Document JdyQV3kprLnxEBz7K95ZvRMv

452 CHAPTER 19 r ' 1953 Guide /' i Table 1.1 First Story .Warm-Air Ducts" .".-i.j .. Combination ** -No. Leader Pipe-' Diameter, In'. Register Sixe, In.. ; - ` '*Floor: * ' Size f Baseboard Extension . - ; Throat Size"' i 8 8 x 10 2 9 9 x 12 3 ,-r , : , 10- - . r,10 x 124 ` 12" 12 x 14 5 14 14 x 16 10 x 8 12 x 8 12 x 9- . . 13 x 11 2A m 3K 5A 6A x 10 6M x 12 , nA x 12 9A X 13 ; a When the calculations indicate a requirement for a given room'greater thn Combination No. 4, two or more smaller units totalling the'requirea, capacity are recommended. Table 2. . Second, Story Warm-Air Ducts--Single Wall Stacks and Fittings Combi nation No. - Leader Pipe In- Diameter, Stack**- V Size . -In. - Floor' Register Size, In; Baseboard. ' Size Extension; Sidewall ii .8 12 9 14 10 15 . 12 16 ,. 12 , 10 x 3A 12 x 3J4 14 x 3A ' 12 x 5J4 14-x 534 8x10 9 x 12 10 x 14 10 x 8 12 x 8 13 x 11 12 x 9 13 x 11 2A , 2H 2A 3sAll 10x8 . 12 x 8 -b Recommended stack sizes. Tables may also be applied.to'3 in. and 3 1/2 in. stack depths. Table 3. Second Story Warm-Air Ducts--Double Wall Stacks and Fittings- Combi nation No. - Leader :1 Pipe Diameter, In. Sr^ck Size, In. Internal External Floor Register Size, In. Baseboard Size Extension Sidewall 21 . 8 ' 234' x 10 334 x 10A 8 x 10 .22 8 3 . x 10. 3A x 10% 8 x 10 23 9 234" x 12 SA' x 12% 9 x 12 24 9 3 x 12 3% X 12% 9 x 12 c Commercial sixes vary l/8 in. from values shown; 10 X 8 10 x 8 12 x 8 , 12x8 , 2A 2A 2A . 2A 10 x 8 10 x 8 12 x 8 12x8 all correlated. Similarly in. the case of return ducts, the selection specifies a complete unit consisting of return grille, return: duct, and shoe connection: Recommended Standard Sizes -. For the purpose of simplification and standardization, selected combina tions of comm'ercial sizes of warm air pipes, return air pipes, ducts, grilles, fittings, and' registers are designated as Combination Numbers. The numbers assigned and the combinations selected as standard are listed in the following Tables 1 to 4'inclusive.3 The selected types of boots are shown in Fig. 2, and their resistances ex pressed: in equivalent elbows are shown in Table 5. It is, esseiitial that free areas be maintained-.thrbughout fittings. !' '1 Figs. 3 and,"4 show recommended practice as given in Manual 5 of the. Gravity'Warm Air Systems ;: : ' 453 Table 4'. Return Air' Doors Combi nation No. Duct Dia. In. Duct Area Sq.- In. Area at Shoe Con nection, . -Sq. In. , Metal Grille-Sizes Choose One AB C Base board Intake fob First Stobt - When Joist ' -Lining. ,l8,USBDd . v -* When Duct Is Used No:;of' Min.e Joists Depth Choose One Lined In. 31 10 78 32 12 113 33 14 154 . 170 34 16 201 220 35 ' 18 254 280 36 20 '314 340 37 22 380 420 38 24" 452 - 500 8x 14 10 x 12 ; V 1. 7 14 x 6 12 x 8 6x30 8x24 12 x 14 14 x 10 1 4-In. Ext. or 2 9 5 12 x 6 16 x 8 8x30 10 x 24 14x18 1 or 2 12 6 28 x 6 22 x - 8 10x30 12x24 30 x 10 . 1 '4^In. Ext. - or 2 16 8 28 x 8 22 x 10 12 x 30 14x24 2 10 .36 x 8 28 x 10 14 x 30. 18x24 2 .12.5 36 x 10 30 x 12 18x30 2 . 15.0 42 x 10 36 x 12 20 x 30 ; \ 2.: ..,18.0 ' `42 x 12 36 x 14 d Based on 14 in. space between joists. .. - Use full depth of joist except when joist depth is less than minimum depth required, when pan mvet be NWAH.& ACA. For construction, design features, and ratings of gravity furnaces see Chapter 16. Carrying Capacity Fig. 2. Typical Warm Air-Boots