for example Aroclor 1254, is much greater i
than DDT. Non-biological degradation in the environment is expected
to be slow.
.
Environmental transport models for PCBs have not been developed.
Conclusions regarding their behavior are based largely upon the results
of DDT research. With some modification models for DDT should be applicable to PCBs. The valadlty of DDT measurements prior to 19fi<l Is now beinq questioned due to the failure to correct for possible contamination by PCBs. The principal transfer routes for PCBs are: 1) aerial, 2) runoff, 3) sediments, 4) leaching from soil, op dumps, |5) uptake by organisms and plants, and 6) food transport. Little Is known about specific pollutant dynamics. Recent
data indicate that aerial transport Is the most efficient route, although river runoff and dumping will contribute^ot^more effectively
to local contamination. Measurable concentrations of PCBs have been found In rainwater. Recent measurements In the oceans by the Woods Hole Oceanographic Institution reveal that PCBs are widely distributed. No significant horlzonal gradients were observed, except In areas where dredge spoils were dumped or in the immediate vicinity of known sources of river runoff. This evidence indicates that aerial
transport Is dominant. Only very crude estimates of the annual losses of PCBs to the environment are available. These are: 1) 1.5 2.5 x 103 tons to the atmosphere, 2) 4-5 x 103 tons into fresh and
3 - HONS 206179
DRAFT
DO NOT QUOTE OR CITE
coastal waters, 3) 6.8 x TO4 tons into dumps and landfills, and
4) 10 tons into the soil as pesticide extenders.
Based upon our experience with DDT, and theoretical considerations. It has been postulated that PCBs would be found primarily on
particulates In the atmosphere. Recent data do not support this conclusion. Atmospheric concentrations measured in the vapor phase at Bermuda in February 1973 ranged from 0.2 to 0.5 ng/m^. No PCBs were found in
the particulate analyses during the Bermuda study. However, the sampling technique used does not differentiate conclusively between particulate
absorbed and vapor phase PCBs, PCBs have been found in particulate
samples taken In urban areas. Similar conclusions were drawn regarding PCBs In the aquatic environment; l.e., that they would be found
primarily In the sediment and absorbed on suspended matter. Recent measurements In the North Atlantic by the Woods Hole Oceanographic
Institution do not fully support this conclusion. Concentrations
reported In solution In the open Atlantic surface waters averaged 35 ppt (parts per trillion).
. There are essentially no data available on the concentration of PCBs In the soil. It Is expected that the amount would be small, except in the vicinity of dumps and land fills, If the estimates on the use
of pesticide extenders are correct. This may not be the case If aerial
transport proves to be dominant resulting in wide disposal of emissions frtCempUK.
from incineration. A Data on the concentration of PCBs in food are sparse. Measurable
quantities have been found in fish, milk, and eggs. None have been found In fruits and vegetables, however, the search has not been
extensive.
-H-
MONS 206180
no MOT QUOTE OR CITE
Based upon the few available measurements made In fresh water,
it is'estlmated that concentrations might range from 0.5 ppt in
unpolluted rivers and lakes to 500 ppt In highly polluted water. It
is postulated that little or no PCBs will be found in ground
water, since it Is expected that they would be absorbed on soil
particles. Concentrations ranging from 10 to 100 ppt were reported
in tap water In Japan.
.
,
The oceans and the soil are probably the primary sinks for PCBs in
the environment. PCBs were measured in soil in the Baltimore area. The
concentration ranged from 0 to 0.9 ppm. Reliable half-1ifes for these
mediums have not been determined. The persistence of PCBs in the t>DT ,,
environment should be comparable t^ppTp'Both DDT and PCBs are relatively q
non-polor and consequently will not be readily absorbed but also will
not be washed out by polar molecules such as water. Some evidence
suggests that the half-life of PCBs Is that for DDT.
Certain marine species are known to concentrate PCBs by factors of 10^ or greater over that found In the ambient waters. Uptake by
phytoplankton has been found to be very rapid. Concentrations of 1-3 ppm have been measured in phytoplankton samples taken from the North Atlantic.
The concentrations measured in zooplankton were less than In phytoplankton, and even less in fish. Maximum concentrations found In the ocean environment were measured in sea birds - approximately 100 ppm. The chromatogram peaks closely matched that cf Aroclor 1254, No evidence of lower Isomers (four or fewer chlorine atmos) were found.
Data were only recently obtained from the North Atlantic by the Woods tlolc Oceanographic Institution (See Prefeco). These studies are not yet complete, and the results have not been published. A paper on
"5-
HQNS 206181
the water analyses has been approved for publication in Science: G, R. Harvey, W. G. Stelnhauer, J. M. Teal, Polychlorobiphenyls in North Atlantic Ocean Water, Science in Press (April or Hay). The results
are very significant in that they fail to support important conclusions offered by other Investigators concerning ^the transport and behavior of PCBs in the environment, as well as previously established concepts regarding food chain magnification.
Information regarding threshold values is limited. PCBs are toxic
to some aquatic invertibrates at levels as low as 1 part per billion (ppb)
in ambient water. As mentioned previously, they are known to be moderately toxic to fish. PCBs apparently are non-toxic to terrestrial insects,
but act synergistlcally to increase the toxicity of several pesticides to Insects. Experimental studies have shown that PCB concentrations of approximately 100 ppm adversely effect reproduction In birds and fish. There Is strong suggestive evidence that adverse effects upon wild life populations, particularly birds and fish, may occur as a result
of present levels of PCBs In the environment, although such effects
are difficult to attribute solely to PCBs because the wild animals
are exposed to other pollutants. During the Yusho Incident In Japan, the minimum estimated toxic Intake was 200 pg/kg/day. This Is a much
higher level than that to which the general population Is exposed. FDA
has established a maximum permissible level of 5 ppm In edible portions
2,f o.l of fish, rppm In separate milk fat (0A ppm In whole milk), and
0.& 0.5 ppm in animal feed. The American Conference of Governmental
^ o.S'**
3 Industrial Hygienists has set a threshold limit value of 1 mg/nr for
*
occupational exposure to vapors of Aroclor 12'.2 and Aroclor 1254A
Only very crude estimates of the mean daily intake for the general population are available. This would be highly variable depending upon the diet. The major intake would probably be from
.
- fc"
MQNS 206182
' DRAFT
no NOT ni|OTE OR CITE
fish, milk, and eggs. Based upon available concentration data in
air, water, and food, the mean daily intake for adults would probably
be less than 100 ug/day.
.1
Work on uptake, retention, and excretion of PCBs is incomplete.
i
Very little work has been done on metabolism, and few metabolites
have been identified precisely. There is circumstantial evidence
that lower PCBs (tetrachloro and lower isomers) are metabolized very
rapidly in the environment. Evidence suggest that differential
metabolism is the primary mechanism In the environmental differentiation
of Isomers -- outweighing photolysis and mobility, Some higher PCBs
appear to be metabolized by birds and mammals. The major storage
tissue for PCBs is body fat - approximately 10-100 times the con
centrations in other tissues. Mean levels of 1 ppm in human
adlspose tissue have been reported in the U. S., and Germany;
respectively. However, in one study, 50t of the samples were
negative.
Evidence regarding teratogenic, carcinogenic, and mutagenic effects
of PCBs Is Incomplete. Little work has been done in these areas.
-7-
.V
HONS 206183
B. .CONCLUSIONS
DRAFT
nn r?!!OTr no ftTf
Commercial production of PCBs began in 1929; however, these chemical
compounds were not identified as environmental pollutants until 1966.
Considerable research has been devoted to the toxicological properties
of PCBs, but many important questions still remain unanswered. Critical research areas have been identified which will require several years
for solution. In the meantime, it is important that action be taken to
prevent further accumulation of toxic materials in the environment
which may adversely effect the biota. Logical conclusions may be drawn
from our present knowledge, which may serve as a basis for decisions
regarding preliminary control actions. A number of conclusions expressed
In the literature on PCBs are based upon extrapolation of our kneW1|age': and experience regarding DDT, while others are well supported with
reliable observations and experimental data. Recent data suggest that
certain extrapolations based upon DDT properties and behavior may not
be valid; therefore the risk of error must be accepted and weighed
accordingly. The following conclusions represent the views of the
members of the NERC/RTP Task Force on PCBs.
1) PCBs are toxic to humans and certain animal species; however the
degree of toxicity varies depending apparently upon the chlorine content
of the molecular structure.
2) PCBs are synthetic pollutants with no counterpart in the natural environment; therefore observed environmental concentrations represent
solely the contribution from anthropogenic sources. The rate of
release of PCBs into the environment has been significantly greater
HONS 206184
than the rate of degradation.
draft
DO NOT QUOTE OR CITE
3) PCBs now are widely distributed in the environment. Measurable
concentrations have been found in air, water, soil, and biota components.
; 4) Certain species of marine life may concentrate PCBs by a factor
3c
,
of 10 - 10 . Further concentration may occur within the vertibrate
food chain. Concentrations found in sea birds have been 107 - 108
times greater than those in ambient water.
5) The principal exposure route for humans is via food -- primarily
fish in the diet. Intake via air and water are small in comparison,
except in cases of contamination or occupational exposure.
6) Reliable threshold values for PCBs have not been determined.
The population involved in the Yusho incident in Japan had an Intake of
200 ug/kg/day or greater. PCBs are moderately toxic to some marine
invertibrates at concentrations as low as 1 ppb in ambient water.
Growth of phytoplankton is inhibited at levels of 10-100 ppb.
7) A reliable half-life for PCBs in the environment has not been
determined; however, there is some evidence that it may be greater than
for DOT.
8) Lower Isomers {tetrachloro and lower) appear to be degraded
rather rapidly in the environment. Some pentachloro and hexachloro
Isomers appear to be metabolized by birds and mammals, but the
metabolites have not been identified.
9) Work on teratogenicity, mutagenicity, and carcinogenicity is
Incomplete. Conflicting results have been obtained.
HONS 206185
*v
. DRAFT rr
nn wnT QUOTF. OR OITE
10) The long term health and environmental effects of PCBs have
not been clearly established. A decrease In certain bird and fish
7 )populations has been associated with PCBs. (
- \*S
A o rft
11) Present PCB concentrations in ambient air do not pose a direct
threat to human health and welfare; however, the total concentration
accumulated in the environment does pose a threat to some components of
the ecosystem.
12) Prudent action should be taken to control the further release of toxic PCBs into the environment. Priority should be given to the prohibition of the use of toxic PCBs in non-conflned systems whose primary disposal route probably would be through open-burning dumps or other inefficient or uncontrolled incineration processes.
10-
MONS 206186
DRAFT
HO NOT QUOTE OR CITE
II. REVIEW OF SAMPLING AND MEASURING TECHNIQUES
A. Introduction
1
1. Structures In a previous task force document on the PPOM the analysis of the
large polynuclear compounds (4 to 7 rings) were discussed. These
included the polynuclear aromatic hydrocarbons (or arenes), the aza
arenes, the imino arenes, and arenes with one or more ring carbonyl
groups. In this document we will discuss the analysis of the polychloro
derivatives of the di- and tricyclic hydrocarbons: biphenyl, I,
p-terphenyl, II, naphthalene, III, dibenzofuran, IV, and dibenzp-j>-dioxin,
V. {See Figure II-l). Two other terphenyls exist in addition to II; these
are the o- and m- isomers. Most of the discussion will concern the . polychloroblphenyls (PCB).
Most of these compounds are marketed under a number of commercial
trade names, e.g. Aroclor, Clophen and Phenoclor. The Aroclors from Monsanto
Company are classified by a four digit number and consist of mixtures
of polychlorinated biphenyls and terphenyls. The first two digits
represent the hydrocarbon type, e.g. 12 are chlorinated biphenyls, 25
and 44 are blends of chlorinated biphenyls and terphenyls (751 and 60%
biphenyl, respectively), and 54 are chlorinated terphenyls. The last
2 digits give the weight percent of chlorine, e.g. Aroclor 5460 Isa
chlorinated terphenyl containing 601 chlorine. Environmental PCB most
often-contains about 501 chlorine per molecule, that Is from 4 to 8
chlorine atoms per molecule.
-310 -
HONS 206187
DRAFT
DO ROT QUOTf OR r,ITE
I
Figure II-1. Structure of Polychloro Derivatives of D1- and Tricyclic Hydrocarbons. HONS 206188
DO NOT QUOTE OR CITE
An example of the polychloronaphthalenes available are the Halowaxes from Koppers Co. Inc., e.g. Halowax 1014 Is a mixture of tetra-, -penta- and hexachloronaphthalenes; Halowax 1051 is octachloronaphthalene; Halowax 1099 is a mixture of trichloro- and tetrachloronaphthalenes (1). The' percent chlorine values for the different Halowax numbers are 1031 - 221, 1000 - 261, 1001 - 501, 1099 - 521, 1013 - 561, 1014 - 621, and 1051 - 701. 2. Intercalibration and standardization
Since 1966 when the PCBs were found to be an environmental pollutant, (2) PCBs, along with DDE (1,l-dichloro-2,2-bis(p-chlorophenylJethane), have been reported to be the most abundant chlorinated aromatic pollutantsin the global ecosystem (3).
It is evident that appropriate recommended methods are necessary to make it possible and meaningful to compare the PCB values obtained in widely separated laboratories. Expensive interlaboratory comparisons and standardization of methodology are going on constantly and much of this frenetic activity leaves an analyst In search of accuracy with a gnawing feeling of disquietude and a touch of dissatisfaction. It takes a committee quite a while to "standardize" a method and by that time It can become obsolescent. Because of the rapid evolution of methodology and Instrumentation any method to be recomnended for the use by laboratories new to the field, or for Interlaboratory comparison, should be thoroughly evaluated in
the laboratory and in the field so that its shortcomings and
advantages are known. The most that such a method can be is a
recommended tentative method.
`
HONS 206189
L/IW I
DO NOT QUOTE OR CITE
Some interlaboratory comparisons have been made for the PCB (4,5). Aroclor 1254 at the 1.1 and 2.1 ppm levels showed a percent recovery range of 63 to 95 (average 78) and 66 to 77 (average 73),
respectively (4). 3. Contamination
.
Since the mixtures of PCBs, pCTs and PCNs (oolvchloronaDhthalenes) are used as standard test mixtures, their contamination with polychloro derivatives of other ring systems becomes of some Importance.
