Document Jr9Z7wL56qbBeddwprJ5oXBKZ

^I Monsanto Material Safety Data POLYCHLORINATED BIPHENYLS (PCBs) Emergency Phone No. (Call Collect) 314-694-1000 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION product NAME: POLYCHLORINATED BIPHENYLS (PCBs) Aroclor Series 1016, 1221, 1232, 1242, 1248, 1254, 1260, 1262, 1268 Therminol FR Series MSDS Number: M00018515 Date: 12/95 Chemical Family: Chemical Name: Synonyms: Chlorinated Hydrocarbons Polychlorinated biphenyls PCBs, Chlorodiphenyls, Chlorinated biphenyls Trade Names/Common Names: PYRANOL and INERTEEN are trade names for commonly used dielectric fluids that may have contained varying amounts of PCBs as well as other components including chlorinated benzenes. ASKAREL is the generic name for a broad class of fire resistant synthetic chlorinated hydrocarbons and mixtures used as dielectric fluids that commonly contained about 30 - 70% PCBs. Some ASKAREL fluids contained 99% or greater PCBs and some contained no PCBs. PYDRAUL is the trade name for hydraulic fluids that, prior to 1972, may have contained varying amounts of PCBs and other components including phosphate esters. The product names/trade names are representative of several commonly used Monsanto products (or products formulated with Monsanto products). Other trademarked PCB products were marketed by Monsanto and other manufacturers. PCBs were also manufactured and sold by several European and Japanese companies. Contact the manufacturer of the trademarked product, if not in this listing, to determine if the formulation contained PCBs. In 1972, Monsanto restricted sales of PCBs to applications involving only closed electrical systems, (transformers and capacitors). In 1977, all manufacturing and sales were voluntarily terminated. In 1979, EPA restricted the manufacture, processing, use, and distribution of PCBs to specifically exempted and authorized activities. MONSANTO COMPANY, 800 N. LINDBERGH BLVD., ST. LOUIS, MO 63167 FOR CHEMICAL EMERGENCY, SPILL, LEAK, FIRE, EXPOSURE, OR ACCIDENT Call CHEMTREC - Day or Night - 1-800-424-9300 Toll free in the continental U.S., Hawaii, Puerto Rico, Canada, Alaska, or Virgin Islands. For calls originating elsewhere: 202-483-7616 (collect calls accepted) For additional nonemergency information, call: 314-694-3344. LEXOLDMONOQ6399 Page 2 of 8 2. COMPOSITION/INFORMATION ON INGREDIENTS Chemically, commercial PCBs are defined as a series of technical mixtures, consisting of many isomers and compounds that vary from mobile, oily liquids to white crystalline solids and hard noncrystalline resins. Technical products vary in composition, in the degree of chlorination, and possibly according to batch. The mixtures generally used contain an average of 3 atoms of chlorine per molecule (42% chlorine) to 5 atoms of chlorine per module (54% chlorine). They were used as components of dielectric fluids in transformers and capacitors. Prior to 1972, PCB applications included heat transfer media, hydraulic, and other industrial fluids, plasticizers, carbonless copy paper, paints, inks, and adhesives. Component CAS No, chlorinated biphenyl Aroclor 1016 Aroclor 1221 Aroclor 1232 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1262 Aroclor 1268 1336-36-3 12674-11-2 11104-28-2 11141-16-5 53469-21-9 12672-29-6 11097-69-1 11096-82-5 37324-23-5 11100-14-4 There are also CAS Numbers for individual PCB congeners and for mixtures of Aroclor products. PCBs are identified as hazardous chemicals under criteria of the OSHA Hazard Communication Standard (29 CFR Part 1910.1200). PCBs have been listed in the International Agency for Research on Cancer (IARC) Monographs (1987)-Group 2A and in the National Toxicology Program (NTP) Annual Report on Carcinogens (Seventh). 