The Method Used by the U. S. Public Health Service
t
D^TMBUTION-
A. Riddle .
for Enumeration of Asbestos Dust on Membrane Filters
L. f.`y?rs'.
Q.. M-vf-ten Q .
C. ;Y:,wor Q-"
George Ht Edwards and Jeremiah R. Lynch
A J-J(
f.'c - - .
ut E
:- 7 ,
n;
-iV'.' 7m Q
/ .A. '..-is A: d
Ci. L Vassals- Q 1. West ; . ilie " . Q
Introduction
.
.
.
'
In the early epidemiologic studies of the asbestos industry by Pulton (1935) and Dreesen (1938), the impinger was settled upon as the stands ard method for appraising dustiness. Since few fibers were seen it was necessary to count both grains and fibers to obtain a statisti cally useful count despite the assumption that asbestosis was caused by fibers. This inconsistency notwithstanding, dust control based on
impinger results has greatly reduced the incidence of asbestosi3 where
it has been conscientiously applied in the asbestos textile industry. However, a number of investigators (lynch and Smith, 1955; Doll, 1955) have suggested other health hazards associated with asbestos, and a more relevant' and sensitive method is required for estimation of the hazard, especially in industries using only part asbestos in their product.
A further weakness in the impinger method is that it is not amenable to long personal samples. It is believed that personal samples best approximate the worker's actual exposure, and Roach,(1966)has rccm- . mended a sample duration of ten work shifts for mineral dusts.
New methods were therefore needed, and among those studied were fiber
counts at 430X phase contrast on membrane filters that had been made
transparent. This paper deals with the development and standardiza
tion of this method.
.
.
The principal variable which needed to be considered was the mounting .
procedure in relation to maximum transparency and the effect of time on
the dimensional stability of the mount. Methods using inmersin oil, air
plane glue or acetone were found to be either too cumbersome or resulted
in an imperfectly cleared or mottled filter, particularly as viewed with
phase contrast optics. In methods which involved the application of
.
liquid over the dust deposit the movement of the meniscus across the
deposit sometimes caused redistribution of the dust. The use of a 50-50
*U. 3. Department of Health, Education, Public Health Servie* - NCUIH Occupational Health Progrs 1014 Broadway, Cincinnati, Ohio 45202
and Welfare
1
t I i
The Method Used by the U. S. Public Health Service ... ' _for Enumeration of Asbestos Dust on Membrane Filters
. .. v George H. Edwards and Jeremiah R. lynch
a
ABSTRACT
r
Samples of air-borne mineral dusts are collected by drawing air through
~ . .cellulose membrane filters* Particles smaller than nominal pore size
: are retained. Varying sampling rate and filter holder controls the
i distribution of dust across the filter face* Samples are mounted on
*
standard microscope slides using a high viscosity solution of membrane
filter material in a mixture of diethyl oxalate and dimethyl phthalate
to render the filter transparent. The mount is stable for 28 to 30
. . days, but after this period migration of the dust particles causes a
.
loss of areal concentration.
The dust particles, which lie on the surface of the filter, are counted
with a phase contrast microscope, using 10X eyepiece and a 4 mm "high-
dry" objective. The field area is delineated with a Porton reticle.
Count data are recorded in a form allowing data reduction and statis
tical analysis by electronic computer. This method is suitable for
experimental studies' of most mineral dusts, but cannot at present be * -
used in connection with Threshold Limit Values. 74/-*
/1
.oUdecL O.S < cc.tpfzl'A. ij,
~rt. ///y-
l
*u. S. Department of Health, Education, and Welfare
Public Health Service _ jfCUIH
--- ....
Occupational Health Program
.
1014 Broadway, Cincinnati, Ohio 45202
I
L
e -
'- a 4 *
Q9 Q22
- 2 -
mixture of diethyl oxalate-wiimethyl phthalate was attempted and found to result in satisfactory clearance* However, since this medium dis solved the filter, the migration of particles resulted in changing counts with time and needed to be examined to evaluate the method.
Sampling Procedure
.
'j . .