Polychlorodibenzofurans (PCDF) and PCN have been found in 2
comnerc-ial PCBJ^Clophen A60 and Phenoclor DP6 (6). These mixtures were chromatographed on a ^T^orisil column, the 25% diethyl ether in
hexane fraction evaporated to 1 ml, and this separated by GLC. From
the fragmentation patterns obtained with mass spectrometric analysis the impurities were identified as tetra- and pentachlorodibenzofurans and hexa- and heptachloronaphthalenes. The upper limits of pentachlorodibenzofurans were estimated to be 5 ppm and 20 ppm in
Clophen A60 and Phenoclor DP6, respectively. The gas chromatogram of the third fraction of Clophen A60 (Fig. 11-2) and the mass spectrum of the
pentachlorodlbenzofuran (Fig. II-3) are shown. Thus, with the help of mass spectrometry about one nanogram of contaminant can be detected in a 100 u9
sample. This means that the lower limit of detectability of contaminants without prior concentration Is 10 ppm (7).
The physical and chemical properties of the PCB and PCN are similar
(1, 8). Consequently,the PCN, in addition to some of the pesticides,
interfere-in the 'gas chromatographic analysis of PCB. Techniques should be
23 HONS 206190
DRAFT
DO NOT QUOTE Of! OITE
Figure II-2. Gas chromatogram of third fraction of Clophen A60 {showing pattern identical to that for third fraction of Phenoclor DP6). Data for peaks 1-5 are given in Table 2.
a4 HONS 206191
DRAFT
DO NOT QUOTE Of? CITE
.C-r
.fj/jtiro JT-.3 ,-^ss spectrum of pentachlorodibenzofuran (mass no. 338)
BdbtaiivJO"from third fractions of Clophen A60 and Phenoclor DP6 (Peak
4 in Fig. 1). The spectrum of heptachlorobiphenyl (mol wt 392) is
also present.
.
HONS 206192
LMWI DO NOT QUOTE OR CITE
developed which would eliminate this interference. Preliminary studies indicate that PCN accompany PCR on silicic acid chromatography, but their presence can be detected from an absorption maximum at 306 nm A * 329 <9>'
Another family of contaminants which have been found in commercial chloroaromatic compounds are the polychlorociibenzo-p-dioxins (PCDD) (10 - 13). In addition, 2,4,5-trichlorophenol and 2 ,4,5-trichlorophenoxyacetic acids have been found to be contaminated with PCDF .and PCDD (13). Commercial chlorophenols were analyzed for trace contaminants by solution in aqueous alkali, extraction with petroleum ether, fractionation on an alumina column, and followed by examination by electron capture gas chromatography and combined gas chromatography - mass spectrometry (12). The presence of PCDD, PCDF and polychlorodiphenyl ethers (PCDE) was confirmed. The 2,3,78tetrachlorodibenzo-p-dioxin was found in half the samples of 2,4,5trlchlorophenol. Hexa-, hepta-, and octachlorodibenzo-p-dioxins as well as a wide variety of PCDF and PCDE were present in most of the tetra and pentachlorophenols. In addition, the GC-MS data suggested that some of the chlorophenols contained methoxy and dimethoxy PCDF, and methoxy PCDE as well as hydroxy PCB. 4. Precursors
Some of the polychloro compounds are synthesized in the environment,or Inadvertently as a byproduct in the preparation of some industrial chemical. The contamination described in the previous section is probably due to the latter type of synthesis.
HONS 206193
UKAFT
DO NOT QUOTE OR CITE
Polychlorophenols have been stated to be precursors of the PCDD -(14). Some of the PCDD found In polychlorophenols and their sodium salt are shown in Table II-l. Some commercial grades of pentachlorophenol
i
have been found to contain as high as 2500 ppm PCDDSince chloracne, liver involvement, etc., result from
the handling 2,4,5-trichlorophenol, and this product is prepared by the alkaline hydrolysis of 1,2,4,5-tetrachlorobenzene, it has been concluded that byproducts which result during alkaline hydrolysis are the causative agents. These contaminants have been Isolated and have been shown to be tetrachlorodibenzofuran and tetrachlorodibenzo-p-dioxin postulated to be formed by the type of reaction shown in Figure 11-4.
Similarly the tetrachloro DD could be a contamininant in the herbicide 2,4,5-T(2,4,5-trichlorophe:toxyacetic acid), since this compound is produced by the interaction of sodium monochloroacetate with 2,4,5-trichlorophenol. 5. Artifact Formation
One of the difficulties in many types of trace analyses is the problem of the formation of test substances during the analytical procedure. Thus, in searching for nitrosamines in cigarette smoke it has been found that substantial amounts can be synthesized from precursors in the test mixture during collection of the sample. An example of this frustrating problem is the synthesis of an octachlorodibenzo-p-dioxin on a gas chromatographic column during the separation of some isomeric nonachlorohydroxydiphenyl ethers (15), e.g.
-57-
moms 206194
DRAFT
DO NOT QUOTE OR CITE
Table 11-1.
Polychlorodibenzotpldioxins in Polychlorophenols by Electron Capture Gas Chromatography (12)
' Sample
No. 5
6
7 8 9 10
11
12
t/ |
X3
OH
Position of Chlorine Atoms
Phenol 2.4.52,4,5-
2,4,52.4,52,4,52,4,6-
2,3,4,6-
2,3,4,6-
PCDD 2.72,3 ,7,81,3,6,82,3,7,8Pentachloro None 2,3,7,82,3,71,3,6,8HexachloroHexachloroHeptachloroOctachloroHexachloro-
Found ppm 0.72 1.4 0.3 6.2 1.5 0.07
93 49 15 14
5.1 0.17 4.1
Zl-
HONS 206195
Sample NO. 13; 14
15
16
17 18 19
20
Table II-1 (Continued). DQ MOr draft
Position of Chlorine Atoms
Mote or
Phenol
Found PCDD ppm '
2.3,4,6-
None
-
Pentachloro (PC)
Hexachloro-
14
Heptachloro-
5.4
Heptachloro-
9.1
Octachloro-
3.8
PC
Hexachloro-
20
Heptachloro-
1.3
Heptachloro-
10
Octachloro-
3.3
PC
Hexachloro-
0.96
Hexachloro-
38
Heptachloro-
10
Heptachloro-
39
Octachloro-
15
PC
Hexachloro-
35
Heotachloro-
23
PC
Hexachloro-
0.03
Hexachloro-
0.14
PC
Hexachloro-
13
Hexachloro-
12
Heptachloro-
35
pr
Hexachloro-
0.91
Heptachloro-
0.50
Heptachloro-
1.6
Octachloro-
5.3
-ai-
HONS 206196
Sample No.
21
nnTabic 11 -1 (Continued).
draft
Position of Chlorine Atoms
n NOT QUOTE Of CITE
Phenol
PCDD
found .EHL
PC
Hexachloro-
IS
Heptachloro-
23
Octachloro-
15
HONS 206197
1)0 Rollon1
' Cl
l4\ ^ r>e55yf-e Offers
y--<
-<g>
? Cl
O /t4 a--
a
^of
\ox X/n
l (C|W& i
- ftJa,tl
cl -^Htl
Figure II-4.
Cl
HONS 206198
CJ Cl
DRAFT
DO NOT OUOTF OR 0|TE
Cl ci
ci
ct
6. Stability Although the polychloro polynuclear compounds are believed to
be very stable In the environment, there are Indications that they could be broken down or modified In an appropriate environment. The extremely high physiological activity of 2,3,7,8-tetrachlorodibenzo-pdioxin would seem to denote a high order of chemical activity in , living tissue.
Under mild conditions light can promote reactions In so-called unreactive halides. Both PCDD and PCDF are very unstable to light In the presence of organic substrates (16, 17) B. General Methods
In the determination of the polychloro polynuclear compounds the following criteria are desirable - pure standards, a good calibration procedure, high collection efficiency (from air, water, etc.), complete extraction from the collected environmental mixture, no loss during cleanup, no degradation during the chromatographic steps, no artifact formation during the procedure, good overall recovery, reasonable sensitivity, no Interferences, unequivocal characterization, as much simplification as possible, satisfactory intercalibration, capability of uninterrupted use in the automated or manual modes, and a high order of precision. Kith all this, all one can further ar-k for is accuracy.
HONS 206l
DRAFT
DO NOT OUflTE OR CITE
1. Standards For reasonably accurate work, pure standards or mixtures with a
known amount of test substance(s) are necessary. A few commercial sources are Aldrich Chemical Co., Analabs, Burdick and Jackson Lab., Chemical Procurement Labs., Eastman, K and K Lab., Monsanto Co,, Pfalz and Bauer Chemicals, and Sapon Lab. For example, Analabs is a source of the following 99% pure standards - " 50 PCB, 3 PCT, an octachloronaphthalene, 2 PCDD and an octachlorodibenzofuran.
Standards for PCBs (Aroclors 1221, 1232, 1242, 124B, 1254, 1260 and 1262) and PCNs (Halowaxs 1000, 1001, 1013, 1014, 1051, and 1055) are available from the Technical Services Division, Pesticides and Primate Laboratory, EPA, Perrlne, Florida. Standards for Aroclors 1242, 1248, 1254, and 1260 are available from Pesticides Reference Standards Section, Office of Pesticides Program, EPA, Washington, D. C.
In addition, synthesis procedures for PCBs have been reported (18, 19). All the PCBs were homogeneous on silica gel thin layer chromato-gra gram plates developed with heptane and gave one peak when chromatographed on a 4% SE-30 column (18). The mass spectra of the compounds confirmed the molecular composition.
The Arod or mixtures can be used as standards for measuring environmental mixtures containing PCB. A thorough analysis of the mixture must be performed beforehand. Aroclor 1254 has been used as such a standard, but the levels of PCB obtained have been much too high (20). Because of impurities In an Aroclor being used as a standard, quantitation based on that one Aroclor will be erroneous.
HONS 206200
33
DRAM
DO NOT QUOTE OR CITE
However, semiquantitative measurements of PCB residues have been made using one peak of a commercial mixture as a standard (21). Quantitation has also been based on an average of 2 or more peaks.
The compositions of Aroclors 1242, 1254 and 1260 have been determined by elemental analysis, GC with a Coulson conductivity detector, and combined GC-MS (22). A procedure using these Aroclors Is recommendc-d for analyzing environmental samples containing more than one Aroclor mixture.
In another GC procedure 6 Aroclor standards have been used so as to
minimize the errors due to impurities (20). Chromatograms of six PCB
standards were obtained for Aroclor 1232, 1242, 1248, 1254, 1260, and
1262. They were dissolved In hexane to concentrations of 2 ng/^1. A
4 pi Injection placed peak heights on the linear portion of the
standard curve for each Aroclor. Duplicate 4 jjI Injections were
made. Total peak area for each Aroclor was determined by the cut and
weigh method. Stock solutions of the Aro'clors in Isooctane are stable
except when exposed to sunlight.
Another mixture which has been assayed by GC-MS to some extent is
the French product, Phenochlor DP6 (19). Four of its major components
are 2, 2', 4, 4', 5, 5* - hexachloroblphenyl, the 2, 2', 3, 4, 4', 5* -
Isomer, and 2, 2, 3, 4, 4', 5, 5' - heptachlorobiphenyl and Its 2, 2', 3,
3', 4, 4*, 5 - Isomer. This mixture could also be Investigated as a
standard.
Of course, more accurate quantitation will be achieved when pure
Individual PCB components become available.
A polybromoblphenyl mixture for standard use Is Firemaster BP6
(hexabromobiphenyl) which gives 7 peaks with retention times of 0,50,
0.88, 1.00 (m.ijor peak), 1.41, 1.77, 1.S4 and
relative
to decachlorobiphenyl on the 0V-210 column (23).
- 3W -
HONS 206201
The highly toxic 2,3,7 ,8-tetrachlorodihcnzo-p-dioxin has been prepared from 2,4,5-trlchlorophenol in pure form (10). Thirteen
S. -t-
chlorinated dibenzo-p-dioxins containing from 1 to 8 chlorine atoms have-*
? ^3.
been prepared for use as standards in the development of analytical
methodology for the PCDD (24). Internal standards are also of value in checking recovery. There
is a definite need for these standards since It is difficult to measure
.A -<
accurately the small volumes remaining after evaporations and the less
than 10 ul volume Injected into the gas chromatograph. This standard
must have a retention time different from those of the PCBs and must be
in a clear area of the chromatogram. Where much dilution takes place and
the internal standard could be diluted to the point of invisibility, di
lutions can be accomplished by means of a standard solution of the
internal standard. In this way the pe*k of the Internal standard
is referred to the corresponding peak in the standard solution.
DPDE (1,1-diphenyldichloroethene) has been used as an Internal standard
In residue analysis. A standard injection of a standard such as p, p`-
DDE can indicate whether detector sensitivity has changed from when the
response curve was calculated (20) and so a simple factor can be applied
to the entire curve and all isomers quantitated as before.
2. Contamination
During the analysis for PCB and other polychloro polynuclear
compounds, great care must be taken to avoid contamination of samples,
since PCB may be present in a variety of products. PCBs of the
40X chlorine variety has been found in cardboard and in a wrapping
plastic material. Glassware should be washed with chromic acid and
liquid-chromatographic columns should be eluted with petroleum ether
prior to use. The presence of aromatic hydrocarbons in pesticide-grade
hexanes can affect the elution patterns of PCH and other chlorinated
compounds from silicic acid columns (9). Several batches of silicic
- 35-
MONS 206202
DO NOT QUOTE OT CITE
acid Slllcar ^ (Mallinckrodt) were contaminated with 0.031 to 0.163
pg g of PCB expressed as Aroclor 1254, Hexane of satisfactory purity 'Is dit fficult to obtain. It is reported to contain a significant amount of an impurity that has the same retention time as that of 2,3,7,8-tetrachlorodibenzo-p-dioxin. Efforts to remove with fuming sulfuric acid, potassium permanganate or alkaline silver nitrate were fruitless. The only solution Is the use of distilled batches of carefully selected hexane. The many usages of the PCB shows the wide extent of contamination possible (25). 3. Sampling
In sampling for PCB In air, water, soil and tissues different factors are Involved. The collection efficiency and the physical state of the test substances are of importance In air analysis. The way the material Is collected will depend on whether It Is In the vapor and/or the particulate phase, the volume of air flowing through the samples per unit time, the temperature of the air, and the composition of the atmosphere in terms of its pollutants.