3. HAZARDS IDENTIFICATION EMERGENCY OVERVIEW Appearance and Odor: PCB mixtures range in form and color from clear to amber liquids to white crystalline solids. They have a mild, distinctive odor and are not volatile at room temperature. Refer to Section 9 for details. WARNING! CAUSES EYE IRRITATION MAY CAUSE SKIN IRRITATION PROCESSING AT ELEVATED TEMPERATURES MAY RELEASE VAPORS OR FUMES WHICH MAY CAUSE RESPIRATORY TRACT IRRITATION POTENTIAL HEALTH EFFECTS Likely Routes of Exposure: Skin contact and inhalation of heated vapors Eye Contact: Causes moderate irritation based on worker experience. Skin Contact: Prolonged or repeated contact may result in redness, dry skin and defatting based on human experience. A potential exists for developing chloracne. PCBs can be absorbed through intact skin. Inhalation: Due to the low volatility of PCBs, exposure to this material in ambient conditions is not expected to produce adverse health effects. However, at elevated processing temperatures, PCBs may produce a vapor that may cause respiratory tract irritation if inhaled based on human experience. Ingestion: No more than slightly toxic based on acute animal toxicity studies. Coughing, choking and shortness of breath may occur if liquid material is accidentally drawn into the lungs during swallowing or vomiting. MSDS #: M00018515 LEXOLDMON006400 Page 3 of 8 Other: Numerous epidemiological studies of humans, both occupationally exposed and nonworker environmentally exposed populations, have not demonstrated any causal relationship between PCB exposure and chronic human illnesses such as cancer or neurological or cardiovascular effects. PCBs at high dosage can cause skin symptoms; however, these subside upon removal of the exposure source. Refer to Section 11 for toxicological information. 4. FIRST AID MEASURES IF IN EYES, immediately flush with plenty of water for at least 15 minutes. If easy to do, remove any contact lenses. Get medical attention. Remove material from skin and clothing. IF ON SKIN, immediately flush the area with plenty of water. Wash skin gently with soap as soon as it is available. Get medical attention if irritation persists. IF INHALED, remove person to fresh air. If breathing is difficult, get medical attention. IF SWALLOWED, do NOT induce vomiting. Rinse mouth with water. Get medical attention. Contact a Poison Control Center. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. NOTE TO PHYSICIANS: Hot PCBs may cause thermal burn. If electrical equipment arcs between conductors, PCBs or other chlorinated hydrocarbon dielectric fluids may decompose to produce hydrochloric acid (HCI), a respiratory irritant. If large amounts are swallowed, gastric lavage may be considered. 5. FIRE FIGHTING MEASURES Flash Point: 284 degrees F (140 degrees C) or higher depending on the chlorination level of the Aroclor product Fire Point: 349 degrees F (176 degrees C) or higher depending on the chlorination level of the Aroclor product NOTE: Refer to Section 9 for individual flash points and fire points. Extinguishing Media: Extinguish fire using agent suitable for surrounding fire. Use dry chemical, foam, carbon dioxide or water spray. Water may be ineffective. Use water spray to keep fire-exposed containers or transformer cool. PCBs are fire-resistant compounds. They may decompose to form CO, C02, HCI, phenolics, aldehydes, and other toxic combustion products under severe conditions such as exposure to flame or hot surfaces. Dielectric fluids having PCBs and chlorinated benzenes as components have been reported to produce polychlorinated dibenzo-p-dioxins (PCDDs) and furans (PCDFs) during fire situations involving electrical equipment. At temperatures in the range of 600-650 degrees C in the presence of excess oxygen, PCBs may form polychlorinated dibenzofurans (PCDFs). Laboratory studies under similar conditions have demonstrated that PCBs do not produce polychlorinated dibenzo-p-dioxins (PCDDs). Federal regulations require all PCB transformers to be registered with fire response personnel. If a PCB transformer is involved in a fire-related incident, the owner of the transformer may be required to report the incident. Consult and follow appropriate federal, state and local regulations. Fire Fighting Equipment: Fire fighters and others exposed to products of combustion should wear self-contained breathing apparatus. Equipment should be thoroughly decontaminated after use. MSDS #: M00018515 LEXOLDMONOQ6401 Page 4 of 8 6. ACCIDENTAL RELEASE MEASURES Cleanup and disposal of liquid PCBs and other PCB items are strictly regulated by the federal government. The regulations are found at 40 CFR Part 761. Consult these regulations as well as applicable state and local regulations prior to any cleanup or disposal