CHAPTER 19
r ' 1953 Guide
/' i
Table 1.1 First Story .Warm-Air Ducts"
.".-i.j
.. Combination
** -No.
Leader Pipe-' Diameter, In'.
Register Sixe, In.. ;
- ` '*Floor: * '
Size
f
Baseboard Extension . - ; Throat Size"'
i 8 8 x 10 2 9 9 x 12 3 ,-r , : , 10- - . r,10 x 124 ` 12" 12 x 14
5 14 14 x 16
10 x 8 12 x 8 12 x 9- . . 13 x 11
2A m
3K
5A
6A x 10 6M x 12 , nA x 12 9A X 13
; a When the calculations indicate a requirement for a given room'greater thn Combination No. 4, two or more smaller units totalling the'requirea, capacity are recommended.
Table 2. . Second, Story Warm-Air Ducts--Single Wall Stacks and Fittings
Combi
nation
No.
- Leader
Pipe
In- Diameter,
Stack**- V
Size
. -In. -
Floor'
Register Size, In;
Baseboard.
' Size
Extension;
Sidewall
ii .8 12 9 14 10 15 . 12
16 ,. 12 ,
10 x 3A 12 x 3J4
14 x 3A ' 12 x 5J4 14-x 534
8x10 9 x 12 10 x 14
10 x 8 12 x 8 13 x 11
12 x 9 13 x 11
2A ,
2H 2A
3sAll
10x8 . 12 x 8
-b Recommended stack sizes. Tables may also be applied.to'3 in. and 3 1/2 in. stack depths.
Table 3. Second Story Warm-Air Ducts--Double Wall Stacks and Fittings-
Combi
nation
No.
- Leader :1 Pipe
Diameter, In.
Sr^ck Size, In.
Internal
External
Floor
Register Size, In.
Baseboard Size Extension
Sidewall
21 . 8 ' 234' x 10 334 x 10A 8 x 10
.22 8 3 . x 10. 3A x 10% 8 x 10 23 9 234" x 12 SA' x 12% 9 x 12 24 9 3 x 12 3% X 12% 9 x 12
c Commercial sixes vary l/8 in. from values shown;
10 X 8 10 x 8 12 x 8 , 12x8 ,
2A
2A
2A . 2A
10 x 8 10 x 8 12 x 8 12x8
all correlated. Similarly in. the case of return ducts, the selection specifies a complete unit consisting of return grille, return: duct, and shoe connection:
Recommended Standard Sizes
-. For the purpose of simplification and standardization, selected combina tions of comm'ercial sizes of warm air pipes, return air pipes, ducts, grilles, fittings, and' registers are designated as Combination Numbers. The numbers assigned and the combinations selected as standard are listed in the following Tables 1 to 4'inclusive.3
The selected types of boots are shown in Fig. 2, and their resistances ex
pressed: in equivalent elbows are shown in Table 5. It is, esseiitial that
free areas be maintained-.thrbughout fittings. !'
'1
Figs. 3 and,"4 show recommended practice as given in Manual 5 of the.
Gravity'Warm Air Systems
;: : '
453
Table 4'. Return Air' Doors
Combi
nation
No.
Duct Dia.
In.
Duct Area Sq.- In.
Area at
Shoe Con
nection,
. -Sq. In. ,
Metal Grille-Sizes
Choose One AB C
Base
board Intake fob First
Stobt
- When Joist '
-Lining. ,l8,USBDd
. v -*
When
Duct
Is Used
No:;of' Min.e Joists Depth Choose One
Lined In.
31 10 78
32 12 113
33 14 154 . 170
34 16 201
220
35 ' 18
254
280
36 20 '314
340
37 22 380
420
38 24" 452 -
500
8x 14 10 x 12 ;
V 1.
7
14 x 6 12 x 8
6x30 8x24 12 x 14 14 x 10
1
4-In. Ext. or 2
9
5
12 x 6 16 x 8
8x30 10 x 24 14x18
1 or 2
12 6
28 x 6 22 x - 8
10x30 12x24
30 x 10 .
1
'4^In. Ext. - or 2
16 8
28 x 8 22 x 10
12 x 30 14x24
2 10
.36 x 8 28 x 10
14 x 30. 18x24
2 .12.5
36 x 10 30 x 12
18x30
2 . 15.0
42 x 10
36 x 12
20 x 30
; \ 2.: ..,18.0 ' `42 x 12 36 x 14
d Based on 14 in. space between joists.
.. -
Use full depth of joist except when joist depth is less than minimum depth required, when pan mvet be
NWAH.& ACA. For construction, design features, and ratings of gravity furnaces see Chapter 16.
Carrying Capacity