American Society of Heating and Ventilating Engineers Guide, 10. Design the air distribution system and the air outlets and inlets. 19 and 20.) 11. Calculate the total static pressure of the system. 12. Select the fan, motor, and drive. (See Chapter 17.) .. 13. Select the pump and motor. 14. Design the control system. (See Chapter 14.) (See Cha,^ ^ f | j .* ZONING The above general outline of procedure will prove satisfactory f0r ^ smaller and less complex installations. However, when dealing .with air conditioning systems for large buildings, after a proper analysis has b, made of .the conditions to be maintained and the heat loads encountered it is generally considered best practiCe to-divide the^compiete job intot Motor Fig. 3. Central Dehumidifying Plant and Local Recirculating Fans number of suitably sized units. In some cases a unit per floor or group! floors may complete the design satisfactorily, whereas in others it maybt advantageous to have separate units for each of the various outside^ exposures of the building. Where the floor area is large in relation to the outside wall exposure, it is obvious that provision must be made for tk, variable load to which the outside exposures are subjected. The hear loads on inside rooms are apt to be less variable since the fluctuations! the outside weather conditions are not directly involved.. Such condition, often result in the natural zoning or segregation of rooms having similai exposures and internal heat loads. | LOCATION OF APPARATUS | Availability of space for apparatus and duct work is of primary i portance when selecting the type of system for a given design. In gener^ for large installations, the refrigeration equipment, because of its s'" 158 Central.Air Conditioning Systems d operating characteristics, is located in the basement along weighs a/\ j|erSi fjre pumps, and other equipment. The air conditioning with the n'era]iy located where clean outdoor air is readily available, appara u ^ear;ng }n mind that supply and return air ducts, steam con- the desig anj drain connections, and electrical connections must be S'to the equipment proper. temperature of air leaving outlets r comfort conditioning applications, air has been distributed from riy designed outlets without producing drafts at temperatures Pf<rvin/ from approximately five to thirty degrees below the required -Voom temperature. Factors influencing the design and selection of air r tjets are: ceiling height, type of ceiling, length of blow, and temperature nd quantity of air to be distributed. Most summer conditioning instal lations are designed to supply the air to the conditioned space at from 8 to 15 deg below room temperature. Recently the use of specially designed nozzles has indicated the possibility of reducing the air quantity necessary to dissipate a given heat load by introducing the air into the room as much as thirty degrees below room temperature. Comfort con ditioning systems employing differentials greater than fifteen degrees require special consideration arid design experience because high pressure outlets or nozzles are usually used. Further, care must be taken to allow a sufficient air quantity under all load conditions to insure good distri bution. If winter heating, as well as summer conditioning, is to be accom plished by the same distributing system, the design of the outlets will be influenced as discussed in Chapter 22. Industrial systems in which.drafts are not objectionable usually employ a temperature differential equal to the dew-point depression. AIR quantity required For calculating the quantity of air required to absorb a given heat gain, the following approximate formulae may be used : M = 60 X 0.24 X (< - ty) ~dQ - : (1) or, assuming a constant value of 0.075 lb for d. O = 77a X 55.2 V 60 X -- ty) (2) where Q = volume of air required, cubic feet per minute. 77* = total sensible heat gain, Btu per hour. t = room temperature, degrees Fahrenheit. ty = outlet temperature, degrees Fahrenheit. 77 = weight of air required, pounds per minute. d cuFt a'r tenlPcrature and relative humidity of the room, pounds per L The total sensible heat gain in a restaurant when held'at 80 F is 199,736 airanrftkUr Assuming a 12 deg Fahr temperature differential between the entering of r0m temperatures, which is the same as assuming the dry-bulb temperature termg air to be 68 F, calculate the required air capacity of the system. 159