The solubilities of the PCB in water and their attraction to the particulate phase will determine whether water, aqueous particulate, mud, etc. are collected.
Sampling of air, water, soil and tissues will be discussed more fully In the appropriate sections. 4. Interfacing - sampling to Separation
A cleanup procedure Is necessary to concentrate the polychloro *
compounds and to eliminate all the Interferences, If possible. One of the big problems has been that the PCB are extracted together with other hydrocarbons and their halo derivatives. Since many of the cliloro compounds have retention times Identical to the PCB on non-polar columns,
HONS 206203
DRAFT
00 NOT flllOTI: OR CITE
their analysis presents a problem which is not completely soluble
by gas chromatographic moans alone. Accusations have boon made
that much of the data obtained in the past for the pesticides are
unreliable because of this problem .and because of the lack of
proper confirmatory techniques.
`
The use of the electron-capture detector in the analysis of
the polychloro compounds has the advantage of high sensitivity and
the requirement for small amounts of material for analysis. Cut, a vigorous
cleanup procedure is necessary to prevent gross contamination of the
detector by other chlorinated compounds present .and to remove
interfering substances with the same retention times as the PCBs. No
single cleanup procedure is adequate. Most of the cleanup methods
used for this separation employ adsorption column chromatography and
constitute a difficult and time-consuming step. Some of the problems
associated with adsorption column cleanup methods are contamination
of the adsorbent^involved procedures for adsorbent preparation, the
large quantity of clean glassware required land the errors that may
be Introduced by way of adsorptive loss of residues on glass,
plastic surfaces* on the column,ind from interfering substances
present on the adsorbent or in the eluting solvent.
Separation prior to gas chromatography has been used by many
researchers. Simpler chromatograms are obtained. Thin layer
chromatography, reverse paper chromatography and column chromatography
afford means of obtaining partial separations of chlorinated compounds
from PCB and fractions can easily be obtained where only Aldrin,
Heptachlor and p p* DDE remain with the PCB. The'former two show
- 37
HONS 206204
' DRAFT
DO NOT QUOTE OR CITE
little Interference with PCB bands, but p p' - DDE can emerge with the major PCB peaks using non-polar comoounds. TLC has given this sort of separation using silica gel and alumina (26) as has column chromatography with alumina or silica gel (27), or Florisil (28). It is possible to carry out a separation leaving only Aldrin with the PCB (29). Column chromatography with silicic acid - celite and elution with petroleum ether is used. This type of separation is possible as long as the column is not overloaded and there is no . tracfe of polar solvent In the sample. Double column systems have "also been used, e.g. alumina'partly deactivated with 5% water followed by silica gel.
Solvent partition methods also can be used prior to separation, e.g. acetonitrile or dlmethylsulfoxide/hexane. The polychloro compounds can be extracted into hexane and then Into dimethyl sulfoxide or dimethylformamide, water is then added and they are re-extracted into hexane.
Another possible method Is through chemical change of the test substances or of the Interferences, and In so doing changing either their physical properties or retention time so they present no interference to the PCB. Thus, pesticides can be nitrated (30) in hopes that the PCB are unaltered while the DDT is essentially removed. Unfortunately.5J?ie DDT derivative peaks..emerge on the chromatogram and some of the lower chlorinated PCB are affected.
Alternatively, saponification with alcoholic potash leads to the dehydrochlorination of p p1 DDT, p p1 TDE, and Toxaphene with the derivative peaks appearing earlier in the chromotogram and the
-33-
MONS 206205
DRAFT
DO NOT QUOTE Off CITE
PCB reportedly unaffected, BIIC is destroyed by this procedure. PCB can also be differentiated from DDT using carbon-skeleton chromatography.
f Sulfuric acid can also be used as a cleanup agent (31). One modification involves shaking up the hexane extract with SO^ (32). This treatment destroys dieldrin and organophosphate pesticides. 5, Separation The standard method for analyzing the PCB fraction of an extract Is by gas chromatography. We will first discuss the separation of the PCB from other interfering molecules. Because of their similar polarities and chemical properties the PCBs in a sample are carried through the usual pesticide extraction and screening procedures,and are frequently mistaken for DDT and analogs in routine monitoring.
PCBs accompany chlorinated hydrocarbons in the usual extraction and cleanup techniques,and both groups must be separated before quantitation by gas chromatography. Column and thin layer chromatography are usually used for the separation. PCBs are eluted from Florisil columns with hexane, DDT and other pesticides with mixtures of ether and hexane (28). Other workers have shown that successful implementation of this method requires a preliminary examination of the elution behavior of the pesticides from Florisil (33). Column chromatography on silicic acid separates PCB from all common chlorinated hydrocarbon pesticides except p, p' - DDE (27).and under very carefully controlled conditions even from p, p' - DDE (29). DDE and PCB can be eluted on activated Florisil columns With n-hexane with dieldrin and endrin eluting with 103! diethyl ether in
-39-
MONS 206206
. uiw i
DO NOT QUOTE OR CITE
hexane (21). PCB can also be separated from the chlorinated pesticides
by column chromatography on charcoal. The latter are eluted with 25%
acetone In ethyl ether and PCB are subsequently recovered by elution
with benzene. Column chromatography on alumina is used to separate
I
PCB from PCDD (34).
|
The difficulty in most of these separations is the separation of
PCB from p, p' - DDE. One way of canceling this problem is to
oxidize p, p' - DDE to 4, 4' - dichlorobenzophenone without affecting
the PCB (35, 36), Chromium trioxide was used as the oxidizing agent.
TLC on alumina with heptane as developing solvent has been used
to separate PCB from the pesticides. The spots were extracted with
methanol - hexane and analyzed by gas chromatography (37). Other TLC
methods of this type include separations on silver - nitrate - coated
alumina with 5% benzene in hexan^ or hexane after Ct-03 oxidation of
p, p* - DDE (35, 36), a two - dimensional technique (38), and reversed
phase TLC (39).
Chromium trioxide has also been used to oxidize PCN in the presence of PCB and thus cancel this interference (40). Where both of these families exist together, or PCNs are found in the presence of the chlorinated hydrocarbon pesticides, this interference in GC analysis definitely exists (41). A silicic acid column chromatographic method has been used to separate PCN from the pesticides and permits GLC determination without interference (42).
Some PCDD have also been separated from the PCB with the help of alumina column chromatography (34) and alumina column chromatography (43), After isolation electron capture gas chromatography is used for analysis.
-Mb
MONS 206207
draft
. DO NOT QUOTE OR CITE
.`For the separation of individual members of the PCB or other
polychloro compounds gas chromatography has been the method of
choice. Column temperatures have usually ranged around 180 to 200.
A wide variety of chromatography packing has been used, e.g. DC-200 on Chromport 30, DC-200 on Chromosorb W, 105! DC-200 on Gas-Chrom Q,
SF-95, QF-1, 15! SE30 on Chrom Q, OV-1 silicone oil, Silicone Epikote
on Diatomite CQ, 65! QF-1 .and 45! SE-30 on Chromosorb W.
One of
the most frequently encountered is the silicone grease SE-30, often
mixed with other material such as QF-1. An example of some of the
separations obtained and the detector response is given in Table II-2
(44). The separation was accomplished on a glass column (6 ft x 4 imi)
containing 4t SE-30 on acid washed Chromosorb W (100 - 120 mesh)
operated at 200.
Thin layer chromatography can also be used to separate the PCB (39)
Kieselguhr G saturated with 8 vol. 5! liquid paraffin in petroleum ether
Is developed with acetonitrile - acetone - methanol - water (40: 18: 40:
2) saturated with liquid paraffin. The type of separation is shown in
Table 11-3- The reversed phase partition TLC system can be useful for
the separation of the components of a PCB mixture and can be used in
combination with GC for the study of the composition of PCB residues.
Visualization of the TLC spots was accomplished by UV irradiation of
the silver nitrate sprayed plate.
PCT are not eluted from GLC columns used for PCB. They can be
determined by GLC on a 6 ft x 4 imi glass column, containing 3% OV-210
on Chromosorb WAW 60/80 and operated at 200 (45) or on a glass
column (6* x 1/4") packed with 3% Dexsil 300 on 100 - 120 mesh Gas -
Ml MQNS 206208
. . draft
Table n-2 D9 MOT QUOTE OR CITE
Retention time and electron-capture detector
response of chlorobipnonyls
'
Compound
Rclative retention tine
(P.P'1-DDE-1.00)
Relative respome-
per ng + standard devTation
(p ,p`-ODE-1.0
4-chlorobiphenyl
0.17
2- -
0.11
3-
0.14
4,4'-dichiorobiphenyl
0.30
3,3'2,2'-
" *
.
0.25 0.15
3,4-
0,28
2,4-
-
. 0.19
2,6-
"
0.16
2,4,4*-trichioroblphenyl 0.39
2,4,6-
0.24
2,2` ,4,4'-tetrachlorobiphenyl
0.51
3,3'.4,4*- 2,2',6,6*- -
0,96 0.33
3,3', 5,5'-
0.70
2.3,4.5- "
0.69
2,3,5,6-
-
0.51
2,3 ,4,5,6-pentachlorobiphenyl
1 .00
2,2',4,4*,6,6'-hexachlorO' biphenyl 0.78-
3,3' ,4,4' ,5,5'- "
2.98
2.2',3,3\4,4*,6.6'-octachlorobiphenyl 2.62
2,2' ,3,3' ,5,5' ,6,6'-octachloroblphenyl 2.45
Decachlorobiphenyl
8.20
Aroclor 1254
Aroclor 1260
0.0033+0.00005 0.0030+0.00004 . 0.0006+0.00001 0.0152^0.0002 0.0155+0.0001 0.0131+0.0001 0.0388+0.0002 0.0450+0.0004 0.0815+0.0049 0.298+0.010 0.276+0.006 0.206+0.003
0.770+0.027 0.0403+0.0016 . 0.625+0.045 0.715+0.010 0.505+0.010 1.30+0.017
0.545+0.029 1.1510.064
1.5S+0.020
1.53+0.076 1.61+0.086 0.910+0.008 1.35+0.010
4* HONS 206209
DRAFT
Table 11-3 DO NOT QUOTE OR CITE
Relationship between Spots Obtained hy TLC and Peaks Obtained by GC of Phenochlor DP6
Spot No. 1 2 3 4 5 6 7
Corresponding Peak No. 13
' 11 6. 9, 12 7, 8, 10 2, 4, 5 3. 6 1. 3
MONS 206210
Chrom Q operated at 310 (46).
DRAFT
n0 NOT QUOTE OR CITE
,
PCDDs can be separated on a column of 2% OV-17
-"
. if.
on Diatomlte CQ or It Hi-Eff 8 BP on Gas Chrom 2 (10), or on a
stainless steel column coated with Dexsil 300 and programmed from
150 to 215 with helium as carrier gas and flame ionization
detection (11).
Examples of separations are shown for Aroclor 1260 (Figure II-5),
Arodor 1254 (Figure II-6), and for PCDD, PCDE and PCDF (Figure II-7) (12).
6. Analysis
Some of the methods worth improving.which are believed to be
gaining wide acceptance (47),include procedures developed by FDA (48),
Official Methods of Analysis, 1970 (49), Armour and Burke (29) and
Porter et al (50).
The many unidentified compounds in PCB preparations complicate
the quantitation of PCBs. Assay has been by total peak area (29) or
area under one (21), two (51) or more (52, 53) peaks, or peak heights
(53 - 56). A method based on the average electron-capture detector
response to PC8 containing one to seven chlorine atoms also has been
described (20). But since position of substitution affects the
response, it is no more accurate than the others.
The dissatisfaction with the accuracy obtained is evident from
the many methods of quantitation being used. Some people estimate
that the quantitation of PCB is accurate only within a factor of 2 (57), whereas others assert It is impossible at the moment to quantitate PCB with any degree'of confidence (58).
M4 MONS 206211
DRAFT
DO NOT QUOTE OR CITE
4*0 Mft
Figure H-5. Separation of Aroclor 1254 by capillary column-qas chromatography Conditions: 50 ft. x 0.02 in. SCOT Apiezon-L column; 205 , He flow 2.5 ml/min; flame-ionisation detector. Structures of Isomers responsible for major peaks are indicated (60).
MONS 206212
Figure II-6, '
EC chromatogram of hroclor 12G0 chromatographed
on SE-30 with a Ni~G3 detector operated in the DC mode. The peak identification numbers
correspond to the retention time relative to
p,p*-DDE=100(22).
.
HONS 206213
I
DRAFT
DO NOT QUOTE OR CITE
Figure II-7. A, Gas chromatogram of a mixture of chlorodibenzo-p-dioxins (Cln-D): (1) 2-C1-P; (2) 2.7-CL2-D; (3) 2,3,7-Cl3-D; (4) 1,3,6,8-C14-D; (5) Cla-D isomer; (6) 2,3,7,8-CU-D; (7) CI5-D isomer; (8), (9), (10), and (11) C15-D isomers; (12) and (13) CI7-D isomers; (14) Clg-D; a * aldrin standard. B, Gas chromatogram of a mixture of di-, tri, and tetrachlorodlbenzofurans (Cln-F) (C12-F, CI3-F, and CI4-F) and octa-, nona-, and decachlorodiphenyl ethers (C1n-E) (Cls-E, C10-E, and
Cl-|q-E) a e aldrin standard. EC-GIC conditions: 7 1 x 4 ntn id glass coiled column packed with 3% XE-60 on 80-100 mesh Gas-Chrom Q; column temperature, 215C; detector voltage, 80 v (tritium source); 1 x 10`9 AFS; nitrogen flow rate, 55 ml/min, Three vl containing 4-140 ng of each component was injected (12).
HH HONS 206214
DRAFT
DO NOT QUOTE OR CITE
--Quantitation of PCB from electron capture chromatograms is
complicated because the EC detector responds differently to each
PCB isomer (44, 59). The wide response is demonstrated in Table 11-2. Quantitation by direct comparison of an unknown EC chromatogram with those of Aroclor standards is difficult because individual peaks in environmental samples are sometimes obscured by pesticide residues
are completely missing, or have- considerably different relative
intensities.
_
.
