Document JJ5o71K7Q6nJaEGxO5EgZRJqZ
hVOffjuli Lp
C '^ c
Viqm fNM[ io:*iioni E. Scott Tucker - RRD Laboratories - 1700 So. Sorrnnd
February 26, 1969 AROCLOR WATER SOLUBILITY
R. E. Keller - So. Second W. R. Richard - GO E`. P. Wheeler - GO
TO :L. R. Stark General Offices
2 DEPOSITION
i EXHIBIT ^ | Richer# .
| 20-lf>
An^ analytical procedure for extracting, concentrating, and measuri rig" "Aroclor at the sub ppm level in water has been developed and verified with Aroclor "spiked" tap water samples (Table I).
This procedure was employed to determine the tap water solu- '
bility of Aroclor 1242, 1248 and 1254 (Table II).
.
The Aroclor saturated tap water samples used in this study were prepared in. the following manner: two 60-70 g. portions of each Aroclor fluid were placed in 32os. narrow neck screw top glass bottles and 500 ml. of tap water (South Second Street) added to each. The bottles were then placed on a roller mill, rolled for 24 hours and allowed to stand undisturbed at room temperature (25C) until analyzed. The period of time between preparation and analysis was approximately 4-5 months.
Inspection of EC/GC traces and the data in Table II indicates
that the solubility of Aroclor is a function of both the amount
of chlorination and the position. This anticipated behavior
makes absolute quantification difficult since a standard with
the same isomer distribution of the water solubilized material .
is impossible to_prepare. Therefore, the "Aroclor found" was
calculated in this manner: the original Aroclor in question
was used as a standard and a calibration curve prepared by
"
plotting the peak height of the major isomers versus pg Aroclor.
The peak height response of the samples were then totaled,
corrected for a tap water blank response and the amount of . .
"Aroclor found" determined from the calibration curve. A
.
rough idea of the error inherent in this procedure can be
obtained by using 1242 as a standard for 1248, etc. A devia
tion on the order of +10% was experienced.
.
The data in Table II also seems to indicate that a stable
Aroclor-water emulsion is formed at approximately twice their
solubility levels.
`
' *
The Pydraul fluids being multi-component systems are a completely different story and as such will require much more effort. At this point, I think we should probably clarify what information is actually desired and if the need for this information can be justified in terms of the effort necessary to obtain it.
db Attachments - 2
E. Scott Tucker
000081$ '
HARTOLDMON0013193
TABLE I
RECOVERY OF AROCLOR FROM SPIKED TAP WATER SAMPLES**
,................. ............ USING EC/GC............................................
,
Sample Number
ppb Aroclor Added
OR 88932 . #1
1980
OR 88932 *2
1980
Sample
ppb Aroclor
Volume (ml) ` ` ` Found
250
1960
250 ` _____ *
Per Cent Recovery Comments
.
99.0
Aroclor 1242. Samples con centrated wit) vac. rot. eva; Results ob.tained 9-6-68
OR 88945 n
OR 88945 2
OR 88945 #3
OR 88945 f4
270
270
.
540
540
225 225 225 225
266 266 577 577
98.5 . 98.5 107.0 107.0 .
Aroclor 1254. Samples con centrated c" Kundera-Danis evaporative concentrators Results ob tained 12-13-
-
The sample preparation and work up outlined for water samples was employed. The results were quantified by preparing a calibration curve using a hexane solution of the Aroclor 1242 and 1254 used to spike the water samples. The major isomer peak area was used to construct the curve. The water samples were spiked by injecting >il amounts of a concentrated acetone***-Aroclor solution.
_
* Sample contaminated - results discarded.
** Data used to confirm proposed water sample
work up procedure and concentration
techniques.
.
*** Spiked water samples contained 40-60 ppm
Acetone.
'
0000314
HARTOLDMON0013194
TABLE II SOLUBILITY OF AROCLOR IN TAP WATER
Sample Ident. Number
1242 OR 88936-1+
-2+ -1* -2*
Grams Aroclor Sample Equilibrated Vol.(ml)
67.5 67.5 55.1 55.1
* 225
225 250
250
ppb Aroclor Found
193 213 372 378
Average
203 + 10 375 + 3
1248 OR 88936-1+
-2+ -1* -2*
. 1254 OR 88936-1+
-2+ -1* -2*
70.5 70.5 70.6 70.6
73.2 71.2 69.7 69.7
250 250 . 224 225
*
250
250 224 225
92 120 196 222
51 48 134 143
106 + 14 209 + 13
.50 + 2 139 + 5
Aqueous sample filtered through pre-wetted Whatman #2 filter paper..
Aqueous sample carefully siphoned from bottle.
'
/
0800315
HARTOLDMON0013195