Document JrpYygm4ModrbLDO7RgMmp67v
H&P March 72
Pollution/Houghton EJ
Pollution and hydraulic fluids: what you should know
Here are six terms used in environmental laws and regulations to describe the condition of plant effluent, which usually contains hydraulic fluid^ It is cheaper to keep hydraulic fluids out of plant effluent through improved maintenance.
William Millett
There's a special nomenclature that hydraulic fluid users need to know if they are to understand what they're up against with
4/nA pollution laws^regulations. These terms include: biodegradability, BOD, COD, PPM, pH and TLm. You may be familiar with two or three of these, or maybe all. They've had a great deal of publicity.
0065398
TOWOLDMON0055903
H&P
March 72
Pollution/Houghton EJ
-2-
Biodegradability is the most commonly used/ and misunderstood term. An organic compound capable of being oxidized by micro organisms is said to be biodegradable. The eventual end products of biodegradation are oxygen and carbon dioxide. But the word, "biodegradable" doesn't tell you anything about time or degree. It doesn't say how fast or slow. And some compounds or mixtures are only partly biodegradable.
Hydraulic fluids are no longer "just oil". With the advent of fire-resistant hydraulic fluids and multiple oil additives^ hydraulic fluids now are often chemicals or mixtures of chemicals and petroleum oil. Some are partially biodegradable^ others hardly at all. Some fast, some very slow. That's why biodegradation of non-petroleum type hydraulic fluids should be specifically discussed in such terms as - does it occur? and,
takes us &Lto the next term.
, or the amount of oxygen consumed by microorganisms that act to oxidize a waste. The process can be called biodegradation. It is an oxidizing process with the microorganisms doing the work^but requiring available oxygen to function.
BOD of a waste water is measured by treating (innoculating) the water with known microorganisms and observing the quantity
0065399
1I
TOWOLDMONOQ55904
H&P March 72
Pollution/Houghton EJ -3-
oxygen consumed over a specified time at a specified temperature Typical tests are at 20 C (68 F) over a 5-day period. This test is specified in the American Water Works Association book "Standard Methods for the Examination of Water and Waste Water." Results of such tests are the commonly used standards of reference when BOD is discussed.
Closely related to BOD is COD, Chemical Oxygen Demand. They
both have the "oxygen demand" in common. But in the case of COD
it is a chemical rather than a biological process that is involved.
COD refers to the oxygen required for oxidation of oxidizable
m. material in a waste water by chemical ^eans. Although COD is
not related to biodegradability, it does provide a point of
with
reference Jsa respect to the oxidizable matter in a waste water, A
To measure COD, potassium dichromate, an oxidizing agent, is normally used. The quantity of oxygen required to*completely oxidize all oxidizable matter is measured.
<Coupling BOD and COD Values
An examination of BOD and COD values can help show how much oxidizable matter is present in a waste stream and the degree to which it is biodegradable under prescribed conditions. A low BOD coupled with a low COD indicates relatively low levels
C of oxidizable organiy^ coumpounds. A low BOD coupled with a
TOWOLDMON0055905
H&P
March 72 Pollution/Houghton EJ -4-
high CCD indicates high levels of organic compounds that are not readily biodegradable. High BOD and COD values indicate relatively high levels of contamination and a high degree of biodegradability.
Note that high BOD values go had in hand with ease of biodegradability. Conversely, we cannot expect low BOD values and biodegradability from the same system. Thus, the cry for biodegradable products with negligible BOD is seen to be contrary to the laws of nature. There's more kbout how this applies to hydraulic fluids later on.
Another pollution term is PPM, which stands for parts per B
million. One part per million is the same as one milligram
p
per liter. Here's a simple way to visualize that. If you put
a one-ounce shot glass of vermouth in an 8000-gallon tankcar
of your favorite gin, you'd have a L-PPM martini. So you can
see that 1 PPM is pretty small.
It's difficult to measure with precision in many tests, yet pollution control standards call for exact PPM measures. Con centrations of contaminants in waste water are normally expressed as parts per million as are values for BOD and COD. Levels of some chemicals as low as 1 PPM can be quite a problem in a small stream or in drinking water.
0065401
H&P
March 72 Pollution/Houghton EJ -5-
The terra H is a familiar one. It's a measure of acidity or alkalinity of water solutions, and ranges from 0 to 14. Seven is neutral, above seven is basic or alkaline, below seven is acid. Each number more or less than seven represents increasingly more powerful acidity or alkalinity. That's why man states limit the pH range of waste water.
< Pish Kill Test
' Toxicity is also important in discussing hydraulic fluids because these fluids often end up in streams or other public waterways. (And because humans handle them, although that's a different topic.) There are many ways to measure toxicity. The measure we use is based on the possible hazard to vegetative and marine life.if hydraulic fluids in a plant effluent are
nJ eventually released into a stream.
