Document JMkmNVoor631BNv230w8p7YO
DATE: PROJECT:
INDUSTRIAL HYGIENE MONITORING June 30, 1987
Monitor insulators for asbestos exposure while patching exposed insulation on T-3 methyl chloride tank in Monomers.
UC-3063
DATE OF SAMPLES:
3/26/87
SAMPLE
Z-9132 Z-9133 Z-9134
TYPE
BZ BZ BZ
TIME START STOP
MIN.
10:27 11:24 10:30 11:24 10:28 11:24
57 54 56
FLOW RATE (cc/min)
4000 4000 4000
VOLUME (liters)
CONC.
PEL TWA8
228 <0.0022 f/cc 0.20 f/cc
216
0.03 f/cc
0.20 f/cc
224
<0.02 f/cc
0.20 f/cc
RESP.
A A A
RECOMMENDATIONS:
Share this information with the insulators
DISCUSSION:
All samples were well below the PEL during the sample period.
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO:
Microscopy
C. R. McMillan/T. L. Grittie
JHM Labs D. G. Beddow,^6^ A. Boggs, A. A. Cosper, E. L. Doerflein, J. J. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Sumners, G. W. Wulfert.
TLG/le 5610A
UCC 002053
DATE: PROJECT:
DATE OF SAMPLES: SUMMARY:
SAMPLE
Z-9050 Z-9051 Z-9052
TYPE
BZ BZ BZ
INDUSTRIAL HYGIENE RESULTS
June 30, 1987.
Monitor insulators for asbestos exposure while removing insulation from Emulsion Building, Polymers II.
2/15/87 and 2/17/87
DATE
2/15 2/15 2/17
TIME START
13:15 13:17 10:30
TIME STOP
14:20 14:20 11:30
MINUTES
65 63 60
RESULTS
COMMENTS
<0.02 f/cc 0.09 f/cc 0.68 f/cc
Glove Bag Glove Bag Inside negative pressure enclosure
BZ =* breathing zone DISCUSSION:
RECOMMENDATIONS:
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO:
All insulators monitored wore airline respirators. As one can see from the above data, the use of glove bags where feasible, significantly reduces personnel exposure and should be the engineering control of choice if possible. Sample Z-9052 shows a fiber concentration above the PEL, TWAg of 0.2 f/cc during the sampling period. This concentration is, however, well below the limitations of the respirator.
Use glove bags whereever feasible. Regardless of the method of choice, the material must be thoroughly wetted to minimize fibers in the air. Share this information with insulators.
Microscopy
C. R. McMillan/T. L. Grittie
JHM Labs
t'"D. A. Boggs, E. L. Doerflein, J. K. Kyle, D. L. Mullins, K. B. Purinton, W. V. Summers, G. W. Wulfert.
TLG/le 5601A
UCC 002054