of PCBs, PCB items, or PCB contaminated items. If PCBs leak or are spilled, the following steps should be taken immediately: All nonessential personnel should leave the leak or spill area. The area should be adequately ventilated to prevent the accumulation of vapors. The spill/leak should be contained. Loss to sewer systems, navigable waterways, and streams should be prevented. Spills/leaks should be removed promptly by means of absorptive material, such as sawdust, vermiculite, dry sand, clay, dirt or other similar materials, or trapped and removed by pumping or other suitable means (traps, drip-pans, trays, etc.). Personnel entering the spill or leak area should be furnished with appropriate personal protective equipment and clothing as needed. Refer to Section 8 for personal protection equipment and clothing. Personnel trained in emergency procedures and protected against attendant hazards should shut off sources of PCBs, clean up spills, control and repair leaks, and fight fires in PCB areas. Refer to Section 13 for disposal information and Sections 14 and 15 for information regarding reportable quantity, and Section 7 for marking information. 7. HANDLING AND STORAGE Care should be taken to prevent entry into the environment through spills, leakage, use vaporization, or disposal of liquid or containers. Avoid prolonged breathing of vapors or mists. Avoid contact with eyes or prolonged contact with skin. If skin contact occurs, remove by washing with soap and water. Following eye contact, flush with water. In case of spillage onto clothing, the clothing should be removed as soon as practical, skin washed, and clothing laundered. Comply with all federal, state, and local regulations. Federal regulations under the Toxic Substances Control Act require PCBs, PCB items, storage areas, transformer vaults, and transport vehicles to be marked (check regulations, 40 CFR 761, for details). CAUTION CONTAINS PCBs (Polychlorinated Biphenyls) A toxic environmental contaminant requiring speciol handling and disposol in accordance with U.5. Environmental Protection Agency Regulotions40CFR761 For Disposol Information contoct the nearest U.5. E.P.A. Office. In cose of accident or spill, coll toll free the U.S. Coost Guard National Response Center 600-424-0602 Also Contoct .--------------------------------------- cv Tel. No. ------------- ---------------------------------------- -2 CAUTION -- CONTAINS PCBs (Polychlorinated Diphenyls) FOR PROPER DISPOSAL INFORMATION CONTACT U.S. ENVIRONMENTAL PROTECTION AGENCY 5 Storage: The storage of PCB items or equipment (those containing 50 ppm or greater PCBs) and PCB waste is strictly regulated by 40 CFR Part 761. The storage time is limited, the storage area must meet physical requirements, and the area must be labeled. Avoid contact with eyes. Wash thoroughly after handling. Avoid breathing processing fumes or vapors. Process using adequate ventilation. MSDS #: M00018515 LEXOLDMONOQ6402 Page 5 of 8 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Eye Protection: Wear chemical splash goggles and have eye baths available where there is significant potential for eye contact. Skin Protection: Wear appropriate protective clothing and chemical resistant gloves to prevent skin contact. Consult glove manufacturer to determine the appropriate type glove for a given application. Wear chemical goggles, face shield, and chemical resistant clothing such as a rubber apron when splashing is likely. Wash immediately if skin is contacted. Remove contaminated clothing promptly and launder before reuse. Clean protective equipment before reuse. Provide a safety shower at any location where skin contact can occur. Wash thoroughly after handling. ATTENTION! Repeated or prolonged skin contact may cause chloracne in some people. Respiratory Protection: Avoid breathing vapor, mist, or dust. Use NIOSH/MSHA approved equipment when airborne exposure limits are exceeded. Full facepiece equipment is recommended when airborne exposure limits are exceeded and, if used, replaces the need for face shield and/or chemical splash goggles. Consult respirator manufacturer to determine the type of equipment for a given application. The respirator use limitations specified by NIOSH/MSHA or the