Document JrGLoLwe4eqb0wazdew4d7QXa
(ip.pE row 1 iii.
Biochemical Research Department THE DOW CHEMICAL COMPANY
^rco /
Sublect: '
INDUSTRIAL HYGIENE SURVEY OP VARIOUS OPERATIONS AT THE CHLORINE CELLS, BLDGS:
261, 196, 137, 295, 236, 270, 303, 207.
Pile Chg.
T34.21-2l-3() 1219
Rec'd. 5/7/48
Pin'd. 3/20/51
Work by H. Hoyle
E. J. Schneider
to:
I. F. Harlow, Bldg. 309 (l)
R. M. Hunter, Bldg. 261 (l)
'
W. R. Perry, Bldg. 261 (l)
Medical Department (l)
"
Att: H. H. Gay, M. D., Bldg. 256
Safety Department (l)
Att: S. M. MacCutcheon, Bldg. 401
1 0 v/Vr/
___ THIS REPORT 15 T
PROPERTY
OF
THE DO'# CHEMICAL COMPANY
STOOG739
SUMMARY AND CONCLUSIONS
1. Significant amounts of chlorine, sufficient to cause, inflammation and swelling of the respiratory system from short
periods of exposure, were found in areas where men were working on and among tie chlorine cell series.
2. Men working in these areas have been getting by without severe exposure by using respirators, however, it must be kept in mind that excessive amounts of chlorine above the maximum allowable
concentration of 1 p.p.m. for an eight-hour exposure do exist among the cell series.
3. No excessive amounts of chlorine were found in the making of bleach solution at the cell brine plant, 303 building.
4. Excessive concentrationsof chlorine occurred in the
loading of ton cylinders with liquid chlorine when the delivery
line became plugged and insufficient time was taken to purge the
connecting lines to the cylinder before removing them.
PLAINTIFF'S EXHIBIT
DOW-120
Biochemical Research Derarcmen. TJ4.21-21-3 Page 2 5. No excessive amounts of chlorine were found during the normal loading of cylinders and no odor of chlorine was noticed during normal operations to purge, test and load tank cars. 6. Excessive amounts of chlorine and sulfuric acid were found while dumping the sulfuric acid drying tower to the sewer. 7. No excessive amounts of alkali dust were found among the chlorine cell series. . 8. No significant amounts of mercury vapor were found at the discharge of the vacuum pumps for the mercury arc rectifiers. 9. Excessive amounts of pitch dust must be considered to exist, since men who are working at the pitch grinding operation do become photo-sensitized and- must limit their outdoor activities. 10. Large amounts of graphite dust were found during the loading of plates into the buckets to be impregnated with phenol formaldehyde resin solution. Since the loading operation involves only an hour or so, the exposure to the graphite dust can not be considered excessive. 11. The graphite dust concentrations found in the machine shop were well within the limits for an inert dust. 12. The worker using the band-saw was found to be exposed to more fine dust than workers at the other machines, possibly because there was no spot exhaust ventilation provided. 13. No excessive amounts of formaldehyde or phenol vapors were found during the making of the phenol formaldehyde resin or during the various drumming operations.
ST006740
ST00674I
Biochemical Research Department T54.21-21-5 Page 3 14. The millions of particles per cubic foot of air of asbestos was found to run higher than the maximum allowable concentration of 5 for an eight-hour exposure for the handling of dry asbestos in cover ing the cell diaphragms. Since the exposure occurs only eighteen times a day for a short period with a total exposure of less than two hours, the amounts of asbestos found cannot be considered excessive. CHLORINE I. Significance of Chlorine Exposure 1. For many years a gas concentration of 1 p.p.m. (by volume) has been used as a standard for evaluating workmens' exposures. Recently there has been some expression of opinion that 2 or 3 p.p.m. could be tolerated up to 8 hours daily without adverse effect. Gag concentrations much above 3 p.p.m. unquestionably produce Irritation (tissue injury) to the eyes, nose, and throat; concentrations above 10 p.p.m. may cause serious effects on single relatively short expos ures. Beginning at about 3 p.p.m. chlorine causes unmistakable pain in the eyes, nose and throat to which very little tolerance develops. This painful action serves as an excellent warning cf the presence of harmful concentrations of gas. There appears to be no evidence of chronic effects from repeated exposures at concentrations of less than 2-3 p.p.m. (concentrations having no Immediate acute effects). Repeated exposures above 2-3 p.p.m., however, may maintain an irritation of the eyes and respiratory passages, produce an erosion of the teeth, and possibly a nonspecific debility.
