Document JrO2Qj0bvyDb8B1R6nJdybzzr
REGISTERED MAIL
south charleston plant
UNION CARBIDE CORPORATION CHEMICALS AND PLASTICS
P.O. BOX 8004, SOUTH CHARLESTON. W. VA. 25303
August 3, 1978
Mr. Peter Schaul U. S. Environmental Protection Agency
Region III 6th and Walnut Streets Philadelphia, Pennsylvania 19106
Subject:
Evaluation of Leak Detection Program, UCC, South Charleston, CDS No. 50-0760-10001
W.Va.
Dear Mr. Schaul: The requested information which was not readily avail
able during your inspection of our facilities is hereby sub-
mi tted.
1. Secondary control device burner
residence time is 3.1 seconds.
2. Total flue gas throughput of secon
dary control device burner is 2.19 x 10 CFH at 2000 F. Gas flow rate
range at SVR Unit, ducted to the secondary control device is 400 -- 600 SCFH. VCM range is 16 -- 26 lb/hr. (4 grab samples/flow measurements) 3. Concentration of VCM after the secon dary control device is 0.13 ppmvn,cm,iUri
(geometric mean, 10 - 8 hr. shifts which includes all normal operating
conditions, e.g., receiving VCM from
storage).
UCC 104312
Mr. Peter Schaul August 3, 1978 Page 2
4. Gas standards (cylinders) used for calibration of our continuous moni toring system are prepared from certified vinyl chloride purchased from our suppliers. Before use each standard is analyzed in our laboratory by comparison to a calibration curve freshly prepared from three gas mixture standards (5 , 10, and 50 ppm vinyl chloride in nitrogen cylinders, certified by the gas manufacturer).
5. Continuous monitor sampling point locations in relation to floor level and equipment in vinyl chloride service are illustrated in the enclosed drawings.
6. A series of three (3) GC columns are used in our Model 1200 VFA continuous monitor: a. 20% Igepal CO-880 on Chromosorb P AW DMCS (60/80 mesh) 1/8 in. O.D. SS x 18 in. b. Same as (a) except for length, i.e., 43* ft. c. 20% Octoil "S" on Chromosorb P AW DMCS (60/80 mesh), 1/8 in. O.D. SS x 3 ft.
UCC 104313
Mr. Peter Schaul August 3, 1978 Page 3
Please let us know if there are further questions.
Very truly yours,
William C. Young
WCY/pl Enclosure
cc:
Mr. William Battye
GCA/Technology Division Burlington Road Bedford, Massachusetts
01730
UCC 104314