manufacturer must be observed. High airborne concentrations may require use of self-contained breathing apparatus or supplied air respirator. Respiratory protection programs must be in compliance with 29 CFR Part 1910.134. ATTENTION! Repeated or prolonged inhalation may cause chloracne in some people. Ventilation: Provide natural or mechanical ventilation to control exposure levels below airborne exposure limits (see below). If practical, use local mechanical exhaust ventilation at sources of vapor or mist, such as open process equipment. Airborne Exposure Limits: Product: Chlorodiphenyl (42% chlorine) OSHA PEL: 1 mg/m3 8-hour time-weighted average - Skin* ACGIH TLV: 1 mg/m3 8-hour time-weighted average - Skin* Product: Chlorodiphenyl (54% chlorine) OSHA PEL: 0.5 mg/m3 8-hour time-weighted average - Skin* ACGIH TLV: 0.5 mg/m3 8-hour time-weighted average - Skin* *For Skin notation see Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices. American Conference of Government Industrial Hygienists, 1995-1996. MSDS #: M00018515 ii. LEXOLDMON006403 Page 6 of 8 9. PHYSICAL AND CHEMICAL PROPERTIES PROPERTY Color (APHA) Physical state Stability Density (Ib/gal 25C) Specific gravity x/15.5C Distillation range (C) Acidity mg KOH/g, maximum Fire point (C) Flash point (C) Vapor pressure (mm Hg @ 100F) Viscosity (Saybolt Univ. Sec. @ 100F) (centistokes) NA--Not Available p ROPERTIES OF SELECTED AROCLORS8 1016 1221 1232 1242 1248 40 100 100 100 100 mobile oil mobile oil mobile oil mobile oil mobile oil inert 11.40 inert 9.85 inert 10.55 inert 11.50 inert 12.04 1254 100 viscous liquid inert 12.82 1260 150 sticky resin inert 13.50 1.36-1.37 x-25 323-356 1.18-1.19 x-25 275-320 1.27-1.28 x-25 290-325 1.30-1.39 x-25 325-366 1.40-1.41 x-65 340-375 1.49-1.50 x-65 365-390 1.55-1.56 x-90 ,, 385-420 .010 .014 .014 .015 .010 .010 .014 none to boiling point 170 NA 176 141-150 NA 238 152-154 0.005 none to boiling point 176-180 0.001 none to boiling point 193-196 0.00037 none to boiling point none 0.00006 none to boiling point none NA 71-81 13-16 38-41 3.6-4.6 44-51 5.5-7.7 82-92 16-19 185-240 42-52 1800-2500 -- 390-540 NOTE: These physical data are typical values based on material tested but may vary from sample to sample. Typical values should not be construed as a guaranteed analysis of any specific lot or as specifications for the product. 10. STABILITY AND REACTIVITY Stability: PCBs are very stable, fire-resistant compounds. Materials to Avoid: None Hazardous Decomposition Products: PCBs may decompose to form CO, C02, HCI, phenolics, aldehydes, and other toxic combustion products under severe conditions such as exposure to flame or hot surface. Hazardous Polymerization: Does not occur. 11. TOXICOLOGICAL INFORMATION Data from laboratory studies conducted by Monsanto and from the available scientific literature are summarized below. Single exposure (acute) studies indicate: Oral - Slightly Toxic (Rat LD50 - 8.65 g/kg for 42% chlorinated; 11.9 g/kg for 54% chlorinated) MSDS #: M00018515 LEXOLDMONOQ6404 Page 7 of 8 The liquid products and their vapors are moderately irritating to eye tissues. Animal experiments of varying duration and at different air concentrations show that for similar exposure conditions, the 54% chlorinated material produces more liver injury than the 42% chlorinated material. There are literature reports that PCBs can impair reproductive functions in monkeys. The National Cancer Institute (NCI) performed a study in 1977 using Aroclor 1254 with both sexes of rats. NCI stated that the PCB, Aroclor 1254, was not carcinogenic under the conditions of their bioassay. There is sufficient evidence in the scientific literature to conclude that Aroclor 1260 can cause liver cancer when fed to rodents at high doses. Similar experiments with less chlorinated PCB products have produced negative or equivocal results. The consistent finding in animal studies is that PCBs produce liver injury following prolonged and repeated exposure by any route, if the exposure is of sufficient degree and duration. Liver injury is produced first, and by exposures that are less than those reported to cause cancer in rodents. Therefore, exposure by all routes should be kept sufficiently low to prevent liver injury. Numerous epidemiological studies of humans, both occupationally exposed and nonworker environmentally exposed population, have not demonstrated any causal relationship between PCB exposure and chronic human illnesses such as cancer or neurological or cardiovascular effects. PCBs at high dosage can cause skin symptoms; however, these subside upon removal of the exposure source. PCBs have been listed in the International Agency for Research on Cancer (IARC) Monographs (1987)-Group 2A and in the National Toxicology Program (NTP) Seventh Annual Report on Carcinogens. 