R Samples for count are collected on Millipore type AA filters by
personal samplers operated by battery powered pumps worn by the ea-
ployees, and as simultaneous samples collected in conjunction with '
impingers. The filters are contained in plastic filter holders and
are supported on thick pads which also aid in controlling the distri
bution of air through the filter. Several methods of admitting air to
the filter have been attempted. With the face cap removed and the
filter completely exposed, the air may enter the filter evenly, but
large high velocity particles and foreign objects may also hit the
filter and possibly cause damage. As an alternative, the face cap may
be left in place and the small plug removed. The passage of air through
this 4 mm opening at a flow rate of 2 liters per minute produces a velocity of 265 em/sec, which yields an impaction parameter of 0.081 for
1 micron (u) unit density spheres. Although this impaction parameter
would predict a very low collection efficiency of 1 |i particles by im
paction, some larger particles would tend to be impacted on the center -
of the filter. This was found not to affect count distribution, which
is dominated by small particles; however, it does result in obscuring
a small portion of the filter, particularly if many large particles
are present, as in friction product plants. The third alternative was
to drill six additional 4 mm holes in some face caps and to fit these
perforated caps to the filter holder during sampling. This reduced
the velocity to 38 cra/sec thus eliminating the impaction problem while
still protecting the filter from damage.
' ~
Mounting the Sample
The mounting medium used in this method is prepared by dissolving
. 0.1 gm of membrane filter material per ml of a 1:1 solution of dimethyl
phthalate and diethyl oxalate. The exact proportions of the 3 compon
ents are not critical, but the medium must have as high a viscosity as
possible without being difficult to handle. The index of refraction
of the mediua thus prepared is No - 1.47*
|
To prepare a sample for microscopic examination, a drop of the mounting
medium is placed on a freshly cleaned standard (25 nm x 75 ran) micro scope slide, using a dropper or applicator. The volume of the drop is
approximately 0.05 ml. A wedge-shaped piece about 1 cm by 2 cm is
excised from the filter using a scalpel and forceps, andplaced dust side up on the drop of mounting solution (Figure .1). A g l - V * coveiv slip carefully cleaned with lens tissue is placed over the filter wedge. Slight pressure on the c o v e m l i p achieves contact between it
and the mounting medium.
- 3 -
Clearing ,of the filter with this method i3 alow, requiring about 15
minutes. The sample may be examined as soon as the mount is trans parent.
The transition of the dust-supporting substrate from translucent, solid
membrane filter cellulose ester material to a transparent, optically
homogeneous gel is very gentle, and at no time does a meniscus sweep
across the dust deposit. Rather, the substrate slowly softens beneath
the dust, and there is no opportunity for washing away or redistribu
tion of the dust.
The optical homogeneity of the resulting mount is nearly perfect, with only a slight background granularity under phase contrast, which dis
appears within 1 or 2 days.
Stability
Observers noted a reduction with time in apparent concentration for
samples mounted with only dimethyl phthalate and diethyl oxalate. Ry
observation, this loss was due to the migration of the dust particles
outward from the center through the gelatinous material of the fixed
mount, with a decrease in areal concentration. To determine the mag
nitude of this loss, a group of samples was mounted using 1:1 dimethyl
phthalate and diethyl oxalate only, and counted at one day to thxee-day
intervals for periods ranging up to 76 days. Counts were displayed as
fractions in percent of the original, or first day counts (Figure 2).
At the end of one week, samples mounted by this method yielded only
15% of their original values. Ry 30 days after mounting, the counts
using this method had declined to U0% of their first day value, and
continued at this level with no further decline until counting was
terminated 76 days after mounting.
___
A group of samples mounted in the method described in the section "Mounting the Sample" using high-viscosity mounting medium were counted at one-day intervals for eleven days. No loss of areal concentration was apparent over this short period and a second group was similarly mounted and counted for a period of forty-six days. The composite of these two series is shown in Figure 2. No loss of concentration was detectable during the first 30 days, but the count declined to 85% o
its original value by the 46th day, when the series was terminated.
A 6 urn square of membrane filter with a vacuum-deposited film of car
bon was mounted in the manner described to provide a macroscopic observation of the distortion of the filter areas. After a few days, the square began to. disintegrate at the edges, but the major portion showed no discontinuity during the initial 30 day period. By the end of 62 days, most of the square had disintegrated aid the fragments
migrated over an area 16 mm by 17 mm. '
.i
-A
Evaluation
The filter samples mounted in the manner previously described are
evaluated in terms of grain and fiber concentration, and fiber size.
Binocular research microscopes equipped with fixed mechanical stages
have been used. Phase contrast optics fitted to these instruments
include an Abbe condenser with rotating phase turret and a A mm
"high-dry1* achromatic objective used for all membrane filter determina
tions. In all cases 10X Huygens eyepieces, one of which contained a
Porton reticle at the level of the field--limiting diaphragm, were used.