Biochemical iAe search Department Tp4.21-21-5 Page 4
2. To a large extent the data of Table I, II, III, and IV merely give numerical expression to what has been apparent by sensory perception and experience, that excessive gas concentrations are encountered rather frequently if not routinely. Considering the nature of the operations and that much chlorine comes from unpreventable.or accidental leaks, it 'may not be practical to reduce these concentrations of chlorine. Accordingly,- it is necessary to emphasize the need for proper respiratory protection, the training of workmen, and the provisions for handling leaks. The results emphasize the desirability of medical examinations to assure the workmen are receiving adequate personal protection. If the men show no evidence of injury that is persistent or frequent, then our principal additional recommendation is that every opportunity to lessen chlorine contamin ation be utilized. II. Observation and Presentation of Data
1. The odor of chlorine was ever present throughout the cell buildings and from time to time it was noticed that the men were required to use their respirators in order to go about their work.
2. Air samples were collected at several locations and on different days. The results of the air analyses are collected in Table I and II and can be compared with the accepted maximum allowable concentration of 1 p.p.m. for an eight-hour exposure.
ST0067li 2
Biochemical Research Department T54.21-21-5 Page 5
TABLE I
Vapor Concentration of Chlorine Found Among the Cell Series in Building 137
Location
p.p.m. (by Volume)
1. Center aisle between series 45 and 46 (10-4-49)
and 1.44 cloudy/raining
2. Center aisle between series 41 and 42 (10-4-49)
5. Centeraisle between series 57 and 58. (10-4-49)
4. Center aisle between series 55 and 54.(10-4-49)
5. Between series 45 and 47
(10-4-49)
6. Between series 41 and 45
(10-4-49)
0.72
0.51
0.51 0.51 2.16
II t!
11 11 11 11 11 11 11 n
II
11 it 11 11
7. On top series 45
(10-5-49)
1.15" cool and clear
8. Between series 46 and 48
(10-5-49)
6.80' "
"
9. Between series 42 and 44
(10-5-49)
4.00 " "
"
10. On top series 46
(10-5-49)
5.50 " "
"
11. Between series 55 and57
(10-5-49)
1.44
ST0Q6743
12. On top series 55
(10-5-49)
1.44
15. Between series 51 and52
(10-5-49)
2.16
14. Between series 58 and40 15. On top series 56 16. Between series 52 and54
(10-5-49) (10-5-49) (10-5-49)
1.15 1.15
0.51
17. Near compressors
(10-5-49)
18 Center aisle near 15,14,15,16,17,18 series
19. On top series 59 repairing leak
(10-6-49)
0.51
0.51 and
2.16 cloudy /raining
20. Near two mechanics repairing corapressor(l0-4-49) 4.40
21. On top series 46 (when back pressure
operator added water)
(10-6-49)
7.50
22. Between series 15 and 17
25* On top series 15 24. Between series 16 and 18
2ip5. UOnll tUoUpp BsCeir'XieCOs l--o--'
,,,
2o. On top series 5 repairing leak
.