12. ECOLOGICAL INFORMATION Care should be taken to prevent entry of PCBs into the environment through spills, leakage, use, vaporization or disposal of liquid or solids. PCBs can accumulate in the environment and can adversely affect some animals and aquatic life. In general, PCBs have low solubility in water, are strongly bound to soils and sediments, and are slowly degraded by natural processes in the environment. 13. DISPOSAL CONSIDERATIONS The disposal of PCB items or equipment (those containing 50 ppm or greater PCBs) and PCB wastes is strictly regulated by 40 CFR Part 761. For example, all wastes and residues containing PCBs (wiping cloths, absorbent material, used disposable protective gloves and clothing, etc.) should be collected, placed in proper containers, marked and disposed of in the manner prescribed by EPA regulations (40 CFR Part 761) and applicable state and local regulations. 14. TRANSPORT INFORMATION The data provided in this section are for information only. Please apply the appropriate regulations to properly classify a shipment for transportation. DOT Classification: DOT Label: DOT Label: DOT Reportable Quantity: IMO Classification: IATA/ICAO Classification: IF WEIGHT OF PCBs TO BE SHIPPED IS OVER ONE POUND, THE FOLLOWING CLASSIFICATION AND LABEL APPLY. LIQUID: Environmentally Hazardous Substance, liquid, n.o.s. (Contains PCB), 9, UN 3082, III SOLID: Environmentally Hazardous Substance, solid, n.o.s. (Contains PCB), 9, UN 3077, III Class: 9 One Pound Polychlorinated Biphenyls, IMO Class 9, UN 2315, II IMO Page 9034, EMS 6.1-02 Polychlorinated Biphenyls, 9, UN2315, II MSDS #: M00018515 LEXOLDMON006405 Page 8 of 8 15. REGULATORY INFORMATION For regulatory purposes, under the Toxic Substances Control Act, the term "PCBs" refers to a chemical substance limited to the biphenyl molecule that has been chlorinated to varying degrees or any combination of substances which contain such a substance (40 CFR Part 761). TSCA Inventory: not listed. Hazard Categories Under Criteria of SARA Title III Rules (40 CFR Part 370): Immediate, Delayed. SARA Section 313 Toxic Chemical(s): Listed-1993 (De Minimis concentration 0.1%.) Reportable Quantity (RQ) under DOT (49 CFR) and CERCLA Regulations: 1 lb. (polychlorinated biphenyls) PCBs. Release of more than 1 (one) pound of PCBs to the environment requires notification to the National Response Center (800-424-8802 or 202-426-2675). Various state and local regulations may require immediate reporting of PCB spills and may also define spill cleanup levels. Consult your attorney or appropriate regulatory officials for information relating to spill reporting and spill cleanup. 16. OTHER INFORMATION Reason for revision: Conversion to the 16 section format. Supersedes MSDS dated 10/88. Therminol, Aroclor and Pydraul are registered trademarks of Monsanto Company Pyranol is a registered trademark of General Electric Company Inerteen is a registered trademark of Westinghouse Electric Corporation FOR ADDITIONAL NONEMERGENCY INFORMATION, CONTACT: Gary W. Mappes Manager, Product & Environmental Safety Robert G. Kaley, II Director, Environmental Affairs Monsanto Company 800 North Lindbergh Boulevard St. Louis, MO 63167 (314) 694-3344 Although the information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed to be correct as of the date hereof, Monsanto Company makes no representations as to the completeness or accuracy thereof, information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. In no event will Monsanto Company be responsible for damages of any nature whatsoever resulting from the use of or reliance upon Information. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS. -J LEXOLDMONOQ6406