Document JrDnb21RXKJGd8NR2eGRgQR56
V
I INTRODUCTION This study was undertaken to assess the degree of
exposure to fibrous dust ain brake maintenance procedures
on commercial vehicles and to provide comparative data
relating to a previous study on operators working on
passenger cars.
II INVESTIGATION
Air sampling took plaoe in the garage on the
19th September 1968. Membrane filters, in conjunction with
Casella personal samplers, suitably modified to provide
a flow rate of 200
were used and the following
sampling procedure adopted.
(a) Personal samples were collected from the "brake
blow off" operator (Mr Crone) and the mechanic working in
the adjacent bay (Mr Hillman) during the blowing-off
operation. The filters were then ohanged and replaced
to run for the rest of the shift.
(b) Static samplers were positioned at three points,
A, B and C, about 20-25* from the source of dust
generation and separate samples were collected for the
morning and afternoon shifts.
The sampling positions are shown in Fig.l,
The collected samples were subsequently removed to
the laboratory and, after preparation, examined by
projection microscopy for the presence of fibres greater
than 5ju. (A fibre is defined as having an aspect ratio
equal to, or greater than, 3:1).
... Ill RESULTS
8006 1214
HFM- 005800