The weight of PCB present in each GC peak of a given Aroclor
*
can be calculated from two pieces of information: (1) the empirical
formula of the compound represented by the peak, and (2) the absolute amount of chlorine represented by the peak. Combined GC - MS determines the first, and a GC equipped with an electrolytic
conductivity detector can determine the second. The results are
shown for Aroclor 1260 in Table II--4 and Figure II-5- The gas chromatograms of Aroclor 1254 and of a mixture of PCDD and PCDF are shown in Fig. II-6 (6D) and Fig. II-7 respectively (12),
PCT can be determined by GC on a 6 ft. x 4 mm glass column
containing 3X 0V-210 on Chromosorb WAW 60/80 and operated at 200 (7).
Eight major peaks are obtained.
It Is also possible that the PCB can be analyzed by pulsed source time resolved phosporimetry, as has been done with the monohalobi phenyls.
Table 11-5(61). The limits of detection for the three 4-halobi phenyls are
about 1 ng,for 2- and 4-chlorobiphenyls about 10 na,and for 3-chlorobiphenyl about 10 /jcj- It also seems probable that time resolved phosphorimetry could be of value as a confirmation technique.
MS HONS 206215
DRAFT
00 NOT QUOTE OR CITE
RRTa
70 - 84
T 98 1.104
117 125
14C 160
174 .2.03
f232 L244
280 332 372 448 528
.
Table II-4
Composition of Arorlor 1260 (22).
Mean Weight Percent
Relative . Std.. Dev. .
2.7 ` 6.3 4.7 1.6 3.8 3.5
3.3 12.3
14.1 4.9
12.4 9.3
9.8
11.0 4.2 4.0 .6 1.5
6.7 3.3
3.6 2.2
' /
2.7 A n '
3.4
2.4 5.0 8.6
25.3 10.2
Number of Chlorines0
*
5
5*" d
65 60% 40% 6 5' 1 15% 6. 1 85% 6
J6") 50%
7 50%
6 i i n
7. 90* e
6 10% 7j 90% 7 7 8 8 8
Total
98.6
^Retention time relative to p,p'-DDE=100. Measured fron .first appearance of solvent. Overlapping peaks t'.at are quantitated as one peak are bracketed.
^Standard deviation of six results as a mean of the
results. cFrom GC-MS data. Peaks containing mixtures of isomers
of different chlorine numbers are bracketed.
^Composition determined at the center of peak 104. Composition determined at the center of peak 2 32.
49 MONS 206216
DRAFT r(Tf
DO NOT QUOTE OK KITE
Table II-5.
> Phosphorescence Characteristics of Selected
Halogenated Biphenyls (61)
Halogenated Biphenyl 2-Chiorobiphenyl 3-Chlorobiphenyl 4-Chlorobiphenyl 2-Bromobiphenyl 3-Bromobiphenyl 4-Bromobiphenyl 4,4'-Dibromobiphenyl 2-Iodobi phenyl4-Iodoblphenyl
* Peak Phosphorescence
Emission Wavelength,3
nm
465
480
477
475
480
480
485
490
480
aSolvent: ethyl alcohol. Relative errors in lifetimes are less than 10%.
PhosphoresC' Lifetime, msec
170. 1300. 570.
3.3 58. 17. 12.
3.0 3.2
$C> MONS 206217
DRAFT
DO NOT QUOTE OR cue
To avoid difficulties in quantitation^the PCB in a sample can be converted to decachlorobiphenyl and the EC signal from this derivative can be compared with that from conversion of a known amount of Aroclor 1254 to decachlorobiphenyl. This type of method is desirable for a monitoring program designed for rapid, inexpensive, and sensitive measurement of the total quantity of PCB without regard to composition. However, the development and usage of such a method would not preclude the need for the assay for individual PCBS',
Extracted PCB residues can be exhaustively chlorinated with chromous chloride or antimony pentachloride to decachlorobiphenyl and the electron capture signal of this compound can be compared to the EC signal of a known amount of a reference PCB mixture treated similarly (62), Aroclor 1254 has been chlorinated with antimony pentachloride and the resulting decachlorobiphenyl has been determined by GC (63).
Screening methods forPCDD residues based on their chlorination to octachlorodibenzo-p-dioxln, VI, have
ci c\
VI been.developed (64, 65), The PCDD can be detected in the presence of PCB, PCN and PCDF. Chlorination with chlorine took place In the
-SI
MONS 206218
DRAFT
DO NOT QUOTE OR CITE
presence of iron filings and iodine. Ferric chloride - iodine (66) and antimony pentachloride (67) have been used as catalysts but were reported to give unsatisfactory results on the microgram scale (64). The recommended method consists of chlorination, liquid chromatography on alumina followed by electron capture GLC.
Another method of possibly quantitating the PCB as one entity involves carbon skeleton chromatography (68). The PCB residue is converted essentially into a mixture of cyclohexyberizene and biphenyl at a catalyst temperature of 300, and into cyclohexyl benzene, and bicyclohexyl at 260. The method needs further investigation and optimization. The technique may also be useful for confirmation purposes.
The formation of decachlorobiphenyl and its change into a measurable derivative by nucleophilic substitution reactions at the 4,4' - positions is another reaction that could be of value in developing an inexpensive monitoring method.
Confirmatory techniques are vital to assay methods for the environmental organic pollutants. The big problem Is to identify component X in an environmental test sample. For the polychloro compounds assay is not enough; one must also be able to identify the pollutant unequivocally. In the majority of investigations one or more- of four types of parameters have been used to identify trace amounts of organochlorine compounds: (1) GLC retention times using two or more stationary phases, (2) TLC R^ values using one or two systems, (3) preparation of derivatives and matching of the GLC retention times (and/or TLC R values) of the products with those of
-531-
HONS 206219
,.
DRAFT
DO NOT QUOTE OR CITE
the known compounds, and (4) partition p-values. None of these
procedures or their combinations are completely satisfactory to
establish the identity of a component in an environmental sample.
Since chemical identity at the submicro level is difficult, we will
i
address ourselves to this problem.
j
The use of a double GC column system minimizes the risk of
false identification, but GC alone cannot give an unequivocal
identification. The use of GC with chemical treatment increases the
certainty of the identification.
The uncertainties of identification are also confounded by the
possibility that other halogens may be present in the PCB. Some of
these compounds have been mentioned previously. Examples are
trifluoropentachlorobiohenyls and trifluorotrichiorobiphenyls used
In hydraulic fluids, and diaminopolyhalobiphenyls and dihydroxypolyhalo-
blphenyls used in the preparation of flame resistant polymers and
reinforced plastics.
GLC has been the prime tool used in the analysis of organochlorine
compounds, but it cannot give unequivocal characterization either with
the help of retention Indices, by the matching of retention time and
peak height distribution with those of commercial products, by the
use of halogen-specific microcoulometry to determine the presence of
halogens In the compounds causing individual peaks, or by determining
the resistance to attack by hot alcoholic KOH.
GLC-IR has also been used in identification studies (69).
Identity was assumed if the synthetic PCB, when added to the Aroclor
and chromatographed, enriched the appropriate peak and the IR spectrum
S3 HONS 206220
DRAFT
DO NOT QUOTF OR CITE
of.the synthetic Isomer matched that of the isolated ArocTor isomer. Summary of the results are given in Tables II-6 and II-7,
With the help of carbon-skeleton chromatography PCB and biphenyl yield identical chromatograms that are different from those of DDT or other polychloro compounds (68).
Confirmation of identity can be achieved by combined GC-MS (70-72) which, In addition, yields the number of chlorine atoms per molecule (71). However, rearrangement of chlorine atoms on phenyl groups occurring in the electron-impact-induced fragmentation (7) limits the use of MS for structural studies. GC-MS does offer an excellent means of distinguishing PCN from pesticides and PCB (41). Identification of PCN has been made with the GC-MS system.
Mass spectrometric analysis has been used,even In the early work,to confirm the presence of PCB suggested by GLC data (21, 72). Although commercial PCB mixtures are complex, the mass spectra are relatively simple, since all Isomers of a particular molecular compositi give Identical molecular ions (60), Figure 11-8- The mass spectrum also reveals the typical Isotope distribution pattern which is highly characteristic of the number of chlorine atoms present in the PCB Isomers. The presence of these patterns facilitates identification of small quantities of PCB which may be present in a contaminated environmental mixture. The mass spectra of each set of isomeric compjunds are similar and the fragmentation pattern of all the compounds from the dichlorobiphenyl isomers to decachlorobiphenyl feature successive expulsion of chlorine atoms and molecules, Fig. II-9,
-54-
MONS 206221
draft T>0 NOT QUOTE OR CITE
Table II-G. Suuaary of Aroclor GLC rtntr.m tinier and identities.
Ra tonUmi Tim**
*jmn*lie CKiero biphenyl
Aroclor 11 1212 1242 lt 12S4
It Mphonyt UI ll.t 1 17 4 17.7
U.l W
n. a.i 21.0 t.r 1.4to i.*.i*
it i.ir ii.i 1.4. i* M.( 4,4' M M-i* at 1.4. r it.t 1.4.4' It.7 I.1.4'
a.i . a. 4,1' 41
M
44.1 41 i.i.w
4*.I i.4.r.!' 10.1 1.4,7*.4' 01.4 17
ft M.0.2.1'
X*P
XC X O* Xc
X X
X
Xc X XX
XX Xc X Xc X
X
X XX Xc X
X X X
X
kX XX
X Xc X X X XX Xc X XD X Xc X X6 X
c* X e* X Xc X Xc X Xc X XX Xc X XX XX
X Xc X Xc X X0 X XX XX XX XX
Xc Xc
Xc XD
(CooIiaumO
Table 11-6 (Continued)
Re. tern
tion Time*
Synthetic *4 fciplitn]rr/jj 1221
Aroclor 1212 1242 1241
1254
40 44
4t n.i 70
70.! 71 71 70 12 u M IS 17
K ft
101 104 107
1 117
111
in
120
11) 147
144 140 1H IK 171
I.l.f.4' i.i.o.r.i' 2.4.1'.4i I.M.2',4'
I.1.C.1M' 2.4.|,!>.r 2.4.5.2'.4'
pet
I.4.1.2M'
2.14. >'.4*
1.4.5.2".1*.O' 2.4.0,1\4`
I.4.J.2',4'.J>
XX XX XX
XX
X c* X xc
X c* X
XX Xc
X X Xc X X Xc X xc
X X Xc XX
XX XX
X XX
X Xc X Xc
X X Xc
X
X X
X
* RoUliv* topji'-OOEX 10*C on 100' x 0 02*5CDT5E-
JD column.
. * X Indicate* * QIC peak in thi* Aroclor at this reten
tion time.
* C meant that the synthetic compound in the second
Column
confirmed by ClC sno ffl in thif Aroclor.
Because of the fiber involved, most compounds **re
only confirmed In on# Aroclor. For inmpli. biphenyl is
probably proient in UJZ-1Z4I n wen s 1221,
'Only GLC data available.
* SomeiMftf alee alto preienL
-ss-
MONS 206222
DRAFT
' 00 NOT QUOTE OR HITE
Table 11*7. RGB Isomers Found To Ba Absent from Aroclors 1221-1254,
Chlo(6frpnci)yt
ftctenl/ori
7.1.41.4,4' l.S.V 1.1,1' *..*
I,*.*'.*'
*..s.r.4* I.I.S.7',1' *.i.s,?\f *,l.l,l',4` *.4.1,7'.*' *.4.5.*\S' *.4.(.?\4' *.4.l.7\4'.' M.S.r.r.S' 1.1.5,*'.4'.1' l.l,i,r,\C
44 11.1 K 4*
u 17 fl 47 11 IS *1 O 171 70.1 104 S 71 111 147
11*
.
-5fc
MONS 206223
DRAFT r
DO NOT QUOTE OR CITE
BEtATIVE INTENSITY
Figure I1-8. Mass Spectrum of Aroclor 1254.
t.4,* MCXACHLOflOSirfftllfL
M
kj M Xj
"T"
too t0
"it1o "
Figure 11-9. Mass Spectrum of 2,2*,4,4`,5,51 - Hexachlorobiphenyl.
-SI
MONS 206224
. . no NOT QUOTE OR RITE
with elimination of HC1 from the less chlorinated homoloques also
evident (60).
.
The molecular-ion peaks of the major biphenyl components are
-
easily distinguishable from those of the most common chlorinated
i
pesticides (73). For mixtures, it is possible to obtain separate
spectra by using a controlled temperature probe and by operating
at the temperature at which the components fractionally sublime;
for the PCB and DDT these are 24 and 67, respectively.
Nuclear-magnetic-resonance spectroscopy has also been used to
resolve the structures of some of the PCB isomers (74). Unequivocal
characterization of the components of technical PCB mixtures has also
been claimed based on the criteria of the availability of the pure
standard, GLC retention times on three different GLC columns, infrared
spectra and NMR spectra (75).
Some of the reactions of the fully chlorinated PCB, etc. could be
developed into confirmatory tests (76). Thus, decachlorobiphenyl reacts
at the 4,4`-positions in nucleophilic substitution reactions. The
halogens In these positions are activated so that they can be substituted
by more eletroposltive groupings.
Ultraviolet absorption spectra are also useful in confirming the
basic ring structure. The PCN can be differentiated from the other polychloro compounds by the long wavelength band at 305 nm. The PCDF have
a very characteristic UV spectrum. The spectra of the PCDD are given In
Table II-8 (24). In addition, the PCDDsgive a blue color reaction in concentra
H2S04 when treated with an oxidizing agent such as potassium nitrate (66,77).
HONS 206225
DRAFT
DO NOT QUOTE OR CITE
Table II-8.
Ultraviolet Spectral Data for Chlorinated Dibenzo-_-dioxins
chci3
Dibrnio^rtioYfn X X t
/i*
248 1020 293 36SO 0.278
l-Chluro2-CMoro-
2.7-Dichloro2,8-DichIoro2,3-Dichloro-.
248 1320 294 3190 . 0.414 248 1 NO 299 3700 O.JOS 2J7 1340 302 4390 0.292 247 1180 299 4690 0.232 247 1830 304 3(90 0.S7J
I,2.4-Yrirl>loro-
233 3290 294 2230 2.36
1.2.3.4-Tmac hloro-
237 6290 317 2290 2.75
2,?Y,K-Ycir'.irl>l(iro- 24S 2970 310 3590 0.332
l,3.6.$-Tciracl>Ioro>
230 3340 305 3440 1.61
1,2,3.4,7`lviuncltloro- 239 5920 306 2690 2.20
1,2.3.4.7.8-Hcxacliloio- 239. 3370 316 36(0 1.47
1,2.4,6.7.9-1 lirsacliloro. 259 4430 310 (480 3.01
Ociadiloro-
261 131 JO 318 2400 3.4$
-59-
MONS 206226
no ndtvuu.lOR cite
formation of a highly colored cation radical is characteristic of compounds of structureVn, where X can be D, S, Se or Te,
3ZET
The PCDDsalso show widely varying phosphorescent spectra which . can be used in characterization studies*' {See Table II-9). In addition,
all of the isomers are distinguished easily from one another by their infrared spectra and the PCDDscan be distinguished from the PCDF and PCDE by their characteristic mass spectral fragmentation patterns.