(10-6-49)
(10-6-49) (10-6-49) /('-1t0-,6O-4I9,q)\ (ll-lo- y;
0.72
0.51 " 1.44 "
It
It II
II tl
0 72 "
5.29 cool and clear
.ciocnernicai Research Be oarsmen T34.21-21-3 Page 6
TABLE II
Vapor Concentration of Chlorine Found Among the Chlorine Cell Series in
Building 295
Location
p.p.m. (by Volume)
1. Between series 93 and 95 2. Between series 92 and 94
(11-18-49) (11-18-49)
3- Between series 93 and 95 and on top (11-18-49)
4. On top series 103
(11-18-49)
O.36 clear and cool
0.36
11 It
0.72 " 11 II
1.53 " II 11
5. On top series 104 6. On top series 110
(II-3O-49) (11-30-49)
1.13 " O.36 " n 11
7. On top series 109
(11-30-49
4.4
it 11
8. On top series 103
(11-30-49)
5.6
n ii
9. On top series 101 (men setting it up)(11-30-49) 14.8, 9.4 n 11
10. On top series 99 11. On top series 98
(11-30-49) (11-30-49)
11.5 10.8
11 11 11 it
12. Center aisle near series 92, 93, 94, 95 (11-30-49)
2.56
it it
3. In the chlorinating of the cell caustic for bleaching
ST0067UU
solution at the cell brine plant no irritating or excessive amounts
of chlorine escaped during the normal operation.
The results of air analyses collected during the preparation
of the bleaching solution are shown in Table III
TABLE III Vapor Concentrations of Chlorine Found in the Making of Bleach Solution, Building # 303
Location_ p.p.m. Chlorine (by Volume)
Platform near tank for making bleach solution. In the fumes at the start of bubbling chlorine through the sodium hydroxide In the fumes after one-half hour of bubbling In the fumes after one-hour of bubbling and
finishing batch up
1.1 1.1
1.1
Biochemical Research Desarcme T34.21-21-3 Page 7
4. The possibility of exposure to chlorine vapors during
the loading of tank cars and cylinders was investigated, sensory
perception usually being employed as a measure of exposure. If a
good vacuum was pulled on the tank car and the connecting lines purged,
there was little chance for exposure when 'removing the valves and
testing the car for moisture. With properly repaired valves and
tight connections, there was no exposure during loading.
5. In the loading of cylinders, an inside job, there was
more chance for exposure to chlorine. During one visit the delivery
line for the liquid chlorine became plugged. In removing the connect
ing lines, insufficient time was allowed for purging and excessive
amounts of chlorine were found to exist.'
S'h900iS
6. During normal operation of the filling of the cylinders
no excessive amounts of chlorine were found. The results of air
analyses taken during the leading operation of ton cylinders are
collected in Table 17.
Table 17
7apor Concentrations of Chlorine Pound During the Pilling of Ton Cylinders of Liquid Chlorine, Bldg- 270 (11/15/50)
Location
p.p.m. ___________________________________________
1. Breathing zone of operator as he disconnected purge lines from empty ton cylinder
3*12
2. Breathing zone of operator as he disconnects lines from full ton cylinder of liquid chlorine (line became plugged aid insufficient time was allowed for purging)
8.2
Biochemical Research Department T34.21-21-3 Page 8
7. In the operation of changing the drying towers in the
V
cell buildings, high enough concentrations of chlorine and sulfuric
acid were encountered to saturate a respirator.
Table V shows the concentrations of chlorine found during
this operation.
SULFURIC ACID (PLUS CHLORINE)
I. Significance of Sulfuric Acid Exposure
1. Sulfuric acid fume or mist has an acute irritating action
not too different from that of chlorine. . The problem presented by
this mixture is practically the same as that presented by chlorine
alone. The exposure is short and the concentrations sufficiently
low that no great hazard is presented by the operation. It is one
that occurs regularly, however, the one can question whether or
9^9001S
not it is really necessary.
II. Observation and Presentation of Data
1. The odor of sulfuric acid fumes was masked by the
chlorine. Air analyses during the operation showed the presence
of considerable acid fumes, however, the exposure was of short
duration.
2. The results of the air analyses are collected in Table V
and can be compared with the maximum allowable concentration of
'0.25 p.p.m. for an eight-hour' exposure I
(Table V - page 9)
Biochemical Research Dezartmnt
TJ4.31-21-5 Page 9
Table V
Concentrations of Chlorine and Sulfuric Acid Fumes Found During the Emptying of a Drying Tower to the
Sewer, Building 137
Location
(,bpy*
p
tn do volume;
p.p.m. H2S04 (by volume)
1. Operators breathing zone as he opens valve to release sul furic acid from tower to sewer (first series of towers)
2. Area near sewer after the tower was dumped (first series of towers)
5.5 (5 min.) .\
1.5
5.7 (5 min.) 2.3
3. Operators breathing zone as he opens valve to release sul furic acid from tower to sewer, (second series of towers)
13.8 (5 min.)
