Document JN9L0OGNNwDrDVd1B4rjb9kja
^Lancaster Laboratories ^ d'v>sin f Thermo Analytical Inc
LLI Sample No. TL 2795998
Collected: W 3/97 at 13:45 by SN
Submitted: 10/ 3/97 Reported: 10/24/97 Discard: 11/24/97
CWK-BD-49 Soil Sample TCLP MOM-VOLATILE EXTRACTION Chambers Works Soil Reuse
Job #6015-08-06
Account No: 07032 DERS/DuPont Env Reined Services Barley Hill Plaza, Bldg. 27 Routes 141 & 48 Wilmington DE 19805
P.0. LBIO-62248 Rel. L146
SAMPLE MDL
SAMPLE UNITS
BLANK
DUP RPD MS MSD
MS LCS LCS LCS LIMITS RPD LCS DUP RPD LOW HIGH
Tphenyldl4 Phenol-d6 2-FI phenol 2,4,6-TBP
81 40 60 83
33 141
10 94 21 100 10 123
CAT NO 1335 1336 1746 1749 1751
1755 1766
5705 0259
5713 0949
4731 0947
ANALYSIS NAME Arsenic Selenium Barium Cadmium Chromium
Lead Silver
WW/TL SW 846 ICP Digest (tot) Mercury
WW SW846 Hg Digest TCLP Acid Base/Neutrals
TCLP Leachate Extraction TCLP Non-volatile Extraction
METHOD SW-846 6O10A SW-846 6010A SW-846 6010A SW-846 6010A SW-846 6010A SW-846 6010A SW-846 6O10A
SW-846 3010A SW-846 7470A
SW-846 7470A SW-846 8270B
SW-846 3510B SW-846 1311
LABORATORY CHRONICLE
TRIAL 1 1 1 1 1 1 1 1 1 I 1 1 1
ANALYSIS DATE AND TIME 10/14/97 1350 10/14/97 1350 10/16/97 0557 10/16/97 0557 10/16/97 0557 10/22/97 1753 10/14/97 1350
10/09/97 1330 10/10/97 1755
0000
10/15/97 2347
10/09/97 0300 10/07/97 1420
ANALYST Nina C. Haller Nina C. Haller Donna R. Sackett Donna R. Sackett Donna R. Sackett Jane B. Follweiler Nina C. Haller
Christine M. Conlin Nelli S. Markaryan
Nelli S. Markaryan Linda M. Hartenstine
David M. Yiannokos Melissa M. Stuck
State of New Jersey Lab Certification No. 77011
Questions? Contact your Client Services Representative
Nancy Bornholm
at (717) 656-2300
jflA4tV\
ACIL
Lancaster Laboratories 2425 New Holland Pike PO Sox 12425 Lancaster, PA 176Q5-2425 717-656-2300 Fax: 717-656-2681
Respectfully Submitted Ramona V. Layman Manager, Metals/Leachates
See reverse side for explanation of symbols and abbreviations
2216 Rev. 8/4/97
DUP050464926
Explanation of Symbols and Abbreviations
The following defines common symbols and abbreviations used in reporting technical data:
N.D.
TNTC
IU
umhos/cm
C
i
:
meq S
ug
mi
m3
none detected Too Numerous To Count international Units micromhos/cm degrees Celsius (diet) calories
miiliequivalents gram(s) microgram(s) miiliiiter(s) cubic meterts)
BMQL MPN
CP Units MTU
lb, kg
mq 1
u) fib >3 urn/rr.1
Below Minimum Quantitation Level Most Probable Number cobalt-chloroplatinate units nephelometric turbidity units degrees Fahrenheit pound(s) kilogram(s) milligram(s)
liter(s) microhter(s) fibers greater than 5 microns in length per mi
<
>
ppm
ppb Dry weight
basis
less than - The number following the sign is the limit of ouant'tation, the smallest amount of analyte which can be reliably determined using this specific: test.
greater than
parts per tr,alien - One ppm is equivalent to one milligram per kilogram < mg/kg), or one gram per million grams. For aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mo/l), because one liter of water has a weight, very close to a kilogram. For gases or vapors, one ppm is equivalent ic one microliter o* gas per liter of gas.
parts per billion
Results printed under tins heading have been adjusted for moisture content. Tb s increases tire analyte weight concentmtior- to approximate die value present in a similar sample without mootme.
U.S. EPA data qualifiers:
Organic Qualifiers
A B C 0 fc
J N P
U X,Y,Z
TIC is a possible aidoi-condensation product
Analyte was also detected in the blank Pesticide result confirmed by GC/MS Compound quantitated on a diluted sample Concvnrrauor exceeds the calibration range of the instrument Estimated value Presumptive evidence of a compound (TICs only) Concentration difference between primary and confirmation columns >25% Compound was not detected Defined in case narrative
inorganic Qualifiers
8 Value is <CRDL, bur >IDL Estimated due to interference M Duplic.au: inject on p-eovon no: met N Spike sample not within contro- emits S Method of standard audit sens (MSA1 ;.;:>ec
for cfl:asAtion U Compound was no': detected W Post digestion spike out of c:onrrc' limits * Duplicate analyse not within control limits + Correction coefficient tor MSA <0 995
Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our staff. This report shall not be reproduced except in full, without the written approval of the laboratory.
WARRANTY AND LIMITS OF LIABILITY - in accepting analytical work, we warrant the accuracy of test results for the sample as submitted. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE FOP. INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF LANCASTER LABORATORIES AND (B) WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF- fHI: POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client.
DUP050464927