Confirmation of the structure of the PCB isomers could also be accomplished with the help of pulsed source-time resolved phosphorimetry (61). C. Afr
The vapor pressures, boiling points and distillation ranges of PCB technical mixtures give an indication which of these compounds will be found in the vapor phase and or in the particulate phase in the air (78). Thus, the distillation ranges of the Aroclors vary from 275 - 320 for Aroclor 1221 to 435 - 450 for Aroclor 1268. Anthracene and phenanthrena boil at 341 and 338, respectively, and. are probably, present in the atmosphere in the vapor phase since
-IpU -
HONS 206227
DRAFT
DO NOT QUOTE OR CITE
Table 11-9 . Phosphorescence Spectral Data for Chlorodibenzo-^-dioxins
Dibcnio-p-dioxin
r.vcila* lion, x
<<ntt)
Cffliulon bands, X (nm|
Unwbiliiuttd l-CliloroJ-Chloro2,71>ichloro2,8-DicliIoTO-
2,3-Dichloro1,2,4-Tnctilorol,2.>,4-Tclraehloro2,3,7,8-n e>rac hloro1,3,6,8-Tetrachloro.
Oclachloro-
294 3*6. 395.* 410. 41*. 426* 43*
296 396, 40'.* 422. 4 JO'
295 400.* 470
JOO 404 * 411426.43J. 4JS, 465
304 400/ 404/ 412, 420.42*. 432.
440. 450. 458
3)2 408. 4|8. 435"
304 412/ 418/ 427, 439-
J04 485* (scry broad)
-
30J 4) 1/ 418. 422. 436. 440. 448. 468
JOO 410/41*. 43?, 438, 465
310 433/ 45*. 490
* Strongest peak, k Peak not resolved.
-41-
MONS 206228
DRAFT
(10 NOT QUOTE OR CITE
they, are not usually collected on glass fiber paper with a high
volume sampler. Anyway, as far as this type of collection is
concerned, they are atmospheric vapors. This would mean that
Aroclor 1221 also could not be collected in this fashion.
Fluoranthene, pyrene and chrysene have boilina ooints of 384, 394 and 441, respectively, and are probably mainly
collected as particulate with a large portion not collected by
the filter. This means that Aroclor 1268 could be only partially
collected as particulate.
The importance of PCB In the atmosphere derives from the
spread of the PCB by air transport. The following sources are of
1 i I i'n 0 11
VI q I Pvi m
importance - [a) Manufacturing In the Sauget, S4. louis and Anniston,
A1abama plant^ of the Monsanto Co., (b) Evaporation from incineration
of refuse that contains PCB, (c) Use and wear of PCB containing
materials, (d) Leakage from closed systems, (e) Open air burning,
(f) Fine spray mist from the concentrated monomolecular layer of the
oceans and other bodies of water.
In a study of air over the North Atlantic ocean and in Bermuda
PCB could only be found in the vapor phase (79). None were found in
the particulates, although PCBs have been reported in selected urban
airborne particulate samples. A large amount of PCBs must get into the air. since it has been shown that 81% of Incinerator workers have PCB in their blood plasma (81).
Collection of PCBs has been accomplished by passage of air at 20-30
CFffr through ceramic chips coated with 0.1% OV-17 (79). PCO were not
HONS 206229
no r:or quote go cite
detected in a sample of marine air taken off the California coast (82). However, PCB fallout has been reported in southern Sweden. PCBs also have been detected in black snow in southern Sweden.
p
1 Certainly, a variety of good analytical techniques are now
available for the PCBs which could easily be applied to air analysis, but a good sampling method for atmospheric PCBs needs to be developed D. Water
The solubilities and the partition coefficients of the PCB are of prime importance in understanding the distribution of the PCB in aqueous systems. These physical constants have been discussed (84). Because of their low solubility and high adsorbability most of the PCB could be expected to be present in aqueous sludges or sediments. Similarly, tetrachloro DO, like ODT and higher PCB is soluble to the extent of 0.2 ppb and is strongly adsorbed on clay and organic matter. The solubilization of PCB in water by non-ionic surfactants as well as the determination of concentration of the solubilized PCB by UV spectrophotometry, fluorescence and GLC has been described (85). . Sampling of water solutions of the PCB has been accomplished by extraction with organic solvents (86), adsorption on activated carbon (87), collection by reversed phase liquid-liquid partition (88), collection on a porous polyurethane foam (89), and passage through a 3g. filter containing a mixture of p-undecane and Carbowax 4000 monostearate on Chromsorb W (88). Extraction is time-consuming and needs to be done in the laboratory. However, the process can be
hi HONS 206230
DRAFT
00 NOT QUOTE OR CITE
considerably speeded up and made more efficient by means of ultrasonic extraction. Recovery from ciiarcoal is variable and inefficient and the recovered material may be significantly different from the initial PCB. The reversed liquid-liquid partition filter gives excellent recoveries but is limited by low flow rates and requires elaborate preparation.
A recent method for collection and elution of PCB (89a) from seawater utilizes Amberlite XAD-2 Resin (XAD-2) (89b), a synthetic polymer of styrene and divinyl benzene which is further crosslinked and formulated into 20-50 mesh white beads. The claimed advantages of this material as compared to polyurethane and reversed phase liquid-liquid chromatography are that: (a) it is not compressible even at a depth of 1000 m, (b) there is no organic coating on the XAD-2 so that after elution of the column, it is ready to be reused, (c) chlorinated hydrocarbons are readily adsorbed from seawater, and (d) they are readily eluted quantitatively by 4 bed volumes of acetonitriU or ethanol.
Material collected on a solid material can be eluted with petroleum ether, cyclohexane or with acetone and hexane or ether and hexane. If necessary ultrasonics can be used to speed up the extraction. Another possibility is direct sublimation Into the GC. Ultrasonic extraction and sublimation have been found to be useful in our laboratories in the analysis of atmospheric PAH.
Although the extraction of PCB from sewage solids using a mixture of n-hexane and isopropanol,is probably less efficient I than extraction from water, many sludge samples were found to
i
- tv
HONS 206231
DRAFT r
. DO NOT QUOTE OR CITE
give gas-liquid chromatograms similar to those of PC8 mixtures (90) . Aliquots of concentrated extracts of California coastal waters contaminated by PCB from urban sewage outfalls have been analyzed by GLC using a ^Ni electron capture detector and a 3%
QF-1 column on 80 - 100 mesh, acid-washed, DMCS-treated Chromosorb
(91) .
^_
The occurrence and distribution of the PCB in the River Rhine
and the coastal areas of The Netherlands have been studied with
the help of GC-MS (21). Computer-controlled GC-MS has been used to
identify tetrachlorobiphenyls in a Los Angeles sewer extract (92).
The sensitivity of the method for aqueous PCB based on reversed
phase liquid-liquid partition between water and Chromosorb W
(coated with n-undecane and Carbowax 4000) is in the ppt range
(88).
Highly sensitive and reliable methods are needed for analysis
of water samples especially those obtained from the ocean since it
'.
has been reported that aqueous concentrations in the North Atlantic
are 35 ppt at the surface, 10 ppt at 200 meters and traces at 3000
meters (79). The lack of systematic analytical.procedures for the
characterization and determination of PCB in natural waters has
been pointed out In a recent review (93).
E. Soil
Very little work has been done in the study of the contamination of soil with PCB. It has been estimated that the half life of PCB soil Is of the order of five years while tetrachlorodibenzo-p-dioxin appears to have a lonn life in soil. The persistence of pesticides
-45-
MONS 206232
DRAFT
DO NOT QUOTE OR CITE
-
iff-soil has aroused considerable Interest in recent years, as evidenced by soil monitoring activities at local and notional levels
{94 - 98). The extraction of residues from soil is as important as
their determination since residues not extracted are not measured., .
The us. ual extraction methods make no provision for rupturing cells and liberating bound residues. Ultrasopic extraction has been used
. +
to obtain Insecticides from soil (99)and polynuclear aromatic
hydrocarbons from air particulate samples (100) efficiently and
quickly. The PCB could be extracted In the same way from the various
types of soil samples and further cleanup, characterization and assay would be by some of the procedures previously described. -
-fcfe-
MONS 206233
DRAFT
T. DO NOT QUOTE OR CITE
F. Food and Biological T issues 1, Introduction
The sampling and analysis of polychlorobiphenyls In biological tissues is essential for the establishment of the
i extent of their deposition and distribution In the biosphere. The food chain probably represents the major source of man's exposure to PCB's. This supposition can only be confirmed when the levels of PCB's In the environmental media. In man's food and In man himself can be accurately determined and correlated. The deposition, retention and metabolism Of PCB's In the human body must be determined before the potential hazard to human health can be assessed. Measure ment of PCB residues in wildlife is likewise necessary to ascertain what biota serve as "sinks" for PCB's and to what extent PCB's are a threat to the ecosystem.
While different sampling methods may be required for different biological specimens, the Isolation, cleanup and analysis methodologies for PCB's In foods and In plant, animal and human tissues and fluids will be essentially similar. For this reason, these laboratory procedures will be discussed In general and pertinent Information regarding specific sampling and analysis techniques will be discussed separately. 2. Isolation, Cleanup and Analysis
Polychlorobiphenyls are chemically similar to organochlorlne Insecticides. The methods of extraction, cleanup
-t7-
MONS 206234
DRAFT
. . DO NOT OUOTE OR CITE
and determination developed over many years for organochlorine pesticides are, for the most part, also satisfactory for PCB's. PCB's readily pass through the analytical schemes designed for the recovery of pesticides from plant and animal tissues and when present in sufficient quantities interfere with the determination of many of the chlorinated pesticides. In fact, the existence of PCB's in the environment was first discovered In this way^ and PCB
"contamination" continues to plague the pesticide residue
chemist. Several means of eliminating this mutual Inter
ference have been developed In recent years.
.
(a) Pesticides Residue Analysis
The most generally accepted methods for determination
of organochlorlne pesticides In biological tissues are those
published by the U.S. Department of Health, Education and
Welfare, Food and Drug Administration, In their Pesticide
Analytical Manual(lOl). There are essentially two procedures:
(1) For fatty tissue (both animal and plant), the
pesticides are extracted (along with lipids) from the ground
or chopped specimen with an organic solvent such as hexane.
The pesticides are then separated from the lipids by liquid-
liquid partitioning into acetonitrile. Column chromatography
on activated Florlsll (a magnesia-silica gel adsorbent
manufactured by the Florldln Company, Pittsburgh, Pennsylvania
1$ then utilized to remove remaining lipids and to fractionate
the pesticides Into groups to facilitate their Identification.
Finally fractions fron the Florlsil rolt'-n
nnn 1 *'r<->r| bv
gas chromatography coupled with an appropriate detector.
HONS 206235
DRAFT
[W MOT QUOTE OR CITE
Org.aoochlorlne pesticides can be identified and quantitatively
measured by either of two chlorine-specific detectors, the
electrolytic conductivity detector (102) or the mlcrocoulo-
metric titrator (103). However, due to the relatively low
*
i
sensitivity of these detectors (10-50)ng minimum detection
limits), the non-specific electron capture detector (5 to
100 pg minimum detectability, ref. 104 Is more often used.
(11) Non-fatty tissues (less than 10% fat) are
usually extracted directly with acetonitrile or some other
solvents. Otherwise, the methodology is the same as that
for fatty tissues.
,
(b) Separation of PCB's from Pesticides
In these procedures, polychioroblphenyls are
extracted from plant and animal tissues along with any
pesticides present. Some losses may result on acetonitrile
partitioning, however. Rlsebrough (105) cautioned that as much
as 30% of the rather nonpolar PCB's may remain behind In
the hexane layer. Reports of nearly quantitative recoveries
of Aroclors from fatty foods (29)suggest that efficient
partitioning is possible. It should be noted that the FOA
procedure (lOl)calls for partitioning four times. Recoveries
Of nonpolar pesticides such as aldrin are only about 70%
after the first partitioning. Chromatography on Florisil
will not allow separation of PCB's from many organochlorine
Insecticides.. The PCB's are eluted In the first fraction
(6% diethyl ether In petroleum ether or 20% methylene
-tv
HONS 206236
DRAFT
. !)0 NOT OIIOTE OR CITE
chloride, in hexane, depending on the method used) along
with most of the organochlorine pesticide group. Initial
elution with n-hexane has been used to effect a partial separation (21.28) but for the complete separation required
for analysis further steps are necessary.
The problem of separating PCB's from chlorinated
pesticides has been approached successfully from several
directions. The separation may be accomplished either by
physical or chemical means.
(1) Physical separations have been primarily
accomplished by liquid-solid absorption chromatography,
often in conjunction with Florisil cleanup chromatography.
Holden and Marsden
reported success with alumina
and silica gel (27). Synder and Reinert found silica gel
to be effective in separating Aroclors 1Z54 and 1260 from
DDT and its metabolites (106). Gel permeation chromatography
has been recently reported to be efficient and reproducible
for both cleanup and separation of PCB's from organo
chlorine pesticides (107). a still more recent paper
describes the use of activated charcoal (63). Extracts
are adsorbed In a column of cocoanut charcoal. An ether-
acetone mixture is used to remove the DDT group of pesticides
- (with 91-94% efficiency) and benzene serves to elute PCB's
(90% efficiency). Oils or fatty extracts can be removed by
Florisil cleanup after the charcoal separation.
A technique developed by Armour and Burke of
the FDA (29) 1, r, nov* beer, incorporated 1 rto the Pesticide
- 7o -
HONS 206237
DRAFT
.DO NOT QUOTE OR CITE
Analytical Manual (100). This technique employs column
chromatography on silicic acid-Celite after the Florisil
cleanup.
