Document JMkmNVoor631BNv230w8p7YO

DATE: PROJECT: INDUSTRIAL HYGIENE MONITORING June 30, 1987 Monitor insulators for asbestos exposure while patching exposed insulation on T-3 methyl chloride tank in Monomers. UC-3063 DATE OF SAMPLES: 3/26/87 SAMPLE Z-9132 Z-9133 Z-9134 TYPE BZ BZ BZ TIME START STOP MIN. 10:27 11:24 10:30 11:24 10:28 11:24 57 54 56 FLOW RATE (cc/min) 4000 4000 4000 VOLUME (liters) CONC. PEL TWA8 228 <0.0022 f/cc 0.20 f/cc 216 0.03 f/cc 0.20 f/cc 224 <0.02 f/cc 0.20 f/cc RESP. A A A RECOMMENDATIONS: Share this information with the insulators DISCUSSION: All samples were well below the PEL during the sample period. METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. G. Beddow,^6^ A. Boggs, A. A. Cosper, E. L. Doerflein, J. J. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Sumners, G. W. Wulfert. TLG/le 5610A UCC 002053 DATE: PROJECT: DATE OF SAMPLES: SUMMARY: SAMPLE Z-9050 Z-9051 Z-9052 TYPE BZ BZ BZ INDUSTRIAL HYGIENE RESULTS June 30, 1987. Monitor insulators for asbestos exposure while removing insulation from Emulsion Building, Polymers II. 2/15/87 and 2/17/87 DATE 2/15 2/15 2/17 TIME START 13:15 13:17 10:30 TIME STOP 14:20 14:20 11:30 MINUTES 65 63 60 RESULTS COMMENTS <0.02 f/cc 0.09 f/cc 0.68 f/cc Glove Bag Glove Bag Inside negative pressure enclosure BZ =* breathing zone DISCUSSION: RECOMMENDATIONS: METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: All insulators monitored wore airline respirators. As one can see from the above data, the use of glove bags where feasible, significantly reduces personnel exposure and should be the engineering control of choice if possible. Sample Z-9052 shows a fiber concentration above the PEL, TWAg of 0.2 f/cc during the sampling period. This concentration is, however, well below the limitations of the respirator. Use glove bags whereever feasible. Regardless of the method of choice, the material must be thoroughly wetted to minimize fibers in the air. Share this information with insulators. Microscopy C. R. McMillan/T. L. Grittie JHM Labs t'"D. A. Boggs, E. L. Doerflein, J. K. Kyle, D. L. Mullins, K. B. Purinton, W. V. Summers, G. W. Wulfert. TLG/le 5601A UCC 002054