Document JrBDerLmkLDpdLbaNJVX43p0a
U------li V. I '
C.
Technical Service Report
JOHNS-MANVILLE ELECTRICAL INSULATIONS AND OSHA REQUIREMENTS
No___ 126A.
Page- 1
Tests conducted without dust control equipment at the Johns-Manville plants, Indicate the following products can be handled and fabricated without exceed ing the asbestos exposure limits established by OSHA.
Insulation Type: FLEXIBLE PAPERS & COMPOSITES
Fabrication:
UNWINDING, REWINDING, SLITTING, SHEARING
PRODUCTS:
NO. 3000 QUINORGO^ NO. 4000 QUINORGO^ NO. 5000 QUINORGO/ TELGARD A
TYPE 5 QUINTERRA TYPE 5 2-PLY QUINTERRA TYPE 3 QUINTERRA TYPE 3 2-PLY QUINTERRA
QUINTEX I QUINTEX II QUINTEX ST QUINTEX III
PLUS ALL ABOVE PRODUCTS COMBINED WITH GLASS CLOTH OR POLYESTER FILM
Insulation Type: ELECTRICAL BOARDS
Fabrication:
SHEARING AND STEEL RULE DIE PUNCHING
PRODUCTS:
NO. 1100 QUINORGOBORD NO. 1200 QUINORGOBORD TYPE 3 QUINTERRABORD
QUINTEXBORD TX-6 QUINTEXBORD ST QUINTEXBORD STC TV BORD
When sawing any of these materials on a band saw or table saw adequate dust control must be Installed on the sawing equipment.
NOTE:
The J-M tests were performed to provide information of general interest. The resultant data does not relieve users of these products from the requirements of sampling their own work areas as established by OSHA regulations. See data page DT-111A for details of J-M tests.
vsi Jonns Manviue electrical insulation
OT-ttA
Utfto In U.S.A.
PlANTfPS EXHBIT
\jJW-S"V