Document JrMVNnYjEQdV1nEq00mwmdQnX
ENVIRONMENTAL PROTECTION AGENCY
Southeast Water Laboratory College Station Road
Athens, Georgia 30601 December 13, 1971
Mr. Gene Wright c/o Monsanto P.0. Box 249 Anniston, Alabama
Dear Mr, Wright:
Attached is our pesticide analytical procedure that is also followed for PCB analysis. The method was developed by the Fish-Pesticide Research Laboratory, U. S. Department of Interior, Columbia, Mo. As I mentioned in our telephone conversation, if DDT and its metabolites interfere in PCB analysis, the PCB isolation procedure of Armour and Burk will eliminate the interference.
If I can be of further service, please call on me.
Sincerely,
EWL/ka
E. William Loy, Jr. Chemist Analytical Services
DSW 009984 STLCOPCB4001630
Dry Icc Homogenization Procedure for Fish Samples in Pesticide Residue Analysis
A technique for homogenization of fish and other biological samples with resilient tissues is described.
The sample is frozen, sectioned into small pieces,
and ground with dry ice in a blender. This method fragments the embrittled tissue into a fine homogenate without lire aid of a desiccant.
; t
Accurate sampling of large organisms for residue analysis is difiicull to achieve since such samples are not ho-
-*- mogenous and pesticides are not uniformly distributed throughout the tissues. A coslty method of achieving accu racy is to extract till or a major portion of a sample. However, most investigators use homogenization of the tissues, assuming that a portion of the sample will be representative of the whole.
Many authors have reported homogenization techniques for biological samples. Thai of Davidow (1950), typical of the labor ious procedures commonly used, required that the sample be ground with anhydrous sodium sulfate by use of a mortar and pestle. Kallman ef a!. (1962) reported the use of a blender to grind tissue with sodium sulfate. An interesting technique was reported by Parker cl a!. (1965) in which they used dry ice as a grinding aid. In this communication we describe a method, based on the use of dry ice, by which fish are pulverized into a finely powdered homogenate.
pulverize. Enough dry ice should be used to equal or slightly exceed the weight of the tissue sample. Hold a cloth or large lab wipe over the vent hole in the blender top to prevent loss of material. (CADI ION: Hold the cloth or lab wipe in place with a leather glove to prevent frostbite.) Add the sample and begin blending at low speed. When the sample is blending smoothly, increase to maximum blending speed. Continue blending until (he sample is reduced to a fine powdcr. The total time required will depend on tire size of the sample, but will usually be from 3 to 5 min. Sample size with the 1-1. container can vary from 30 to 2W) g. A *1-1. container may be used for samples up to SOU g.
Pour the pulverized mixture into a plastic bag, close the top of the bag with a rubber band, and store the comminuted sample in a freezer overnight. This allows complete sublimation of the dry ice, which (tikes approximately 7 hr. After overnight storage the sample is ready for extraction,
!
j
i j
J j ' i < !
; > j
MA I TRIALS AND EQUIPMENT
Mender container and motor unit -A 1-1. Waring stainlesssteel container was modified by enlarging the vent bole to */j in. and changing (lie pitch on the lower pair of blades from -t 2 to -- 15. These changes allowed the C02 gas to escape and assured efficient blending. The nuiltispccd Waring base Wits rated tit 120 v and K00 watts.
Miscellaneous equipment--Other supplies needed include: a heavy knife or meat cleaver; a 2-!b mallet; it hardwood cutting board; plastic bags; dry ice; styrofoam container; leather gloves; and a freezer.
METHOD
Whole fish are frozen to facilitate cutting and grinding, as well ns to presene the sample. Remove the sample from the freezer, weigh, and slue it into pieces using the knife anti mal let. for optimum blending, the sliced sections should not exceed the following dimensions: '/3 X '/ X 1 in., cross, sagittal, ami longitudinal sections, respectively. Monk the dry ice into '/- in, chunks, place them into the blender, and
DISCUSSION
Complete sample homogenization is essential when accuralely quantitating pesticides in biological samples, especially fish, where the fat is heterogeneously distributed (Love, 1962).
Homogenizing whole fish with a desiccant (considered standard procedure by many researchers) is a tedious task. Often, the sample requires several refreezings and regriiuiings before the resilient tissues, i.e., skin, muscles, and cartilage, can be completely macerated. Calculations are eomplicated by having to contend with a desiccant factor and the chemical properties of the desiccant. The dry ice procedure eliminates the desiccant and keeps the frozen tissue brittle and vulnerable to fragmentation.
A large fish weighing approximately 300 g was homogenized and five 30-g subsamples were taken for pesticide analysis (DDE, DDD, and DDT). The analytical results obtained agreed with alternate grinding procedures (I ish-l'esticide Research Laboratory, 1969). Neither the weight of the fish nor the way the plastic bags are settled apparently aficcts the dissipation of the dry ice.
Certain precautions should be exercised when employing the dry ice technique. Since breathing a K)% or higher con-
;
j j j ; ! j ; i J
STLCOPCB4001631
DSW 009985
oil (ration of CO? ran cause death (Merck, I960), the dry ic. (or samples intermixed with dry ice) should not be stored in a poorly ventilated room like a walk-in freezer unless adequate precautions are taken. Gloves should be worn to avoid frostbite when handling the dry ice.
LITERATURE CITED
D,ividtnv, Ik, J. Ass. Offtc. Agr. Chan. 33, 886(1950).
jisli-Pesticide Research Laboratory, Columbia, Mo, 65201,
unpublished data, 196V.
'
Kallman, I). J., Cope, O. Ik, Navarre, R. J., Trans. Amer. Fish. Sac. 91,14 (1962).
Love, R. M., "The Physiology of Pishes," pp. 406-407, Academic Press, Inc., New York, N. Y. (1962).
Merck Index, 7th Ed. p. 21), Merck and Co., Inc., Railway, N. J. (1960).
Parker, K. IX, Dewey, M. L., DeVries, IX M., Can, S. C., Toxicol. Appl. Pharmacol. 7, 719 (1965).
Bureau of Sport Fisheries and Wildlife Fish-Pesticide Research Laboratory Columbia, Mo. 65201
P. E. Benville, Jr.1 R. C. Tindle1
1 Duty Station, Fish-Peslicidc Research Laboratory, P.O. Box 98, Tiburon, Calif. 9-1920.
1 To whom correspondence should be addressed.
Rcccircd for recicw June 75, 1970. Accepted July 13, 1970. The use of proprietary names in manuscript is for purposes of identifica tion only and does not suggest endorsement of these jtroducls by the Ihtreau oj Sport Fisheries and Wildlife, or the U. S. Department ofthe
Interior.
/
DSW 009986
i /, c.D rnnit ruv\x vm ifl wm iq*ia QdQ
STLCOPCB4001632