Document Jr0RKMyqNZZNd8g0Kn9J4Bp7X

Moiisiiito^, ... rw.^inMi R. V. Sharp - Purchasing, Texas City PER YExtTfoin 0 ,J*... -.rU. TO April 26 1985 \ Second Quarterly Safety and Housekeeping Inspection - Depts. 48 & 56 V. Fields 56D J. T. Shipley 56D V-iF-''' ' - > R.D. Coleman H. M. Lacy Jake Llnkey J. D. McPhall R. E. Hears 6HAC* PLAINTIFF'S EXHIBIT The overall condition of the units was good. General Comments 1. Formal procedure for "bypassing protective devices" In place and working. 2. AVIP's - four (4) delinquent, but are scheduled. Variance letter for approval has been issued. 3. Plectron working O.K. 4. Employee knowledge of hazardous material handling satisfactory. Department 48 Safety 1. Oil load rack - drum of lubricant not grounded. 2. Full drum of Ispropyl Alcohol - half-on, half-off pallet at oil load rack. 3. Steam line (3/4") just east of oil load rack - needs insulation. 4. Cylinders next to 48X407 - safety chain is partially wired. 5. Hoses next to 48T407 need inspection. 6. Elevator with pallet and barrel at first level without safety chains hooked. Housekeeping 1. Hinge broken on 5 minute escape mask cabinet - 2nd level Oxo. distilla tion. 2. Insulation wire hanging on sight glass north of 48E501. 3. Sheet metal on ground in northeast corner of fin fans. J SC 000279 LAM001476 Department 56 - y Safcr 'IsAf - '; -er- .'. . "'-- 1. Scaffold west of 56V1-1 with no toe board. ;N- J.- *- -- --'iy--* *--'- ... ... ' v"? j v -*:'.'"rig*? ' ` "tr**: 2. Hoses not Inspected properly (next to S6T3-3 & S6T3-1). 3. Two drums not grounded In liquid waste drum area. Housekeeping 1. Sample catcher with rope on 2nd floor on top of of T3-3. 2. Liquid waste drum area - nasty looking, needs clean-up. 3. Maintenance shack (Dept. 56) - sad state of repair (drums outside - rusted out - very poor condition). 4. Plugged drain west of 56E10-1 & 2. 5. Steam hose on ground south of 56P18. 6. Clutter on 1st level of 56 - on west side boards and rope with chain. Please respond in writing to Doug Barfoot and Jim McPhall by May 17, 1985. RVS:wy LA/V7007477 SC 000280 Date Inspector SAFETY PERSONAL KNOWLEDGE OF - Assembly Points Nearest Shower/Eyebath/Extinguisher Main Disconnects/Shutoffs Safety Procedures Safety Log Book Emergency S/D Action Required Area Chemical Hazards Safety Meetings/Review of P-Bulletins Out-of-Date Fire Permits PERSONAL SAFETY EQUIPMENT Safety Glasses/Goggles Hard Hats Acid Hoods/Face Shields Scott Air Packs Vapor Proof Suits Breathing Air Respirators/Hoses Chemical/Dust Respirators ' Shoes/Boots Hearing Protection CONDITION OF SAFETY EQUIPMENT Safety Showers/Eyebaths Breathing Air Manifolds Fire Extinguishers Deluge Systems Safety Signs Car Seals on-RV Valves Safety Chains on Chain Operated Valves Bypassing of Protective Devices Safety Check Sheet RV's 0/S Devices GOOD _____ _____ _____ _____ _____ _____ .____ _____ POOR _____ _____ _____ _____ _____ _____ _____ _____ COMMENTS __________ __________ __________ __________ __________ __________ __________ SC 000281 LAM001478 Safety/Housekeeping Check List (Cont'd.) Page 2 SAFETY HAZARDS GOOD Hissing Handralls/Toeboards Wet/Slippery Floors Unchained Gas Cylinders Ladders Hoses--Utility/Chemical Blocked Safety Equipment Unguarded Rotating Equipment Spliced Electrical Cord(s) Uneven Surfaces Use of Barricade Tape Scaffolds Lab/Office Storage of Hazardous Materials Hose Utilization Training - Control of Crowsfeet or Thor Fittings on Process Condition of Utility Stations Lockout of Rotating Equipment AVIP _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ HOUSEKEEPING UNITS Control Room Behind/Inside Panels Kitchen Offices Traffic Areas Smoke/Break Areas Lab (if applicable) Unit Shop Process Area Storage Areas Cooling Towers Storage Cabinets CRAFT/SHOP Eating Area Offices Work Area Storage Cabinets/Areas Smoke/Break Areas COMMENTS - OTHER POOR _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ ------- COMMENTS SC 000282 LAM001479