3*9 (5 min.)
4. Area near sewer after the tower was dumped (second series of towers)
2.9
2.1
ALKALI DUST (PR0BA3LY SODIUM CARBONATE)
ST006747
I. Observations and Presentation of Data
1. No maximum allowable concentration has been established
for alkali, however, based on plant experience, no ^.gnificant amounts
of sodium hydroxide were found,
2. The presence of finely dispersed titratable alkali was
checked by air analyses among the various cell series and the results are collected in Table VI.
Table VI
Location
Dust Concentration of Sodium Hydroxide Found
Among the Chlorine Cells Series in Buildings
137 and 295
nldg. 137
Mgs./cu.meter as NaOH
1. On top of series 47 2. Between series 43 and 47 3. Between series 41 and 43 4. Between series 50 and 48
5.. Between series 42 and 44 6. Between series 14 and 16 7. Between series 34 and 36
8. Between series 15 and 17
(10-6-49) (IO-6-49) (IO-6-49) (10-6-49)
(10-6-49) (11-18-49) (11-18-49)
(11-18-49)
same asII blank II n 11
2.44 2.44 2.18
Biochemical Research Deoartment T34.'21-21-2 Page 10
Table VI (cont'd) Bldg. 29b
9. Eetween series 92 and 94 10. Between series 95 and 97 11. Between series 109 and ill
12. Between series 104 and 106
(11-18-49) (11-18-49) (11-18-49) (11-18-49)
MERCURY I. Observations and Presentation of Data
1.95
0.66
0.80
1.14
1. Air is constantly being evacuated from the mercury
arc rectifiers and discharged into the rectifier room. The pos
sibility of some mercury vapor being given off was checked by
ST00G7U0
sampling at the outlets of the vacuum pumps. The results of the
air analyses are collected in Table VII and can be compared with
the maximum allowable concentration of 0.1 mg./cu. meter. These
concentrations of mercury have no significance whatever.
Table VII
Vapor Concentrations of Mercury.found in the Rectifier Room, Building 137 (11-13-50)
Location
Cone. Hz. Vapor (by volume)
1. Directly beneath the outlet of the low pressure vacuum pump for G-2 skid of mercury arc rectifiers
2. Directly beneath the outlet of the low pressure vacuum pump for G-l skid of mercury arc rectifiers
5. Directly beneath the outlet of the low pressure vacuum pump for H-2 skid of mercury arc rectifiers
4. General air sample taken between skids G-l and H-2. Circulating air shut off for winter conditions
^0.006 mgs./cu. merer <0.006 mgs./cu. met er (0.006 mj s ,/cu. meter (0.006 mgs./ cu merer
ST006749
aiochemical Research Deoarcment T34.21-21-3 Page 11 PITCH I. Significance of Pitch Exposure 1. Goal tar pitch from many different sources has produced a variety of effects in the skin: photosensitivity; acne and other dermatosis; pigmentations and growths, some of which are benign, others malignant. It is said that about half of the cancers at tributable to occupational exposures are due to pitch. The heavier fractions and t ars of some petroleums and of shale oil have similar actions. One obtains the impression from published information that the rather heavy exposures among pitch workers cause a high incidence of skin injuries. 2. It is apparent that the men handling pitch in the chlorine cells come in direct contact with the material, resulting in prolonged and repeated contacts upon some portions of the body. The data in Table VIII indicate a moderately dirty atmosphere. 3. The data in Table IX represent counts of small particles, roughly of particle size 0.1 to 5 microns which may be inhaled. This data indicates that relatively small amounts of pitch dust are being Inhaled. Since the literature contains no reference to toxic effaces attributable to inhalation, we are not greatly concerned about inhal ation of pitch dust. 4. Excessive skin contact with pitch dust is to be controlled by arrangement and design of the process to eliminate manual handling and dispersion of dustby personal protection of workmen,and measures to assure a high degree of personal cleanliness. The clothing and bath requirements on these jobs have been indicated. It is recommended that the men working directly with pitch be given medical examinations at regular intervals.
