Document JrVgw2nZGyn5ZxGaJnjzxJzoe

TOWOLDMON0039548 WATER_PCB-00024017 for air compressor systems... safer operation at less expense TOWOLDMON0039549 WATER PCB-00024018 PYDRAUL AC sai/es maintenance costs A serious problem facing air compressor operators has been the high maintenance costs of cleaning valve deposits caused by petroleum lubricants. Further difficulties are high exhaust temperatures resulting from mal-function of valves and high cylinder temperatures that cause varnish deposits on cylinder rings and walls. With veao? of experience in the synthetic lubricant held behind thorn, Monsanto researchers sought the answer to this plaguing problem. After testing many types of fluids, they found a fire-resistant lubricant that proved to be ideally suited for air compressors. They called it Pydraul AC. Pydraul AC reduces exhaust valve and air compressor piping deposits to a minimum in all types of air compressors. Fewer carbon deposits on exhaust valves and in interstage equipment means a substantial savings for the operator who must pay the cost of cleaning as well as the cost of down time on the equipment. Lower maintenance cost alone usually justifies the use of Pydraul AC in air compressors. removes explosion threat There are nearly as many theories as there are men voicing opinions as to why fires and explosions happen in air compressor systems, but one point is generally agreed upon: petroleum oil lubricants are directly involved. Apparently, oil mist and films gradually accumulate throughout the air system. These break down into combustible gases and carbonaceous residues that can ignite to produce an explosion or receiver fire, or both. Pydraul AC has proven its ability to reduce these hazardous residues to an absolute minimum or eliminate them completely! By minimizing residues, Pydraul AC effectively reduces the threat of compressor fires and explosions. And Pydraul AC is fire-resistant. It provides safe operation, protecting not only the equipment, but the lives of workers as well. z 0621C83 TOWOLDMON0039550 WATER_PCB-00024019 COMPRESSOR EXPLOSIONS... . UNPREDICTABLE The history of compressor explosions shows an unfortunate fact--they are entirely unpredictable. They can occur in small compressors operating at 50 psig. and in large installations operating at very high pressures. There is no pattern, no way to predict the safety of a particular compressor operation. Such explosions and fires are considered infrequent by some people. In fact, an air compressor operator might go along for years without an accident. However, when they happen, these explosions and fires can blow entire compressor systems apart and even rip yard piping out of the ground. The cost for equipment loss and down time from these accidents can be staggering. Fire-resistant Pydruul AC essentially eliminates the basic cause for most fires and explosions by minimizing the carbon dep>osits. Its superior oxidation 0621084 TOWOLDMON0039551 WATER_PCB-00024020 P Y D R A U L AG GIVES YOU SAFETY AND EFFICIENCY. TOO Comprossor operators have kept n close watch on the development of Pydroul AC. seeking (he answer to one paramount question: "How well does Pydroul AC lubricate? " With lubricating qualities proven equivalent io those of (lie highest grade petroleum oil. Pydraul AC has demonstrated its operating efficiency in air compressors of almost every conceivable type. The statement of a lubricating engineer quoted below typifies its reception as a lubricant. The compressor was a Cooper-Besscmer JM-5 located in a large Midwestern plant. "Lubricating properties of Pydroul AC have been very satisfactory. Wear measurements on Molypak rings taken approximately five months later indicate 0.003" wear. This is normal and considered very good. No corrosion of cylinder liners, valves and piping has been experienced, and service is very satisfactory .........Lubricating Engineer 0621085 TOWOLDMON0039552 WATER_PCB-00024021 COMPARISON OF INDUSTRIAL AIR COMPRESSOR VALVE DEPOSITS FROM TWO LUBRICANTS Compressor Data: 142 CFM. 6" LP Bore. B" HP Bore. 5" Stroke. 