Document Jrkaa21ObyMDO0wLb54ay5R82

DownloadRandom document
AR226-1999 TABLE 1. Compariso)1 of Tenax Tubie (T.T.5 and Aquecus-Imp!nger (A.,1.) C-8 in Ailr Detenninaticins . Sampling Location No. of Sample Sets Collected* Avg. T.T. C-8 Determination (mpb) B-163, Float. Tank, No. 2 7 Clean Room** B-163, No. 2 T. D. Dryer, No. 2 10 Clean Room** B-163, No. I Clean Room** 4 B-163, No.t Coagulator, 13 2nd Floor B-163. Flake Hopper 6 B-162, Fine Powder Dryer Room 6 B-163, Tray Conveyor Walkway 6 B-163, Oyen Control Room 6 B-163, Trayout 4 B-163, No. 1 Coagulator, 7 1st Floor B-163, No. 1 Blender 12 2.50 2.14 4.31 0.46 0.53 0.27 <0.06 <0.06 <0.06 0.15 0.12 Avfl. A.I. C-8 Determination (mpb) Ratio T.T. Avg./ A.I."Avg. 0.41 6.1 0.54 4.0 1.83 2.4 0.35 1.3 0.43 0.25 0.06 0.03 0.05 0.20 1.2 1.1 ~1.0 1.0 ~1.0 0.8 0.19 0.6 * Each sample set consists of one Tenax tube result and one aqueous-impinger result. Both samples in each set were collected side by side so their results could be directly compared. ** According to the paired-t test (p :s 0.05), a statistically significant increase in C-8 levels using the Tenax tube technique is observed only for those samples collected in the FEP Clean Rooms. The two techniques yielded equivalent C-8 results for all other sampling locations. JGL:sdc 1988B EID079286