Document Jv3O763wkKpr87gqNjKM4Mbz6
\* l^oosnnto (lo^o)
TECHNICAL DATA SHEET MCS-1S65 AND MCS-1666
TRANSFORMER FLUID S
No. ic-/r f - 4'7 fPATE :. m / r<0
Fluids for use in liquid-filled transformers should
have high dielectric strength, wide operating temperature
range, good heat transfer properties, chemical stability
and be fire resistant. MCS-1B65 and MCS-1866 were developed
to provide such characteristics, and are suggested for
evaluation as dielectric fluids for transformers.
j
,
MCS-1865 and MCS-1866 do not contain polychlorinated biphenyl (PCB) nor silicone fluids. Both MCS-1865 and MCS-1866 are synthetic hydrocarbons combined with trichloro benzene to give the desired viscosity level. These fluids , have a considerable degree of fire resistance, but are not equivalent to askarels in this general characteristic.
Technical data on typical laboratory samples are
given below. Additional studies are underway and the data
will be supplied later. Samples are available for preliminary
___ _____ _ evaluation.---------- ---------- --------- ------------ ------------ ------------- --------------- ------
$TANDAR.P DISCLAIMED tLAwlt. <?*<>) *FlRE ASSISTANCE. dlSOLfllMd A- (60XE0)
.
MdNSfthtrO (LObo)
tAlO
LINE
....................
TOWOLDMON0043823 WATER_PCB-00028292
nts-iooa
ELECTRICAL PROPERTIES *
Dielectric strength (ASTM D877) 25C, 0.1 inch gap
>50 KV ,
Impulse Strength
Power Factor, 100"c, 60 Hz (ASTM D924)
>120, <160 KV
0.11%
Dielectric Constant, 100C, 60 Hz (ASTM D924)
2.56
Gassing Tendency (ASTM D2298)
9.5 ml/min
mp- XODO
42.1 KV
0.01%
2.74 41.2, 31.7 ml/
min
FIRE RELATED PROPERTIES * Flash Point (ASTM D92) Fire Point (ASTM D92) Auto Ignition Temp., (ASTM D2155) Oxygen Index
315F. (157"C) None to b.p. 750'>F(399"C)
18.3
255F(124 0 None to b. 800CF(427
17.1
PHYSICAL PROPERTIES *
.
Specific Gravity @ -30C -15"c 0"C 25*C 50" C 100"C 150"C
1.027 1.016 1.005 0.987 0.970 0.933 0.895
Coefficient of Exp., ml/ml,C
0.000750
Viscosity, @ -40c
-30"C -15C
0C 25C 50"C
10;C 150"c
cs.
' O20b9b<' 02 -
19,620 5,119 1,040 306 69.5 24.4 6.44 2.88
~
i.oe8 1.076 1.065 1.045 1.026 0.988 0.948
*
0.000761
-
1830 426 140 37 14.7 4.50 2.18
*Thls data is based upon samples tested In the laboratory and is not
guatanteed for all samples.
................
.............. _ . .
_'
I
' TOWOLDMON0043824 WATER_PCB-00028293
Pour Point (AETM D97)
Temperature C at which Vapor Pressure ist
1 Torr 10 Torr 100 Torr 760 Torr
`
Specific Heat, @ 25F 50F 100F 150 F
BTU/lb.
Thermal Conductivity BTU/ft., hr. @ 25F 50F 100F 150F
MCS-ie65 -SO'F^S'C)
MCS-1P66 ,-50F
58 49 104 96 169 161 248 240
0.412 0.430 0.466 0.501
0.390 0.406 0.43B 0.470
0.0785 0.0771 0.0744 0.0716
0.0744 0.0729 0.0702 0.0675
MATERIALS COMPATIBILITY
'
L
Extensive compatibility testing has not been completed.
However, it is expected that those materials which are used with
asharel transformer fluids will also be compatible with MCS-1865
and MCS-1866. It is recommended that compatibility tests be conducted
between the fluids and samples of the specific material to be used
under conditions simulative of actual use. A good procedure for such
testing is ASTM 3255, Method for Investigating the Compatibility of
Transformer Insulation and Construction Materials in Askarels.
HANDLING PRECAUTIONS
0205570
7
statement of handling precautions is currently being prepared by the Medical Department and will be added to this bulletin before it is printed).
Monsanto (Jefio)
TOWOLDMON0043825 WATER_PCB-00028294