Document JvaX3npr6o7aymYvEX4K7Qv6
SAFETY ENGINEERING TABLES
TABLE 45-L VENTILATION RATES FOR OPEN-SURFACE TANKS
Process
MmitwMB Ventilation Rato
efm Per Sq Ft Hood Opening
Hood
Hoed'
One Two Three Foot Open Open Open Op*n Side Sides Sides
Minimum Ventilation Rate elm
Per So Ft Tank Area Lateral Exhaust (Note 1)
------
Tank Width Tank Length
W/L 0-0 24
AB
W/L 0 2S-0 49
AB
W/L 0 50-1.0
AB
Plating
Chromium (Chromic Acid
Mist)
75
Arsenic (Arsine) .
85
100 90
125 100
175 150
125 175 150 200 175 225 90 130 110 150 130 170
Hydrogen Cyanide .
75 100 125 175 125 175 150 200 175 225
Cadmium
, 75 100 125 175 125 175 150 200 175 225
Anodizing.....................
75 100 125 175 125 175 150 200 175 225
Metal Cleaning (Pickhng)
Cold Acid....................... Hot Acid.............................
65 75
90 100
100 125
150 175
90 125
130 175
no ISO
150 200
130 175
170 225
Nitric and Sulfuric Acid ... 75 100 125 175 125 175 150 200 175 225
Nitnc and Hydrofluoric Acid 75 100 125 175 125 175 150 200 175 225
Metal Cleaning (Degreasing) See Note 2
Metal Cleaning (Caustic or
Electrolytic)
Not Boiling......................... 65 90 100 150 00 130 110 150 130 170
Boiling .....................
75 100 125 175 125 175 150 200 175 225
Bright Dip (Nitric Add)
75 100 125 175 125 175 150 200 175 225
Stripping
Concentrated Nitric Acid
75 100 125 175 125 175 150 200 175 225
Cone. Nitnc and Sulfuric
Acid................................. 75 100 125 175 125 175 150 200 175 225
Salt Baths (Molten Salt) ... 50 75 75 125 60 90 75 100 90 no
Salt Solution (Parkenze, Bondenze, etc.)
Not Boiling..................... 90 90 100 150 90 130 no 150 130 170
Boiling................................. 75 100 125 175 125 175 150 200 175 225
Hot Water (if vent, desired)
Not Boiling
. ...
Boiling
50 75 75 125 60 90 75 100 90 no
75 100 125 175 125 175 150 200 175 225
ASHRAB Guide and Data Book. 1962, Chapter 21 Used bp permission
Note 1 Column A refers to tank with hood along one side or two parallel sides when one hood is against a wall or a baffle running length of tank and as high as tank is wide, also to tanks with exhaust manifold along center line with W/Z becoming tank width in W/L Ratio* Column B refers to free standing tank with hood along one side or two parallel sides
Note 2 Complete control of the vapors and mist from degreasing operations requires the same ventilation rates as recommended for pickling However, the solvents employed in degreasing operations are relatively volatile, and the solvent loss caused by evaporation increases rapidly as the exhaust rate at the tank increases For this reason, perfect control is usually sacrificed in favor of lower solvent evaporation rates Where solvent loss does not present an important cost or operating problem, the exhaust rates given for pickling should be adhered to, but where solvent loss must be kept at a minimum, an exhaust rate of 50 cfm per sq ft of tank area is commonly employed. Where this rate is used, control
will be adequate only if the tank is located in an area free of drafts and if the deceasing
operations are earned out in accordance with a rigid schedule
45-30