Biochemical. Research Deoartment
Tp4.21-21-5 Page 12
II. Observations and Presentation of Data
1. Several exhaust hoods had been installed to control the v-
dust exposure when grinding pitch. The men working on the pitch
grinding equipment, however, through known experiences, are apparently
exposed to amounts of pitch sufficient to cause photosensitivity.
2. The results of air analyses taken in the worker's breath
ing zone and in the work area during various operations encountered
in pitch grinding are collected in Table VIII. Table VIII
Dust Concentrations of Pitch Found During the Grinding and Handling Operations in Preparation of Making Cell Cement - Building 196
-L--o--c---a--t-i-o---n-
1. Breathing zone of worker as he opens metal drum of pitch tar and breaks up the contents
C one. Ms--s---.-/-c--u--.- E-m---e--t-e--r65
2. Breathing zone of worker as he shovels broken pieces of pitch into the grinder and dumps buckets of pitch into mills
506
ST006750
5. Breathing zone of worker as he rakes pulverized pitch from the cyclone and shovels it into the buckets
94
4. Breathing zone of worker as he sweeps area after grinding and filling buckets
455
5. Breathing zone of 'worker as he operates the cable hoist to dump bucket of pulverized
pitch into hopper >r the mixer *
209,249
5. The results of dust counts taken in the general area and
during the various pitch grinding operations are shown in Table IX.
(Table IX - page 15)
Table
Biochemical T54.21-21-3 Page 13
IX
Research Becaromsno
Dust Concentrations Pound During the Various Pitch grinding operations and in the General Area
Location (Breathing zone samples taken whenever possible)
m. p. c. f.
(average of several counts)
I. Shaking out broken pitch from metal drum
5
2. Breaking up lumps
7
3. Shoveling broken up pitch into grinder'
8
4. Dumping buckets of ground pitch to mills
5
5. Sweeping up area where pitch is ground.
7
6. Raking out pulverized pitch
"
5
7. Filling buckets with pulverized pitch .
5
8. Sweeping area where buckets are filled
2
9. Dumping bucket to mixer
5
ST00675I
10. Gen. atmosphere near foreman's desk
5
II. Area in front of small mixer while dumping cement to the small mixer with pitch
4
12. Area in front of small mixer while dumping the pitch cement mix
4
13. Area in front: of small mixer with men working on poured casting
5
14. Area of building where men are working to prepare the cell forms
5
GRAPHITE DUST
I. Significance of Graphite Dust Exposures
1. There are a few reports of lung injury (pneumoconiosis)
among persons working with graphite. Nearly all reports have
dealt with natural graphite containing an appreciable amount of
other minerals so that it is not definite that graphite dust alone
has an adverse effect.
T34.21-21-3 Page 14
2. It Is apparent that considerable amounts of graphite are
dispersed in the air, but the counts of particles susceptible to inhal
ation fail to indicate any exposures that are questionable. If workmen
were regularly and uniformly exposed to counts of more than 50*000,000
particles per cubic foot, correction would be called for.
II. Observations and Presentation of Data
1. A dusty atmosphere was created when a worker used an
air hose t> remove the loose graphite from the plates before loading.
There was still sufficient loose graphite remaining on the plates to
make the loading of them very dusty.
2. The results of air analyses made during the loading oper
ations are shown in Table X.
Table X
Dust Concentrations of Graphite Pound During the Loading of Plates into the Buckets in Preparation for Preenatlng with P.F., Bide. 261
Location
Dust Cone. .Mg./cu. meter
STOOG75
1. Breathing zone of worker blowing loose graphite off a stack of plates with an air hose (room closed up for winter conditions)
22o0
2. Breathing zones of two workers as they lead a bucket with graphite plates
2370
3. Several dust cour.os were taken during the plate loading
and in the general atmosphere. The results of these counts are shown
in Table XI. These values can be compared with the maximum allowable
concentration of 50 m.p.c.f. for an inert dust.
4. Several dust counts were taken in the machine shop, both
during the operation of the machines and in the general atmosphere
through the area. The results of these counts are shown in Table XI
also.