870 RPM. 100 PSI Air. f 500 HOURS ON PREMIUM PETROLEUM OIL 500 HOURS ON PVDRAUL AC 0621086 TOWOLDMON0039553 WATER_PCB-00024022 PYDRAUL AO reduces CARBON DEPOSITS deposits formed during the 500 hour operation on two lubricants: one, a premium grade petroleum oil. and the other. Pydraul AC. Deposits formed from the 500-hour operation on petroleum oil were removed before the valve began operating on Pydraul AC so the valve was perfectly clean before each operation. A glance at the photo on the left shows that a considerable amount of carbon formed in the normal 500-hour take-down period for petroleum oil. The photo on the right shows the great impnnement when the valve ofxniled 500 hours on Pydraul AC. In this particular case, the compressor operator expects to get 7.500 to 10.000 hours of service from Pydraul AC without shutting down a 1.5- to 20 fold increase of operating time without a shut-down. That's a substantial saving of time and money due to Pydraul AC. 0621087 -7 TOWOLDMON0039554 WATER_PCB-00024023 PYDRAUL AC is JRRENTL Y JSE AS A LUBRICANT IN AIR CGMPRESSORS MAul lsY THESE MANUFACTURERS. . . American Messer Corporation Bury Compressor Company Chicago Pneumatic Tool Company Clark Brothers Company Cooper-Bessemer Corporation Oe Laval Steam Turbine Company Fuller Company Gardner-Denver Company Ingersoll-Rand Company Joy Manufacturing Company Norwalk Company, Inc. Schramm, Inc. Worthington Corporation Pydraul AC has been used as an air compressor lubricant for periods up to five years and is now successfully lubricating hundreds of compressors of all types and sizes produced by all of the major compressor manufacturers. Dependable performance is the reason for * acceptance. PyHrauI AC is being used to lul*r. . I' .. cylinders in a number of compressors at pressures over 4500 psig. Many compressors have operated continually with exhaust air temperatures of 340' F. r 06ai088 TOWOLDMON0039555 WATER_PCB-00024024 PYDRAUL AC Extensive field experience has proven that the required lubrication rate with Pydraul AC' closely approximates that of petroleum oils. When installing npw equipment, it is well to cfnrt with an increased lubricant feed rate and reduce hy su<*cossive increments. Inspection of cylinder walls and valves indicates the proper degree of wetting. On installations converted from petroleum oil to Pydraul AC, the same feed rate as for the petroleum fluid should boadequote. HAS NORMAL USE RAIL 0621089 TOWOLDMON0039556 WATER_PCB-00024025 CONVERTING TO PYDRAUL AC IS EASY The conversion of air compressor systems from petroleum lubricants to fire- and explosion-resistant Pydraul AC is simple, but one procedure is vitally important to insure smooth, efficient operation with Pydraul AC. Exhaust valves and interstage equipment should be thoroughly cleaned before installation, because Pydraul AC will loosen carbonaceous deposits, which may cause unnecessary maintenance down time and production loss. Once the valves have been thoroughly cleaned of harmful carbon deposits, Pydraul AC keeps them clean--lets you run longer between maintenance shutdowns. standard check for compressors plastic separator bowls Not all plastic separator bowls are suitable for Pydraul AC service because certain plastics are "crazed" or softened when exposed to it. Though separator bowls can be molded of plastics that are totally resistant, for the present it is safest to use glass, brass or steel bowls. If there is a question as to the resistance of a particular plastic, Monsanto will be happy to advise if the material is suitable. diaphragm valves Pydraul AC has a softening effect on the "Neoprene" or Buna N rubber diaphragms that are normally used for petroleum oil service. These rubbers should be replaced with butyl rubber material which is resistant to Pydraul AC. Butyl diaphragm sheeting is available from normal sources of supply. All diaphragms in unloading valves or downstream control valves should be replaced at the time of changeover. Diaphragms in valving downstream from separator systems or drying systems need not be replaced at changeover time, but should lx- changed on a preventive maintenance schedule as soon as practicable after operation on Pydraul AC is begun. 0621090 TOWOLDMON0039557 WATER_PCB-00024026 special check for splash - lubricated compressors crankcase paint Since the pnint used on crankcase interiors of some compressors will in most eases !