Document JNb9yZGnYOxOpQR42jQrXo1g6
ABERDEEN CHEMICAL PLANT
INDUSTRIAL HYGIENE MONTHLY REPORT
Month: April, 1985 Date of Report: May 21, 1985
I. ROUTINE CHEMICAL DOSIMETRY
All Sample Results
CHEMICAL
PEL NO. %
PEL (OVEREXPOSURES) NO. %
VCM Lead Total Particulates
80 7 2
94.4 100.0 100.0
5
0 0
5.6
0.0 0.0
Overexposures
JOB CLASS
EXPOSURE
SOURCE
General Helper
1.8 ppm, VCM
Employee overexposed while covering a vinyl reactor area sewer found producing high VCM levels during firewatch duty.
General Helper
1.1 ppm, VCM
Employee spent shift bagging PVC resin. The specific cause of his overexposure has not yet been determined.
General Mechanic
2.9 ppm, VCM
Employee overexposed while blanking out D700 reactor.
Maint. Supervisor
2.5 ppm, VCM
Employee worked in all VCM areas. The specific cause of his overexposure has not yet been determined.
General Mechanic
2.1 ppm, VCM
Employee worked in the main tenance shop and in the plasticizer tank farm while repairing a pump. The specific cause of his over exposure has not yet been determined.
* Respiratory protection was worn. ** Respiratory protection was not worn.
VAB.0001178068
Industrial Hygiene Monthly Report
II. OSHA HAZARD COMMUNICATION RULE
A proposal for compliance with the labeling requirements of the OSHA Hazard Communication Rule was prepared and given to department heads for review.
III. GILMONT PRECISION FLOWTUBE
The calibration of the Gilmont flowtube used with Bendix air pumps during lead and total particulates dosimetry work was checked. No significant drift was seen.
IV. BLEND TANK TOP AREA VCM SAMPLES
Four blend tank top area VCM samples were taken using REAL "Minimonitor" badges to determine the need for respiratory protection in the vicinity of the tops of the small V-ll blend tanks during slurry trans fer from reactors.
The two samples taken on 4/15/85 were during the transfer of 5265 slurry from 745 reactor into the 650 and 651 blend tanks. Wind at the time was from north to south at 1-5 MPH. The temperature was 60F under cloudy skies and during high humidity.
The samples taken on 4/16/85 were during the transfer of 5265 slurry from 745 reactor into the 654 and 655 blend tanks. Wind at the time was from north to south at 1-2 MPH. The temperature was 66F under
Sample duration was twenty minutes in all four cases.
The results clearly demonstrate that respiratory protection is needed in the vicinity of the small V-ll blend tanks during slurry transfer from the reactors:
Date
Sample Location
Results, ppm VCM
4/15/85
On top of 651 blend tank, 4 inches south of hatch
<0.1
4/15/85
4 feet south and above 651 blend tank hatch
13.7
4/16/85
On top of 654 blend tank, 4 inches south of hatch
19.7
4/16/85
4 feet south and above 654 blend tank hatch
12.3
Uptain
JF, JWW, DWH, PJK, WFH, CRS, VEM, RAF , AHS, CWT Tom Grumbles, J. R. Drumwright, M.D. - Houston
VAB.0001178069