Biochemical Research Department T34.21-21-3 Page 15
Table XI
Dust Concentrations of Graphite Found During the Loading of Plates and Various Operations in the Machine Shop.
v
Treating Room
Location (Sample taken in the breathing zone of worker whenever possible)1 11
m.p.c.f. (aver age of several counts)
1. Blowing the loose graphite off the plates before loading them
50
2. . General atmosphere in the room after blowing
55
5. Piling the plates into the buckets
50
4. General atmosphere of the treating room after
finishing the loading of the plates '
10 min.
15 min.
20 min.
50 min.
^5 min.
20.1
-28.3 55>2 30.8 41.0
5. General atmosphere in the treating room in the morning when the plates are unloaded
2.0
Machine Shop
6. General atmosphere in the machine shop early in the morning before work is started
7
ST006753
7. Cutting corners off of boards at band saw
20
8. Running plates through bevel machine
8
9. Near new machine for grooving boards
10
10. Near old machine for grooving boards
9
11. Placing boards in machines
8
12. Removing boards from machines
9
13. Where operator sits after loading machines
10
14. Blowing small area from machines so board is locked in
11
15. Blowing machine off for cleaning
10
16. Sweeping up area around machines
8
(Table cont'd on page 16)
.siochemical Researcn Deoartment
T34.21-21-5 Page l6
Table XI -(cont'd)
17. General atmosphere near foreman1's desk 18. General atmosphere near crib 19. General atmosphere other end of shop 20. General atmosphere office area
8 5 5 4
21 Janitor sweeping floor FORMALDEHYDE .
5
I. Significance of Formaldehyde Exposures
1. None of the exposures measured during normal operation
were excessive.
II. Observations and Presentation of Data
1. In the making of the phenol formaldehyde resin, the odor
of formaldehyde was noticed throughout the room, however, only during
the blowing of the mixing tank was there evidence of eye irritation.
2. In all cases where air analyses were made, the concentration
of formaldehyde found was below the maximum allowable concentration of
5 p.p.n. The results of air analyses are collected in Table XII.
ST006751:
PHENOL-
I. Significar.ce of Phenol Exposures
1. None of the exposures measured during normal operation
were excessive.
II. Observations and Presentation of Data
1. Very little odor of phenol was noticed during the various
operations of making phenol formaldehyde resin. The results of the
air analyses can be compared with the concentration of 10 p.p.m. phenol
found through past company experience to be an acceptable limit.
2. Table XII also shows the results of air analyses for phenol concentration.
Eiochemical Research DeparcmenT54.21-21-5 Page 17
Table XII
Vapor Concentrations of Formaldehyde and Phenol Found During Various Operations of the Phenol Formaldehyde Resin Process, Building 236
Location (Winter conditions - doors and
windows closed)
p.p.m. Formaldehyde
(by volume)
p p m Phenol
(by volume)
1. General air sample taken in front
of reactor and near operator's desk (reactor up to temp.)
1.0
0.40
2. From an elevated platform between the reactor and mixing tank (reactor up to temp.)
3. Next to the mixing tank and oper ator's desk
4. Near the mixing tank as phenol was blown in from trailer outside
5. Near the mixing tank as formaldehyde was pumped in from storage tank
6. Near the mixing tank as air was blown to mix concents
1.0 0.44
1.27 2.8, 2.6
0.87 0,. 69 1.04
7. Near the mixing tank and operator's desk after blowing had stopped
4.0
8. Near the vacuum still (operating) in the area where operator spends considerable time making insulating plugs
1-5
9. Breathing zone of operator filling 100 gal. drum with evaporated P.F. solution
2.9
10. Breathing zone of operator filling four
50-gal. drums with neutralized and evaporated
P.F. solution for the Texas Division
2A
11. Operators breathing zone filling six 50 gal. drums of formaldehyde for Interplant use. (work done outside on cold, windy day)
.60
1.19 1.11
0.87
ST006755
uiocner-acaj. nesearcn Japarc-.enc
T34.21-21-3
Page 18
..
ASBESTOS
I. Observations and Presentation of Data
1. The handling of dry asbestos in making up a slurry of
caustic, water and asbestos does offer an exposure to finely divided
particles of asbestos.