A standard "fish kill test", described in the reference
book mentioned earlier, is used as the measurement. Bluegill
fish swim in various PPM-solutions of test waste under standard
conditions. The number of dead fish is counted and expressed
in terms of the concentration (PPM) that permit 50% of the fish
9 to live 96 hours. This would be a TLm96. A TLny^6 of 100 ppm,
for example, means that at a concentration of 100 ppm, 50% of the
bluegill fish survive at least 96 hours.
'A1; $* 7"Z/>i
jj<m. finOx- rfJut
r
0065,0/1
H&P March 72
Pollution/Houghton EJ -6-
<How to Treat Petroleum Oils
Now, how does all this apply to hydraulic fluids? First, let's consider petroleum oiIStuiaria. S4aan^ essentially
A non-biodegradable so it has no BOD. It's insoluble, so can't be tested for TLm in standard procedures. pH isn't a problem. Yet it is a pollutant because it floates to form a slick over water surfaces, blocking oxygen. Also, small amounts of oil remain dissolved or suspended in the water. This can be measured. The oil content can be removed by extraction with hexane and represents a portion of the "hexane extractables". Typical state legislation limits hexane extractables to between 15 and 30 PPM into a stream, or 100 PPM maximum into a sewage treatment plant.
Oil is normally separated from plant effluent by skimming or a similar process, then reprocessed or burned. Thus the major considerations with oil are the volume that is dispersed with effluent, collecting and separating it, and reusing or disposing of it.
Leakage of petroleum oil fluids can be controlled at the source with adequare attention to maintenance procedures, including the use of efficient sealing materials. Thus, control of petroleum oil hydraulic fluid pollution is technically feasible now, and increasingly implemented.
006^`>03
TOWOLDMON0055908
H&P
March ;72
Pollution/Houghton EJ -7-
-cEmulsion-Type Fluids
Emulsion--type fire-resistnat fluids must be split and separated. Treatment with acid or certain salts will do this. The oil layer is handled like petroleum oil. The water layer
should be neutralized to a pH of seven. Then, it should be tested for BOD, COD, and toxicity.
Typical regulations require control of effluent pH into a stream to a range of 6 to 10 and suspended solids to a maximum level of 45 ppm. Also, effluent BOD values are often limited to a specified maximum. Effluent going into a sewer has broader latitude. But the basic point is to test the water
5
layer, ^ind out what's in it, and match this against regulations. If it doesn't meet regulations, dilute it or provide proper treatment.
~0Water-Glycols
Water-glycols are completely water soluble, unlike oils,, so they present a didferent set of problems. Here, BOD, COD, pH, TLm and other measures can be made. Water-glycols have BOD values ranging from 50,000 to 500,000 PPM. Consequently, when concentrations are high, they must be diluted, reduced, or degraded before they are allowed to enter a stream.
0065'!'
TOWOLDMONOQ55909
naicn i& roixuxion/Hougnxon H&h* hj
-8-
The best way to reduce BOD stemming from hydraulic flu ids
in plant effluent is to change and tighten sealing to prevent
the leakage. This saves money, too, because less fluid is
used. Savings can pay for the extra maintenance. If your
plant has tertiary treatment facilities, water-glycols are
readily treatable. Water-glycols usually have highly suitable
TLm's. They run from 500 PPM up, which is considered relatively
safe.
'
-C Phosphate Esters
Phosphate esters are insoluble in water and heavier than
water. So they cam be settled out in collecting lagoons and
reprocessed. Because of their insolubility, typical industrial
aryl phosphates biodegrade slowly, but there is a very real
oxygen demand. A typical BOD value is somewhere around 35,000
PPM oxygen, which shows significant biodegradation.
<-
Tbm values of phosphate esters are not easily determined
S&OStf' the fluid is essentially insoluble in water. Depending
on the procedure and the particular ester, TLm96 values range
from 60 to 500 PPM, which represents a higher level of toxicity
than water-glycols, but well within acceptable ranges for commonly
used industrial products.
0065405
Preferably, phosphate ester contamination should also be eliminated at the source through proper maintenance practice. Alternatively, they should be removed by settling. If this is
TOWOLDMONOQ55910
H&P March 72
Pollution/Houghton EJ -9-
done, the small residual quantities that remain will usually fall within the limits set by most regulating agencies. There's no evidence that phosphate esters persist in the environment, or build up in the food chain, so they are not an environmental hazard as employed,
--^Petroleum Fractions and Phosphate Esters
Some hydraulic fluids are combinations of selected petroleum fractions and phosphate esters. In effluent traps or settling
fch4' ponds, they will rise to /? Surface where they can be removed and treated as oil. BOD and fish toxicity considerations that apply to oil and phosphate ester apply to these fluids.
