American Society of Heating and Ventilating Engineers Guide, 1929 Class "E" equipment capable of attaining from 75 to 80 per cent on the Synthetic Air Chart. () Mechanical air supply with gravity exhaust but without air cleaning device, humidifying apparatus, temperature or humidity control. () Direct-indirect systems with either mechanical or gravity exhausts. (c) Open window and other so-called natural systems of ventilation. Table 1. Recommended Percentages of Ventilation Perfection Based on the Synthetic Air Chart* Schools: Class Rooms........._................. Manual Training Rooms.-.... Domestic Science Rooms----Amphitheatres.----- k............. Corridors.................................. Per Cent 92 90 90 90 85 Churches......................................... 85 Hospitals: Wards.-................. Operating Rooms. Other Rooms.:----- 90 95 90 Theatres: Auditorium.................................................................................................. Dressing Rooms, etc--................................................................ -............. Dance, Lodge and Assembly Halls.--................... ........................................... 85 85 85 Office Buildings: Offices in office buildings or other buildings where persons are con tinuously employed-.......................................................................... Department Stores'........................ ........................................ -.......-.................... Other Stores....................................... -..................................... :.......................... 90 88 88 Factory Buildings: The percentage desirable lor factory buildings will vary over a considerable range, depending upon the character of the work and the processes employed, modified to a considerable degree by the dust content of the air and the possibility of maintaining it free from objectionable dust and fumes. This will require careful study for each instal lation. The following Table 2 is offered as a guide for proportioning ventilation on the basis of square feet of floor spaceand may be used for certain cases where it might be more applicable than the cubic feet per person basis on account of the number of occupants being unknown or subject to possible change, or more applicable than the air change basis where unusual ceiling heights 6ccur. Table 2. Air Required for Ventilation Based on Square Feet of Floor Space Schools: Classrooms..................................... 2.0 cu. ft. Assembly rooms............................ 1.5 cu. ft. Gymnasia........ ............................... 1.5 cu. ft. per minute per square foot of floorarea per minute per square foot of floorarea per minute per square foot of floorarea See Chapter XXXIV for description and data on the use of the Synthetic Air Chart. 388 Chapter XXIV--Systems of Ventilation Picture Machine Booth--............ 1.5cu. ft. per minute per square foot of floor area Dining-rooms....... ................... 1.5cu. ft. per minute per square foot of floor area Kitchens.--.................................... 2.0cu. ft. per minute per square foot of floor area Corridors......................................... 0.5cu. ft. per minute per square foot of floor area Wardrobes and lockers................. 2.0cu. ft. per minute per square foot of floor area Toilet, Bath, Etc--...................... 2.0cu. ft. per minute per square foot of floor area Theatres: Seating spaces-....................... 2.0cu. ft. per minute per square foot of floor area Toilets, etc........ ........................... 2.0cu. ft. per minute per square foot of floor area Hotels: Assembly rooms.... ........................ 2.0cu. ft. per minute per square foot of floor area Dining-rooms....... .......................... 1.5cu. ft. per minute per square foot of floor area Kitchens....................;.................... 4.0 cu. ft. per minute per square foot of floor area Hospitals: Wards............................................... 1.0cu. ft. per minute per square foot of floor area Dining-rooms....... .......................... 1.5cu. ft. per minute per square foot of floor area Toilets.......................................... 2.0cu. ft. per minute per square foot of floor area Kitchens.--.................................... 4.0cu. ft. per minute per square foot of floor area Note.--See Chapter XXIII (Modern Standard of Ventilation. Etc.) and Chapter XXV (Air Condi tioning and Cooling) for further data on the quantities of Air required for Ventilation. UNIT SYSTEMS2 Unit systems consist of an individual unit incorporating all the apparatus necessary for providing, directing and controlling the necessary volume of air heated to the proper temperature for the purpose. Two types are in common use, one for public building work and the other for factory and industrial installations. All unit heating and ventilating devices consist essentially of small fans connected closely with heat radiating surfaces. Steam or hot water usually is used for heating, and electric motors usually are used for power. Public Building Work A unit heating and ventilating machine intended for public building work consists usually of a small rectangular steel cabinet, enclosing the following essential parts:-- 1. A fresh air inlet. 2. An air filter. 3. A motor and fan assembly. 4. A radiator or heating element. 5. A cold air or by-pass chamber. 6. Mixing chamber. 7. Air discharge outlet. 8. Fresh air and recirculating control damper. 9. A by-pass or temperature control damper. Note.--Both the recirculating control damper and the by-pass damper can be manually operated, or the recirculating control damper may be pneumatically controlled from some remote point. The by-pass or temperature control damper can be automatically operated on room temperature by means of ther mostatic motor in connection with the use of any pneumatic automatic temperature control system. (See also Chapter XVI.) When the fresh air inlet damper is open the fresh air is drawn im mediately from out of doors, having the dust and dirt removed by means of the air filters. From this point the air is driven by means of the motor a; PhiladdphS! panWbUted by H- B- New York, N. Y.; G. E. Otis, Moline. III., and 389