Thin-layer chromatography has also been used
to separate PCB's from pesticides. Probably the most
widely used method is that of Mulhern et al. (35), After
Florisil cleanup, the 6% ether-pct-ether fraction is thin-
layer chromatographed on alumina G impregnated with silver
nitrate. The PCB's accumulate in one spot, visible after
exposure to ultraviolet light, and are estimated semi-
quantitatlvely by visual comparison to a standard of
Aroclor 1260. Another method is based on two-dimensional
thin-layer chromatography (38).
Reversed-phase paper chromatography has also
been used successfully to separate -PC8's from chlorinated
pesticides and their metabolites (109). The former exhibit
much lower R^ values.
(11) The other means by which Interferences by
some organochlorine pesticides can be eliminated Is by
chemical alteration. The PCB's resist alteration due to
their high chemical stability. The most common methods used
are nitration (28,110) and dehydro-chlorination of the
pesticides (111), Both of these methods have draw-backs
in that they do not eliminate all chlorinated pesticides;
the products produced may have long GC retention times and
thereby cause analytical problems; and some of the PCS
Isomers may also
al.
Tr.: ,j u ......
imric
-II-
MONS 206238
- DO NOT QUOTE OR CITE
ac1d"i$ known to nitrate some of the lower chlorinated
biphenyls and will not affect some pesticides, such as
toxaphene, lindane, y-BHC or strobane (112) Dehydrochlorin
ation with alcoholic potassium hydroxide will eliminate
DDT and DDD, but not the important interferent DDE (in fact.
It may produce It). Fuming sulfuric acid can also be used
to eliminate Interference by aldrin, DDT, DDD and DDE, but
not lindane or heptochlor epoxide (83).
A recently reported method takes advantage of
the high thermal stabilities of PCB's to eliminate them as
interferences In the determination of organochlorine
pesticides (113). In the Coulson electrolytic conductivity
detector chlorine-containing organic compounds are pyrolyzed
In a hydrogen atmosphere as they exit from the gas chromato
graph. The hydrogen chloride produced Is passed through
de-lonlzed water and measurement of electrical conductivity
Is used to determine the Initial amount of compound present.
Under the normal operating conditions (850C), both PCB's
and chlorinated pesticides are pyrolyzed. However, at
600C, the PCB's are not burned and will, therefore, produce
no response. In this manner, PCB's may be determined by
differences,
c. QuantlfIcation
Once PCB's have been isolated from biological media
and Interfering organochlorine pesticides, the problem then
arises as to how to quantify them. There are 210 possible
compound- of
i.u uecacnloriniitod uiphuiyl (72).
-m-
MONS 206239
DRAFT
. . DO NOT QUOTE OR CITE
Commercial preparations, such as the Aroclors, are complex mixtures of many chlorinated biphenyls. A gas chromatogram of a given Aroclor will reveal many peaks and any given peak may represent a number of different isomers and/or chlorine homologs of chlorinated biphenyls. Once released into the environment, the composition of a commercial preparation will change since the different*PCB compounds contained therein have different volatilities, solubilities and stabilities to chemical and metabolic breakdown. It is highly unlikely, for example, that Aroclor 1254 will be found in any environmental sample. A distribution of PCB's tending to match an Aroclor 1254 standard may be detected, but that would not mean that the sample was exposed to that particular Aroclor. In fact, even the composition of Aroclor 1254 (or any other Aroclor) will vary slightly from batch to batch. Yet, for lack of better methodology or lack of understanding, nearly all residue analysts in the United States try to identify and quantify PCB residues as particular Aroclors.
Estimation is usually accomplished by: (1) "Fingerprint matching" with a known PCB Standard and summation of all components detected (114); (ii) Using the average of two peaks U8); (iii) .Comparison to p.p'-DDE using electron capture detection (30); or (1v) Comparison to the peak in Phenoclor DP6 which has a t*C k C l. L i Oil LiliiU t'UluLlVii lu Umbi'id ui t,-.y (ii/.
HONS 206240
13
00 NOT QUOTE OR CITE
Electron capture detection (ECD) Is most often used In each case. Another method which Is perhaps better Is that of Rote and Murphy (20). These investigators prepared electron capture response curves of total peak area per
1' nanogram for six Aroclors versus the average number of
i chlorine atoms per molecule for each Aroclor. Unknowns were then compared to this response curve for identification and quantification. Of course, such response curves would, have to be prepared frequently to assure accuracy. ' In all of these methods, as well as in the thin-layer chromatographic methods previously mentioned, the PCB's are determined as an Aroclor (or Its European or Japanese counter part), which has no real meaning. .
Isomeric groups of polychloroblphenyls can be detected by mass spectroscopy. It Is possible, therefore, to deter mine the amounts of tetrachloro-, pentachloro-, hexachlorobiphenyls, etc. in a PCB mixture (92,115), By combined gas chromatography-mass spectroscopy (GC-MS), the molecular weight and chlorine number associated with each peak can be ascertained. Elucidation of the structures of the many Individual isomers is a very difficult task, particularly since chromatographic separation prior to analysis is not possible.
Perhaps the most valuable application of mass spectros copy to PCB and pesticide residue analysis is as a confirmatory tool. Although GC-MS Is one or more orders of magnitude loss s r ni + i th^n r-C-rfr fr-" PrlJ's, it h'S sensitivity
HONS 206241
. 00 NOT quote Of? CITE
as good or better than other chlorine-sensitive detectors
and it Is far more specific. Hass spectroscopy Is often the
only way by which the Identity of a trace pollutant can be
established. Mass spectrometers are not, however, simple to i
operate. Computer operation and data Interpretation Is
usually required, with very expensive Instrumentation the
result.
...................
The problem of the multi-component nature of PCB's can
.be circumvented by chemical conversion to a single compound
and at the same time a large Increase In sensitivity can be
achieved. There are two methods: dechlorination to biphenyl
(63,116,68) and perchlorlnation to decachloroblphenyl (63).
By these methods all Isomers and chlorine homologs are
converted on one chemical entity which allows determination
of the total PCB content of the sample. Problems with Identi
fication, Interference and detection limits are reduced since
one peak Instead of many is obtained from the gas chromatograph.
Dechlorination (usually with hydrogen over platinum or
palladium) Is less advantageous In that the product Is a
hydrocarbon and can be measured only at a relatively low level
of sensitivity. Perchlorination with antimony pentachloride
yields fully chlorinated biphenyl for which chlorine-specific
and electron capture detectors should be most sensitive.
At the microgram level yields are reported to be 85 5% (63).
On gas chromatography using SE-3D, the decachlorobiphenyl
peak is well removed from those of commsn chlorinated pesti
cides (44). Ihe perdu orinan on proceuure, inure rore, oi rm-s
-1S-
HONS 206242
much.promise for the solution of of analysis and quantification of PCB's. Confirmatory
/
analysis, usually very difficult at the residue level. Is also greatly simplified. 3. Foods
Extraction and cleanup methodologies suitable for analysis of PCB residues in food products are provided In detail In the FDA's Pesticide Analytical Manual (101); the USDA's Chemistry Laboratory Guidebook (117), the "Guide to the Analysis of Pesticide Residues" published by the U. S. Public Health Service (118), the Canadian Food and Drug Directorate's "Analytical Methods for Pesticide Residues in Foods" (119), and the Official Methods of Analysis of the Associates of Official Analytical Chemists (120).
Instructions for the collection of food and feed samples for pesticide residue analysis are given In the FDA Inspectors Programs Manual. Total composite samples of approximately 20 pounds are collected from retail units, warehouses and transport vehicles. Additional specifications are given for sample sizes for selective samples such as raw agricultural products, milk, eggs, meat, etc.
The Manual also covers sample preparation, as does the Pesticide Analytical Manual (ref .101, Secti on 141). Inedible and decomposed parts, soil, waxes, etc., are removed from raw agricultural products and discarded. In the case of processed foods, packing liquors are analyzed only if
-?fe-
HONS 206243
.
.
DRAFT r
. DO NOT QUOTE OR CITE
normally consumed and dehydrated or concentrated foods are
not reconstituted prior to analysis. Heats and other fatty
foods are ground or blended, usually with anhydrous sodium
sulfate for drying, and extracted with petroleum ether. The extract Is dried to recover the fat. The fat Is then
redissolved In a minimum quantity of petroluem ether and
the pesticides (or PCB's) are partitioned out Into acetoni
trile. Cleanup and separation procedures described previously
are utilized. Sweep-codistl11atlon of pestlcldal compounds
from edible fats and oils Is sometimes employed (121). Non
fatty foods (fruit, green vegetables, berries, corn meal,
potatoes, wheat, etc.) are analyzed In much the same manner.
The primary difference Is that extraction and partitioning
are done In one step. The commodity Is usually blended with
acetonitrile, filtered. Sodium chloride solution added, and
then extraction with petroluem ether Is carried out. Milk
requires some special treatment. Whole milk Is mixed with
an equal volume of ethanol or methanol and sodium or potassium
oxalate Is added. After further dilution with aqueous sodium
chloride. It Is extracted with a 1:1 mixture of petroleum
ethtr and diethyl ether. Partitioning Into acetonitrile and
Florlsil cleanup follows this treatment.
The latest addition to Volume I of the FDA Pesticide Analytic-,! Manual describes a method for exhaustive extraction
of organochlorlne residues in foods and feeds (Section 253,
September 1, 1972). Soxhlet extraction Is employed in place
of cold E .'-.v E . ... Fur suli.d foods. A 1:1 Mixture of
chloroform and methanol is substituted for petroleum ether.
HONS 206244
DRAFT
. DO NOT QUOTE OH CITE
The method was first reported by Porter ct. al_. (GO)
for
f1st\, meat and poultry.
Cold extraction with a 1;1 mixture of hexane and Isopro
panol, followed by benzene, was used by Skrentny et_ a_l_. (122)
to recover PCB's from homogenized corn silage. Florisll
chromatography was employed for cleanup, with elution by
hexane used to partially separate the PCB's from chlorinated
pesticides.
.
'
Bellman and Barry (123) applied combined gas chromatography-
mass spectroscopy to the determination of PCB's In several
food products. The standard FOA Isolation and cleanup
methodologies were utilized. However, these Investigators
were unable to detect PCB's In any samples.
In the examination of food commodities as sources of
polychloroblphenyl Injestlon by humans. It would seem to be
advisable to prepare the foods sampled In the manner In which
they are normally prepared for consumption. Although PCB's
are quite stable thermally and have only slight water
solubilities, there Is undoubtedly some loss on cooking.
When only trace quantities are present, these losses could
be very significant. This problem does not appear to have
been addressed in the literature.
' 4* Animal Tissues
.
Most sampling of animal life for polychlorobiphenyl
determination has been on marine fauna and predatory birds
(especially sea birds). There is no standard for collection
or tissue rp.'civ.ciis . . 1 i :. I
......... ..
-Tfi-
HONS 206245
. DO NOT QUOTE Ott CITE
the same types of tissues in different species of animals.
Adipose tissue (fat) appears to be a repository for '* PCB's in animals, although high levels have also been found
in liver of the white sharks (124). Some animals possess two
types of adipose (brown and white) in which the rates of
metabolism differ greatly. For an accurate assessment of
PCB residues in animals, careful consideration must be
given to the selection of tissue(s).
.
Methods of preservation of specimens between collection
and analysis have varied from study to study. Some analyses
have been performed on animals in rather advanced states of
decay (57). Although PCB's are generally quite resistant to
degradation, chemical and bacteria breakdown in unpreserved
samples could result In losses. Other decay products may
also 1nterfere with PCB determinations. Tissue or whole
specimens should, therefore, be frozen, preferably with
Dry Ice, until analyzed. Under no circumstances should
chemical preservatives such as formaldehyde be used. Care
Should also be given to selection of storage vessels.
Contamination by PCB's or other interfering organics could
result from storage in plastic containers (although poly
ethylene bags may be acceptable).
Preparation of samples for analysis also varies greatly.
Samples may be extracted wet (with quantification of data
based on wet weight) or lyophilized before analysis. It Is
desirable to determine residue levels in terms of dry weight;
HONS 206246
DRAFT
_ DO NOT QUOTE OR CITE
however, drying by lyophi1ization may result of losses from volatilization. In the analysis of fatty tissues, the fat can be extracted along with the PCB's, separated and weighed for quantification of the PCB's in terms of dry weight of adipose tissue.
Analytically, the same methodologies which apply to the determination of organochlorine residues in fatty foods should serve equally well for all animal tissues. In addition, the FDA Pesticide Analytical Manual offers a general method for determination of chlorinated organic residues in human or animal adipose tissue (Volume III, Section HE211). This method is discussed under Section III, 6 of this paper.
Duke et. aj_. (125) analyzed fish, crabs, and oysters for PCB's using essentially the FDA procedure for foods except that extractions (with petroleum ether) were carried out in Soxhlet apparatus. These investigators reported the PCB's found In the first fraction from the Florisil cleanup as Aroclor 1254.
Koemen et_ aj_. (21) used nearly the same method in Isolating and determining PCB's In fish, mussels and birds. In this case dimethyl-formamide was substituted for acetonitrile in the partitioning step. DeVos and Koeman also employed the same technique for chickens (126).
- Armour and Burke (29), Synder and Reinert (106) and Zitko (127) used silicic acid chromatography, following conventional cleanup methodologies, to separate PCB's from chlorinated pesticides in the nne'lysis of various species of
HONS 206247
DRAFT
DO NOT QUOTE OP CITE
flsK.' Zitko ct aK (124) utilized the same methodology in
the analysis of mussels, liver, fat and other tissues from
fish and sea birds and their eggs. Gel permeation chromatography has been employed and
Stalling et_ aj_. (107,128) for preparation of fish samples for
PCB analysis (See Section III, 2).
Risebrough (56) removed DOT compounds as Interferences
In the determination of PCB's.in birds and fish by nitration
and saponification, then quantified the PCB's by comparison
to a p,p'-DDE standard using electron capture detection and
mlcrocoulometry.
Grant et aK (54) analyzed blood, liver, kidney, testes,
heart, brain, spleen and fat samples from rats dosed with
Aroclor 1254. Tissues were blended with hexane and anhydrous sodium sulfate, and the extracts were treated with fuming
sulfuric acid before analysis by GC-ECD. PCB concentrations
were calculated on the basis of wet tissue weights.
Liver samples taken from sea otters were digested In a
perchloric-acetic acid mixture and the fat extracted with
hexane in work reported by Rote and Murphy (20). FDA cleanup
procedures and silicic acid-Celite separation were used.