2. The results of dust counts taken in the breathing zone of
a worker as he weighs, dumps, and stirs the asbestos into the slurry
are shown in Table XIII. These values can be compared with the max
imum allowable concentration of 5 m.p.c.f. for an eight-hour exposure.
None of the exposures measured during normal operation were excessive
since the duration of exposure Is short.
Table XIII
Dust Concentrations Pound During the Handling of Dry Asbestos in the Covering; of Cell Diaphragms
*
Location (samples taken in worker'sbreathing zone)
m.p.c.f. (average of several
counts)
1. Dumping bag of weighed asbestos (48 lbs.) to slurry tank
8
2. Stirring and mixing the asbestos with water
10
3. Weighing out: a bag of asbestos
5
ST006756
be -8
MIDLAND, MICHIGAN October 31, 1968
c*i ,
jrfS'
V
ST006757
R. C. Middleton Safety Department Ludington Plant
LETTER DATED OCTOBER 7, CONCERNING HAZARDS DUE TO HANDLING PIPE COVERING MATERIAL CONTAINING ASBESTOS
Asbestos has long been known as a material capable of causing a discrete disease called asbestosis (which is somewhat similar to silicosis - caused by crystalline quartz). In the more or less recent past the subject of hazard due to asbestos has been further complicated by reports in the literature of malignant growths which were associated with the presence of asbestos bodies. The* whole subject is presently under study by the U.S. Public Health Service.
I feel that at this point in time our best bet is to control asbestos dust exposures according to the Threshold Limit Values suggested by the American Conference of Governmental Industrial Hygienists. This Threshold Limit Value is five million particles per cubic foot of air (mppcf). We have done some dust sampling during a variety of operations carried out by pipe coverers. I'll include a summary of this work for your information. You will see that there are some jobs where the numbers of particles in the air are above the 5 mppcf mentioned here. Jobs such as this should be done using a dust respirator which is approved by the U.f. Bureau of Mines for protection against toxic dusts, including silica.
Another approach to the dust hazard is to contrive better control of the dust so that measurements will show less than the 5 mppcf and there will, therefore, be no need for respiratory protection. Generally this is best accomplished by the use of exhaust ventil ation at the point where the dust is being generated.
Biochemical Research Laboratory 1701 Building
HRHsreh
Enc.
cc: R. F. Falk
?ns
; r :o T ir -,,rn my .vo-r-x-is ^ a i : n
various types of pipe covering materials
4-> u *> r> 3 in
V in
CM <u 4->
in 2T
m
>|6. in
V*. m CM
CM
U. o
S
n a a. o oo *+ cm in VVA
a a. 3
ooo ^ cm in VV A
sl a. a ooo VVA
o u o C'
a.
VO >x> --1 ino
t'-
U^rO-4 ^U'
Hino t**-
a> o. o o o o Cl o
c<! EO
E E m
.
cw oc (- *f 4J o Cl
u: -
a t 4-1 C. oc.
eo rt
n to to C7 -- --*
Ci to c? c C 4* --r; -ot' L. -- m,
J ..
*3 -3 C r: o a C3 -V *
<0 C
c o- V O r: u c. a
. r* r r i v.
=l a oo VV
oo VV
a a. oo ^ CM VV
>.>R in in cn On
V.Vs mo ^ as
Vs in o ZT O'
oc
o
CM CM
CM
2T
tc- *
X
o^ oo
o
CM CM
CM
in in
in
ow o *
O
CM CM Oo cn 10
CM C CO
. . o - - - * -O'
n ft
c o. : 4->
O C.
