Document JN9L0OGNNwDrDVd1B4rjb9kja

^Lancaster Laboratories ^ d'v>sin f Thermo Analytical Inc LLI Sample No. TL 2795998 Collected: W 3/97 at 13:45 by SN Submitted: 10/ 3/97 Reported: 10/24/97 Discard: 11/24/97 CWK-BD-49 Soil Sample TCLP MOM-VOLATILE EXTRACTION Chambers Works Soil Reuse Job #6015-08-06 Account No: 07032 DERS/DuPont Env Reined Services Barley Hill Plaza, Bldg. 27 Routes 141 & 48 Wilmington DE 19805 P.0. LBIO-62248 Rel. L146 SAMPLE MDL SAMPLE UNITS BLANK DUP RPD MS MSD MS LCS LCS LCS LIMITS RPD LCS DUP RPD LOW HIGH Tphenyldl4 Phenol-d6 2-FI phenol 2,4,6-TBP 81 40 60 83 33 141 10 94 21 100 10 123 CAT NO 1335 1336 1746 1749 1751 1755 1766 5705 0259 5713 0949 4731 0947 ANALYSIS NAME Arsenic Selenium Barium Cadmium Chromium Lead Silver WW/TL SW 846 ICP Digest (tot) Mercury WW SW846 Hg Digest TCLP Acid Base/Neutrals TCLP Leachate Extraction TCLP Non-volatile Extraction METHOD SW-846 6O10A SW-846 6010A SW-846 6010A SW-846 6010A SW-846 6010A SW-846 6010A SW-846 6O10A SW-846 3010A SW-846 7470A SW-846 7470A SW-846 8270B SW-846 3510B SW-846 1311 LABORATORY CHRONICLE TRIAL 1 1 1 1 1 1 1 1 1 I 1 1 1 ANALYSIS DATE AND TIME 10/14/97 1350 10/14/97 1350 10/16/97 0557 10/16/97 0557 10/16/97 0557 10/22/97 1753 10/14/97 1350 10/09/97 1330 10/10/97 1755 0000 10/15/97 2347 10/09/97 0300 10/07/97 1420 ANALYST Nina C. Haller Nina C. Haller Donna R. Sackett Donna R. Sackett Donna R. Sackett Jane B. Follweiler Nina C. Haller Christine M. Conlin Nelli S. Markaryan Nelli S. Markaryan Linda M. Hartenstine David M. Yiannokos Melissa M. Stuck State of New Jersey Lab Certification No. 77011 Questions? Contact your Client Services Representative Nancy Bornholm at (717) 656-2300 jflA4tV\ ACIL Lancaster Laboratories 2425 New Holland Pike PO Sox 12425 Lancaster, PA 176Q5-2425 717-656-2300 Fax: 717-656-2681 Respectfully Submitted Ramona V. Layman Manager, Metals/Leachates See reverse side for explanation of symbols and abbreviations 2216 Rev. 8/4/97 DUP050464926 Explanation of Symbols and Abbreviations The following defines common symbols and abbreviations used in reporting technical data: N.D. TNTC IU umhos/cm C i : meq S ug mi m3 none detected Too Numerous To Count international Units micromhos/cm degrees Celsius (diet) calories miiliequivalents gram(s) microgram(s) miiliiiter(s) cubic meterts) BMQL MPN CP Units MTU lb, kg mq 1 u) fib >3 urn/rr.1 Below Minimum Quantitation Level Most Probable Number cobalt-chloroplatinate units nephelometric turbidity units degrees Fahrenheit pound(s) kilogram(s) milligram(s) liter(s) microhter(s) fibers greater than 5 microns in length per mi < > ppm ppb Dry weight basis less than - The number following the sign is the limit of ouant'tation, the smallest amount of analyte which can be reliably determined using this specific: test. greater than parts per tr,alien - One ppm is equivalent to one milligram per kilogram < mg/kg), or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mo/l), because one liter of water has a weight, very close to a kilogram. For gases or vapors, one ppm is equivalent ic one microliter o* gas per liter of gas. parts per billion Results printed under tins heading have been adjusted for moisture content. Tb s increases tire analyte weight concentmtior- to approximate die value present in a similar sample without mootme. U.S. EPA data qualifiers: Organic Qualifiers A B C 0 fc J N P U X,Y,Z TIC is a possible aidoi-condensation product Analyte was also detected in the blank Pesticide result confirmed by GC/MS Compound quantitated on a diluted sample Concvnrrauor exceeds the calibration range of the instrument Estimated value Presumptive evidence of a compound (TICs only) Concentration difference between primary and confirmation columns >25% Compound was not detected Defined in case narrative inorganic Qualifiers 8 Value is <CRDL, bur >IDL Estimated due to interference M Duplic.au: inject on p-eovon no: met N Spike sample not within contro- emits S Method of standard audit sens (MSA1 ;.;:>ec for cfl:asAtion U Compound was no': detected W Post digestion spike out of c:onrrc' limits * Duplicate analyse not within control limits + Correction coefficient tor MSA <0 995 Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory. WARRANTY AND LIMITS OF LIABILITY - in accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE FOP. INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF LANCASTER LABORATORIES AND (B) WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF- fHI: POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client. DUP050464927