Document JNJx3Y4VkG252q59ov5b7JbyZ
n" "
PROGRESS REPORT
ORGANIC CHEMICALS DIVISION *T. LOUIE RESEARCH DENT.
* *B'"'EaUaf8ky
* E. K. Emery * R. E. Keller
* W. E. Koerner
?-?2 -6 50.111 4285 March 1962
ftP04tr no. coot 1 UNCL-5
SPECIAL MSTBtfCTMMI________________________________________
i. R. A. Oelsman/J.F. Caldwell - JFQ
tJWW'. J. Gresham/R. F. Schubert - WOK V H. L. Hubbard - Res 1 . R. W. Wise - Nltro .* P. Benlgnus - 0-0-B-2-S * MCL (2) via J. p. Sticlcley-B-3-N
t.
10. 11. It
It.
14.
7* K. McHugh - Res. 2
/
It. It.
lSOP.r LHCLyPCT PCTA|l|
ANALYTICAL CHEMISTRY AND SPECTROSCOPY INVESTIGATIONS
PROBLEM
Aroclor 1242 Production Variations - Evaluation of Infrared and Gas Chromatography Methods.
SUMMARY
An infrared and OLPC (gas-liquid partition chromatography) study of five normal production samples of Aroclor 1242 from Anniston showed that most of the variations in Isomer content were small and random. However, one pronounced periodic variation was observed in the Infrared spectra in the region of 14.3-14.4 microns which was, shown by a combination of infrared and OLPC analysis to be the result.of variations in the lower chlorination level isomers, namely the 2-chloro, 2,21-dichloro and the 2.41dichlorobiphenylB.
DETAILS Yes
B. Katlafsky E. M. Emery
0*15788
HARTOLDMON0005029
3- -
DETAILS
Infrared absorption spectroscopy and GLPC (gas-liquid partition chromatography) methods were used to study com positional variations in production lots of Aroclor 1242 shipped to General Electric over the past six months. The study was initiated to determine if more than normal variations were present and, if so, what is the cause of these differences.
Reserve samples of lots D-122, D-145 and D-I85 were ob tained from Anniston to represent normal production material. Since no sample of lot D-153, the subject of a recent General Electric complaint, was available samples of lots D-152 and D-154 were substituted. Infrared spectra were run under con ditions such that the gross infrared spectra could be compared rather than under special conditions to study a particular isomer. The GLPC analysis was carried out using a 150' x 0.020" stainless steel capillary column coated with silicone gum rubber and a flame ionisation detector.
A critical comparison of the IR spectra showed primarly the minor random variations expected for small differences in isomer distribution. However, in the region of 14.3 to 14.4 microns two weak absorption bands were observed whose intensities varied periodically with lot number. The attached IR spectrum shows the superimposition of the spectra of the five lots of Aroclor 1242 studied run under conditions to amplify the difference. Examination of the spectra in the region of 14.3-14.4 microns shows that the intensity of the absorption bands at these wave lengths increases sharply from lot D-122 to D-145. The absorp tion reaches a maximum in lot D-152 then tapers off in lots D-151* and D-I85. The maximum variance observed between lots D-122 and D-152 was 30$ in terms of optical absorption units.
The GLPC data for the five samples shows the random varia tions of isomers also detected by IR. No variations in a single component was observed that could explain the difference found in the IR spectra. The GLPC data is tabulated in Table I. tfhere possible the GLPC fraction has been identified as a particular isomer on the basis of retention time.
0*15789
HARTOLDMON0005030
LCOSOOONOIAiaiOiyVH
O^STVO
-4-
Desplte the fact that the positive identification of the components Involved in the observed periodic variation in the IR spectra could not be made structural characteristics of the materials contributing to this variation could be assigned based on infrared interprepation of aromatic absorption patterns.
The chlorine distribution patterns in Aroclor 1242 fit the following general classes:
Type I
x
Type II
Type III
Type IV
Of these four general classes of chlorine distribution patterns only Types I and II (the monosubstltuted aromatics and the ortho disubstituted aromatics) produce absorption bands in the 14.3 14.4 micron region. Although it is possible to detect and dif ferentiate the Types I and II materials in other regions of the IR spectra, interferences and overlapping of bands prevents this in the bulk sample.
In order to resolve this problem and identify the components causing the observed variance in the IR spectra,lot D-152 was fractionally distilled by Mr. George Ashworth under reduced pressure and four top fractions representing a total of 8.4$ of the charge were isolated for subsequent analysis. The GLPC analytical data which was confirmed by IR analysis shows that the mono and dlchlorobiphenyls having the type I and II structures postutated by IR interprepation of the bulk sample were the major contributors to the variation observed in the IR spectra of the bulk sample. The GLPC data Is tabulated in Table II.
-5A combination of IR and GLPC analysis has demonstrated that the periodic variation observed in Aroclor 1242 lots D-122, D-145, D-152, D-154 and D-I85 are the cumulative effects of variations primarily of the 2-chloro, 2,21-dichloro and the 2,41-dichloroblphenyls.