- -o _ <rj
t. m
c 33 ' co
u in cco oo t-
t, in c E -* OiCC CO
aaa ooo ^ cm m VV A
aaa
ooo h cm m VVA
a aa
ooo c\j m
VV A
aaa o oo VVA
V* V.>fc mom
>*>.> rH m o
t*-
V.wy mom
O'
aa
oo -i CM VV
aa
oo f-i CM VV
aa oo VV
aa VV
WVft mo J9 m
V> VI mm 00 c\
vtv CO ON
V.'W. ON
o CM
X
o * CM
m o
CM o cn
:.:a____
ooQ
c. m c E-
Cl CO ha wo
i!
o
m
C CN
' r~
C o
CN s: ``n
O' o
CM
^_
X -**
oo
CM ' CM
mm
O
o
'
CM oO CO cn
%
"
c" '
-. *
o- f? * -
' o o* *J-
. Cl C3. u- - -
c- m o E--
i L^ I 0
S'? It1
!| CO e-2- i
3O
aaa VV A
V.Y* ^ -* mo
i-
aa VV
00 ON
** o CM in.
# cn
E_ "1 f--
OJ "
' f- rj
>
<<
lA* CoN
o'
oCn CM
f- - I
f
i-?-
uc\; o
c
<TJ
('
>> m
tn
c
o i>irn>P
4-)
>>
L0,) =CV
Xo I ^1
CC in C *
3 (.
C. U o
rr. aO
t. C^ u
4->
O t -
a "1
UUV
to. uci: --o oca
c * o
CO
V.
0
1 oCJ1 \*
5 OS
o -<
o oo
*4 r~i --<
*C0l
u. >
(u Ot. C0l u O 10
*O- sCVJ
C* o
" Cbi
o
*O- *10i
5
(11
cm 0 3
l/'f
co
r.
P i!
! Ii i
oo
CD CD
cn cn oo
oZ r /- /-- /
MIDLAND, MICHIGAN October 30, 1968
Richard F. Falk Safety Department 401 Building
Enclosed is a copy of a letter which I received from Bob Middleton.
One of Bob's questions is "what safety equipment, if any, is used by the Midland Division in handling the materials in question?" I feel that you are in a better position to answer that part of the inquiry than I am.
Thank you for your attention to the matter.
H. R. Hoyle Biochemical Research Laboratory 1701 Building
ERHsreh
Enc.
cc: D. B. Morse, Safety Department, 401 Bldg. R. C. Middleton, Ludington Plant
ST006759
THE DOW CHEMICAL COMPANY
LUDINGTON October 7* 1968
V-
ST00676Q
H. R. Hoyle Biochemical Research Lab 1701 Building
Dear Harold:
We are interested in finding out what Safety Precuations are being used by the Pipe Coverers in the Midland Division.
We are using three types of material in the plant. .Our Pipe Coverers spend approximately 50# of their time on outside work and 50# inside.
The materials used are Fiberglass, which has no precautions on the bag, and a product called "Kaylo", which has the following warning on the bag.
THIS PRODUCT CONTAINS ASBESTOS FIBER
If dust is created when this product is handled, avoid breathing the dust.
If adequate ventilation control is not possible, wear respirator approved by U. S. Bureau of Mines.
There is another product which has the following information on the bag.
CAUTION ----- ASBESTOS SHORTS
This product contains Asbestos Fiber. Inhalation of Asbestos, in excessive quantities, over long periods of time, may be harmful.
If dust is created when this product is handled, avoid breathing the dust.
If adequate ventilation control is not possible, wear a respirator approved by the U. S. Bureau of Mines for pneumoconiosis producing dusts.
2- -
I would appreciate it if you would check into these materials as to the harmfull effects to the employee and what Safety Equipment, if any, is used by the Midland Division.
R. C. Middleton Safety Director cr
ST00676
v-r^o/
I am an author of and have read this report comprising _]JLpages with . ------- pages of drawings, photographs, graphs, and checked the data herein against the original entries under Biochemical Laboratory File Number T34.21-21-3;
Signature Signature
Date 9 -/A - SV Date
I finished typing this report on comprising..1^pages and placed therewith
4/6/51 pages"'
of drawings, photographs, graphs from an original draft given me byon1: I have placed in the plant mailcopies of this
report for transmittal to
I. F. Harlow, Bldg. J09 (l) W. R. Perry, Bldg. 261 (l)
Medical Dept. Bldg. 256 (l) Att: H. H. Gay. M. D.
Safety Department (l)
Att: S. M^MacCutcheon , Bldg.
401
Signature
L
Date
~4UT/A--syr
ST006738
\, ~