Destructive chemical treatments such as those employed
in the previous three studies are risky In that some unv/anted
alteration of PCB's may be effected.
Widely different results may be obtained with different
methods of quantification. For example, Risebrough and de
(K J
tv*. ^1,1 w 0 L. ^ ^ , fel.C L^i.uiull I L.TUI
HONS 206248
DRAFT
DO NOT QUOTE OR CITE
using two different methods. When the areas of PCB peaks emerging after p,p'-DDE on the gas chromatogram (ECD) were compared with an Aroclor 1254 standard, concentrations of 3Ofl and 214 ppm were calculated for the egg lipids. Comparison of the areas to the total area of the same peaks In an Aroclor 1260 standard, the values obtained were less than one-half of those calculated by the first method. Various quantitation techniques can lead, therefore, to widely differing results between laboratories.
PCB concentrations In Atlantic zooplankton were also reported by the above Investigators (129). Levels ranging from 2 to 260 ppm were measured in lipids extracted with 2:1 hexane:acetone In a Soxhlet apparatus. 5. Plant Tissues
Most reports of PCB determinations In plant tissues have been on raw agricultural food products. Very little examination of non-agrlcultural flora has been undertaken.
Suitable analytical methodologies would be those designed for non-fatty foods discussed In Section III, 2 and III, 3 of this paper. Collection procedures would depend on the nature of the study. If environmental transport via food chains Is of principal concern, plant life which serve as primary food sources for animal wildlife would be sampled. Edible portions would be taken, preserved and prepared for analysis. Preservation of plant samples Is generally less troublesome than that of animal specimens,
HONS 206249
DRAFT
DO NOT QUOTE OR CITE
since decay is less rapid In the former. However, samples should be kept cool or preferably frozen until ready for analysis.
Perhaps the most Important plant life for PCB accumu lation and distribution along the food chain Is marine flora. The common marine phytoplankton Cyl1ndrotheca closterlum has been found to concentrate PCB's present In water by a thousand-fold or more. Fish feeding on this diatom receive far more PCB's than they would otherwise extract from water and pass them along to man and other fish-eating animals. Kell et aK (52) determined the uptake of Aroclor 1242 by C. closterlum by lyophllizlng the sample, extracting with acetone and analyzing by gas chromatography. Identification was achieved by comparison of the relative retention times of the five major peaks. As previously mentioned, lyophi1Izatlon could have resulted In losses of some PCB's from the sample and should be avoided. Centrifugation or filtration followed by air drying would have been preferable. It should be mentioned here that there Is some evidence (52) that PCB's may inhibit photosynthesis In marine phytoplankton, which represent an Important contribution to the world oxygen reserve. Varying sampling techniques for ocean plankton can lead to poor reproducibility and other problems (130). Samples are usually collected in nets. Mesh sizes vary and often no attempt is made to exclude sea-surface debris. Paint, oil and tar particles may be collected In the process.
-8`5
HONS 206250
' ,,,, DRMT 00 NOT QUOTE OR CITE
6. Human Tissues and Fluids Analytical methodologies suitable for PCB assay in human
tissues are described In Section 111 2 and III* 4 of this paper. In addition, Volume III of the FDA Pesticide Analyti cal Manual (131) Is concerned with methods for organochlorine residues in human media. The U. S. Environmental Protection Agency has also conducted a nationwide human monitoring program for pesticides and PCB's (132). Analytical methods for that program have also been published (133).
The most commonly used method for Isolation and cleanup of PCB's for human tissue Is a modification of one devised by Mills (134) for pesticides in adipose tissue. The procedure Is detailed in the Pesticide Analytical Manual (131). Adipose Is ground with anhydrous sodium sulfate and sand, extracted with petroleum ether, filtered and weighed. The lipid extract Is redissolved In petroleum ether and the organochlorine compounds are extracted Into acetonitrile by liquidliquid partitioning. Further cleanup and fractionation Is accomplished by conventional Florisil chromatography. Polychloroblphenyls and nonpolar organochlorine pesticides are eluted from the Florlsll column with a mixture of 6% diethyl ether In petroleum ether. The chlorinated pesticides are ` removed by chromatography on silicic acid. The same or similar methodologies are applicable to liver, kidney, bone marrow, adrenal, gonads, brain and blood.
When tissue quantity is limited or when levels of
Clrl f:r : j ' <[' i............... ...................................................................................... ;............... .ii^i i S
* Vh-
MONS 206251
DRAFT
. , DO NOT QUOTE OR CITE
avafTable (131). As little as 50 mg of tissue may be avail able from autopsy and biopsy samples.. With the micro procedure 10 ppb of a given organochlorine compound can be detected cn this size sample. The main difference between the micro and full-scale methods is a revisal of the extraction and partitioning schemes. In the micro method, acetonitrile Is used for extraction, which*in turn* is diluted with water, and the pesticides and.PCB's are then partitioned into hexane. Chromatography on a micro Florlsil column calls for elution with hexane, followed by IS methanol In hexane. For brain tissue, the concentrated hexane extract Is treated with acetic anhydride and pyridine at 60-G5*C, probably to release phospholipids.
Biros al_. (70) utilized the modified Hills procedure (131,134) to isolate PCB's from human adipose tissue. The presence of PC8's was determined by electron capture and mlcrocoulometrlc gas chromatography and mass spectroscopy was used for Identification and quantitation. These workers used a stainless steel capillary column coated with 0V-1 in their GC-HS studies. It should be pointed out that organo chlorine compounds can decompose on hot stainless steel surfaces so that caution should be exercised In using this method.
In a Japanese study (135) PCB's were determined in the skin of a still-born infant poisoned by Kanoclor400 (a mixture of d1 -, tri-, tetra- and pentachlorobiphenyl with an
3VCl'j(jC LlllJriU*.' CLtl vlil l U i 1
i fit' b u <1 u c nu)
-85-
HONS 206252
DRAFT
.00 NOT QUOTE OR CITE
Into.small pieces and extracted separately with ethanol,
ether and hexane. Partitioning into acetonitrile and
Florisil cleanup were then carried out according to FDA
procedures (131). Collection of tissue samples from human beings Is
somewhat more complicated than in the case of wildlife.
Sufficient quantities of tissues are rarely available from
living subjects. Hair and body fluids are readily available
but do represent Ideal media for assessing PCB uptake and
accumulation by humans. Autopsy materials, therefore, offer
the best source for such studies.
The question then arises as to what tissues to sample
and from what portion of the organ they should be taken.
On this question, there seems to be considerable disagreement
among biochemists, pathologists and others.
A recent protocol for the collection of autopsy tissue
sets has been established by the U. S. Environmental
Protection Agency for the Community Health and Environmental
Surveillance System (136). This protocol calls for the 19
different tissues, including hair, fat, muscle, bone and
vital organs, from autopsies. Stlllborns, victims of homo-
cldes, suicides, accidental poisonings and embalmed bodies are excluded. Tissues are placed Into Zlplok plastic bags
(polyethylene) and frozen as soon ar possible after removal
from the body. (Comments regarding sample preservation and
preparation for analysis are presented In Section III, 4 of
%. i J 1
y . ** . ,. , 1 : .! b -- T r L 0 i li . .
v . (ITU L U .1: U 1* u ^
for the autopsy.
-8b-
HONS 206253
DRAFT
. DO NOT QUOTE OR CITE
-Since it Is often not possible or desirable to collect
and/or analyze an entire organ, consideration was given as
to what portion of that organ should be sampled in order to
provide a representative specimen. On this there is little
agreement apparent among workers in the field (137). For
pollutant accumulation and storage studies, however, agree
ment that subcutaneous fat-from the peritoneum is most
valuable.
*
'
HONS 206254
. DO NOT QUOTE 00 CITE
G. Source Sampling and Measurements (138) '
According to Nisbet and Sarofini possible routes of PCB entrance
Into the environment include leaks and spills from sealed equipment, losses
In manufacture, vaporization or leaking from PCB formulations and waste
disposal of PCB and PCB containing products. Incineration of waste is
probably the only route which presents a.configuration convenient for making
direct, in-stack source emission measurements. For diffuse sources such
as open dump burning, accurate emission data are virtually impossible to
obtain. The usual practice is to use ambient sampling and analytical pro
cedures in the vicinity of the source and to apply estimates of thermal
and turbulent diffusion, deposition, etc. to derive an approximate emission
rate.
No data are available on the amount of PCB that escapes Into the atmos
phere with combustion products from municipal and commercial Incinerators.
Monsanto reports that PCB may be completely destroyed when incinerated at
800C for 10 seconds and it has been postulated that municipal incinerators
would not be a major source. Nevertheless, no data are currently available
to confirm this and it is possible that poorly operated industrial and
municipal Incinerator may be significant sources of emission. .Often
hearth Incinerators do not provide the preferred form of incineration due
to possible vaporization of PCB on the drying grate and by-passing the
flame zone in units wh^.re adequate mixing is not provided.
The possible formation of highly toxic chlorinated dibenzofurans
(CBDF) and -d--i-b--e--n--z- o-dioxines in the burning of waste (6co) ntaining chlorinated phenols and PCB should be investigated. Vos, et_. al_ suggest that the
HONS 206255
00 HOT QUOTE OH CITE
purification of PCB by a procedure involving blowing oxygen through the heated'product may be the source of the extremely toxic CBDF found in some of the manufactured products. Current chemical techniques are not sufficiently sensitive to detect quantities that might be environmentally significant (sub nanogram or even sub picogram). Attempts should be made to determine If detectable amounts of the chlorinated dibenzofurans or dibenzodioxines are present at burning sources where there is a potential for incomplete pyrolysis and there are relatively rich levels of PCB or chlorinated phenyl i n the refuse. *
Although source sampling measurements on PCB have not been reported, sampling systems for detecting pesticides have been used. Stanley, et. aT (139; used a sampling train composed of a glass filter, a Greenburg-Smlth Impinger containing hexglene glycol and an adsorbent tube filled with alumina to detect various pesticides. The distribution of the pesticide through the three components was determined. At higher concentrations (417 ng/m-^), the per cent on the filter was highest. At lower concentrations the distribu tion was spread more evenly throughout the train. Caution should be exercised before reaching conclusions regarding the form of the pesticide based on the component on which it is collected. Collection efficiency
. 140 studies by Miles et. al_ revealed that large retention percentages were found when vaporous pesticides were passed through glass, paper or membrane filters.
-ss-
MONS 206256
DRAFT
DO NOT QUOTE OR CITE
H. REFERENCES
' (R)
I. Halowax
Chlorinated NaDhthalenes, Technical Bulletin, Koppers Co.,
Inc., Tar Products Division, Pittsburgh, Pa.
2. S. Jensen, New Scientist, 32, 612 (1966).
3. R. W. Risebrough, P. Reiche, D. B. Peakall, S. G. Herman and M. N. Kirven, Nature, 220, 109B (1968).
4. J. Armour and J. Burke, Preliminary Report in PCB Newsletter, No. 3,
July 1971.
...................
-
5. A. V. Holden. Pesticides Monitor J.. 4_, 117 (1970).
'
6. J. G. Vos, J. H. Koeman, H. L. van der Maas, M. C. Ten Noever de Brauw and R. H. de Vos, Fd. Cosmet. Toxicol.. B, 625 (1970).
7. V. Zitko and P. M. K. Choi, Fish Res. Board Canada Tech. Rep... 272. 1 (1971 )
(r) ; --
8. Aroclor
Plasticizers, Tech. Bulletin, 0/PL 306, Monsanto Co., St. Louis,
Mo.
9. V. Zitko, Intern. J. Environ. Anal. Chem., 1_, 221 (1972).
10. 0. A. Elvidge, Analyst. 96, 721 (1971).
11. K. S. Brenner, K. Mueller and P. Sattel, J. Chromat., 64, 39 (1972).
12. D. Firestone, J, Ress, N. L. Brown, R. P. Barron and J. N. Damico, J. Assoc. Off. Anal. Chemists, 55, B5 (1972).
13. B. D. Kimbrough, Arch. Env. Health, 25, 125 (1972).
14. G. R. Higginboteham et al. Nature, 220, 702 (196B).
15. S. Jensen and L. Renberg, Presented at the NIEHS Conference on Chlorinated Dibenzodioxins and Dibenzofurans, Research Triangle Park, N. C., April 2-3, 1973.
16. D. G. Crosby, K. W. Moilanen and A. S. Hong, Presented at NIEHS Conference on Chlorinated Dibenzodioxins and Dibenzofurans, Research Triangle Park, C., April 2-3, 1973.
<-
17. D. G. Crosby et al. Science. 173, 748 (1971).
18. 0. Hutzinger, S. Safe and V. Zitko, Bulletin Env. Contain. Toxicol., 6,
209 (i971J.
;:
"
19. A. C. Tas and R. H. de Vos, Env. Sci. Techno!., 1216 (1971).
MONS 206297
DRAFT
. . 00 NOT QUOTE OR CITE
20. J. W. Rote and P. G. Murphy, Bulletin Env. Contain. Toxicol., 6, 377.(1971).
21. J. H. Koeman, M. C. Ten N. de Brauw and R.' H. de Vos, Nature, 221, 1126 (1969).
22. R. G. Webb and A. C. McCall, Presented at the 16th National ACS Meeting, New York, Aug. 29, 1972.
23. V. ZTtko and P. M. K. Choi, Fisheries Research Board of Canada Technical Report No. 272, 1971.
24. A. E. Pohland and G. C. Yang* J. Agr.-Food Chem., 20, 1093 (1972).
25. M. G. Broadhurst, Env. Health Perspectives, 81 (1972).
'
26. E. P. Lichtenstein, K. R. Schulz, T. W. Fuhremann and T. T. Liang, J. Econ. Ent., 62, 761 (1969).
27. A. V. Holden and K. Marsden, J, Chromat., 44, 481 (1969). .
28. L. M. Reynolds, Bulletin Env. Contam. Toxicol., 4, 128 (1969).
29. J. A. Armour and J. A. Burke, J. Assoc. Off. Anal. Chemists, 53,
761 (1970).
1!