0i,ii)791
HARTOLDMON0005032
HARTOLDMON0005033
Table I AROCLOR 1242
Fraetlon/Component Lot D-122
1 Biphenyl 2 Ortho 3) Meta 4)Para 5 2,21 6 2.5 7 (2,4 or 2,3 or
2,3*)
8 2,41
9 (3,5 or 3.31)
10 (3,4 or 2,5,2!) 11 4-4i
12 13 2,3,2*
3*0 lc)j
16) 2,5,4*
17) l8 3,4,21
19 2,3,4 20 21 22
23 24 25 26 3,4,4*
27 28 29 30 31) 32) 33
0.04 0.8 0.2
4.5 0.8
1.4
9-1 0.7 10.2
5.3 0.2 4.8
1.5
15-3
6.7 3-0 0.7 0.2 3-6
2.7 1.9 3-5 3.3 3.4 0.6 0.1 0.1 5-1
3-9
lot D-145
0.03 1.0 0.3
4.9 0.8
1.8 9-6 0.8 10.0 5-7 0.5 5-8
1.8
14.9
6.6 3.0 0.7 f ,, t3'4
2.4 1.5 3-3 3-2 3-2 0.7 0.1 0.05 4.6
3-5
Lot D-152
0.3 1-9 0.6
5.2 1.0
1.9 10.3
0.6 9.4 5-2 ' 0.3 5-1
1.5
13-7
6.0 2.7 0.6 0.2 3.4 2.4 1-7 3-3 3.1 3-1 0.6 0.1 0.05 4.9
3-7
Lot D-154
0.2 1.8 0.5
4.8 1.0
1.8 9.6 0.7 9-5 5-3 0.4 5-2
1.4
14.1
6.1 2.7 0.7 j3-9
2.6 1.8 3.4 3-0 3-3 0.6 0.1 0.05 5-1
4.0
Lot D-185
0.03 0.9 0.2
4.6 0.8
1.6 9-5 0.7 10.1 5.4 0.5 5-7 1.6
15-0
6.6 3-0 0.7 0.2 3-5 2 .6 1.8 3-3 3-2 3-4 0.8 0.1 0.1 4.9
3-8
OA lt> 793
HARTOLDMON0005034
Fraction/Component
34 35 36 37 38 39 40 41 42 43 44 48 52
Lot D-122
0.2 2-7 0.3 0.5 0.2 0.03 0.2 0.4 0.2 0.8 0.1 0.6
0.3
Table I (cont'd)
Lot Lot Lot
D-145
D-152
D-154
0.1 2.4
0.3 0.5 0.2
0.05 0.2
0.3 0.2 0.8 0.2 0.4 0.4
0.2 2.6
0.3 0.7 0.5 0.1
0.3 0.5 0-3 1.1 0.1
0.3
0-3
0.2 2.6
0.3 0.7 0.3 0.05 0.2 0.4 0.2
0.9 0.2
0.5 0.3
Lot D-185
0.2 2.6 0.3 0.5 0.2 0.02 0.2 0.3 0.1 0-7 0.1 0.4 0.2
0415794
HARTOLDMON0005035
Table II ARCOCLOR 1242 LOT P-152 TOPPING EXPERIMENT
Fraction/Component
1 Biphenyl 2 ortho 3) meta 4) para 5 2,2! 6 2,5 7(2 ,4 or 2,3 or
2.31) 8 2,4i
9 (3,5 or 3>31) 10(3,4 or 2,5,2!) 11 4,4!
32 13 2,3,2! 14)
15) 16) 2,5,4! 17) 18 3,4,2!
19 2,3,4 20 21) 22)
23 24
25 26 3,4,4!
27 28 29 30
3D 32) 33
Starting F#1 F#2 F#3_, F#4
Residue
Mat'l
1-9$ 1-7# 23#_--2--- ^1--
0.3? 1-9 0.6
5-2 1.0
8.6# 29-7
6.5
36.8 2.8
0.8# 26.0
7-3
43.0 3-4
trace 7.1#
5-9
trace 1.3# 4.1
41.3 5.6
36.0 6.6
0 0 trace
0.2 0.2
1.9 10.3
0.6 9.4
5.2 0.3 5-1
1.5
2.9 11.5
0.3
4.2 14.1
0.3
6.9 27.4
1.1
[ -8 [ 1.0
3-5 0.8
0 0 0.1 trace trace 0.3
0
9.2
35-0
1.5 4.7 1.2 0.1 0.4
0
0.9 5-7 0.5 9-9 6.6 0-5 6.1
2.1
13-7
6.0 2.7 0.6 3.6
trace trace 17.6
7-7 2.1 0.7 4-5
2.4 3.1
1.7 2.0 3-3 4.1
3.1 3-8 3.1 3.8
0.6 0.7
0.1 0.1
o.i
4.9 6.1
3-7 4.5
0415 795
HARTOLDMON0005036
Fraction/Component
34 33 36 37 38 39 40 41 42 43 44 48 62
Table II (oont'd)
Starting F#1 F#2 F#3 F#4
Residue
Material______________________________________
0.2 0.2 2.6 3-1 0.3 0.2 0-7 0.6 0.5 0.3 0.1 trace
0.3 0.3 0.5 0.4 0.3 0.2 l.l 1.0 0.1 0.1
0.3 0.5 0.3 *
* Instrument shut down before this peak was eluted from the column.
0415796
HARTOLDMON0005037