Document Jrrmn8337gg3rd1ObKLkevbpa
-; ,
lO d o l.n i,
boiler-burner models and boilers
Arcoliner oil-fired heating unit
AMERicAN-^tandard
15264
|
The Arcoliner is a masterpiece of precision engineering that provides magical carefree hot water comfort for small and medium sized homes. All components of the Arcoliner--the boiler sections, burner, primary controls, combustion chamber --have been designed and completely integrated into an oil-fired unit to provide the finest home heating comfort.
Made in four compact modeis for either steam or water, the Arcoliner is perfect for installation in first-floor utility rooms as well as basements. Sturdy, long-lasting, corrosion resistant cast iron construction of the boiler sections assures a lifetime of clean, efficient hot water or steam heat for any style of home. To assure positive, dependable performance, every Arcoliner assembly is factory tested at two-and-one-half times normal operating pressure before shipment. For ease of installation, boiler sections are completely assembled at the factory. The Arcoliner, with its superior features, makes it the ideal heating unit for either new or modernized homes.
factory-installed steel combustion chamber means additional American-Standard quality furnished with Arcoliner boiler-burner units. Special factory-molded refractory combus tion chamber that saves the labor and expense of a hand-built unit available for boiler only.
sling-mounted Model DH Arcoflame Oil Burner is an integral part of the Arcoliner boiler-burner unit. The highly efficient burner is installed simply by sliding the pressure plate over the air tube and hooking the burner on the sling mount. All units shown are equipped with the fuel-saving Model DH Arcoflame Oil Burner.
continuous hot water for household use can be provided automatically both winter and summer when the Arcoliner is equipped with a built-in tank or tankless type hot water heater. Arcoliner units not equipped with a water heater have a heater opening in the back section which takes a heater opening cover plate. A heater may be installed quickly and easily at any time simply by removing the cover plate and inserting the heater coil. No separate storage tank is required when a tankless type heater is installed.
wet base construction is an important design feature of the Arcoliner. Waterways extend below the combustion chamber providing added effective heating surface and in creasing boiler efficiency. This construction also accelerates water circulation, provides lower return tappings, helps keep floor cool, which is important for first-floor installations.
Arcoliner Oil Boilers by American-Standard have ratings approved by the Institute of Boiler and Radiator Manu facturers. They are designed and built to comply with the requirements of the American Society of Mechanical Engineers' Code and American-Standard is authorized to apply the appropriate Code symbols. The Arcoflame Oil Burners are listed by the Underwriters' Laboratories, Inc., for No. 1 and No. 2 commercial fuel oil, comply with Commercial Standard CS-75 and are approved by the New York City Board of Standards and Appeals, by the State Fire Marshal of the Commonwealth of Massachusetts and by the Department of State Police, State of Connecticut.
15265
1- jacket extension - matches jacket; has re movable front pane! for easy access to burner and Ouiiifuis. uesigiieu iu permit ample nun uf an fur combustion. Optional for all models.
2-- boiler sections - made of durable cast iron, the one metal that has proven best over the years for use in heating equipment. Sections are factory assembled and shipped ready to install. Joints between sections are machine ground to assure a tight, close fit.
s-two-pass (lues-offer maximum heat-absorbing surface. Multi-finned water tube surfaces extract extra heat units from hot combustion gases.
4--water content - small amount of water to heat in waterways permits more rapid heat transfer and quicker pickup.
s-water heater - provides year 'round domestic hot water automatically. Built-in tank or tankless type. Special tankless type, illustrated, makes use of extruded integral finned tube surfaces to gain maximum heat transfer in coil.
6- jacket-sturdy steel; smartly styled in attrac tive gray finish. All parts are die cut and formed for easy assembly. Interior surfaces are finished with corrosion-resistant, high-temperature alu minum paint.
7- doors-construction of heavy cast iron, with cast iron heat-protecting baffle linings to prevent warping and heat loss. Precision fitted to elimi nate infiltration of air. Provide ready access for cleaning of boiler sections, easy maintenance.