30. R. W. Risebrouqh, P. Relche and H. S. Olcott, Bulletin Env. Contam. Toxicol., 4, 192 (1969).
31. R. L. Stanley and H. T. LeFavoure, JAOAC, 48, 666 (1965).
32. P. G. Murphy JAOAC, 55, 1360 (1972).
33. A. Bevenue and J. N. Ogata, J. Chromat., 50, 142 (1970).
34. M. L. Porter and J. A. Burke, J. Assoc. Off. Anal. Chemists, 54, 1426 (1971).
35. B. H. Mulhern, E. Cromartie, W. L. Reichel and A. A. Belisle, J. Assoc. Off. Anal. Chemists, 54, 548 (1971).
36. G. B. Collins, D. C. Holmes and F. J. Jackson, J. Chromatog., 71, 443 (1972).
37. G. Westoo and K. Noren, Acta Chem. Scand., 24, 1639 (1970).
38. N. V. Fehringer and J. E. Westfall, 0. Chromaton., 57, 397 (1971).
39. R. H. de Vos and E. W. Put, Bulletin Environ. Contam. Toxicol., 6, 164 (1971).
HONS 206258
DKAH
' DO NOT QUOTE OR CITE
40. D. C. Holmes and M. Wallen, 0. Chroma tog., 71 , 562 (1972).
41. D. F. Goerlitz and L. M. Law, Bulletin Env. Contain. Toxicol.,
7,'243 (1972).
"
42. J. A. Armour and J. A. Burke, JAOAC, 53, 175 (1970).
43. D. T. Williams and B. J. Blanchfield, J. Assoc. Off. Anal. Chemists.
54, 1429 (1971).
~
44. V. Zitko, 0. Hutzlnger and S. Safe, Bulletin Env. Contain. Toxicol..
6, 160 (1971).
~
45. V. Zitko, 0. Hutzlnger, W. 0. Jamieson and P. M- K. Choi, Bulletin
Env. Contam. Toxicol., 7_, 200 (1972).
46. R. F. Addison, G. L. Fletcher, 5. Ray and J. Ooane, Bulletin Env.. Contam. Toxicol., 8, 52 (1972).
47. Polychlorinated Biphenyls - Environmental Impact, Env. Res., 5, 339
(1972).
"
48. FOA, Pesticide Analytical Manual, Vol. I (1968).
49. Official Methods of Analysis, 11th ed. Association of Official Analytical Chemists, Washington, D. C. (1970).
50. M. L. Porter, S. Young and J. A. Burke, J. Assoc. Off. Anal. Chemists,
53, 1300 (1970).
"
51. K. Vermeer and L. M. Reynolds, Can. Field-Naturalist, B4, 117 (1970).
52. J. E. Keil, L. E. Priester and S. H. Sandifer, Bulletin Environ. Contam. Toxicol., 6, 156 (1971).
53. I. Prestt, D. J. Jeffries and N. W. Moore, Env. Poll., 1_, 3 (1970).
54. D. L. Grant, W. E. J. Phillips and D. C. Villeneuve, Bulletin Env. Contam. Toxicol, 6_, 102 (1971).
55. D. J. Hansen, P. R. Parrish, J. T. Lowe, A. J. Wilson, Jr. and P. D. Wilson, Bulletin Env. Contam. Toxicol., 6^, 113 (1971).
56. R. W. Risebrough in M. W. Miller and G. G. Berg, Eds. "Chemical - Fallout", C. C. Thomas Publishers, Springfield, 111. 1969.
57. J. Jensen, A. G. Johnels, M. Olson and G. Otterlind, Nature, 224, 247 (1969).
58. A. Richardson, J, Robinson, A. N. Crabtree and M. K. Baldwin, Pesticides Monitoring J., 4_, 169 (1971 ).
MONS 206259
DRAFT .
DO NOT QUOTE OR CITE
59. N. L. Gregory, J. Chem. Soc.. (8), 295 (1968).
60. 'O'. Hutzlnger, S. Safe and V. Zitko, Analabs Research Notes,
12,. 1 (1972).
.
61. C. M. O'Donnell, K. F. Harbaugh, R. P. Fisher and J. D. Winefordner, Anal. Chem., 45. 609 (1973).
62. A. Weber and C. Sollsher, Ber., 16, 882 (1883) .
63. 0. W. Berg, P. L. Diosady and A. V. Rees, Bulletin EnvTr, Contam. Toxicol., 7, 338 (1972).
64. D. T. Williams and B. J. Blartchfield, JAOAC. 55, 93 (1972).
65. D. T. Williams and B; J. Blanchfteld, JAOAC, 55, 1358 (1972).
66. M. Tomita, S. Ueda and M. Narisada, Yakuqaku Zasshi, 79, 186
(1959).
'
67. L. Denivelle, R. Fort and P. Van Hai, Bulletin Soc. Chim. France,
1538 (1960).
::
68. R. T. Asai, F. A, Gunther, W. E. Westlake and Y. Iwata, J. Aqr. Food Chem., 19, 396 (1971).
69. R. G. Webb and A. C. McCall, JAOAC. 55 746 (1972).
70. F. J. Biros, A. C, Walker and A. Medbery, Bulletin Env. Contam.
. Toxicol., 5, 317 (1970).
'
71. G. E. Bagley, W. L. Reichel and E. Cromartie, J. Assoc. Off. Anal. Chemists. 53, 251 (1970).
72. G. Widmark, J. Assoc. Off. Anal. Chemists, 50, 1069 (1967).
73. 0. Hutzlnger, W. D. Jamieson and V. Zitko, Nature. 226, 664 (1970).
74. D. Sissons and D. Welti, J. Chromatog-, 60, 15 (1971).
75. A. C. Tas and R. J. C, Kleipool, Bulletin Envir. Contam. Toxicol., 8, 32 (1972).
76. F. Binns and H, Suschitzky, J. Chem, Soc.. (C), 1913 (1971).
'77. M. Tomita and 5. Ueda, Tetrahedron Letters, 18, 1189 (1963).
78. Ref. 47, pp 266 - 268, 270.
79. G. R. Harvey, Woods Hole Oceanographic Institute, Personal
Communication.
HONS 206260 ^3
DRAFT
. no not nunrc no htf
80.- I. C. Nisbet and A. F. Sarofim, Env. Health Perspectives, J_, 21 (1972).
81. D. I. Hammer et al Envir. Health Perspectives. 83 (1972).
82. R. W. Risebrough, et al, Science, 159, 1233 (1968).
83. 8. Persson, Ornls Scandinaira, 2, 127 (1971).
84. Ref. 47, pp. 262, 268.
.
.
85. V. Zitko, Bulletin Envlr, Contam, Toxicol., , 279 (1970).
86. L. Kahn and C. H. Wayman,~Ana1. Chem., 36, 1340 (1964),
87. J. J. Llchtenberg", PBC Newsletter, Aug. 20, (1970).
88. B. Ahllng and S. Jensen, Anal, Chem. 42, 1483 (1970). -
89. H. D. Gesser, A. Chow, F. C. Davis, J. F. Uthe and J. Relnke,
Anal. Letters, 4. 883 (1971).
'
.
89a. G. R. Harvey, "Adsorption of Chlorinated Hydrocarbons from Seawater by a Crosslinked Polymer," Unpublished Manuscript, Woods Hole Oceanographic Institution, Woods Hole, November, 1972.
89b. Amberllte XAD-2, Technical Bulletin, Ion Exchange Dept., Rohn and Haas Co., Phlla. Pa. 19105, April, 1970.
90. A. V. Holden, Nature, 228. 1220 (1970).
91. T. T. Schmidt, R. W. Risebrough and F. Gress, Bulletin Envir. Contam. Toxicol.. 6. 235 (1971).
92. E. J, Bonelli, American Laboratory, Feb. 1971.
93. G. D. Velth and G. F. Lee, Water Research, 4^, 265 (1970).
94. J. R. Duffy and N. Wong, J. Agr, Food Chem., 15, 451 (1967).
95. L. J. Stevens, C. W. Collier and D. W. Woodham, Pestle. Monit, J.. 4, 125 (1970).
96. J. E. Fahey, J. W. Butcher and R. T. Murphy, J. Fcon. Entomol., 58, 1026 (196S).
97. W. L. Seal, L. H. Dawsey and G. E. Calvin, Pestic. Monit. J., 1, 22 (1967). -
98. W. L. Trautman, G. Chesters and H. B. Pionke, Pestic. Monit. J., 2^ 93 (1968).
100. C. Golden and E. Sawickl, Presented at the Air Pollution Symposium of the Dallas ACS Meeting, April 16, 1973.
'Tv
HONS 206261
uiwn
DO NOT QUOTE OR CITE
101. Pesticide Analytical Manual, Volume 1, 2nd Ed., U. S.
- department of Health, Education and Welfare, Food
and Drug Administration, 1968. (Revised yearly)
102. D. M. Coulson, J. Gas Chromatog., 3_, 134 (1 965)
103. 0. M. Coulson and L. A. Cavanagh, Anal. Chem,, 32,
1245 (1960)
*`
104. J. E. Lovelock and S. R. Lipsky, J. Am. Chem. Soc.,
82, 431 (1960)
-
105. R. W. Rlsebrough, "Determination of Polychlorobipheny1s
in Environmental Samples," presented at the International
Symposium on Identification and Measurement of
Environmental Pollutants, Ottawa, Canada, June 15, 1971. * s t
106. D. Synder and R. Relnerti Bull. Environ. Contam.
Toxicol. , 385 (1971) 107. 0. L. Stalling, R. C. Tlndle and 0. L. Johnson, J. Ass.
Off. Anal. Chem. 55,, 32 (1972)
108. Pesticide Analytical Manual, Vol. I, Section 251.102, "Separation of Some Polychlorinated Biphenyls from Certain Organochlorlne Pesticides," Food and Drug Administration, U. S. Department of Health, Education
and Welfare, January 1, 1972 109. " H. Evans, Analyst, 87, 569 (1962) 110. J. Armour and J, Burke, FDA Information Bulletin No.
91B (1969) 111. D. W. Anderson, J. J. Hickey and R. W. Rlsebrough,
. Can. Field-Mature, 83, B9-112 (1969) .
112. F. Eno, A.
anr* 1*. nc*'.r,*n. r.-ll. Environ. Contam.
Toxicol. 2, 372 (1967)
HONS 206262
DRAFT
; 00 HOT 0U0TE 0.7 CITE
113.' J. w. Dolan, R. C, Hall and T. H. Todd, 0. Ass. Off.
Anal. Chem. 5, 538 (1972)
114. Monsanto Company, Analytical Chemistry Methods, 69-13,
70-1 and 70-6.
115.
F. 0. Biros, "Pestlclde Identif1catlon at the Residue Level," Advances In Chemistry Series, American Chemical
Society, p. 146 (1971}
'
116. C. J. Thompson; H. J. Coleman, C. C. Ward and H. T.
_ Roll, Anal. Chem. 34, 154 (1962)
__
117. Chemistry Laboratory Guidebook, U. S. Department of
Marketing Service, Laboratory Services Division,
Washington, D. C., August 1971
118. Guide to the Analysis of Pesticide Residues, Vol. I,
U. S. Department of Health, Education and Welfare,
Public Health Service, 1965.
119. Analytical Methods for Pesticide Residues In Foods,
Department of National Health and Welfare, Food and Drug
120.
Directorate, Ottawa, Canada, 1969 Official Methods of Analysis of the Association of
Official Analytical Chemists, 11th Ed., William
" Horwltz, Ed., Washington, D. C., 1970 and subsequent
revisions.
121.
8. Malone and J. A. Burke, J. Ass. Off. Anal. Chem. 5Z_, 490 (19G9)
HONS 206263
B draft
. DO NOT QUOTE OR CITE
122. R. F. Skrentny, R. w. Hemken, and H. H. Oorough, Cull.
Environ, Contain. Toxicol.
409 (1971 )
123. s. W. Bellman and T. L. Barry, J.' Ass. Off. Anal, Chem.
5, 499 (1971)
124. V. Zltko, 0. Hutzlnger and P.M.K. fhol, Environ. Health
Perspect. X* *7 (1972) `
125. T. W. Duke, J, I. Lowe, and A. J. Wilson, Jr., Bull.
Environ. Contain* Toxicol.
171 (1970)
126. J. G. deVos and J. H. Koeman, Toxicol. Appl. Pharmacol.
V7, 65$ (1970)
'
127. V. Zltko, Bull. Environ. Contam. Toxicol. 6_, 464 (1971 )
128. 0. L. Stalling and F. L, Mayer, Jr., Environ, Health
Perspect. 1., 159 (1972) _
.
_____
R. W. Rlsebrough and B. delappe. Environ. Health Perspect.
X, 39 (1972) I' 130. "Baseline'Studies of Heavy Metal, Halogenated Hydrocarbon
and Petroleum Hydrocarbon Pollutants In the Marine
, Environment and Research Recommendations," E. D. Goldberg,
Ed., Deliberations of the International Decade of Ocean
Explorations, Baseline Conference, May 24-26, 1972.
131. Pesticide Analytical Manual, Volume 111, U. S. Department
of Health, Education and Welfare, Food and Drug
Admlnlstratfon, July 1970
132. A. R. Yobs, Pesticides Monitoring Journal X*
(1971)
133. Manual of Analytical Methods, Pesticide Community
Studies Lc,,)''r.itor1es, U. S. Envlronmental Protection *
Agency, Perrlne, Florida, January 197).
I
134. P. Mills, J. Ass. Off. Anal. Chem. 42, 734 (1959).
-VI-
MONS 206264
do r;oT
135. ~T* Kohlma, H. Fukumoto and S. Makisumi, Jap. J. Legal
Med. 23, 415 (1969)
''
136.
137. 138. 139. 140.
"Collection of Autopsy Tissue Sets, CHESS Pollutant
Burden Protocol," Human Studies Laboratory, National
Environmental Research Center, Environmental Protection
Agency, Research Triangle Park, N. C., December 1 1 , 1972.
Tissue Specimen Bank Workshop, Human Studies Laboratory,
National Environmental Research Center, Research
Triangle Park, H. C., February 22-27, 1973.
Nesbitt, I. C. T. and Sarofim, A. F., Polychlorinated Biphenyls-
Environmental Impact, Environmental Research, Vol. 5, No. 3,
pp 273-286, September 1972.
Stanley, C. W., Barney, J. E. II, Helton, M. R. and Yob, A. R.,
Measurement of the Atmospheric Levels of Pesticides, Environ. Scl.
Technol. 5(5), 430-435, 1971.
Miles, J. W., Fetzer, L. E., and Pierce, 6. W., Collection and
Determination of Trace Quantities of Pesticides In Air, Environ.
Scl. Technol.. 4(5), 420, 1970.
.
-S8-
HONS 206265