\* l^oosnnto (lo^o) TECHNICAL DATA SHEET MCS-1S65 AND MCS-1666 TRANSFORMER FLUID S No. ic-/r f - 4'7 fPATE :. m / r<0 Fluids for use in liquid-filled transformers should have high dielectric strength, wide operating temperature range, good heat transfer properties, chemical stability and be fire resistant. MCS-1B65 and MCS-1866 were developed to provide such characteristics, and are suggested for evaluation as dielectric fluids for transformers. j , MCS-1865 and MCS-1866 do not contain polychlorinated biphenyl (PCB) nor silicone fluids. Both MCS-1865 and MCS-1866 are synthetic hydrocarbons combined with trichloro benzene to give the desired viscosity level. These fluids , have a considerable degree of fire resistance, but are not equivalent to askarels in this general characteristic. Technical data on typical laboratory samples are given below. Additional studies are underway and the data will be supplied later. Samples are available for preliminary ___ _____ _ evaluation.---------- ---------- --------- ------------ ------------ ------------- --------------- ------ $TANDAR.P DISCLAIMED tLAwlt. <?*<>) *FlRE ASSISTANCE. dlSOLfllMd A- (60XE0) . MdNSfthtrO (LObo) tAlO LINE .................... TOWOLDMON0043823 WATER_PCB-00028292 nts-iooa ELECTRICAL PROPERTIES * Dielectric strength (ASTM D877) 25C, 0.1 inch gap >50 KV , Impulse Strength Power Factor, 100"c, 60 Hz (ASTM D924) >120, <160 KV 0.11% Dielectric Constant, 100C, 60 Hz (ASTM D924) 2.56 Gassing Tendency (ASTM D2298) 9.5 ml/min mp- XODO 42.1 KV 0.01% 2.74 41.2, 31.7 ml/ min FIRE RELATED PROPERTIES * Flash Point (ASTM D92) Fire Point (ASTM D92) Auto Ignition Temp., (ASTM D2155) Oxygen Index 315F. (157"C) None to b.p. 750'>F(399"C) 18.3 255F(124 0 None to b. 800CF(427 17.1 PHYSICAL PROPERTIES * . Specific Gravity @ -30C -15"c 0"C 25*C 50" C 100"C 150"C 1.027 1.016 1.005 0.987 0.970 0.933 0.895 Coefficient of Exp., ml/ml,C 0.000750 Viscosity, @ -40c -30"C -15C 0C 25C 50"C 10;C 150"c cs. ' O20b9b<' 02 - 19,620 5,119 1,040 306 69.5 24.4 6.44 2.88 ~ i.oe8 1.076 1.065 1.045 1.026 0.988 0.948 * 0.000761 - 1830 426 140 37 14.7 4.50 2.18 *Thls data is based upon samples tested In the laboratory and is not guatanteed for all samples. ................ .............. _ . . _' I ' TOWOLDMON0043824 WATER_PCB-00028293 Pour Point (AETM D97) Temperature C at which Vapor Pressure ist 1 Torr 10 Torr 100 Torr 760 Torr ` Specific Heat, @ 25F 50F 100F 150 F BTU/lb. Thermal Conductivity BTU/ft., hr. @ 25F 50F 100F 150F MCS-ie65 -SO'F^S'C) MCS-1P66 ,-50F 58 49 104 96 169 161 248 240 0.412 0.430 0.466 0.501 0.390 0.406 0.43B 0.470 0.0785 0.0771 0.0744 0.0716 0.0744 0.0729 0.0702 0.0675 MATERIALS COMPATIBILITY ' L Extensive compatibility testing has not been completed. However, it is expected that those materials which are used with asharel transformer fluids will also be compatible with MCS-1865 and MCS-1866. It is recommended that compatibility tests be conducted between the fluids and samples of the specific material to be used under conditions simulative of actual use. A good procedure for such testing is ASTM 3255, Method for Investigating the Compatibility of Transformer Insulation and Construction Materials in Askarels. HANDLING PRECAUTIONS 0205570 7 statement of handling precautions is currently being prepared by the Medical Department and will be added to this bulletin before it is printed). Monsanto (Jefio) TOWOLDMON0043825 WATER_PCB-00028294