Table 1. Principal Types of Electric House Heating Systems
A. Radiators, Convectors, Unit Heaters--Built-In and Portable .
1. Metallic resistor, high- or low-temperature 2. Glass unit with metal frame (also designated as radiant convector panel unit) 3. Baseboard-type resistor 4. Resistor with fan, including unit heater 5. Resistor with focusing radiation reflector 6. Steam radiator with immersion electric element 7. Resistor unit placed in room-type air-conditioner 8. Floor furnaces
B. Panel-Type Installations
1. Ceiling panel a. Rigid composite panels containing electrically conductive rubber b. Flexible composite sheets containing embedded metallic filaments or con ductive rubber c. Electric conductors embedded in plaster on lath d. Electric conductors embedded in plaster or similar material between two layers of plaster board
2. Wall panel a. Rigid panels, as for ceilings b. Flexible sheets, as for ceilings
3. Floor panel a. Electric conductors embedded in concrete slab
C. Central Hot-Water Systems
1. Water from electric heater pumped to radiators or convectors in rooms 2. Same, with thermal storage for off-peak operation 3. Fuel-fired boiler converted to electricity 4. Heat pump systems--See Chapter 36
D. Central Warm-Air Systems
1. Resistance-element bank in housing or air duct 2. Fuel-fired furnace converted to electricity 3. Heat pump systems--See Chapter 36
vertical dimension, pattern of face grille, and arrangement of resistOTs and deflector, the convection heat delivery constitutes between 40 and 70
percent of total output.
Ratings usually are from 1000 to 8000 watts (3400 to 27,300 Btu per hr) with some models down to 500 and up to 15,000 watts. Voltages are the standardized values of 120, 208 and 240. Similar models equipped also with air circulation fans of axial type, are available; these give con vection heat delivery up to 90 percent. Other types, using the same components but without a fan, are arranged as floor furnaces to be installed
Electric Heating
1051
between floor joists. A manual switch and thermostat integral with the unit are optional.
The location of built-in electric heating units of convector type, generally along the exterior walls beneath or alongside windows, is governed by the same principles that determine arrangement of steam and hot-water con vectors, with respect to movement of warm and return air. Positions on interior walls are sometimes permissible, so long as interference from opened doors and from furniture placement is avoided. A thermostat of highsensitivity type and a conveniently located manual switch are recom mended for each unit or at least each room.
Portable units of the foregoing types, except floor furnaces, are ob tainable with plug-in extension cords for convenience and occasional serv ice. Ratings are up to 1650 watts at 120 volts; special models rated up to 5000 watts are also made, but can be used only on branch circuits having special wiring and receptacles, for 208 or 240 volts.
Radiant Convector Unit
Glass electric heating units, sometimes designated as radiant panels, depend on the heating effect produced by passage of current through a thin coating of conductive material fused to one face of a panel of |-in. thick special glass. The conductive layer may be sprayed-on aluminum or printed metallic oxide patterned to form a grid several thousandths of an inch thick, or fused-on material to give a uniform coating less than 0.0001 in. thick over the entire active face, of panel. Normal glass operating temperatures are 300 to 400 F, with maximum permissible temperature around 650 F.
Electric wiring connections are made to the panel coating at its oppo site extremities by wires soldered to the coating, by metal strips held in place with springs, or by other methods that assure low electrical resist ance. The panel is supported on insulators within a metal frame which also carries a reflector behind the glass and is arranged to provide space for air circulation. A protective guard prevents accidental contact with the hot glass.
Glass units have standardized ratings, usually between 600 and 3000 watts, for the common voltages of 120, 208 or 240 volts. Starting current for some types exceeds running current by 10 and by 50 percent. Frame sizes vary from about 30 x 24 in. for 1000-watt size to 42 x 6 in. for 300-watt baseboard model; frame types are for either recessed or surface mounting. Thermostats integral with the frame assembly are optional. Portable units equipped with plug-in extension cords are of similar construction.
Baseboard Type Unit
Metal casing proportioned to resemble and replace the conventional
'v.u baseboard along plastered or masonry walls, contains 2 or 3 resistors Placed horizontally, one above another. These usually are of low-tem perature type, with ratings 80 to 250 watts (270 to 850 Btu per hr) per near foot of baseboard unit, at 240 volts. The maximum surface tem perature of the housing is 190 F. The vertical dimension is usually 4 to 9 i^' p(ve flor btie, and the projection from face of plaster about 1.5 to 3
. Placement within the room and method of control follow the same pnnciples that apply to hot-water type baseboard installations described
Chapter 22, Radiators, Convectors, Baseboard and Finned-Tube Units.