Document JRdj1pDdwVp6Zw0eEmrX3G9O
Dept. A-246 - Operating Instructions
Transformer Pyranol A-13B3B hjfo Aroclor 1260 - 55$ TTCB
To make l43000 gal. batch A-13B3B in #2 mix tank.
"
.
1 - Take 1 - l6 oz. sample of Unox Epoxide 201 for assay..
.
2 - Unload 83000 gal. car of TTCB to #2 mix tank (approx. 12'
in tank).
,
3 - Pump 1260 from #8 storage to 256" in #2 mix tank.
4 - Add 1 - bag attapulgus earth.
5 - Agitate with air and mechanical agitator and circulate by passing press for 3 hours.
6 - Circulate thru press for 1 hour and take 1 - 5 pt. bottle for check analysis - gravity - index - chlorides & moisture.
,7 - Continue, circulating thru press for 3 hours. ...
8 - Blow and clean press.
9 - Correct gravity and index (Gr. I.563 " 1.571) (Index 1.6075 -
I.6085). Mix should be on low side with above measure
ments. Gravity will be raised about .001 and index will
be raised about .0004 by the addition of 1 inch of 1260.
If gravity or index or both are high3 resample for gravity
. . and index analysis. Moisture can.be reduced by blowing
. with air. Chlorides can be reduced by additional earth
treatment.
.
10 - When all check analysis are in specs add Unox Epoxide 201.
(This must be calculated from the assay).
.
.
11 - Circulate again by passing press for 3 hours.
,
.
12 - Put thru-.; press. 1 hour and take, final samples. .3-5 pt. .
bottles.
.
.
13 - After an additional 3 hours thru press - blow and clean press.
.
ghW
''
' '
9/12/63 .
.
R. C. Smith ,
PCB-ARCH-EXT0374510