8- observation port -- permits observation of oil flame without disturbing combustion or flame characteristics. Convenient cover is designed to conceal port when not in use.
-Model DH Arcoflame oil burner-special slingmount model designed for this boiler. Boiler and burner operate as a unit for top efficiency. Other adaptable burners may be used.
fo-combustion chamber-Heat Lib-O-Rator com bustion chamber, made of high-temperature steel or refractory brick, is especially adapted to size of boiler selected.
it-wet base construction -- for extra heating surface and increased efficiency. Waterways ex tending underneath combustion chamber keep floor cooler; ideal for first-floor or basementless installations.
n-combustion space-scientifically proportion ed with correct area of effective heating surface to assure maximum heat from fuel burned. Crown sheet baffle is furnished on three smaller boiler sizes.
is--insulation - heavy Fiberglas insulation be neath the flush metal jacket effectively prevents excessive heat loss, saves fuel and helps keep jacket cool.
Arcoliner ratings
models for steam or water
boiier-bumer unit number
steam
water
S-0-153-B-T S-O-154-B-T S-0-155-B-T S-0-156-B-T
W-0-153-B-T W-0-154-B-T W-O-155-B-T W-0-156-B-T
oil boiler number
steam
water
S-0-153-T S-0-154-T S-0-155-T S-0-156-T
W-0-153-T W-0-154-T W-0-155-T W-0-156-T
net l = B = R ratine*
water
Btu/hr sq ft Btu/hr
72.800
303
72,800
99,000
413
99,000
123,0Gu 513 123.000
141,000 588 141.000
gross I =B = R output Btu/hr
97,000 132.000 164.000 188.000
l=B=R burner capacity
fPb
1.00 1.35 1.60 1.80
chimney
sue inches
height feet
8x8 20 8x8 20 8x8 25 8x8 25
When furnished less Aneoflame Oil Burner, it is recommended that
boiler be fired at specific firing rate and with an oil burner that complies with Commercial Standard CS-75. Oil heating unit number includes Arcoflame Oil Burner (suffix B). Suffix T indicates that unit is designed for, but not equipped with, a built-in tank or tankless type water heater.
The ratings for these boilers represent the net loads that may be connected to the boilers. Allowances have been made for normal piping and pick-up loads. NOTE: Nozzle sizes, gph, furnished with Arcoliner boiler-burner units are as follows: No. 153, 0.90-70" H; No. 154, 1.25-60" H; No. 155, 1.50-60" S; No. 156. 1.65-60" S.
Iron! view
front view - jacket extension
side view - jacket extension
boiler number
dimensions Inches A8 c
S or W-0-153-T* S or W-0-154-T* S or W-0-155-T* S or W-0-156-T
13 18 23 28
A Add Wa~ to length for smoke collar
_ 12% -- 17% 13 22% 13 27%
equipped with crown sheet baffle
back view
DA flush jacket 20% 25% 30% 35%
cutaway thru boiler section
EA jacket extension
40% 45% 50% 55%
number and size tappings
inches
flow return
1-3 1-3 1-3 1-3 2-3 1-3 2-3 1-3
built-in water heaters
type of boiler
recommended water heater
capacity-gallons ISO9 boiler water temp.
system size of water conneetions-inches
steam or water
589 596 587
3 per min 3% per min 85*
%
% i
Tank type water heaters rated on basis of raising temperature of domestic hot water 100 F. in 3 hours-- tankless type rated in gallons per minute, dependent upon oil firing rate.
American-Standard Arcoliner Oil Boilers are another development in hydronics - the science of heating and cooling with water.
type
tankless (flange) tankless (flange)
tank (flange)
AMERICAN-cStandard PLUMBING and heating division
AMERICAN RADIATOR & STANDARD SANITARY CORPORATION 40 WEST 40TH STREET * NEW YORK 18, NEW YORK Lit ho
U5
15267