>e softened and eventually removed hv Pydraul AC. the pnint should (*? removed. While the paint particles might pass through the lubricant pump, they could conceivably block the lubricant passages. Therefore, removing this paint is good practice. Standard jxiint solvents are adequate for removing the jiaint. special check for force-feed lubricators sight-glass fluid If a separate force-feed lubricator of the type normally filled with water and glycerine is used, one of two changes is necessary either replace the sight-gloss fluid with one heavier than Pydraul AC or insert a metal bohtx-r in the sight-glass. Pydraul AC is heavier than water or glycerine and will not rise through these standard sight-glass liquids. "Fluorochomicnl 101." a clear liquid supplied hv the Minnesota Mining and Manufacturing Company, has a higher density than Pydraul AC and is a completely satisfactory replacement. metal bobbers The alternate to using "Fluorochomical 101" is to modify the sight-glass lubricator by inserting a simple metal bobber. The bobber is installed by draining the sight-glass liquid, removing the guide wire and inserting the bobber. Operation of the lubricator is then indicated by movement of the bobl>er with each stroke of the pump plunger instead of counting the drops ns with guide wires Boblxws are available for either McCord or Manzell lubricators ns McCord part number A2uS4?> or Mnn/.el! part numlx'r 82-1021-B. Modification of the Mndison-Kipp lubricator nxjuires replacement of the entire sight-glass with their number C-CV-300 oil feed indicator. vacuum-sight lubricators Vacuum-sight lubricators require no modification for Pydraul AC usage. C6lC9i TOWOLDMON0039558 WATER_PCB-00024027 PYDRAUL. AC AS SAFE TO USE "Pydraul AC has an extremely low order of oral toxicity to experimental animals. This, together with experimental data which shows that rate survived a 6-hour exposure to an atmosphere saturated with Pydraul AC vapors, attests to its safety for use in air compressor systems. The material is irritating to the eyes and can cause smarting and burning, but no permanent damage has resulted." ........ Monsanto Medical Department 0621092 TOWOLDMON0039559 WATER_PCB-00024028 <0 Id P x id IL 0 c 1 J < 0 i fc Viscosity. <SUS) 50' F. 75 F. 100 ' F. t.30 F. 210' F. Four point, F. Neutralization number Specific gravity. 00 /G0" F. Auto-igniting temperature Solubility of water in Pydraul AC 75' F. 210' F. Solubility of Pydraul AC in water 15.000 1.650 410 127 43 20 0.15 maximum 1.35 1.100"' F. 0.1 per cent 0.4 per cent Negligible For applications requiring significantly different proper ties, such as intermittent operation of a portable compressor in areas of loir ambient temperature, a fluid similar to Pydraul AC can he prodded. Contact Monsanto's Functional Fluids Drfxirtnient for details. Shipping Information Classification. U.S.A. Regulations Standard Containers Chemicals. NOIBN None 55 gnlion, nonrcturnnblo. black iron drums. 610 It's. net. I-gallor drums. 55 lbs. net 0621093 TOWOLDMON0039560 WATER_PCB-00024029 TO ORDER PYDRAUL AC CONTACT THE SALES OFFICE NEAREST YOU For samples or additional information, write Monsanto Chemical Company. Organic Chemicals Division. Functional Fluids Sales, P. O. Box 478, St. Louis 1. Mo, AKRON ATLANTA BOSTON CHICAGO CINCINNATI CLEVELAND DETROIT HOUSTON LOS ANGELES MINNEAPOLIS NEW YORK SAN FRANCISCO SEATTLE WILMINGTON LONDON MELBOURNE MONTREAL TORONTO VANCOUVER 920 BROWN STREET. AKRON 11. OHIO 1401 PEACHTREE STREET NE. ATLANTA 5. SA. EVERETT STATION. BOSTON 49. MASS 520 N. MICHIGAN AVENUE, CHICAGO 11. ILL 2330 VICTORY PARKWAY. CINCINNATI 6. OHIO 427 HANNA BUILDING. CLEVELAND 15. OHIO 18230 GRAND RIVER AVE.. DETROIT 23. MICH. 904 CITY NATIONAL BANK BLDG.. HOUSTON 2, TEXAS 670 E. FLOTILLA STREET. LOS ANGELES 22. CALIF. F05HAY TOWER. ROOM 409. MINNEAPOLIS 2. MINN. 445 PARK AVENUE. NEW YORK 22. N. Y. Ill SUTTER STREET, SAN FRANCISCO 4. CALIF. 911 WESTERN AVENUE. SEATTLE 4, WASH. 4335 GOV. PRINTZ BOULEVARD. WILMINGTON 99, DEL. MONSANTO CHEMICALS LTD. MONSANTO CHEMICALS (AUSTRALIA) LTD MONSANTO(CANADA) LTD Representatives in the Pnncijxil ('Hie. <>j the World. 062109*, HP M-. " ' ' '< - .... ' ` ' C -. , WATER_PCB-00024030 I 0621095 TOWOLDMON0039562 WATER_PCB-00024031 monsanto chemical company st. louis, missoun 062106 TOWOLDMON0039563 WATER_PCB-00024032