The left half of the Porton reticle field served to define the counting
area or field.
.
.
A ribbon filament illuminator was critically adjusted to provide Kohler illumination through a clear blue filter.
TWenty field located at random on the sample were counted and total
grains, total fibers, fibers greater than 5 U, and fibers greater than
10 u were recorded. Any particle having an aspect ratio of 3 or greater was considered a fiber.
Recording of Data
Since it was recognized early in the study of the asbestos products industry that the large number of samples to be collected would present a burdensome data processing problem, the data were collected on forms designed for transcription to punch cards (Figure 3). Computer programs were then written to calculate dust concentrations and to produce sta tistical summaries consisting of mean, standard deviation, median, etc., for any group of samples by plant, operation, Job, type, etc. These programs, written in Automath (Fortran II) are applicable to any prob lem using the sample and count forms as source documents. Additional analyses possible are correlation and regression of simultaneous samples and Poisson index of dispersion of field counts for various counters.
A method for sampling and counting asbestos dust using membrane filters has been developed and evaluated. The mounting medium developed clears the filter gently so as to not redistribute the dust deposit, and pro duces a mount with adequate dimensional stability for a period of thirty days. This method has been used in developing environmental data in connection with the Public Health Service study of the asbestos products industry, and is recommended for research studies in other dusty trades although not for application to Threshold limit Values* A system of data handling involving electronic computer processing, which is also applicable to other studies, was dlsouneed*
4' Q 6 3 5
References
Doll, R. Mortality from Lung Cancer in Asbestos Workers. British
Journal of Industrial Medicine, 12: 81-85 (1955)*
Dreesen, W. C., J. M. Dalla Valle, T. I. Edwards, J.^M. Miller, and
R. R. Sayers. A Study of Asbestosis in the Asbestos Textile Industry.
Public Health Bulletin No. 241, U. S. Government Printing Office,
Washington, D. C. (1938).
-
Fulton, W. B., A. Dooley, J. L. Matthews, and R. L. Houtz. Asbestosis Pennsylvania Department of Labor and Industry, Special Bulletin 42
lynch, K. M. and W. A. Snith. Carcinoma of Lung in Asbestos-Silicosis American Journal of Cancer, 2 5 6 - 6 4 (1935).
Roach, S. A. A More Rational Basis for Air Sampling Programmes. Am. Ind. Hyg. Assn. J., 27, 1 (Jan-Feb. 1966).
i
NOTE:
;
i)
Millipore^ filters are named in this paper since the method was
developed using this brand of filters. However, this does not imply
indorsement by the United States Department of Health, Education, and
Welfare or the Public Health Service. Similar techniques may be developed for other filter brands.
I
}' A 9 6 3
P E R C E N T --OR Gl NA L P A R T IC LE COUNT
3 10 1
FCS 7/64
1
4
MO. DAY YEAR PLANT NO. SAMPLE NO.
11111 r m . c m
5
10 II
13 14 QBJ IS
ESI TYPE NATURE
17 18
E3 CDCTI COUNT COUNT. POWER*M.NO.
18 T 20 21 22 23 24
TTTTTTim ILLUMINATION GRAINS FIBERS > 5 > 10 NQCTS.
l'f ' P C
25
26 27
BLANK
35 36 37
GRAINS
TOTAL
1
Tl
39
*43
42
46
44
48
46
52
40
' v
' 52
54
.
56
' " .
58 * 60
62
: .
64
66
68
70
fibers
>5
LL 39
42 44
48 50 52 54 56 58 60 62 64 66 68
- 74
74
BLANK NO. fO
78
78
> 10
I4 39
42
46 48 50 52 54 56 58 60 62 64 66 68 70 T3 74 7
78
S
AVG
Figure 3.
. '
`
*
Count tabulation form used fop the evaluation of dust samples taken on membrane filters* M " Membrane filter, U ELutri-- ated membrane filter, B - Breathing zone sample, G - General a sample, P " Personal sample, S Sequential sample, C * Count (1st), R - Recount. "COUNT" provides for the techni cian's initials, "OBJ POWHl" indicates the magnification, "M.NO" provides for the microscope number for calibration . purposes, ani LF and PC are light-field and phase contrast.
/
9e3