Document JNBk8p1NzKVQ8ev5v8YN4DYqa
Air Conditioning lS5rf,I"1
Campbell Heating Company
3121 Dean Ave., Des Moines, Iowa DIRECT FIRED SPACE HEATERS
Oil, Gas. Stoker, Hand Fired or Combination Gas and Oil Fired
Heater Guaranteed for 10 Years from Any Cause, Blower, Motor, Burner and Controls, for One Year Against
Defects.
The Campbell Dir ect Fired Space Heat ers are designed to be located in the room to be heated but they can be connected to a duct system for heating' any type of building and are quiet enough to be used in churches,
schools, etc
They are designed to be shipped as a com plete unit ready to connect to fuel line, electric power and flue
but they can be ship ped in sections for as sembling in a base ment room. The steel heater is then assem bled and welded on
the job. Furnished also for Gas, Stoker or Hand Firing
Unit Num
ber
Btu (1). Output Capacity
70* Return Air-- No Ducts
Blower Motor CFM HP
(2) (3)
Heat ing
Surface Sq. Ft.
Overall Dimensions
inches Not ind.
burner
W L Ht.
Firing Rates
Stack
Connection
Dis. In.
(4)
Oil GPH
1000 Btu GAS C.F.H.
8toker L b s /H r
Approx. Ship ping Weight
725,000 8.850 2 -i HP 280 75 80 114 893,000 10,900 2 4 HP 320 75 93 118 1,080,000 13,200 2 -! HP 360 75 105 120 1,275,000 15,600 2 -1 HP 440 75 118 120
17,500 2 -1 HP 480 75 130 120 1,725(000 21,100 2 -1 HP 600 94 137 136 U8250 2,160,000 26,400 2-1JHP 750 94 157 136
12 14 16 16 18 20 20
7.0 8.5 10.5 12.0 14.0 16.5 20.5 1
900 1,120 1,350 1,600 1,800 2,150 2,700
80 5,000 100 6.0UU 125 l, uw -
150 10,000
200 11,UUU 13, UW
(1) Heat Emission per square foot of heating surface is 3000 Btu per hour or less. If heater is hot. located in room to be heated an allowance for radiation losses
snouia ue inauu.
..
(2) Rated air volume produces 75 deg air temperature rise through the heater, ims
air volume can be varied to suit other conditions.
(3) Motor size can be increased to provide for any duct system.
''
(4) An induced draft blower can be furnished if a stack or chimney is not available.
The gas passages of the heater are adequate so that an induced draft blower is
not ordiuarily necessary.
_ - For data on other Campbell Products tee pages 10SS-108S.
Eastern Representative: . Neil Adams, Old York Road, Lambeetville, N. J., Telephone No. 665
1094
Air Conditioning
E. K. Campbell Company
Kansas City 3, Missouri HEAVY DUTY FURNACE FAN EQUIPMENT
Standard Units Up To 8,000,000 BTU/HR.
hSum
Made in Units from 500,000 Btu/hr to 8,000,000 Btu/hr. Available for any fuel or in "All-Fuels" model. Operating efficiencies up to 84 per cent with resultant fuel
economy. Counter-Flow heat transfer. Drive thru principle exclusively (no suction applications). . Low Internal resistance to flue gases. - Fiberglas insulated casing. Baked enamel exterior finish. Extra Heavy welded steel construction throughout. Available in any required arrangement of duct outlets. Extreme flexibility of equipment arrangements. Balanced job design--blower and furnace sized separately. Sold only on an engineered basis to fit job requirements.
Used in thousands of large buildings over country, the E. K. Campbell Co*s Type H-D Furnace-Fan system is particularly suited for buildings containing large spaces, such as industrial plants, churches, schools, hangars, etc. High quality equipment, designed to last, giving unusually low cost on a year service basis.
The E. K. Campbell Company guarantees RESULTS as well as its equipment. Inquiries invited regarding LARGE SPACE HEATING PROBLEMS.
Manufacturing Engineers since 1910
1095
s'