--^Chlorinated Hydrocarbons
Some hydraulic fluids contain chlorinated aromatic hydrocarbons.
006&406
TOWOLDMONOQ55911
H&P March 72
Pollution/Houghton EJ
-10-
How to Reduce Hydraulic Fluid Pollution Immediately
A plant can take steps immediately to minimize hydraulic
fluid pollution:
'
' . locate leaky seals and replace them.
. tighten the system to minimize all sources of leakage. . install collectors fox drains to isolate any fluid that
leaks out of the system. In most plants, this is enough to solve a problem, if one exists. ^j^We're convinced the eventual answer to hydraulic fluid pollution
is to keep fluids in the system, where they belong. In the mealime, leaking fluid should be contained, and kept out of general plant effluent. If you can keep it separated, it can be reconstituted, treated separately, or released slowly into effluent to meet requirements.
0065407
I
TOWOLDMONOQ55912
H&P March 72
Pollution/Houghton
-//-
Pollution Glossary for Fluid Power Designers
(API Separator A facility for separation of oil from waste water by gravity differential and equipped for recovering the separated oil and removing sludge. Developed by the Committee on ' Disposal of Refinery Wastes of the American Petroleum Institute
CBiochemical Oxygen Demand (BOD):
The amount of oxygen utilized by
organisms in the biochemical oxi
dation of
matter in waste
water in a specified time and at
a specified temperature. BOD is
determined entirely by the avail
ability of a wastewater component
as a biological food and by the
amount of oxygen utilized by the
microorganisms during oxidation.
Hence it is not related to
chemical oxygen demand.
. .
^Biodegradable: Capable of being oxidized by mioroorganisms
0065408
TOWOLDMONOQ55913
H&P MAR 72 Pollution/Houghton
IX {*-
(^Biodegradation: Metabolic utiliza tion by microorganisms of a comp onent in a wastewater stream,
^Biodegradation System: A waste
treatment facility or system in
which undesirable components of
the flow are removed by biological
means, such as living organisms
in an activated sludge unit.
(^Biological Oxygen Demand
^
See Biochemical Oxygen Demand.
rCheraicai Oxygen Demand (COD):
A measure of the oxygen equivalent
required for oxidation by chemical C
means of organy^ and oxidizable
inorganic matter in wastewater, A
corrected for the influence of
chlorides present.
^ Clarification: A process in which suspended material is removed from a wastewater. This may be achieved by sedimentation, with or without chemicals, or filtration.
,
(
j
s /
-
TOWOLDMONOQ55914
H&P Mar 72
Pollution/Houghton
,
Ci>issolved Solids ^Chemical substances '' C
either organi^ or inorganic that
are dissolved in a waste stream
and which constitute the residue
when a sample is evaporated to
dryness.
Ecological Balance: Status of the
mutual relations amoung organisms
and between them and their environ
ment,
.
f Emulsion: A hetrogeneous system consisting of one liquid dispersed i n the form of fine droplets in another liquid in which it is insoluble. Unaided separation of the two liquids occurs very slowly,
"
.
4 Gravity Separation: Separation of
suspended material from a waste
water flow by settling under
quiescent conditions. This
procedure is based on the mech
anism of gravity differential,
the gravity difference between the
suspended material and the water carrier,
oofe***10
`V,
TOWOLDMONOQ55915
H&P
Mar 72
Pollution/Houghton
IV
.
C^Oxidati^nT)A chemical reaction
or process in which oxygen usually
is added to a substance. For
example, sodium nitrite (NaN02)
is oxidized to sodium nitrate
(NaN03) or phenol
is
oxidized to carbon dioxide (CO^)
and water (H^O).
C Parts Per Million (^ppm)l^Che unit
commonly used to designate the
concentration of a contaminant or
a
substance in^waste water in terms
of weight, for example, one pound
per million pounds, etc. Ppm is
synonomous with milligrams' per
liter (mg/1) which is replacing
the terra ppm,
( Sedimentation: The process of subsidance and deposition of suspended a matter from wastewater by gravity. A
(^Segregation: The act of separating and keeping apart one waste stream from another. ,
0065411 A
TOWOLDMONOQ55916
H&P Mar 72 Pollution/Houghton
-U-
isr
^Settleable Solids :^That portion
of the suspended solids in a waste
stream capable of settling in unit
time*
^Suspended Solids:^ Solid particles
or insoluble liquid droplets
$ suspended m waste flow.
A'
Also,
the quantity of insoluble material
obtained by filtering a quantity
of waste through a filter.
JM,
c
. "
sl b.
0065412
i
TOWOLDMONOQ55917